5.4.2. J7 Terminal board - Power supply (fig. 23)
POWER SUPPLY (terminals PE-N-L):
PE: Earth connection
N:Power supply ( Neutral )
L:Power supply ( Line )
NB.: For correct operation, the board must be connected to the
earth conductor in the system. Install an adequate differential
thermal breaker upstream of the system.
To install several partial opening pulse generators, connect
the N.O. contacts in parallel (fig.35).
FSW OP - Opening safety devices contact (terminal 3): The purpose
of the opening safety devices is to protect the leaf movement
area during opening. During opening, in the A-AP-S-E-EP
logics the safety devices reverse the movement of the gate,
or stop and restart the movement when it is released (see
advanced programming in Chpt. 5.5.2). During the opening
cycle in logics B, C and B/C, they interrupt movement.
They
never operate during the closing cycle.
If the Opening safety devices are engaged when the gate
is closed, they prevent the opening movement.
To install several safety devices, connect the N.C. contacts in
series (fig.25).
NB.: If no opening safety devices are connected, jumper
connect inputs FSW OP and -TX FSW (fig. 26).
FSW CL - Closing safety devices contact (terminal 4): The purpose
of the closing safety devices is to protect the gate movement
area during closing. During closing, in the A-AP-S-E-EP
logics, the safety devices reverse the movement of the
gate, or stop and reverse the movement when it is released
(see advanced programming in Chpt. 5.5.2). During the
closing cycle in logics B, C and B/C, they interrupt movement.
They never operate during the opening cycle. If the Closing
safety devices are engaged when the gate is open, they
prevent the closing movement.
To install several safety devices, connect the N.C. contacts
in series (fig.25).
NB.: If no closing safety devices are connected, jumper
connect terminals FSW CL and -TX FSW
(fig. 26).
STOP - STOP contact (terminal 5): any device (e.g. a push-button)
which, by opening a contact, stops gate movement.
To install several STOP devices, connect the N.C. contacts
in series (fig. 25).
NB.: If STOP devices are not connected, jumper connect
the STOP and - terminals.
SAFE - EDGE safety device contact (terminal 6): The purpose of the
"edge" safety device is to protect the leaf movement area
during opening/closing. In all logics, during opening and
closing, the safety device reverses gate movement for 2
seconds. If the safety devices operate again during the 2-
seconds reversing time, it stops movement (STOP) without any
reversing.
If the Edge safety device is engaged while the gate is closed
or open, it prevents movement.
To install several safety devices, connect the N.C. contacts in
series (fig.25).
NB.: If edge safety devices are not connected, jumper
connect the SAFE and - inputs (fig. 26).
–
Negative for power supply to accessories (terminals 7
and 8)
+ 24 Vdc - Positive for power supply to accessories (terminals
9 and 10)
Important: Accessories max. load is 500 mA. To calculate absorption
values, refer to the instructions for individual accessories.
Connection of a pair of closing photocells and a pair of
opening/closing photocells
Connection of two N.O. contacts in parallel
(e.g. Open A, Open B)
5.4.3. J6 Terminal board - Motors and flashing lamp
(fig. 23)
MOTOR - (terminals MOT-C, MOT-1, MOT-2): Motor connection
(see Par. 6.5).
LAMP - (terminals LAMP L, LAMP N): Flashing lamp output 230Vac
max 60W.
5.4.4. J1 Terminal board - Accessories (fig. 23)
Consult the relevant tables for a detailed description of
operation in the different logics
OPEN A - “Total Opening” command (terminal 1): any pulse
generator (push-button, detector, etc.) which, by closing a
contact, commands total opening and/or closing of the
gate leaf.
To install several total opening pulse generators, connect
the N.O. contacts in parallel (fig. 35).
OPEN B - “Partial opening” or “Closing” command (terminal 2): any
pulse generator (push-button, detector, etc.) which, by
closing a contact, commands partial opening and/or
closing of the gate leaf.
In the B, C and B/C logics, it always
commands gate closure.