Alessi Sense

Oras Alessi Sense Installation guide

  • Hello! I've reviewed the installation and maintenance guide for the Alessi Sense faucets, models 8710F and 8712F. These touchless faucets offer features like automatic shut-off, adjustable flow times, and automatic flushing. I'm ready to answer your questions about their setup, operation, or any other aspects covered in the document.
  • What type of battery does the 8710F model use?
    What is the maximum water temperature for these faucets?
    What is the default maximum short flow time?
    What is the default automatic flush duration?
    What is the maximum long flow time?
    What is the IP protection rating for these faucets?
Installation and maintenance guide
Alessi Sense
by Oras
3 (24)
4
5-13
13-15
16-21
22
4 (24)
G 1 1/4
20 - 80
ø 63
152
170
118
ø 34 - 37
max 35
365
G 3/8
3 x l = 400
G 1/2
G 1/2
204
154 120
32
G 1/2
G 1/2 G 1/2
G 1/2
185
l = 1500
G 1 1/4
20 - 80
ø 63
152
170
118
G 1/2
ø 34 - 37
max 35
365
260
G 3/8
G 1/2
l =400
mpi.oras.com/8712F
mpi.oras.com/8710F
8712F
I (ISO 3822)
EN 15091, EN 1113, EN 1111
100 - 1000 kPa
0.07 l/s (300 kPa w/Controller)
200 kPa (0.1 l/s)
max. +70°C
IP 44
Lithium 2CR5 6 V, AA 1.5 V
Lithium x 2, CR 2450 3 V
(EMC 2014/30/EU , 2011/65/EU)
8710F
I (ISO 3822)
EN 15091
100 - 1000 kPa
0.07 l/s (300 kPa w/Controller)
200 kPa (0.1 l/s)
max. +70°C
IP 44
Lithium 2CR5 6 V
(EMC 2014/30/EU , 2011/65/EU)
5 (24)
max 35
ø 34-37
R >30mm
Oval < 15%
3
44
2
1
1
36
3
OFF
4
4
6 (24)
2
1
2
°C-
°C +
3
2
1
3
51
2
4
19
12
7 (24)
2
1
4
2
3
°C-
°C +
3
2
1
3
51
2
4
. . .
19
14
8 (24)
1
3
1
1
1
3
2
1
3
51
2
4
8712F
9 (24)
4
4 6
1
17
8
...
6
7
8
9
°C-
°C +
1
2
5
4
3
2 4
24
9
6...
...
8712F
10 (24)
5
6
1
4
2
3
AA 1.5V +
AA 1.5V +
AA 1.5V x 2
Lithium
3
2
1
3
51
2
4
30
11 (24)
7
8
1
2
3
3
2
1
3
51
2
4
23
~1 s
23
CR 2450 3 V Lithium
1
12 (24)
12
3
4
38°C
5
38°C38°C
13 (24)
1 3
4
2
1
2
3
14 (24)
6 s
automatic off
on/off
3
2
1
~1 s
~1 s
ON ~1 min
OFF
max. 2 min
automatic o
ON / OFF
6 s
automatic o
8712F
15 (24)
G1
Example 1: Max short flow 6 s 30 s
Example 2: Operation mode FS =factory settings
G1
G2
G3
G4
G5
R1
R2
R3
R4
R5
R6
R7
R1
R2
R3
R4
< 5 s
> 5 s
< 5 s
> 5 s
25
6
134
25
6
134
Factory default 1 x 2 x 3 x 4 x 5 x 6 x 7 x 8 x
Max short ow (sec) 1 x 4 6 8 10 15 20 30 60
Max long ow (sec) 2 x 30 45 60 90 120 240 300 600
Automatic ush (h) 3 x 0 12 24 48 72 - - -
Automatic ush (sec) 4 x 10 30 60 120 180 240 300 600
Operation mode 5 x OFF1) ON2) - FS3) ----
1) Short lights OFF
2) Short lights ON
3) Factory settings
16 (24)
OFF
19
2 3
1
°C-
°C +
OFF
1
3
3
2
2
OFF
17 (24)
~1 s
~1 s
~1 s
1
2
1
Lithium
2CR5 6V
1
=
=
ALKALINE
~1 s
18 (24)
4
1
2
=
ALKALINE
+
-
Lithium
CR2450 3 V
2
13
ALKALINE
1
2
+
-
CR2450
3V
4
3
19 (24)
1
2
=
AA 1.5V +
AA 1.5V +
2
ALKALINE
1
2
Lithium
AA 1.5 V x 2
8712F
20 (24)
1
4
2
5
6
1 2 4 7
3
7
6
24
5
600372
/