Ubiquiti U6-MESH User guide

Category
Network switches
Type
User guide

Ubiquiti U6-MESH is a powerful Wi-Fi 6 access point designed to provide fast and reliable wireless connectivity for indoor and outdoor environments. With its advanced features like MU-MIMO and OFDMA, it can handle multiple devices simultaneously, reducing latency and improving overall network performance. Ideal for homes, offices, and public spaces, the U6-MESH offers seamless roaming and can be easily managed using the UniFi Network Controller.

Ubiquiti U6-MESH is a powerful Wi-Fi 6 access point designed to provide fast and reliable wireless connectivity for indoor and outdoor environments. With its advanced features like MU-MIMO and OFDMA, it can handle multiple devices simultaneously, reducing latency and improving overall network performance. Ideal for homes, offices, and public spaces, the U6-MESH offers seamless roaming and can be easily managed using the UniFi Network Controller.

Ethernet)
UTP Cat5/6 cable for indoor installations
•The cable outlet opening must be located on the opposite side of the open
environment. •The cable should face downward when mounting on the wall.
•Category 5 (or higher) shielded cabling with drain wire must be used for all outdoor wired
Ethernet connections and must be connected to the AC ground of the PoE.
System Requirements •Linux,
Mac OS X or Microsoft Windows 7/8/10 •Java
Runtime Environment 1.7 (1.8 or later recommended) •Web
Browser: Google Chrome (Other browsers may have limited functionality) •UniFi Controller
Software v5 .4 or later (available at: ui.com/download/unifi)
•Phillips screwdriver
•Drill and bit (6mm for wall mount or 3mm for ceiling mount) •Optional: drywall or
jigsaw (to cut 18mm hole for wire
•We recommend that you protect your networks from harmful outdoor environments and
electrostatic discharge phenomena with Ubiquiti's industrial grade shielded Ethernet cable. For
more information, visit ui.com/toughcable
U6-MESH Quick Start Guide
Outdoor Installation Requirements
installation requirements
Powering on the UniFi Access Point The
U6-MESH has auto detection compatible with the following sources:
UniFi Power with Ubiquiti PoE Switch compatible with PoE+
802.3at/PoE 802.3af Ubiquiti Gigabit PoE Adapter (48 Vdc, 0.5 A )
The U6-PRO single pack includes a Gigabit PoE adapter. For multi-pack units, PoE adapters
or a UniFi switch with PoE can be purchased separately.
1. Connect the Ethernet cable from the device to the POE port of the PoE adapter.
Connect the Ethernet cable from the UniFi Access Point directly to a PoE port on the switch.
3. Connect the power cord to the adapter, and then plug the power cord into a power outlet.
2. Connect an Ethernet cable from your LAN to the LAN port of the PoE adapter.
Connection to a PoE adapter
Connecting to a UniFi switch with PoE
Mounting the PoE adapter (optional)
1.Remove the PoE mounting bracket from the adapter, place the bracket in the desired position
and mark the two holes.
2.Drill holes, if necessary, and secure the bracket using two rivets (not included).
3.Align the slots on the adapter with the tabs on the PoE mounting bracket, then slide the
adapter down.
You can manage your wireless network and view network statistics through the UniFi Controller's
management interface. For information on setting up and using the UniFi Controller software,
see the User's Guide.
Installing the mobile app Ubiquiti also offers a
UniFi app, available from the App Store® (iOS) or the Google Play™ Store
(Android). You can use it to make use of basic UniFi access point features
without the need to set up a UniFi controller. It also allows constant connection
of access points for remote controllers (controllers not on the same Layer 2
network) and easy access to local controllers and those being monitored on
unifi.ui.com
Software Installation
Download and install the latest version of the UniFi Controller software. Run it
and follow the instructions on the screen. The software and step-by-step User
Guide instructions are available at: ui.com/download/unifi Once you have
installed the software and run the UniFi Setup Wizard, a login screen for the
UniFi Controller management interface will appear. Enter the administrator
name and password you created and click the option to login.
and. A protective connection must be installed in accordance with national wiring rules and regulations.
2. Pay attention to all warnings.
The indicated AC adapter provides a safety ground. For installation in a building, adequate short-circuit
back-up protection must be provided.
2. This equipment contains no operator-serviceable parts. Only a qualified service technician should provide services.
b.
3. Only use the devices or accessories indicated by the manufacturer.
c.
3. This equipment is supplied with a detachable power cord that has an integral safety ground wire designed to be
connected to a safety ground. to. Do not substitute the power cord with one other than the approved type provided.
Never use an adapter plug to connect to a two-wire outlet, as it will break the continuity of the ground wire.
d.
The equipment requires the use of the ground wire as part of the safety certification. Modification or
misuse can create a shock hazard, which could cause serious injury or death.
1. It is mandatory to comply with the current, frequency and voltage requirements indicated on the manufacturer's
label. Connection to a power source other than those specified may result in malfunction, equipment damage, or fire
hazard if limitations are not followed.
1. Read, follow and save these instructions.
If you have any questions about the installation, contact a qualified electrician or the manufacturer
before connecting the equipment.
safety instructions
electrical safety information
limited warranty
FCC
IMPORTANT NOTE
Radiation Exposure Statement •This equipment
complies with radiation exposure limits set forth for an uncontrolled environment. •This
equipment should be installed and used with a minimum distance of 20 cm between the
radiator and your body. •This transmitter must not be co-located or used in conjunction
with any other antenna or transmitter.
Mexico (NOM-208-SCFI-2016)
Compliance
ui.com/support/warranty
The limited warranty requires arbitration to resolve disputes on a case-by-case basis and, where
appropriate, specifying arbitration instead of jury trials or class actions.
The FCC has approved this radio transmitter.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions.
1.This device may not cause harmful interference.
2.This device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
For use in Mexico, operation of this equipment is subject to the following two conditions: 1. this
equipment or device may not cause harmful interference, and 2. this equipment or device must
accept any interference, including interference that may cause unwanted operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide acceptable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at his own
expense.
WEEE Compliance Statement
online resources
Declaration of conformity
CE marked
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Ubiquiti U6-MESH User guide

Category
Network switches
Type
User guide

Ubiquiti U6-MESH is a powerful Wi-Fi 6 access point designed to provide fast and reliable wireless connectivity for indoor and outdoor environments. With its advanced features like MU-MIMO and OFDMA, it can handle multiple devices simultaneously, reducing latency and improving overall network performance. Ideal for homes, offices, and public spaces, the U6-MESH offers seamless roaming and can be easily managed using the UniFi Network Controller.

Ask a question and I''ll find the answer in the document