En
NAME OF PARTS
Fig. 1
Fig. 1 Outdoor Unit
1 Intake Port
2 Outlet Port
This breaker is installed during the
electrical installation.
Electrical Breaker
Fig. 2
SPECIFICATIONS
NOTES: Specifi cations are based on the following conditions.
Cooling: Indoor temperature of 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB, and outdoor temperature of 95 °F (35.0 °C) DB / 75 °F
(23.9 °C) WB .
Heating: Indoor temperature of 70 °F (21.1 °C) DB / 60 °F (15.6 °C) WB, and outdoor temperature of 47 °F (8.3 °C) DB / 43 °F
(6.1 °C) WB.
Pipe length: 25 ft (7.5 m)
Height difference between outdoor unit and indoor unit: 0 ft (0 m)
● Acoustic Noise Information: The maximum sound pressure level is less than 70 dB (A) for both indoor and outdoor unit.
According to IEC 704-1 and ISO 3744.
● If the air conditioner is operated under higher temperature conditions than those listed, the built-in protection circuit may operate to
prevent internal circuit damage.
Also, during cooling and dry modes, if the unit is used under conditions of lower temperatures than those listed above, the heat-
exchanger may freeze, leading to water leakage and other damage.
●
Do not use this unit for any purposes other than the Cooling, Heating, Dehumidifying, and air-circulation of rooms in ordinary dwellings.
*1: Electrical data is only for outdoor unit.
*2: The protective function might work when using it outside the temperature range.
Model name
Outdoor unit AOU36RLAVS AOU48RLAVS
Power source 208/230 V, ~, 60 Hz
Available voltage range 187 to 253 V
Nominal
capacity
Cooling
Btu/h (kW)
36,000 (10.6) 48,000 (14.1)
Heating 42,000 (12.3) 54,000 (15.8)
Nominal
Input power
*1
Cooling
kW
2.96 4.89
Heating 3.20 4.36
Refrigerant (R410A) lbs (kg) 8.82 (4.0)
Dimensions & Weight
Height in (mm) 39-5/16 (998)
Width in (mm) 38-3/16 (970)
Depth in (mm) 14-9/16 (370)
Weight lbs (kg) 194 (88)
Operation temperature range *2
Cooling
°FDB
(°CDB)
23 to 115 (-5 to 46)
Heating -4 to 70 (-20 to 21)