1.SET indicator 10.Central heating ON indicator
2.Time of day 11.SET positions
3.Switch Period symbol 12.PROGRAMME positions
4.SET Button 13.BOOST symbol
5.Hot water BOOST or adjust (-) button 14.ADVANCE symbol
6.Central heating ADVANCE or adjust (+) button 15.AM/PM symbol
7.Hot water (HW) select or ENTER Button 16.Day of week indicator
8.Central heating (CH) select or COPY button 17.PROGRAMME indicators
9.Hot water ON indicator
CCEENNTTAAUURRPPLLUUSS CC2277
UUSSEERR IINNSSTTRRUUCCTTIIOONNSS
QQUUEESSTTIIOONNSS AANNDD AANNSSWWEERRSS
The unit display has become frozen
The indicator neon fails to illuminate
on Hot water or Central heating
channel
The indicator neon will illuminate but
the pump and/or boiler fails to
operate
There is no display on the
programmer
How do I know if the programmer is
still under warranty
How is the programmer removed
from the wall
This could be due to local electrical interference
Using the RESET procedure may rectify the fault.
Using the RESET procedure may rectify the fault. If the problem persists the programmer will
need replacing.
This may indicate a problem elsewhere in your system;
E.g. A zone valve, etc. please contact a registered installer for advice.
Try the RESET procedure on page 2, if this fails to rectify the problem please have the mains
supply checked
The CentaurPlus range comes with a 2 year guarantee from the date of manufacture.
This date is located on the rear of the unit, indicated by a month over a year
WWAARRNNIINNGG::
The CentaurPlus programmer must only be removed from it’s backplate by either
a qualified electrician or heating engineer; The programmer plugs in to a 6 pin backplate
located on the rear of the unit and is secured using 2 screws located on the bottom surface
of the unit. Undo these screws and pull forward and up in an arc motion
LEAFLET No P60498
ISSUE 4
FRONT VIEW OF PROGRAMMER
PPaaggee 11
PPaaggee 44
TThhee ffoolllloowwiinngg aarree ssoommee ooff tthhee eeaassyy ttoo ooppeerraattee ffeeaattuurreess::--
FFlleexxiibbllee 77 DDaayy CCoonnttrrooll
11 HHoouurr BBoooosstt oonn HHoott WWaatteerr
IInnddeeppeennddeenntt ttiimmiinngg oonn HHoott WWaatteerr aanndd HHeeaattiinngg
CCeennttrraall HHeeaattiinngg AAddvvaannccee ggiivveess iinnssttaanntt OOnn//OOffff oovveerrrriiddee
UUpp ttoo 33 OOnn//OOffff ppeerriiooddss ppeerr cchhaannnneell iinn eeaacchh 2244HHrr ooppeerraattiioonn..
PPrrooggrraammmmee ooppttiioonnss:: AAuuttoo // AAllll ddaayy // 2244 HHoouurrss // OOffff
SSEERRVVIICCEE AANNDD RREEPPAAIIRR
This programmer is NOT user serviceable. Please do not dismantle the unit.
In the unlikely event of a fault developing please refer to the RESETTING THE PROGRAMMER section of
this user guide located on page 2. If this fails to resolve the problem please contact a local heating
engineer or a qualified electrician.
BBAATTTTEERRYY
The programmer is fitted with a non-rechargeable, long life battery, which will maintain the
programmed time settings for a minimum of ten months with the supply disconnected.
THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT.
During power interruptions the display will be blank, after 3 days the current time of day will be lost.
These measures are to prolong the battery life.
HHoorrssttmmaannnn’’ss CC2277 -- TTwwoo CChhaannnneell PPrrooggrraammmmeerr
Offers up to three
programmed operating periods per day, seven days a week,
with Hot water Boost and Heating Advance control on a fully
pumped system.
1
12
9
11
8
10
76
54
2
13
14
15
3
16
17
Horstmann Controls Limited
Bristol
BS4 1UP
Website: www.horstmann.co.uk