Troubleshooting
Sensor-switched floodlight
without power
Sensor-switched halogen floodlight
will not switch ON
Sensor-switched halogen floodlight
will not switch OFF
Sensor-switched halogen floodlight
comes ON when it should not
Malfunction
■ fuse faulty, not switched ON
■ short circuit
■ fit new fuse, switch ON mains
switch, check wiring with voltage
tester
■ check connections
■ twilight setting in night-time
mode during daytime operation
■ bulb faulty
■ power switch OFF
■ fuse faulty
■ detection zone not properly
targeted
■ adjust setting
■ change bulb
■ switch ON
■ fit new fuse, check connection
if necessary
■ re-adjust
■ continued movement within
the detection zone
■ check zone, adjusting
if necessary, or shroud
■ wind is moving trees and bushes
in the detection zone
■ cars in the street are being
detected
■ sudden temperature changes
due to weather (wind, rain, snow)
or air expelled from fans, open
windows
■ fit shrouds to mask out zones
■ fit shrouds to mask out zones
■ change detection zone,
change site of installation
Cause Remedy
Sensor-switched halogen floodlight
keeps switching ON and OFF
■ continued movement within
the detection zone
■ check zone, adjusting
if necessary, or shroud
Technical specifications
Dimensions:
(h x w x d) 250 x 155 x 102 mm
Output: 150 watts max. / R7S
Additional switching capacity L’: 500 watts max.
Connection: 230 – 240 V AC
Angle of coverage: 160° with sneak-by guard, 40° angle of aperture
Sensor tilting range: 70° vertically
Reach: 12 m max.
Time setting: 10 sec. – 15 min. (factory setting: 10 sec.)
Twilight setting: 2 – 2000 lux (factory setting: 2000 lux)
Enclosure: IP 44
Weight: approx. 1000 g
Projected floodlight area: approx. 263 cm
2
(for calculating wind load)
Installation / Wall mounting
Installation height:
To obtain the specified reach of 12 m, the sensor
should be installed at a height of approx. 2 m.
The mains supply lead is a 3-core cable.
L = live conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors using
a voltage tester; then switch off the power again.
Important: Connecting the conductors to the wrong
terminals will produce a short circuit in the unit or
your fuse box at a later stage when you come to
switch the power on. In this case, you must identify
the individual cables and re-connect them. A mains
switch for switching the unit ON and OFF may of
course be installed in the power supply lead.
Connecting an additional load
It is possible to connect an additional load to the
sensor-switched halogen floodlight.
When doing so, please observe the maximum
permissible power output (see Technical Specifi-
cations).
The live conductor must be connected to the terminal
marked L’. The neutral conductor of the additional
load must be connected to the terminal marked N
together with the neutral conductor of the mains
power lead. Connect the protective-earth conductor
to the earth terminal.
Important: Reversing the connections may result in
damage to the unit. You could also get an electric
shock.
Functions ,
Twilight setting (sensor response threshold)
(factory setting: daylight operation 2000 lux)
The sensor's response threshold can be infinitely
varied from 2 – 2000 lux.
Control dial set to = daylight operation
approx. 2000 lux.
Control dial set to = night-time operation
approx. 2 lux.
To adjust the detection zone in daylight, the control
dial must be set to (daylight operation).
Switch-off delay (time setting)
(factory setting: 10 sec.)
Light ON time can be adjusted continuously from
10 sec. to 15 min.
Control dial set fully clockwise =
shortest time (10 sec.).
Control dial set fully anti-clockwise =
longest time (15 min.).
When setting the detection zone, we recommend
selecting the shortest time.
- 12 -
Reach adjustment
Reach can be adjusted by tilting the sensor
(through 70°).
Precision adjustment with shrouds
Shrouds may be used to define the detection zone
exactly as you require in order, for example, to mask
out neightbouring premises or specifically target paths.
The shrouds can be divided or cut with a pair of scis-
sors along the vertical and horizontal grooves.
Operation / Maintenance
The sensor-switched halogen floodlight is suitable for
activating light automatically. The unit is not suitable
for burglar alarm systems as it does not provide the
level of sabotage protection that is prescribed for this
purpose. Weather conditions may affect the way the
sensor-switched halogen floodlight functions. Strong
gusts of wind, snow, rail, hail may cause the light to
come ON when it is not wanted because the sensor
is unable to distinguish sudden changes in tempera-
ture from sources of heat. The detector lens may be
cleaned with a damp cloth if it gets dirty (do not use
cleaning agents).