Active Ventilation Products RC-9-H12 User manual

  • Hello, I've analyzed the provided document regarding the Active Ventilation Products Roof Curb model RC-9-H12. It appears to be an installation guide, detailing the steps to fit the curb. The guide specifies the dimensions, the type of screws to be used, and the material used which is Aluminum Alloy 3003-H14. It also includes instructions on cutting the opening on the roof and flashing the curb onto the deck. Feel free to ask me any questions you might have about this product and installation process.
  • What size hole needs to be cut in the roof deck?
    How many screws are needed for the flange?
    What type of screws are recommended for installation?
2.5"
2.5"
1"
5"
5"
1"
1.25"
11"11"
12"
1. Cut a round hole 11" in diameter in the roof deck.
2. Total number of screws needed for flange = 12
3.
Recommended installation screw: #10 x 1 1/2" Sheet Metal Screw
4. Flash roof curb onto deck according to specifications of the
membrane manufacturer.
5. Screws not included.
Wood nailer
Insulation
Membrane
Screw
Roof deck
Exhaust or Intake
Curb Mount Flange
Roof Vent
Duct from
Below
Roof Curb
Active Ventilation Products, Inc.
Website: roofvents.com Email: [email protected]
Roof Curb Model: RC-9-H12
Inside Opening: 11", Outside Length & Width: 12", Height: 12"
1/1/2023
Roof Curb Installation Instructions
Roof Curb Flashing Detail
Angled View
Top View
Screws
- Aluminum Alloy 3003-H14
- Thickness = 0.025" ± 0.005
- Tolerance = ± .25 ( 14" )
/