INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following product:
LEDFRA9
SAFETY
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this product is fitted) does not exceed the rating of
the circuit cable, fuse, or circuit breaker
• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
• Do not overload this accessory or subject it to conditions outside its rating
• This product is Class III
• This product is IP20 rated
INSTALLATION
• Provide power to the required point of installation
• Position controller inbetween the LED driver and LED flex
• Ensuring correct polarity is observed, connect the secondary side of the LED driver to the primary side
of the LED controller [(+ Red) (- Black)] (see Fig. 1)
• Terminate the 12V or 24V LED flex to the secondary side of the controller: the positive from the LED
flex to V+, Red to R, Green to G and Blue to B (see Fig. 1)
Fig. 1
• Ensure the LED flex does not exceed the maximum wattage of the controller
12V LED flex – up to 72W
24V LED flex – up to 144W
• Switch on and check for correct operation
Note – This product is able to operate at either 12V or 24V. The appropriate driver output voltage should be
selected to match the input voltage requirements of the LED load
Fig. 1