Ronix RC-8010 User manual

Category
Power tools
Type
User manual
AIR COMPRESSOR 80LITER
RC-8010
USER MANUAL 3
PRODUCT SPECIFICATIONS
Model RC-8010
Power 2.5HP
Voltage 220-240V
Frequency 50-60Hz
Speed 2800RPM
Weight 42kg
Max Pressure 8bar/116psi
Air Delivery 230L/min
Tank Capacity 80L
Supplied In Ronix Color box
Includes Air Filter, Oil Bottle, Two Wheels, 2 air
couplers
PARTS LIST
Pressure gauge
Safety switch
Coupler
Pressure regulator
Motor housing
AIR COMPRESSOR
4
GENERAL POWER TOOL SAFETY WARNINGS
WARNING!
- Read all safety warnings and all instructions. Failure to follow the warnings
and instructions may result in electric shock, fire and or serious injury.
- Save all warnings and instructions for future reference.
- The term “power tool” in the warnings refers to your mains-operated
(corded) power tools or battery operated (Cordless) Power tools.
.WORK AREA SAFETY
- Keep work area clean and well lit. Cluttered or dark areas invite accidents.
- Don’t operate power tools in explosive atmospheres, such as in the
presence of flammable liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
- Keep children and bystanders away while operating a power tool.
Distractions can cause you to lose control.
.ELECTRIC SAFETY
- Power tool plugs must match the outlet. Never modify the plug in any
way. Don’t use any adaptor plugs with earthed (grounded) power tools.
Unmodified plugs and matching outlets will reduce risk of electric shock.
- Avoid body contact with earthed or grounded surfaces such as pipe,
radiators, ranges and refrigerators. There is an increased risk of electric
shock if your body is earthed or grounded.
- Don’t expose power tools to rain or wet conditions. Water entering a
power tool will increase the risk of electric shock.
- Don’t abuse the cord. Never use the cord for carrying, pulling or
unplugging the power tool. Keep cord away from heat, oil, sharp edges
or moving parts. Damaged or entangled cords increased the risk of
electric shock.
- When operating a power tool outdoors, use an extension cord suitable
for outdoor use. Using a cord suitable for outdoor use will reduce the risk
of electric shock.
USER MANUAL 5
- If operating a power tool in a damp location is unavoidable, use a
residual current device (RCD) protected supply. Use of an RCD reduces
the risk of electric shock.
- Use of power supply via a RCD with a rated residual current of 30mA
or less is always recommended.
.PERSONAL SAFETY
- Stay alert, watch what you are doing and use common sense when
operating a power tool. Don’t use a power tool while you are tired
or under the influence of drugs, alcohol or medication. A moment
of inattention while operating power tools may result in serious
personal injury.
- Use personal protective equipment. Always wear eye protection.
Protective equipment such as dust mask, non-skid safety shoes, hard
hat, or hearing protection used for appropriate conditions will reduce
personal injuries.
- Prevent unintentional starting. Ensure the switch is in the off-position
before connecting to power source and/or battery pack, picking up or
carrying the tool. Carrying power tools with your finger on the switch or
energizing power tools that have the switch on invites accidents.
- Remove any adjusting key or wrench before turning the power tool on.
A wrench or a key left attached to a rotating part of the power tool may
result in personal injury.
- Don’t overreach. Keep proper footing and balance at all times. This
enables better control of the power tool in unexpected situations.
- Dress properly. Don’t wear loose clothing or jewelry. Keep your hair,
clothing, and gloves away from moving parts. Loose cloths, jewelry or
long hair can be caught in moving parts.
- If devices are provided for connection of dust extraction and collection
facilities, ensure these are connected and properly used. Use of dust
collection can reduce dust-related hazards.
AIR COMPRESSOR
6
POWER TOOL USE AND CARE
- Don’t force the power tool. Use the correct power tool for your
application. The correct power tool will do the job better and safer at the
rate for which it was designed.
- Don’t use the power tool if the switch doesn’t turn it on and off. Any
power tool that cannot be controlled with the switch is dangerous and
must be repaired.
- Disconnect the plug from the power source and/or the battery pack from
the power tool before making any adjustments, changing accessories,
or storing power tools. Such preventive safety measures reduce the risk
of starting the power tool accidentally.
- Store idle power tools out of the reach of children and don’t allow
persons unfamiliar with power tool or these instructions to operate the
power tool. Power tools are dangerous in the hands of untrained users.
- Maintain power tools. Check for misalignment or binding of moving
parts, breakage o parts and any other condition that may affect the
power tool’s operation. If damaged, have the power tool repaired before
use. Many accidents are caused by poorly maintained power tools.
- Keep cutting tools sharp and clean. Properly maintained cutting tools
with sharp cutting edges are less likely to bind and are easier to control.
- Use the power tool, accessories and tool bits etc. in accordance with
the instruction, taking into account the working conditions and the work
to be performed. Use of the power tool for operations different from
those intended could result in a hazardous situation.
SERVICE
- Have your power tool serviced by qualified repair person using only
identical replacement parts. This will ensure that the safety of power tool
is maintained.
- Follow instruction for lubricating and changing accessories.
- Keep handles dry, clean and free from oil and grease.
USER MANUAL 7
AIR COMPRESSOR USE AND CARE
- Do not exceed the pressure rating of any component in the system.
- Protect material lines and air lines from damage or puncture. Keep
hose and power cird away from sharp objects, chemical spills, oil,
solvents, and wet floors.
- Check the tank before each use, making, certain all connections are
secure. Do not use if defect is found.
- Release all pressures within the system slowly. Dust and debris may
be harmful.
- Store idle air compressors out of the reach of children and other
untrained persons. Air compressors are dangerous in the hands of
untrained users.
- Maintain air compressors with car. Follow maintenance instructions.
Properly maintained products are easier to control.
- Check for misalignment or binding of moving parts, breakage of
parts, and any other condition that may affect the product’s operation.
If damaged, have the air compressor serviced before using. Many
accidents are caused by poorly maintained products.
- Keep the exterior of the air compressor dry, clean and free from oil and
free from oil and grease. Always use a clean cloth when cleaning. Never
use break fluids, gasoline, petroleum- based products, or any strong
solvents to clean the unit.
- Following this rule will reduce the risk of deterioration of the enclosure plastic.
.SPECIAL SAFETY RULES
- Know your air compressor. Read operator’s manual carefully. Learn
its applications and limitations, as well as the specific potential hazards
related to this product. Following this rule will reduce the risk of electric
shock, fire or serious injury.
- Drain tanks of moisture after each day’s use. If unit will not be used for a while,
it is best to leave drain valve open unit such time as it to be used. This will allow
moisture to completely drain out and help prevent corrosion on the inside of tanks.
AIR COMPRESSOR
8
- Risk of fire or explosion. Do not spray flammable liquid in a confined
area must be well ventilated Do not smoke while spraying or spray where
spark or flame is present. Keep compressors as far from the sparing
arras as possible, at least 4.5m (15 feet) from the spraying area and all
explosive vapors.
- Risk of bursting. Do not adjust regulator to result in output pressure
greater than marked maximum pressure of attachment. Do not use at
pressure greater than 10 bar.
- If connected to a circuit protected by fuses, use time delay fuses with
this product.
- To reduce the risk of electric shock, do not expose to rain. Store indoors.
- Inspect tanks yearly for rust, pin holes, or other imperfections that
could cause it to become unsafe.
- Never weld or drill holes in the air tanks.
- Make sure the hose is free of obstructions or sangers.
- Entangled or snarled hoses can cause loss of balance or footing and
may become damaged.
- Use the air compressor only for its intended use. Do not alter or modify
the unit from the original design or function.
- Always be aware that misuse and improper handling of this product
can cause injury to yourself and others.
- Never leave a tool unattended with the air hose attached.
- Never point any air tool toward yourself or others.
- Do not operate this air compressor if it does not contain a legible
warning label.
- Do not continue to use a tool or hose that leaks air or does not function properly.
- Always disconnect the air supply and power supply before making
adjustments, servicing a product, or when a product is not in use.
- Your tool may require more air consumption than this air compressor
is capable providing.
- Always follow all safety rules recommended by the manufacturer
of your air tool, in addition to all safety rules for the air compressor.
Following this rule will reduce the risk of serious personal injury.
USER MANUAL 9
- Never direct a jet of compressed air toward people or animals. Take
care not to blow dust and dirt towards yourself or others. Flowing this
rule will reduce the risk of serious injury.
- Do not use this air compressor to spray chemicals.
- Your lungs can be necessary in dusty environments or when spraying
paint. Do not carry while painting.
- Never use an electrical adaptor with this grounded plug.
- Check damaged parts. Before further use of the air compressor or air
tool, a guard or other part that is damaged should be carefully checked
to determine that it will operate properly and perform its intended
function. Check for alignment of moving parts, binding of moving parts,
breakage of parts, mountings and any other conditions that may affect,
its operation. A guard or other part that is damaged should be properly
repaired or replaced by an authorized service center.
- Following this rule will reduce the risk of shock, fire, or serious injury.
- Make sure your extension cord is in good condition. When using an
extension cord, sure to use one heavy enough to carry the current your
product will draw. A wire gauge size (A.W.G) of at least 14 is recommended
for an extension cord 7.5 m or less in length. A cord exceeding 15 m is
not recommended. If in doubt, use the next heavier gauge. The smaller
the gauge number, the heavier the cord. An undersized cord will cause
a drop in line voltage resulting in loss of power and overheating.
- This equipment incorporates parts, such as snap switches, receptacles,
and the like that tend to produce arcs or sparks and, therefore, when
located in a garage, it should be in a room or enclosure provided for the
purpose, or should be 460mm or more above the floor.
- Never store a tool with air connected. Storing the tool with air connected
can result in unexpected firing and possible serious personal injury.
- Protect your lungs. Wear a face or dust mask if the operation is dusty.
Following this rule will reduce the risk of serious personal injury.
- If the power supply cord is damaged, it must be replaced only by the
manufacture or by an authorized service center to avoid risk.
- Save these instructions. Refer to them frequently and use them to
AIR COMPRESSOR
10
instruct others who may use this product.
- If you loan someone this product, loan them these instructions also.
- The machine shall be connected to a circuit protection device (fuse
or circuit breaker). The protection device shall be set at 8 A current,
and the use shall do necessary test according to clause 18.2.2 of EN
60204-1:2006 to check if the protection device is suitable for use.
- When the machine is in operation, many parts of machine may cause
a high temperature. Use as gloves to avoid injuries resulting from a
high temperature.
This appliance is not intended for use by persons (including children) with
reduced Physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance.
ASSEMBLY
.UNPACKING
This product requires assembly. Carefully remove the product and any
accessories from the box.
WARRNING!
This product requires assembly. Carefully remove the product and any
accessories from the box.
WARRNING!
Do not use this product if any parts on the packing list are already
assembled to your product when you unpack it. Use of a product that may
have been improperly assembled could result in serious personal injury.
Inspect the product carefully to make sure no breakage or damage
occurred during shipping.
Do not discard the packing material unit you have carefully inspected
and satisfactorily operated the product.
USER MANUAL 11
WARRNING!
If any parts are damaged or missed, do not operate this product until the
parts are replaced. Use of this product with damaged or missing parts
could result in serious personal injury.
WARRNING!
Do not attempt to modify this product or create accessories not
recommended for use with this product. Any such alteration or
modification is misuse and could result in a hazardous condition leading
to possible serious personal injury.
WARRNING!
Do not connect to power supply until assembly is complete. Failure
to comply could result in accidental starting and possible serious
personal injury.
.CHECKING THE OIL
Always check the oi; when the unit is sitting on a level surface and before
first use.
1) The sight glass is located above the tank. There is a red dot in the
center of the glass.
2) An oil level at the top of the red dot indicates oil is at maximum level.
3) An oil level at or below the bottom of the red dot indicates oil is below
desired level, and oil should be added
AIR COMPRESSOR
12
To Add Oil:
1) Unscrew the cap of oil fill hole.
2) Using a funnel, carefully pour oil into the oil fill hole.
3) Tighten the cap securely into the oil fill hole.
NOTE:
Avoid too much oil. Ensure that the level of the oil does not exceed the
top of red dot at sight glass.
APPLICATIONS
Air compressors are utilized in a variety of air variety of air system
applications. Match hoses, connectors, air tools, and accessories to the
capabilities of the air compressor.
You may use this product for the purposes listed below:
- Operating some air-powered tools
- Operating air accessories such as air nozzles and tire inflators.
.TO MOVE THE AIR COMPRESSOR
Ensure the air compressor is unplugged, make sure the power cord is
secured in the cord warp.
1) Facing the back of the air compressor, grasp the handle firmly with
two hands.
2) Life the air compressor toward you until it balances on the wheels.
3) Push the unit along to the desired location.
Lower their air compressor unit it sits securely on a flat surface.
USER MANUAL 13
.BREAK- IN PERIOD
Before first use, run the air compressor at zero tank pressure with the
drain valves fully open for 30minutes.
.TURNING THE AIR COMPRESSOR ON/OFF
1) With the air compressor plugged in, pull the power switch to the ON
position to power the compressor on.
2) To turn the air compressor off, push the power switch to the OFF position.
NOTE:
When the compressor is in the ON position, the air compressor will
automatically turn back on when the designated tank air pressure limit.
It will also shut off again when the desired limit. It will also shut off again
when the desired pressure is reached.
WARNING!
Never exceed the air tool’s pressure rating as recommended by
the manufacturer. When using this air compressor as an inflation
device, always follow the maximum inflation guidelines stated by the
manufacturer of the item being inflated.
WARNING!
Always ensure the switch is in the OFF (O) position and the regulator
pressure gauge reads zero before changing air outlet. Failure to do so
could result in possible serious personal injury.
AIR COMPRESSOR
14
USING THE AIR COMPRESSOR
1) Ensure power switch is in OFF (O) position and air compressor is unplugged.
2) If not already installed, attach hose to compressor
3) Attach 6.35 mm (1/4 in.) NPT quick- connect air fitting to accessory
or tool you intend to use.
4) Insert the other end of the quick connect air fitting to the quick coupler
on the open end of hose.
5) Connect the power cord to the power supply.
6) Turn the switch ON (1).
7) Pull out and rotate pressure regulator knob to desired line pressure
at the outlet; turning counterclockwise regulator knob to desired line
pressure. Turning the knob clockwise increases air pressure at the
outlet; turning counterclockwise reduces air pressure at the outlet.
8) Following all safety precautions in the air tool manual. You may now
proceed to use your air-powered tool.
WARNING!
Air-powered tools may require more air consumption than this air
compressor is capable of providing. Check the tool manual to avoid
damage to the tool or risk of personal injury.
1) Control the amount of air flow with the pressure regulator knob.
Turning the knob fully counterclockwise will completely stop the flow
of air.
USER MANUAL 15
NOTE:
Always use the minimum amount of pressure necessary for your
application. Using a higher pressure than needed will drain air from the
tank more rapidly and cause the unit to cycle on more frequently.
1) When finished, always drain the tank and unplug the unit. Never leave
the unit plugged in and/or running unattended.
2) Recommended for the use of a residual current device with a rated
residual current of 30mA or less.
DRAINING THE TANKS
To help prevent tank corrosion and keep moisture out of the air, used,
the air tanks of the compressor should be drained daily.
.TO DRAIN
1) Turn the air compressor off.
2) Pull the ring on the pressure relief valve to release until pressure
gauge reads less than 1.4 bar.
3) Release the ring.
4) Rotate drain valves counterclockwise to open.
5) Tilt tank drain moisture tank into a suitable container.
NOTE:
Condensate is a polluting material and should be disposed of in
compliance with local regulations.
1) If drain valves are clogged, release all air pressure, remove and clean
valves, then reinstall.
AIR COMPRESSOR
16
DANGER!
Unplug the air compressor and release all air from the tanks before
servicing. Failure to depressurize tanks before attempting to remove
valve cause serious personal injury.
Rotate drain valves clockwise until tightly closed.
CHECKING THE SAFETY VALVE
WARNING!
Do not attempt to tamper with the safety valve.
Anything loosened from this device could fly up and hit you. Failure to
heed this warning could result death or serious personal injury.
The safety valve will automatically release air if the air tank pressure
exceeds the preset maximum. The valve should be checked before
each day of use by pulling the ring by hand.
1) Turn the air compressor on and allow the tanks to fill. The compressor
will shut off when the pressure reaches the preset maximum.
2) Turn the air compressor off.
3) Pull the ring on the safety valve to release air for three to five seconds.
4) The ring pin must be pushed back into position to stop the flow so air
at high pressure.
WARNING!
If air leaks after the ring has been released, or if the valve is stuck and
cannot be actuated by the ring, do not use the air compressor until
the safety valve has been replaced. Use of the air compressor in this
condition could result in serious personal injury.
MAINTENANCE
WARNING!
When servicing use only identical replacement parts.
Use of any other parts may create a hazard or cause product damage.
USER MANUAL 17
WARNING!
Always wear eye protection with side shields. Failure to do so could result
in objects being thrown into your eyes resulting in possible serious injury.
WARNING!
Always release all pressure, all pressure, disconnect from power supply,
and allow unit to cool to the touch before cleaning or making repairs on
the air compressor.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most plastics are
susceptible to damage from various types of commercial solvents and
be damaged by their use.
Use clean cloths to remove sort, dust, oil, grease, etc.
AS a routine part of air compressor maintenance, it is also advised that
the oil is routinely checked for proper levels.
WARNING!
Do not at any time let brake fluids, gasoline, petroleum- based products,
penetrating oils, etc., come in contact with plastic parts, Chemicals can
damage, weaken or destroy plastic which may result in serious personal injury.
Electric tools used on fiberglass material, wallboard, speckling compounds,
or plaster are subject to accelerated wear and possible premature failure
because the fiberglass chips and grindings are highly abrasive to bearings,
brushes, commutators, etc. Consequently, we do not recommend using
this product for extended work on these types of materials.
However, if you do work with any of these materials, it is extremely
important to clean the product using compressed air.
.BEARING LUBRICATION
All of the bearings in this product are lubricated with a sufficient amount
of high grade lubricant for the life of the unit under normal operating
conditions. Therefore, no further lubrication is required.
AIR COMPRESSOR
18
.REPLAING THE AIR FILTER
1) Turn the air filter cover counterclockwise approximately one- quarter turn.
2) Remove the cover
3) Remove the air filter.
4) Install new air filter.
5) Replace the air filter cover and secure it by turning it clockwise.
.CHANGING THE OIL
Replace the oil after the first 10 hours of operation and every 100 hours
following the oil change.
The sight glass, located above the tank, indicates the oil level and lets
the operator see at a glance if oil should be added.
1) Place as suitable container underneath the drain to collect used oil.
2) Remove the drain plug with an 8 mm socket or wrench.
3) When the used oil has drained, reinstall the drain plug and tighten
with the wrench.
4) Unscrew the cap of oil fill hole.
5) To refill, use a funnel to pour oil into the hole. Refill only with synthetic
oil fil SAE 5W40.
NOTE:
Avoid refilling with too much oil. Ensure that the level of the oil does not
exceed the top of the red dot at sight glass. The recommended amount
of oil for refilling is 250ml.
1) Tighten the cap securely into the fill hole.
USER MANUAL 19
.ENVIRONMENTAL PROTECTION
Recycle raw materials instead of disposing of as waste. The machine,
accessories and packaging should be sorted for environmental-friendly
recycling.
.TROUBLESHOOTING
PROBLM CAUSE POSSIBLE SOLUTION
Compressor will
not run
Loss of power or
overheating
Check for proper use of
extension cord
NO electrical power Check to be sure unit is
plugged in
Blown shop/house fuse Check fuse/ breaker
Shop/house breaker open Replace shop/house blow
fuse
Current limiting protector
open
Reset shop/house
breaker, determine why
problem happened
Pressure switch bad Motor will restart when
cool
Tank is full of air
Compressor will tum on
when tank
Pressure drops to cut- in
pressure
Motor hums but
cannot run or runs
slowly
Low voltage Check with voltmeter
Wrong gauge wire or
length of extension cord
Check for proper gauge
wire and cord length
Shorted or open motor
winding
Take compressor to
service center
Defective check valve or
unloader
Take compressor to
service center
Current limiting
protector
Protector cuts out
repeatedly
LOW voltage Check with voltmeter
Lack of proper ventilation/
room temperature too
high
Move compressor to
well- ventilated area
Wrong gauge wire or
length of extension cord
Check for proper gauge
wire and cord length
AIR COMPRESSOR
20
Air tank pressure
drops when
compressor shuts
off
Loose connections (fitting
, tubing, etc.)
Check all connection with
soap and water solution
and tighten
Loose drain valve Tighten drain valve
Check valve leaking
Take compressor to
service center
DANGER
Do not disassemble check
valve, tank drain valves or
safety relief valve with air
in tank- bleed tanks.
Excessive
moisture in
Discharge air
Excessive water in air
tanks Drain tanks
High humidity Move to area of less
humidity; use air-line filter
Compressor runs
continuously
Defective pressure switch Take compressor to
service center
Excessive air usage Take compressor to
service center
Piston ring are worn
Decrease air usage;
compressor not
Large enough for tools
requirement
Replace piston rings;
Air intel filter is blocked,
call customer service for
assistance
Air output lower
than normal
Broken inlet valves Tack compressor to
service center
Connections leaking Tighten connections
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Ronix RC-8010 User manual

Category
Power tools
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI