Dormakaba ED50/100/250 Surface Applied Installation guide

Type
Installation guide

This manual is also suitable for

ED50/ED100/ED250
Swing Door Operators
Narrow header
Installation Instructions
DL4616-005– 06-2023
| EN |
2ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Table of Contents
Table of contents
General information
. General information
Product overview
. Maximum door weights and door
installation 
. Single door configuration examples
. Double door configuration examples
. Double egress door configuration
examples 
. DS ED surface applied (SA) Low
energy (LE) door configurations
.. DS ED surface applied (SA)
LE hardware
. DS ED surface applied (SA)
low energy (LE) door configurations 
.. DS ED surface applied (SA)
LE hardware 
. DS ED surface applied (SA)
low energy (LE) double egress door
configurations 
.. DS ED surface applied (SA)
LE double egress hardware 
. DS ED FE surface applied (SA)
full energy (FE) door configurations 
.. DS ED surface applied (SA)
FE hardware 
. DS ED surface applied (SA) full
energy (FE) double egress door
configurations 
... DS ED surface applied (SA)
FE double egress hardware 
. DS ED surface applied (SA)
full energy (FE) door configurations 
.. DS ED surface applied (SA)
FE hardware 
. DS ED surface applied (SA)
FE double egress door configurations 
.. DS ED surface applied (SA)
FE double egress hardware 
.  x  narrow header 
. ED/ED/ED operators 
. Screw packs 
. Axle extensions, ED/ED/ED 
. Push arm door stop - option 
. Kit, ED operator labels 
. Mode and Exit Only switch panel 
. Optional key switch panels 
. Hole plug kit 
. Push arm kits 
. Pull arm kits 
. Arm screw kits 
. Double door ED/ED/ED
operator cables 
Table of contents
Technical data 
. ED/ED/ED operator technical
data 
. ED operating specifications 
. ED/ED operating specifications 
. ED/ED torque overview 
ED/E/ED terminal board
interfaces 
. ED/ED/ED terminal board
interfaces 
Recommended tools and torque chart 
. Recommended tools 
. Standard tightening torque 
. Drill bits 
ED/ED/ED door signage 
. ED/ED full energy operator 
. ED/ED/ED low energy operator 
. Safety label, automatic swing doors 
. Safety label, low energy swing doors 
. Door signage, full energy single swing doors 
. Door signage, low energy single swing doors,
initiation of door operation 
. Door signage, full energy double swing
doors 
. Door signage, low energy double swing
doors 
Installation templates 
. Narrow header ( x ") – push arm
template 
. Narrow header ( x ") – deep push arm
installation template 
. Narrow header ( x ") – pull arm
template 
. Narrow header ( x ") – deep pull arm
template 
. Center hung pivot door, narrow header
( x "), push arm template 
. Center hung pivot door, narrow header
( x "), pull arm template 
3
ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Table of Contents
ED/ED/ED narrow header
installation 
. Installation preparation 
. Remove mounting plate from
ED/ED/ED operator 
. Single door header installation 
. Install Mode switch panel in header 
. Double door header installation 
ED/ED/ED operator
installation 
. Single door narrow header mounting plate
installation 
. Double door narrow header mounting
plate installation 
. Customer  Vac connection to
mounting plate terminal block 
. Double door header  Vac mounting
plate connection 
. Remove protective film strips from
ED operator 
. Install ED/ED operator on
mounting plate in header 
. Double door header ED/ED operator
installation 
. Install ED operator on mounting plate in
header 
. Double header ED operator installation 
. Connect cables to ED/ED/ED
operator 
. Double door header operator legend plate 
Pull arm installation 
. Pull arm installation 
. Pull arm assemblies 
. Deep pull arm hardware 
. Slide shoe assembly 
. Install hardware into track 
. Standard arm 
.7 Deep pull arm 
. Deep pull arm installation 
. Standard pull arm installation 
Push arm installation 
. Push arm installation templates 
. Push arm installation 
 ED/ED/ED Operator spring
tension 
. Set ED/ED/ED operator spring
tension 
 ANSI/BHMA standards 
. A. Power operated pedestrian doors 
. A. Low energy power operated doors 
 Install door signage 
. Install door signage 
 Cover, end caps and spindle caps 
. Cover end cap and spindle installation 
 Maintenance 
. Safety label, automatic swing doors 
. Safety label, low energy swing doors 
. Arm fasteners – torque requirements 
. ED brake maintenance 
Appendix A - Key switch wiring diagrams 
A. DX-C Key Switch Panel with
RJ connector 
A. DX-C Key Switch Panel 
Appendix B - Knowing act switch wiring 
diagrams 
B. Knowing act switches 
B. Knowing act switch wiring diagram 
4ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 1
.. Installation Instructions.
This manual provides installation instructions for the
following ED/ED/ED narrow header surface
applied door configurations.
Reference Para. . and . for illustrations.
Single doors.
. RH and LH pull.
. RH and LH push.
. RH and LH pull as push.
Double doors.
. Pull
. Push
. Pull as push.
. Double egress.
.. dormakaba.us website.
Manuals are available for review, download, and printing
on the dormakaba.us website.
.. Dimensions
Unless otherwise specified, all dimensions are given in
both inches (“) and [mm].
.. Building codes and standards.
ED/ED/ED narrow installation: observe
applicable national and local building codes.
General information
. General information
.. Symbols used in these instructions.
WARNING
This symbol warns of hazards which could result
in personal injury or threat to health.
CAUTION
This symbol warns of a potentially unsafe
procedure or situation.
NOTICE
Draws attention to important information
presented in this document.
TIPS AND RECOMMENDATIONS
Clarifies instructions or other information
presented in this document.
5
ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
Product overview
Table 2.1.1 ED50 low energy door panel
Exterior and interior applications
Prevailing conditions at opening must be considered
Maximum door width Pounds kg
" []  []
Table 2.1.2 ED100 low energy door panel
Exterior applications
Prevailing conditions at opening must be considered
Maximum door width Pounds kg
" []  []
Interior applications
Prevailing conditions at opening must be considered
Maximum door width Pounds kg
" []  []
Table 2.1.3 ED100 full energy door panel
Exterior and interior applications
Prevailing conditions at opening must be considered
Maximum door width Pounds kg
" []  []
Table 2.1.4 ED250 low energy door panel
Exterior applications
Prevailing conditions at opening must be considered
Maximum door width Pounds kg
" []  []
Interior applications
Prevailing conditions at opening must be considered
Maximum door width Pounds kg
" []  []
Table 2.1.5 ED250 full energy door panel
Exterior and interior applications
Prevailing conditions at opening must be considered
Maximum door width Pounds kg
" []  []
. Maximum door weights and door installation
.. ED/ED/ED narrow header exterior door
installation.
NOTICE
Exterior door use.
To insure proper suitability for exterior door
use, the following topics must be addressed in
the context of the door application setting.
For site-specific use factors such as high
wind conditions and/or building pressure
consult the factory.
Door width, height, weight, and usage
patterns.
Observable prevailing conditions at the
opening under which the operator is
expected to perform. In some instances, this
may require increased force settings to
counteract these conditions.
Door mounted presence sensors.
When attempting to overcome these forces,
it is strongly suggested that door mounted
presence sensors be employed to enhance
pedestrian safety through the opening.
.. Interior building surface installation.
NOTICE
Installation on an interior building surface.
The ED/ED/ED narrow header
must be installed on an interior building
surface.
6ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
Fig. 2.2.3 RH push
Fig. 2.2.1 RH pull Fig. 2.2.2 RH pull as a push
. Single door configuration examples
Fig. 2.3.1 Pull
. Double door configuration examples
Fig. 2.3.2 Push
Fig. 2.3.3 Pull as push
7
ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
Fig. 2.4.1 RH Double egress
. Double egress door configuration examples
8ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
Part number Description Finish
DS-A ED, SA LE Push LH CL Clear
DS-B ED, SA LE Push LH DB Dk Bronze
DS-E ED, SA LE Push LH Special
DS-A ED, SA LE Push RH CL Clear
DS-B ED, SA LE Push RH DB Dk Bronze
DS-E ED, SA LE Push RH Special
DS-A ED, SA LE Push Pair CL Clear
DS-B ED, SA LE Push Pair DB Dk Bronze
DS-E ED, SA LE Push Pair Special
Table 2.3.1 ED50 SA push arm door configurations
. DS ED surface applied (SA) Low energy (LE) door
configurations
Part number Description Finish
DS-A ED, SA LE Deep Push LH CL Clear
DS-B ED, SA LE Deep Push LH DB Dk Bronze
DS-E ED, SA LE Deep Push LH Special
DS-A ED, SA LE Deep Push RH CL Clear
DS-B ED, SA LE Deep Push RH DB Dk Bronze
DS-E ED, SA LE Deep Push RH Special
DS-A ED, SA LE Deep Push Pair CL Clear
DS-B ED, SA LE Deep Push Pair DB Dk Bronze
DS-E ED, SA LE Deep Push Pair Special
Table 2.3.2 ED50 SA deep push arm door configurations
Part number Description Finish
DS-A ED, SA LE Pull LH CL Clear
DS-B ED, SA LE Pull LH DB Dk Bronze
DS-E ED, SA LE Pull LH Special
DS-A ED, SA LE Pull RH CL Clear
DS-B ED, SA LE Pull RH DB Dk Bronze
DS-E ED, SA LE Pull RH Special
DS-A ED, SA LE Pull Pair CL Clear
DS-B ED, SA LE Pull Pair DB Dk Bronze
DS-E ED, SA LE Pull Pair Special
Table 2.3.3 ED50 SA pull arm door configurations
Part number Description Finish
DS-A ED, SA LE Deep Pull LH CL Clear
DS-B ED, SA LE Deep Pull LH DB Dk Bronze
DS-E ED, SA LE Deep Pull LH Special
DS-A ED, SA LE Deep Pull RH CL Clear
DS-B ED, SA LE Deep Pull RH DB Dk Bronze
DS-E ED, SA LE Deep Pull RH Special
DS-A ED, SA LE Deep Pull Pair CL Clear
DS-B ED, SA LE Deep Pull Pair DB Dk Bronze
DS-E ED, SA LE Deep Pull Pair Special
Table 2.3.4 ED50 SA deep pull arm door configurations
.. DS ED surface applied (SA) LE hardware
SAFETY INFORMATION
Low Energy Swinging
Doors
1
. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop withou
t
impact.
2
. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3
. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
5
. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE
2
SAFETY INFORMATION
Low Energy Swinging
Doors
1
. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop withou
t
impact.
2
. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3
. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
5
. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
1
Fig. 2.3.1.1 ED50 SA hardware
Reference Table .., next page.
9
ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
Fig. 2.3.1.1 ED50 SA hardware Table 2.3.1.1 ED50 SA hardware
6
Part number Description
LH RH PR
Item -x -x -x
DK- Kit, ED operator
label, LE single  
DK- Kit, ED operator
label, LE pair
DK- Screw package,ED
operator mounting   
DK- Plug package, x
header   
DK- Screw package, x
header mounting   
DK- Kit, ED operator
Reference Para. . for door arm configurations
. DK-_ Kit, Push arm
. DK-_ Kit, Deep push arm
. DK-_ Kit, Pull arm
. DK-_ Kit, Deep pull arm
DS-x x header
assembly LH
DS-x x header
assembly RH
 DS-x x header
assembly PR
 DX- ED power connect
cable  mm (pair)
 DX- ED sync cable 
mm (pair)
 DX-C Kit, mode switch
RJ  ft FRC   
 DX-
Communication
cable,  Deg, RJ
 ft
  
13
5
3
4
14
7.1
7.2
7.3
7.4
89
10
10 ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
. DS ED surface applied (SA) low energy (LE) door
configurations
Part number Description Finish
DS-A ED, SA LE Push LH CL Clear
DS-B ED, SA LE Push LH DB Dk Bronze
DS-E ED, SA LE Push LH Special
DS-A ED, SA LE Push RH CL Clear
DS-B ED, SA LE Push RH DB Dk Bronze
DS-E ED, SA LE Push RH Special
DS-A ED, SA LE Push Pair CL Clear
DS-B ED, SA LE Push Pair DB Dk Bronze
DS-E ED, SA LE Push Pair Special
Table 2.4.1 ED100 SA LE push arm door configurations
Part number Description Finish
DS-A ED, SA LE Deep Push LH CL Clear
DS-B ED, SA LE Deep Push LH DB Dk Bronze
DS-E ED, SA LE Deep Push LH Special
DS-A ED, SA LE Deep Push RH CL Clear
DS-B ED, SA LE Deep Push RH DB Dk Bronze
DS-E ED, SA LE Deep Push RH Special
DS-A ED, SA LE Deep Push Pair CL Clear
DS-B ED, SA LE Deep Push Pair DB Dk Bronze
DS-E ED, SA LE Deep Push Pair Special
Table 2.4.2 ED100 SA LE deep push arm door configurations
Part number Description Finish
DS-A ED, SA LE Pull LH CL Clear
DS-B ED, SA LE Pull LH DB Dk Bronze
DS-E ED, SA LE Pull LH Special
DS-A ED, SA LE Pull RH CL Clear
DS-B ED, SA LE Pull RH DB Dk Bronze
DS-E ED, SA LE Pull RH Special
DS-A ED, SA LE Pull Pair CL Clear
DS-B ED, SA LE Pull Pair DB Dk Bronze
DS-E ED, SA LE Pull Pair Special
Table 2.4.3 ED100 SA LE pull arm door configurations
Part number Description Finish
DS-A ED, SA LE Deep Pull LH CL Clear
DS-B ED, SA LE Deep Pull LH DB Dk Bronze
DS-E ED, SA LE Deep Pull LH Special
DS-A ED, SA LE Deep Pull RH CL Clear
DS-B ED, SA LE Deep Pull RH DB Dk Bronze
DS-E ED, SA LE Deep Pull RH Special
DS-A ED, SA LE Deep Pull Pair CL Clear
DS-B ED, SA LE Deep Pull Pair DB Dk Bronze
DS-E ED, SA LE Deep Pull Pair Special
Table 2.4.4 ED100 SA LE deep pull arm door configurations
SAFETY INFORMATION
Low Energy Swinging
Doors
1
. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop withou
t
impact.
2
. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3
. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
5
. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE
2
.. DS ED surface applied (SA) LE hardware
SAFETY INFORMATION
Low Energy Swinging
Doors
1
. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2
. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3
. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
5
. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
1
Fig. 2.4.1.1 ED100 SA LE hardware
Reference Table .., next page.
11
ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
Fig. 2.4.1.1 ED100 SA LE hardware Table 2.4.1.1 ED100 SA LE hardware
Part number Description
LH RH PR
Item -x -x -x
DK- Kit, ED operator
label, LE single  
DK- Kit, ED operator
label, LE pair
DK- Screw package,ED
operator mounting   
DK- Plug package, x
header   
DK- Kit, ED operator
DK- Screw package, x
header mounting   
Reference Para. . for door arm configurations
. DK-_ Kit, Push arm
. DK-_ Kit, Deep push arm
. DK-_ Kit, Pull arm
. DK-_ Kit, Deep pull arm
DS-x x header
assembly LH
DS-x x header
assembly RH
 DS-x x header
assembly PR
 DX- ED power connect
cable  mm (pair)
 DX- ED sync cable 
mm (pair)
 DX-C Kit, mode switch
RJ  ft FRC   
 DX-
Communication
cable,  Deg, RJ
 ft
  
 DS- Door stop assembly,
/" Push arm only   
13
6
3
4
14
5
89
10
7.1
7.2
7.3
7.4
15
12 ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
. DS ED surface applied (SA) low energy (LE) double egress
door configurations
Table 2.5.1 ED100 SA LE double egress door configurations
Part number Description Finish
DS-A ED, SA FE Double Egress CL Clear
DS-B ED, SA FE Double Egress DB Dk Bronze
DS-E ED, SA FE Double Egress Special
13
ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
Fig. 2.5.1.1 ED100 SA LE double egress hardware
.. DS ED surface applied (SA) LE double egress hardware
Item Part number Description
DK- Kit, ED operator label, LE single
DK- Kit, ED operator label, LE pair
DK- Screw package,ED operator mounting
DK- Plug package, x header
DK- Screw package, x header mounting
DK- Kit, ED operator
DK-_ Kit, Push arm
DK-_ Kit, Deep pull arm
DS-x x header assembly PR
 DS- Door stop assembly, /"
 DX- ED power connect cable  mm (pair)
 DX- ED sync cable  mm (pair)
 DX-C Kit, mode switch RJ  ft FRC
 DX- Communication cable,  Deg, RJ  ft
Table 2.5.1.1 ED100 SA LE double egress hardware
7
8
9
13
5
3
4
14
5
SAFETY INFORMATION
Low Energy Swinging
Doors
1
. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2
. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3
. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
5
. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE
2
SAFETY INFORMATION
Low Energy Swinging
Doors
1
. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2
. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3
. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
5
. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
1
14 ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
. DS ED FE surface applied (SA) full energy (FE) door
configurations
Part number Description Finish
DS-A ED, SA FE Push LH CL Clear
DS-B ED, SA FE Push LH DB Dk Bronze
DS-E ED, SA FE Push LH Special
DS-A ED, SA FE Push RH CL Clear
DS-B ED, SA FE Push RH DB Dk Bronze
DS-E ED, SA FE Push RH Special
DS-A ED, SA FE Push Pair CL Clear
DS-B ED, SA FE Push Pair DB Dk Bronze
DS-E ED, SA FE Push Pair Special
Table 2.6.1 ED100 SA FE push arm door configurations
Part number Description Finish
DS-A ED, SA FE Deep Push LH CL Clear
DS-B ED, SA FE Deep Push LH DB Dk Bronze
DS-E ED, SA FE Deep Push LH Special
DS-A ED, SA FE Deep Push RH CL Clear
DS-B ED, SA FE Deep Push RH DB Dk Bronze
DS-E ED, SA FE Deep Push RH Special
DS-A ED, SA FE Deep Push Pair CL Clear
DS-B ED, SA FE Deep Push Pair DB Dk Bronze
DS-E ED, SA FE Deep Push Pair Special
Table 2.6.2 ED100 SA FE deep push arm door configurations
Part number Description Finish
DS-A ED, SA FE Pull LH CL Clear
DS-B ED, SA FE Pull LH DB Dk Bronze
DS-E ED, SA FE Pull LH Special
DS-A ED, SA FE Pull RH CL Clear
DS-B ED, SA FE Pull RH DB Dk Bronze
DS-E ED, SA FE Pull RH Special
DS-A ED, SA FE Pull Pair CL Clear
DS-B ED, SA FE Pull Pair DB Dk Bronze
DS-E ED, SA FE Pull Pair Special
Table 2.6.3 ED100 SA FE pull arm door configurations
Part number Description Finish
DS-A ED, SA FE Deep Pull LH CL Clear
DS-B ED, SA FE Deep Pull LH DB Dk Bronze
DS-E ED, SA FE Deep Pull LH Special
DS-A ED, SA FE Deep Pull RH CL Clear
DS-B ED, SA FE Deep Pull RH DB Dk Bronze
DS-E ED, SA FE Deep Pull RH Special
DS-A ED, SA FE Deep Pull Pair CL Clear
DS-B ED, SA FE Deep Pull Pair DB Dk Bronze
DS-E ED, SA FE Deep Pull Pair Special
Table 2.6.4 ED100 SA FE deep pull arm door configurations
.. DS ED surface applied (SA) FE hardware
SAFETY INFORMATION
Low Energy Swinging
Doors
1
. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2
. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3
. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
5
. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
1.1
SAFETY INFORMATION
Automatic Swinging Doors
1. Walk toward the door at a
normal pace. The door
should open when you ar
e
about 4 feet from the door.
2. Stand motionless on
threshold for at least 10
seconds. The door should
not close.
3. Move clear of the area. The
door should remain open for
at least 1.5 seconds and
should close slowly and
smoothly.
4. Repeat steps 1 through 3
from other direction if door
is used for two way trac.
5. Inspect the oor area. It
should be clean with no
loose parts that might caus
e
user to trip or fall. Keep
trac path clear.
6. Inspect door's overall
condition. The appropriate
signage should be present.
7. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.10 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-2496
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0739-010
AUTOMATIC
DOOR
DO NOT
ENTER
AUTOMATIC
DOOR
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE
SAFETY INFORMATION
Low Energy Swinging
Doors
1
. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2
. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3
. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
5
. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
1.2
SAFETY INFORMATION
Automatic Swinging Doors
1
. Walk toward the door at a
normal pace. The door
should open when you are
about 4 feet from the door.
2
. Stand motionless on
threshold for at least 10
seconds. The door should
not close.
3
. Move clear of the area. The
door should remain open for
at least 1.5 seconds and
should close slowly and
smoothly.
4
. Repeat steps 1 through 3
from other direction if door
is used for two way trac.
5
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
6
. Inspect door's overall
condition. The appropriate
signage should be present.
7
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.10 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-2496
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0739-010
AUTOMATIC
DOOR
DO NOT
ENTER
AUTOMATIC
DOOR
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE
CAUTION
DOOR
AUTOMATIC
DD0586-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0739-010
AUTOMATIC
DOOR
DO NOT
ENTER
AUTOMATIC
DOOR
ACTIVATE SWITCH
TO OPERATE
ACTIVATE SWITCH
TO OPERATE
DD0758-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
Fig. 2.6.1.1 ED100 SA FE hardware
Reference Table .., next page.
15
ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
Fig. 2.6.1.1 ED100 SA FE hardware Table 2.10.1 ED100 SA FE hardware
10
4
2
3
11
5
17.1
7.2
7.3
7.4
Part number Description
LH RH PR
Item -x -x -x
. DK- Kit, ED operator
label, FE single  
. DK- Kit, ED operator
label, FE pair
DK- Screw package,ED
operator mounting   
DK- Plug package, x
header   
DK- Screw package, x
header mounting   
DK- Kit, ED operator
Reference Para. . for door arm configurations
. DK-_ Kit, Push arm
. DK-_ Kit, Deep push arm
. DK-_ Kit, Pull arm
. DK-_ Kit, Deep pull arm
DS-x x header
assembly LH
DS-x x header
assembly RH
 DS-x x header
assembly PR
 DX-C Kit, mode switch
RJ  ft FRC   
 DX-
Communication
cable,  Deg, RJ
 ft
  
 DX- ED power connect
cable  mm (pair)
 DX- ED sync cable 
mm (pair)
 DS- Door stop assembly,
/" Push arm only   
89
10
15
16 ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
. DS ED surface applied (SA) full energy (FE) double egress
door configurations
Table 2.7.1 ED100 SA FE double egress door configurations
Part number Description Finish
DS-A ED, SA FE Double Egress CL Clear
DS-B ED, SA FE Double Egress DB Dk Bronze
DS-E ED, SA FE Double Egress Special
17
ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
Fig. 2.7.1.1 ED100 SA FE double egress hardware
... DS ED surface applied (SA) FE double egress hardware
SAFETY INFORMATION
Low Energy Swinging
Doors
1
. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2
. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3
. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
5
. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE
2SAFETY INFORMATION
Automatic Swinging Doors
1
. Walk toward the door at a
normal pace. The door
should open when you are
about 4 feet from the door.
2
. Stand motionless on
threshold for at least 10
seconds. The door should
not close.
3
. Move clear of the area. The
door should remain open for
at least 1.5 seconds and
should close slowly and
smoothly.
4
. Repeat steps 1 through 3
from other direction if door
is used for two way trac.
5
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
6
. Inspect door's overall
condition. The appropriate
signage should be present.
7
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Au tomatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.10 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-2496
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0739-010
AUTOMATIC
DOOR
DO NOT
ENTER
AUTOMATIC
DOOR
DD0739-010
AUTOMATIC
DOOR
DO NOT
ENTER
AUTOMATIC
DOOR
Item Part number Description
DK- Kit, ED operator label, FE single
DK- Kit, ED operator label, FE pair
DK- Screw package,ED operator mounting
DK- Plug package, x header
DK- Screw package, x header mounting
DK- Kit, ED operator
DK-_ Kit, Push arm
DK-_ Kit, Deep pull arm
DS-x x header assembly PR
 DS- Door stop assembly, /"
 DX- ED power connect cable  mm (pair)
 DX- ED sync cable  mm (pair)
 DX-C Kit, mode switch RJ  ft FRC
 DX- Communication cable,  Deg, RJ  ft
Table 2.7.1.1 ED100 SA FE double egress hardware
7
8
9
13
5
3
4
14
6
18 ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
. DS ED surface applied (SA) full energy (FE) door
configurations
Part number Description Finish
DS-A ED, SA FE Push LH CL Clear
DS-B ED, SA FE Push LH DB Dk Bronze
DS-E ED, SA FE Push LH Special
DS-A ED, SA FE Push RH CL Clear
DS-B ED, SA FE Push RH DB Dk Bronze
DS-E ED, SA FE Push RH Special
DS-A ED, SA FE Push Pair CL Clear
DS-B ED, SA FE Push Pair DB Dk Bronze
DS-E ED, SA FE Push Pair Special
Table 2.8.1 ED250 SA FE push arm door configurations
Part number Description Finish
DS-A ED, SA FE Deep Push LH CL Clear
DS-B ED, SA FE Deep Push LH DB Dk Bronze
DS-E ED, SA FE Deep Push LH Special
DS-A ED, SA FE Deep Push RH CL Clear
DS-B ED, SA FE Deep Push RH DB Dk Bronze
DS-E ED, SA FE Deep Push RH Special
DS-A ED, SA FE Deep Push Pair CL Clear
DS-B ED, SA FE Deep Push Pair DB Dk Bronze
DS-E ED, SA FE Deep Push Pair Special
Table 2.8.2 ED250 SA FE deep push arm door configurations
Part number Description Finish
DS-A ED, SA FE Pull LH CL Clear
DS-B ED, SA FE Pull LH DB Dk Bronze
DS-E ED, SA FE Pull LH Special
DS-A ED, SA FE Pull RH CL Clear
DS-B ED, SA FE Pull RH DB Dk Bronze
DS-E ED, SA FE Pull RH Special
DS-A ED, SA FE Pull Pair CL Clear
DS-B ED, SA FE Pull Pair DB Dk Bronze
DS-E ED, SA FE Pull Pair Special
Table 2.8.3 ED250 SA FE pull arm door configurations
Part number Description Finish
DS-A ED, SA FE Deep pull LH CL Clear
DS-B ED, SA FE Deep Pull LH DB Dk Bronze
DS-E ED, SA FE Deep Pull LH Special
DS-A ED, SA FE Deep Pull RH CL Clear
DS-B ED, SA FE Deep Pull RH DB Dk Bronze
DS-E ED, SA FE Deep Pull RH Special
DS-A ED, SA FE Deep Pull Pair CL Clear
DS-B ED, SA FE Deep Pull Pair DB Dk Bronze
DS-E ED, SA FE Deep Pull Pair Special
Table 2.8.4 ED250 SA FE deep pull arm door configurations
.. DS ED surface applied (SA) FE hardware
SAFETY INFORMATION
Low Energy Swinging
Doors
1
. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2
. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3
. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
5
. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
1.1
SAFETY INFORMATION
Automatic Swinging Doors
1. Walk toward the door at a
normal pace. The door
should open when you ar
e
about 4 feet from the door.
2. Stand motionless on
threshold for at least 10
seconds. The door should
not close.
3. Move clear of the area. The
door should remain open for
at least 1.5 seconds and
should close slowly and
smoothly.
4. Repeat steps 1 through 3
from other direction if door
is used for two way trac.
5. Inspect the oor area. It
should be clean with no
loose parts that might caus
e
user to trip or fall. Keep
trac path clear.
6. Inspect door's overall
condition. The appropriate
signage should be present.
7. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.10 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-2496
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0739-010
AUTOMATIC
DOOR
DO NOT
ENTER
AUTOMATIC
DOOR
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE SAFETY INFORMATION
Low Energy Swinging
Doors
1
. Activate the door. Door
should open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2
. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3
. Door should close at a slow,
smooth pace (4 or more
seconds), and stop without
impact.
4
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
5
. Inspect door‘s overall
condition. The appropriate
signage should be present
and the hardware should
be in good condition.
6
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.19 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-3044
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0758-010
ACTIVATE SWITCH
TO OPERATE
DD0758-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
1.2
SAFETY INFORMATION
Automatic Swinging Doors
1
. Walk toward the door at a
normal pace. The door
should open when you are
about 4 feet from the door.
2
. Stand motionless on
threshold for at least 10
seconds. The door should
not close.
3
. Move clear of the area. The
door should remain open for
at least 1.5 seconds and
should close slowly and
smoothly.
4
. Repeat steps 1 through 3
from other direction if door
is used for two way trac.
5
. Inspect the oor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
trac path clear.
6
. Inspect door's overall
condition. The appropriate
signage should be present.
7
. Have door inspected by an
AAADM certied inspector
at least annually.
AAADM
American Association of Aut omatic
Door Manufacturers
ANNUAL COMPLIANCE
INSPECTION
INSPECT FOR AND
COMPLIES WITH ANSI
A156.10 ON:
DATE:______________
by AAADM Certified
Inspector
Number:___________
AAADM-2496
DO NOT USE DOOR if it fails
any of these safety checks of if
it malfunctions in any way. Call
a qualied automatic door
service company to have door
repaired or serviced.
See Owner’s manual or
instructions for details on
each of these and other
safety items. If you need
a copy of the manual,
contact the manufacturer.
These minimum safety checks, in
addition to those in the Owner’s
Manual, should be made each
day and after any loss of
electrical power.
DD0739-010
AUTOMATIC
DOOR
DO NOT
ENTER
AUTOMATIC
DOOR
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0758-010
ACTIVATE SWITCH
TO OPERATE
CAUTION
DOOR
AUTOMATIC
DD0586-010
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0739-010
AUTOMATIC
DOOR
DO NOT
ENTER
AUTOMATIC
DOOR
ACTIVATE SWITCH
TO OPERATE
ACTIVATE SWITCH
TO OPERATE
DD0758-010
DD0762-020
PULL
TO OPERATE
DD0762-010
PUSH
TO OPERATE
Fig. 2.8.1.1 ED250 SA FE hardware
Reference Table .., next page.
19
ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
Fig. 2.8.1.1 ED250 FE SA hardware
Part number Description
LH RH PR
Item -x -x -x
. DK- Kit, ED operator
label, FE single  
. DK- Kit, ED operator
label, FE pair
DK- Screw package,ED
operator mounting   
DK- Plug package, x
header   
DK- Screw package, x
header mounting   
DK- Kit, ED operator
Reference Para. . for door arm configurations
. DK-_ Kit, Push arm
. DK-_ Kit, Deep push arm
. DK-_ Kit, Pull arm
. DK-_ Kit, Deep pull arm
. DS-x x header
assembly LH
. DS-x x header
assembly RH
. DS-x x header
assembly PR
DX- ED power connect
cable  mm (pair)
DX- ED sync cable 
mm (pair)
 DX-C Kit, mode switch
RJ  ft FRC   
 DX-
Communication
cable,  Deg, RJ
 ft
  
 DS- Door stop assembly,
/" Push arm only   
Table 2.8.1.1 ED250 FE SA hardware
6.1
6.2
6.3
6.4
5
10
4
2
3
11
7.1 7.2
7.3
12
20 ED50/ED100/ED250 06-2023DL4616-005
ED narrow header Installation Instructions Chapter 2
. DS ED surface applied (SA) FE double egress door
configurations
Table 2.9.1 ED250 SA FE double egress door configurations
Part number Description Finish
DS-A ED, SA FE Double Egress CL Clear
DS-B ED, SA FE Double Egress DB Dk Bronze
DS-E ED, SA FE Double Egress Special
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80

Dormakaba ED50/100/250 Surface Applied Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI