Marley Ceiling Fan Accessories User manual

Type
User manual
OPERATING INSTRUCTIONS
MODELS: 12001N and 12005N
READ CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR SERVICE NOISELESS
SPEED CONTROLS!
RETAIN INSTRUCTIONS FOR FURTHER REFERENCE.
NOISELESS SPEED
CONTROLS
CAUTION: To Be Used Only With Leading Edge 48” and 56”, 120 Volt Ceiling Fans. Will Cause
Damage To Other Fans.
General Safety Information
WARNING: DISCONNECT POWER SUPPLY
BEFORE WIRING CONNECTIONS ARE MADE TO
PREVENT POSSIBLE ELECTRICAL SHOCK OR
DAMAGE TO EQUIPMENT.
WARNING: READ AND FOLLOW INSTRUCTIONS
CAREFULLY. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN FIRE, ELEC-
TRICAL SHOCK, INJURY TO PERSONS, AND/OR
DAMAGE TO EQUIPMENT.
1. All wiring should conform to the National Electrical
Code and local regulations.
2. Do not mount in an area which will allow the control
to come in contact with moisture.
3. Make certain the entire installation is grounded as a
precaution against possible electrical shock.
4. Do not exceed maximum amperage rating of the
control as overloading can result in damage to
ceiling fan and control.
5. The control is designed to control FAN ONLY.
6. DO NOT CONNECT LEADS ACROSS LINE.
Be sure that 1 wire in switch box goes to the motor
and the other goes to the line power. See diagram
#4.
Specifications
MODEL
VOLTS
50/60 Hz
MAX
AMPS
FOR USE ONLY WITH
CEILING FAN MODEL NUMBERS
12001N 120 1.0
4820-1/5600-1
5600-1LC/5630-1RDP/5610-1
MODEL
VOLTS
50/60 Hz
MAX
AMPS
FOR USE ONLY WITH
CEILING FAN MODEL NUMBERS
12005N 120 5.0
4820-1/5600-1
5600-1LC/5630-1RDP/5610-1
MODEL 12001N Use only ONE fan per Control. DO
NOT connect more than one fan to one Control. Control
is rated 1 AMP.
MODEL 12005N Use only TWO fans per Control. Even
though control is rated at 5 AMPS, DO NOT connect
more than TWO Fans to ONE Control.
3
2
1
_
Installation
1. Turn electrical power OFF at Circuit Breaker before
making any connections.
2. Remove wall plate. Disconnect and remove switch or
control to be replaced. See Diagrams #1 and #2.
3. Make wiring connections as shown in Diagrams #4 and
#5. Connect the black from the 120V supply to one
black on the control. Connect the second black of the
control to the black from the fan motor. Make sure that
the wire strands are straight and attach the wire leads
of the control to the circuit wires by twisting them
together. Twist a wire nut onto each connection.
4. Check all connections for tightness; leave no exposed
copper conductor.
5. Position connections in box, leaving room for control.
See Diagram 3.
MODEL 12001N For use with one fan only.
MODEL 12005N For use with two fans only.
Connecting more than recommended number of
fans could cause damage to Fans and/or Control.
6. Install speed control in wall box using screws
supplied. See Diagram 3.
7. Replace wall plate. Set switch on “OFF” position.
Turn power on at Circuit Breaker.
Operation
Your control provides 3 precise preselected
speeds, because it is a reactor type (impedance)
control, it will feel very warm to the touch in
operation. This is perfectly normal, and has been
tested to be well within all safety limits.
Diagram 1
Diagram 2
Diagram 3
Diagram 4
Diagram 5
BLACK
BLACK
BLACK FAN WIRE
BLACK
BLACK
GROUND
WHITE
FAN
120V
60Hz
SUPPLY
SPEED CONTROL
12001N Single Fan Wiring Diagram
SPEED CONTROL
12005N Two
Fan Wiring
Diagram
BLACK
BLACK
BLACKBLACK
BLACK
WHITE
GROUND
WHITE
GROUND
HOW TO ORDER REPAIR PARTS
In order to obtain any needed repair or replace-
ment parts, warranty service or technical information,
please contact Marley Engineered Products Service
Center toll-free by calling 1-800-642-HEAT.
Part No. 5200-2406-000 07-99
PPD021
2
LIMITED WARRANTY
All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for three years from date of installation. This warranty does not apply to
damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in vio-
lation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation.
The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to Marley Engineered
Products Service Center. Within the limitations of this warranty, inoperative units should be returned to the nearest Marley authorized service center or the Marley Engineered Prodcuts Service
Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley
Electric Heating.
THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FORA PAR-
TICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED
PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILI-
TY, OR CONTRACT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights which vary from state to state.
For the address of your nearest authorized service center, contact Marley Engineered Prodcuts in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the factory must be accompa-
nied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization, include all catalog numbers shown on the
products.