ESAB 2RT Transmig Wire Feeder User manual

Category
Welding System
Type
User manual
300
Operating Manual
Revision: AB Issue Date: June 15, 2012 Manual No.: 0-5196
Operating Features:
TRANSMIG
WIRE FEEDER
2RT
WE APPRECIATE YOUR BUSINESS!
Congratulations on your new Cigweld product. We are proud
to have you as our customer and will strive to provide you with
the best service and reliability in the industry. This product is
backed by our extensive warranty and world-wide service net-
work. To locate your nearest distributor or service agency call
+1300 654 674, or visit us on the web at www.victortechnologies.com
This Operating Manual has been designed to instruct you on the correct
use and operation of your CIGWELD product. Your satisfaction with this
product and its safe operation is our ultimate concern. Therefore please
take the time to read the entire manual, especially the Safety Precau-
tions. They will help you to avoid potential hazards that may exist when
working with this product.
We have made every effort to provide you with accurate instructions,
drawings, and photographs of the product(s) while writing this manual.
However errors do occur and we apologize if there are any contained in
this manual.
Due to our constant effort to bring you the best products, we may make
an improvement that does not get refl ected in the manual. If you are ever
in doubt about what you see or read in this manual with the product you
received, then check for a newer version of the manual on our website
or contact our customer support for assistance.
YOU ARE IN GOOD COMPANY!
The Brand of Choice for Contractors and Fabricators Worldwide.
CIGWELD is the Market Leading Brand of Arc Welding Products for Victor
Technologies, Inc. We are a mainline supplier to major welding industry
sectors in the Asia Pacifi c and emerging global markets including; Manu-
facturing, Construction, Mining, Automotive, Engineering, Rural and DIY.
We distinguish ourselves from our competition through market-leading,
dependable products that have stood the test of time. We pride ourselves
on technical innovation, competitive prices, excellent delivery, superior
customer service and technical support, together with excellence in sales
and marketing expertise.
Above all, we are committed to develop technologically advanced prod-
ucts to achieve a safer working environment for industry operators.
!
WARNINGS
Read and understand this entire Manual and your employer’s safety practices before installing,
operating, or servicing the equipment.
While the information contained in this Manual represents the Manufacturer’s best judgement,
the Manufacturer assumes no liability for its use.
Operating Manual Number 0-5196 for:
Cigweld Transmig 2RT Wirefeeder Part Number W3000500
Published by:
Victor Technologies, Inc.
82 Benning Street
West Lebanon, New Hampshire, USA 03784
(603) 298-5711
www.victortechnologies.com
Copyright 2011, 2012 by
Victor Technologies, Inc.
All rights reserved.
Reproduction of this work, in whole or in part, without written permission of the publisher is
prohibited.
The publisher does not assume and hereby disclaims any liability to any party for any loss
or damage caused by any error or omission in this Manual, whether such error results from
negligence, accident, or any other cause.
Publication Date: October 25, 2011
Revision Date: June 15, 2012
Record the following information for Warranty purposes:
Where Purchased: ____________________________________
Purchase Date: ____________________________________
Equipment Serial #: ____________________________________
TABLE OF CONTENTS
SECTION 1: ARC WELDING SAFETY INSTRUCTIONS AND WARNINGS ............................. 1-1
1.01 Arc Welding Hazards ....................................................................................... 1-1
1.02 Principal Safety Standards .............................................................................. 1-5
1.03 Declaration of Conformity ............................................................................... 1-6
SECTION 2: INTRODUCTION ............................................................................. 2-1
2.01 How to Use This Manual ................................................................................. 2-1
2.02 Equipment Identifi cation ................................................................................. 2-1
2.03 Receipt of Equipment ...................................................................................... 2-1
2.04 Symbol Chart .................................................................................................. 2-2
2.05 Description ..................................................................................................... 2-3
2.06 User Responsibility ......................................................................................... 2-3
2.07 Transportation Methods .................................................................................. 2-3
2.08 Packaged Items .............................................................................................. 2-3
2.09 Specifi cations ................................................................................................. 2-4
SECTION 3: INSTALLATION OPERATION AND SETUP ................................................. 3-1
3.01 Environment ................................................................................................... 3-1
3.02 Location .......................................................................................................... 3-1
3.03 Ventilation ....................................................................................................... 3-1
3.04 Mains Supply Voltage Requirements .............................................................. 3-1
3.05 Electromagnetic Compatibility ........................................................................ 3-1
3.06 2RT Wire Feeder Controls, Indicators and Features ........................................ 3-3
3.07 Transmig 250i Power Source Controls, Indicators and Features ..................... 3-5
3.08 Advanced Features Details .............................................................................. 3-7
3.09 Wire Feeder Set Up MIG (GMAW) Welding with Gas Shielded MIG Wire ........ 3-8
3.10 Wire Feeder Set-up for MIG (FCAW) Welding with Gasless MIG Wire ............ 3-9
3.11 Attaching the Tweco Professional MIG Torch (Euro) ..................................... 3-10
3.12 Installing a Handi Spool (200mm diameter) ................................................. 3-11
3.13 Installing a Standard Spool (300mm diameter) ............................................ 3-12
3.14 Inserting Wire into the Feed Mechanism ...................................................... 3-13
3.15 Feed Roller Pressure Adjustment .................................................................. 3-14
3.16 Feed Roller Alignment ................................................................................... 3-14
3.17 Changing the Feed Roll ................................................................................. 3-15
3.18 Input And Output Wire Guide Installation ..................................................... 3-15
3.19 Wire Reel Brake ............................................................................................ 3-16
3.20 Shielding Gas Regulator Operating Instructions ........................................... 3-17
SECTION 4: BASIC WELDING GUIDE .................................................................... 4-1
4.01 MIG (GMAW/FCAW) Basic Welding Technique ............................................... 4-1
4.02 MIG (GMAW/FCAW) Welding Troubleshooting ............................................... 4-4
SECTION 5: ROUTINE SERVICE REQUIREMENTS ...................................................... 5-1
5.01 Cleaning the Welding Power Source ............................................................... 5-1
5.02 Cleaning the Feed Rolls ................................................................................... 5-2
TABLE OF CONTENTS
SECTION 6: KEY SPARE PARTS .......................................................................... 6-1
6.01 2RT Wire Feeder replacement parts ................................................................ 6-1
APPENDIX 1: OPTIONS AND ACCESSORIES ............................................................ A-1
APPENDIX 2: 2RT WIRING SCHEMATIC ................................................................. A-2
CIGWELD LIMITED WARRANTY ........................................................................ RC-2
CIGWELD TERMS OF WARRANTY – APRIL 2012 .................................................... RC-3
WARRANTY SCHEDULE – APRIL 2010 ................................................................ RC-4
GLOBAL CUSTOMER SERVICE CONTACT INFORMATION ........................................... RC-5
TRANSMIG 2RT
Manual 0-5196 1-1 GENERAL INFORMATION
1.01 Arc Welding Hazards
WARNING
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal
shocks or severe burns. The electrode and
work circuit is electrically live whenever the
output is on. The input power circuit and ma-
chine internal circuits are also live when power
is on. In semiautomatic or automatic wire
welding, the wire, wire reel, drive roll housing,
and all metal parts touching the welding wire
are electrically live. Incorrectly installed or
improperly grounded equipment is a hazard.
1. Do not touch live electrical parts.
2. Wear dry, hole-free insulating gloves and body protec-
tion.
3. Insulate yourself from work and ground using dry
insulating mats or covers.
4. Disconnect input power or stop engine before install-
ing or servicing this equipment. Lock input power
disconnect switch open, or remove line fuses so power
cannot be turned on accidentally.
5. Properly install and ground this equipment according
to its Owner’s Manual and national, state, and local
codes.
6. Turn off all equipment when not in use. Disconnect
power to equipment if it will be left unattended or out
of service.
7. Use fully insulated electrode holders. Never dip holder
in water to cool it or lay it down on the ground or the
work surface. Do not touch holders connected to two
welding machines at the same time or touch other
people with the holder or electrode.
8. Do not use worn, damaged, undersized, or poorly
spliced cables.
9. Do not wrap cables around your body.
10. Ground the workpiece to a good electrical (earth)
ground.
11. Do not touch electrode while in contact with the work
(ground) circuit.
12. Use only well-maintained equipment. Repair or replace
damaged parts at once.
13. In confi ned spaces or damp locations, do not use a
welder with AC output unless it is equipped with a
voltage reducer. Use equipment with DC output.
14. Wear a safety harness to prevent falling if working
above fl oor level.
15. Keep all panels and covers securely in place.
SECTION 1: ARC WELDING SAFETY INSTRUCTIONS AND WARNINGS
!
WARNING
PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY.
PACEMAKER WEARERS KEEP AWAY UNTIL CONSULTING YOUR DOCTOR. DO NOT LOSE THESE INSTRUCTIONS.
READ OPERATING/INSTRUCTION MANUAL BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
Welding products and welding processes can cause serious injury or death, or damage to other equipment or property,
if the operator does not strictly observe all safety rules and take precautionary actions.
Safe practices have developed from past experience in the use of welding and cutting. These practices must be learned
through study and training before using this equipment. Some of these practices apply to equipment connected to
power lines; other practices apply to engine driven equipment. Anyone not having extensive training in welding and
cutting practices should not attempt to weld.
Safe practices are outlined in the Australian Standard AS1674.2-2007 entitled: Safety in welding and allied processes
Part 2: Electrical. This publication and other guides to what you should learn before operating this equipment are
listed at the end of these safety precautions. HAVE ALL INSTALLATION, OPERATION, MAINTENANCE, AND REPAIR
WORK PERFORMED ONLY BY QUALIFIED PEOPLE.
TRANSMIG 2RT
GENERAL INFORMATION 1-2 Manual 0-5196
WARNING
ARC RAYS can burn eyes and skin; NOISE can
damage hearing.
Arc rays from the welding process produce
intense heat and strong ultraviolet rays that
can burn eyes and skin. Noise from some
processes can damage hearing.
1. Use a Welding Helmet or Welding Faceshield fi tted
with a proper shade of fi lter (see ANSI Z49.1 and AS
1674 listed in Safety Standards) to protect your face
and eyes when welding or watching.
2. Wear approved safety glasses. Side shields recom-
mended.
3. Use protective screens or barriers to protect others
from fl ash and glare; warn others not to watch the arc.
4. Wear protective clothing made from durable, fl ame-
resistant material (wool and leather) and foot protec-
tion.
5. Use approved ear plugs or ear muffs if noise level is
high.
6. Never wear contact lenses while welding.
Recommended Protective Filters for Electric Welding
Description of Process
Approximate Range of
Welding Current in Amps
Minimum Shade Number of
Filter(s)
Manual Metal Arc Welding - covered
electrodes (MMAW)
Less than or equal to 100 8
100 to 200 10
200 to 300 11
300 to 400 12
Greater than 400 13
Gas Metal Arc Welding (GMAW)
(MIG) other than Aluminium and
Stainless Steel
Less than or equal to 150 10
150 to 250 11
250 to 300 12
300 to 400 13
Greater than 400 14
Gas Metal Arc Welding (GMAW)
(MIG) Aluminium and Stainless Steel
Less than or equal to 250 12
250 to 350 13
Gas Tungsten Arc Welding (GTAW)
(TIG)
Less than or equal to 100 10
100 to 200 11
200 to 250 12
250 to 350 13
Greater than 350 14
Flux-cored Arc Welding (FCAW) -with
or without shielding gas.
Less than or equal to 300 11
300 to 400 12
400 to 500 13
Greater than 500 14
Air - Arc Gouging Less than or equal to 400 12
Plasma - Arc Cutting
50 to 100 10
100 to 400 12
400 to 800 14
Plasma - Arc Spraying
15
Plasma - Arc Welding
Less than or equal to 20 8
20 to 100 10
100 to 400 12
400 to 800 14
Submerged - Arc Welding
2(5)
Resistance Welding
Safety Spectacles or eye shield
Refer to standard AS/NZS 1338.1:1992 for comprehensive information regarding the above table.
TRANSMIG 2RT
Manual 0-5196 1-3 GENERAL INFORMATION
WARNING
FUMES AND GASES can be hazardous to your
health.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to
your health.
1. Keep your head out of the fumes. Do not breath the
fumes.
2. If inside, ventilate the area and/or use exhaust at the
arc to remove welding fumes and gases.
3. If ventilation is poor, use an approved air-supplied
respirator.
4. Read the Material Safety Data Sheets (MSDSs) and the
manufacturer’s instruction for metals, consumables,
coatings, and cleaners.
5. Work in a confi ned space only if it is well ventilated,
or while wearing an air-supplied respirator. Shielding
gases used for welding can displace air causing injury
or death. Be sure the breathing air is safe.
6. Do not weld in locations near degreasing, cleaning, or
spraying operations. The heat and rays of the arc can
react with vapours to form highly toxic and irritating
gases.
7. Do not weld on coated metals, such as galvanized,
lead, or cadmium plated steel, unless the coating is
removed from the weld area, the area is well ventilated,
and if necessary, while wearing an air-supplied respi-
rator. The coatings and any metals containing these
elements can give off toxic fumes if welded.
WARNING
WELDING can cause fi re or explosion.
Sparks and spatter fl y off from the welding arc.
The fl ying sparks and hot metal, weld spatter,
hot workpiece, and hot equipment can cause
res and burns. Accidental contact of electrode
or welding wire to metal objects can cause
sparks, overheating, or fi re.
1. Protect yourself and others from fl ying sparks and hot
metal.
2. Do not weld where fl ying sparks can strike fl ammable
material.
3. Remove all fl ammables within 10M of the welding arc.
If this is not possible, tightly cover them with approved
covers.
4. Be alert that welding sparks and hot materials from
welding can easily go through small cracks and open-
ings to adjacent areas.
5. Watch for fi re, and keep a fi re extinguisher nearby.
6. Be aware that welding on a ceiling, fl oor, bulkhead, or
partition can cause fi re on the hidden side.
7. Do not weld on closed containers such as tanks or
drums.
8. Connect work cable to the work as close to the weld-
ing area as practical to prevent welding current from
travelling long, possibly unknown paths and causing
electric shock and fi re hazards.
9. Do not use welder to thaw frozen pipes.
10. Remove stick electrode from holder or cut off welding
wire at contact tip when not in use.
WARNING
FLYING SPARKS AND HOT METAL can cause
injury.
Chipping and grinding cause fl ying metal. As
welds cool, they can throw off slag.
1. Wear approved face shield or safety goggles. Side
shields recommended.
2. Wear proper body protection to protect skin.
WARNING
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under
high pressure. If damaged, a cylinder can
explode. Since gas cylinders are normally
part of the welding process, be sure to treat
them carefully.
1. Protect compressed gas cylinders from excessive
heat, mechanical shocks, and arcs.
2. Install and secure cylinders in an upright position by
chaining them to a stationary support or equipment
cylinder rack to prevent falling or tipping.
TRANSMIG 2RT
GENERAL INFORMATION 1-4 Manual 0-5196
3. Keep cylinders away from any welding or other electri-
cal circuits.
4. Never allow a welding electrode to touch any cylinder.
5. Use only correct shielding gas cylinders, regulators,
hoses, and fi ttings designed for the specifi c application;
maintain them and associated parts in good condition.
6. Turn face away from valve outlet when opening
cylinder valve.
7. Keep protective cap in place over valve except when
cylinder is in use or connected for use.
8. Read and follow instructions on compressed gas
cylinders, associated equipment, and CGA publication
P-1 listed in Safety Standards.
WARNING
MOVING PARTS can cause injury.
Moving parts, such as fans, rotors, and belts can cut
ngers and hands and catch loose clothing.
1. Keep all doors, panels, covers, and guards closed and
securely in place.
2. Stop engine before installing or connecting unit.
3. Have only qualifi ed people remove guards or covers
for maintenance and troubleshooting as necessary.
4. To prevent accidental starting during servicing, discon-
nect negative (-) battery cable from battery.
5. Keep hands, hair, loose clothing, and tools away from
moving parts.
6. Reinstall panels or guards and close doors when
servicing is fi nished and before starting engine.
!
WARNING
This product, when used for welding or cut-
ting, produces fumes or gases which contain
chemicals know to the State of California to
cause birth defects and, in some cases, cancer.
(California Health & Safety code Sec. 25249.5
et seq.)
NOTE
Considerations About Welding And The Effects
of Low Frequency Electric and Magnetic Fields
The following is a quotation from the General Con-
clusions Section of the U.S. Congress, Office of
Technology Assessment, Biological Effects of Power
Frequency Electric & Magnetic Fields - Background Paper,
OTA-BP-E-63 (Washington, DC: U.S. Government Printing
Offi ce, May 1989): “...there is now a very large volume
of scientifi c fi ndings based on experiments at the cellular
level and from studies with animals and people which
clearly establish that low frequency magnetic fi elds and
interact with, and produce changes in, biological systems.
While most of this work is of very high quality, the results
are complex. Current scientifi c understanding does not
yet allow us to interpret the evidence in a single coherent
framework. Even more frustrating, it does not yet allow us
to draw defi nite conclusions about questions of possible
risk or to offer clear science-based advice on strategies
to minimize or avoid potential risks.”
To reduce magnetic fi elds in the workplace, use the fol-
lowing procedures.
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cable around the body.
4. Keep welding power source and cables as far away
from body as practical.
ABOUT PACEMAKERS:
The above procedures are among those
also normally recommended for pacemaker
wearers. Consult your doctor for complete
information.
TRANSMIG 2RT
Manual 0-5196 1-5 GENERAL INFORMATION
1.02 Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American Welding Society, 550 N.W. LeJeune Rd., Miami,
FL 33126.
Safety and Health Standards, OSHA 29 CFR 1910, from Superintendent of Documents, U.S. Government Printing
Offi ce, Washington, D.C. 20402.
Recommended Safe Practices for the Preparation for Welding and Cutting of Containers That Have Held Hazardous
Substances, American Welding Society Standard AWS F4.1, from American Welding Society, 550 N.W. LeJeune Rd.,
Miami, FL 33126.
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Batterymarch Park, Quincy,
MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1235 Jef-
ferson Davis Highway, Suite 501, Arlington, VA 22202.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards
Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices for Occupation and Educational Eye and Face Protection, ANSI Standard Z87.1, from American National
Standards Institute, 1430 Broadway, New York, NY 10018.
Cutting and Welding Processes, NFPA Standard 51B, from National Fire Protection Association, Batterymarch Park,
Quincy, MA 02269.
Safety in welding and allied processes Part 1: Fire Precautions, AS 1674.1-1997 from SAI Global Limited, www.
saiglobal.com.
Safety in welding and allied processes Part 2: Electrical, AS 1674.2-2007 from SAI Global Limited, www.saiglobal.com.
Filters for eye protectors - Filters for protection against radiation generated in welding and allied operations AS/NZS
1338.1:1992 from SAI Global Limited, www.saiglobal.com.
TRANSMIG 2RT
GENERAL INFORMATION 1-6 Manual 0-5196
1.03 Declaration of Conformity
Manufacturer: CIGWELD
Address: 71 Gower St, Preston
Victoria 3072
Australia
Description of equipment: Welding Equipment (GMAW, FCAW, ) including, but not limited to CIGWELD Transmig 2RT
wire feeder and associated accessories.
Serial numbers are unique with each individual piece of equipment and details description, parts used to manufacture
a unit and date of manufacture.
The equipment conforms to all applicable aspects and regulations of the ‘Low Voltage Directive’ (Directive 73/23/EU,
as recently changed in Directive 93/68/EU and to the National legislation for the enforcement of the Directive.
National Standard and Technical Specifi cations
The product is designed and manufactured to a number of standards and technical requirements among them are:
IEC 60974-10 applicable to Industrial Equipment - generic emissions and regulations.
AS 1674 Safety in welding and allied processes.
IEC 60974-5 Arc welding equipment, Wirefeeders.
Extensive product design verifi cation is conducted at the manufacturing facility as part of the routine design and
manufacturing process, to ensure the product is safe and performs as specifi ed. Rigorous testing is incorporated into
the manufacturing process to ensure the manufactured product meets or exceeds all design specifi cations.
CIGWELD has been manufacturing and merchandising an extensive equipment range with superior performance, ultra
safe operation and world class quality for more than 30 years and will continue to achieve excellence.
INTRODUCTION TRANSMIG 2RT
Manual 0-5196 2-1 INTRODUCTION
SECTION 2: INTRODUCTION
2.02 Equipment Identifi cation
The unit’s identifi cation number (specifi cation or part
number), model, and serial number usually appear on
a nameplate attached to the machine. Equipment which
does not have a nameplate attached to the machine is
identifi ed only by the specifi cation or part number printed
on the shipping container. Record these numbers for
future reference.
2.03 Receipt of Equipment
When you receive the equipment, check it against the
invoice to make sure it is complete and inspect the equip-
ment for possible damage due to shipping. If there is any
damage, notify the carrier immediately to fi le a claim.
Furnish complete information concerning damage claims
or shipping errors to the location in your area listed in the
inside back cover of this manual.
Include all equipment identifi cation numbers as described
above along with a full description of the parts in error.
Move the equipment to the installation site before un-
crating the unit. Use care to avoid damaging the equip-
ment when using bars, hammers, etc., to un-crate the unit.
2.01 How to Use This Manual
This Operating Manual usually applies to the part numbers
listed on page i. To ensure safe operation, read the entire
manual, including the chapter on safety instructions and
warnings. Throughout this manual, the word WARNING,
CAUTION and NOTE may appear. Pay particular attention
to the information provided under these headings. These
special annotations are easily recognized as follows:
!
WARNING
Gives information regarding possible personal
injury. Warnings will be enclosed in a box
such as this.
CAUTION
Refers to possible equipment damage. Cau-
tions will be shown in bold type.
NOTE
Offers helpful information concerning certain
operating procedures. Notes will be shown
in italics
Additional copies of this manual may be purchased by
contacting Cigweld at the address and phone number
for your location listed in the inside back cover of this
manual. Include the Owner’s Manual number and equip-
ment identifi cation numbers.
TRANSMIG 2RT INTRODUCTION
INTRODUCTION 2-2 Manual 0-5196
2.04 Symbol Chart
Note that only some of these symbols will appear on your model.
Gas Tungsten Arc
Welding (GTAW)
Air Carbon Arc
Cutting (CAC-A)
Constant Current
Constant Voltage
Or Constant Potential
High Temperature
Fault Indication
Arc Force
Touch Start (GTAW)
Variable Inductance
Voltage Input
Single Phase
Three Phase
Three Phase Static
Frequency Converter-
Transformer-Rectifier
Dangerous Voltage
Off
On
Panel/Local
Manual Metal
Arc Welding (MMAW)
Gas Metal Arc
Welding (GMAW)
Increase/Decrease
Circuit Breaker
AC Auxiliary Power
Remote
Duty Cycle
Percentage
Amperage
Voltage
Hertz (cycles/sec)
Frequency
Negative
Positive
Direct Current (DC)
Protective Earth
(Ground)
Line
Line Connection
Auxiliary Power
Receptacle Rating-
Auxiliary Power
Art # A-10344
115V 15A
t
t1
t2
%
X
IPM
MPM
t
V
Fuse
Wire Feed Function
Wire Feed Towards
Workpiece With
Output Voltage Off.
Preflow Time
Postflow Time
Spot Time
Spot Weld Mode
Continuous Weld
Mode
Press to initiate wirefeed and
welding, release to stop.
Purging Of Gas
Inches Per Minute
Meters Per Minute
Disturbance In
Ground System
Welding Torch
Burnback Time
Press and hold for preflow, release
to start arc. Press to stop arc, and
hold for preflow.
4 Step Trigger
Operation
2 Step Trigger
Operation
Figure 2-1 Symbol chart
INTRODUCTION TRANSMIG 2RT
Manual 0-5196 2-3 INTRODUCTION
2.05 Description
The Transmig 2RT Wirefeeder is fully compliant to Stand-
ard IEC 60974.5.The Transmig 2RT Wirefeeder when used
in conjunction with the Transmig 250i Multi Process Weld-
er provides excellent MIG welding performance across a
broad range of applications when used with the correct
welding consumables and procedures. The instructions
in the next section detail how to correctly and safely set
up the machine and give guidelines on gaining the best
effi ciency and quality from the Power Source. Please read
these instructions thoroughly before using the unit.
2.06 User Responsibility
This equipment will perform as per the information con-
tained herein when installed, operated, maintained and
repaired in accordance with the instructions provided.
This equipment must be checked periodically. Defective
equipment (including welding leads) should not be used.
Parts that are broken, missing, plainly worn, distorted or
contaminated, should be replaced immediately. Should
such repairs or replacements become necessary, it is
recommended that such repairs be carried out by appro-
priately qualifi ed persons approved by CIGWELD. Advice
in this regard can be obtained by contacting an Accredited
CIGWELD Distributor.
This equipment or any of its parts should not be altered
from standard specifi cation without prior written approval
of CIGWELD. The user of this equipment shall have the
sole responsibility for any malfunction which results from
improper use or unauthorized modifi cation from standard
specifi cation, faulty maintenance, damage or improper re-
pair by anyone other than appropriately qualifi ed persons
approved by CIGWELD.
2.07 Transportation Methods
!
WARNING
ELECTRIC SHOCK can kill. DO NOT TOUCH
live electrical parts. Disconnect input power
conductors from de-energized supply line
before moving the welding power source.
!
WARNING
FALLING EQUIPMENT can cause serious per-
sonal injury and equipment damage.
Lift unit with integrated handle at the top of the unit.
Use handcart or similar device of adequate capacity.
If using a fork lift vehicle, place and secure unit on a proper
skid before transporting.
2.08 Packaged Items
Transmig 2RT Wirefeeder
(Part No. W3000500)
• Transmig 2RT Wirefeeder
• 8M Interconnection Lead, Fitted
• Operating Manual
• Drive Roll 0.9-1.2mm, Fitted
• Pressure Roll 0.6-1.2mm Solid Wire, Fitted
• Outlet Guide 0.9-1.2mm, Fitted
TRANSMIG 2RT INTRODUCTION
INTRODUCTION 2-4 Manual 0-5196
2.09 Specifi cations
Description Transmig 2RT Wirefeeder
Wirefeeder Plant Part Number W3000500
Wirefeeder Plant Dimensions H 453mm x W 238mm x D 553mm
Wirefeeder Plant Mass 25kg
Wire Feed Motor Voltage 24 VDC
Gas Solenoid Voltage 24 VDC
MIG (GMAW) Welding Output,
40°C, 10 min
30% @ 350A
60% @ 250A
100% @ 205A
Minimum Wire Speed 1.2 MPM
Maximum Wire Speed 17.8 MPM
Operating Temperature Range 0°C - 40°C
Interconnection Plug 10 Pin
Interconnection Length 8 metre
Table 2-1: Transmig 2RT Specifi cation
NOTE
Due to variations that can occur in manufactured products, claimed performance, voltages, ratings, all
capacities, measurements, dimensions and weights quoted are approximate only. Achievable capacities and
ratings in use and operation will depend upon correct installation, use, applications, maintenance and service.
INSTALLATION/SETUP TRANSMIG 2RT
Manual 0-5196 3-1 INSTALLATION/SETUP
3.01 Environment
These units are designed for use in environments with
increased hazard of electric shock as outlined in IEC
60974.5.
A. Examples of environments with increased hazard of
electric shock are:
1. In locations in which freedom of movement is re-
stricted, so that the operator is forced to perform the
work in a cramped (kneeling, sitting or lying) position
with physical contact with conductive parts.
2. In locations which are fully or partially limited by con-
ductive elements, and in which there is a high risk of
unavoidable or accidental contact by the operator.
3. In wet or damp hot locations where humidity or per-
spiration considerably reduces the skin resistance
of the human body and the insulation properties of
accessories.
B. Environments with increased hazard of electric shock
do not include places where electrically conductive parts in
the near vicinity of the operator, which can cause increased
hazard, have been insulated.
3.02 Location
Be sure to locate the welder according to the following
guidelines:
A. In areas, free from moisture and dust.
B. Ambient temperature between 0° C to 40° C.
C. In areas, free from oil, steam and corrosive gases.
D. In areas, not subjected to abnormal vibration or shock.
E. In areas, not exposed to direct sunlight or rain.
F. The enclosure design of this Wire Feeder meets the
requirements of IP23S as outlined in AS60529. This
provides adequate protection against solid objects
(greater than 12mm), and direct protection from verti-
cal drops. Under no circumstances should the unit be
operated or connected in a micro environment that will
exceed the stated conditions. For further information
please refer to AS 60529.
G. Precautions must be taken against the Wire Feeder
toppling over. The Wire Feeder must be located on
a suitable horizontal surface in the upright position
when in use.
SECTION 3: INSTALLATION OPERATION AND SETUP
WARNING
This equipment should be electrically
connected by a qualifi ed electrician.
3.03 Ventilation
!
WARNING
Since the inhalation of welding fumes can
be harmful, ensure that the welding area is
effectively ventilated.
3.04 Mains Supply Voltage
Requirements
See Operating Manual for Transmig 250i.
3.05 Electromagnetic Compatibility
!
WARNING
Extra precautions for Electromagnetic
Compatibility may be required when this
Welding Power Source is used in a domestic
situation.
A. Installation and Use - Users Responsibility
The user is responsible for installing and using the welding
equipment according to the manufacturer’s instructions.
If electromagnetic disturbances are detected then it shall
be the responsibility of the user of the welding equipment
to resolve the situation with the technical assistance of
the manufacturer. In some cases this remedial action
may be as simple as earthing the welding circuit, see
NOTE below. In other cases it could involve constructing
an electromagnetic screen enclosing the Welding Power
Source and the work, complete with associated input
lters. In all cases, electromagnetic disturbances shall be
reduced to the point where they are no longer Trouble-
some.
TRANSMIG 2RT INSTALLATION/SETUP
INSTALLATION/SETUP 3-2 Manual 0-5196
NOTE
The welding circuit may or may nor be earthed
for safety reasons. Changing the earthing ar-
rangements should only be authorised by a
person who is competent to assess whether
the changes will increase the risk of injury,
e.g. by allowing parallel welding current return
paths which may damage the earth circuits of
other equipment. Further guidance is given in
IEC 60974-13 Arc Welding Equipment - Instal-
lation and use (under preparation).
B. Assessment of Area
Before installing welding equipment, the user shall make
an assessment of potential electromagnetic problems in
the surrounding area. The following shall be taken into
account.
1. Other supply cables, control cables, signalling and
telephone cables; above, below and adjacent to the
welding equipment.
2. Radio and television transmitters and receivers.
3. Computer and other control equipment.
4. Safety critical equipment, e.g. guarding of industrial
equipment.
5. The health of people around, e.g. the use of pace-
makers and hearing aids.
6. Equipment used for calibration and measurement.
7. The time of day that welding or other activities are to
be carried out.
8. The immunity of other equipment in the environment:
the user shall ensure that other equipment being used
in the environment is compatible: this may require
additional protection measures.
The size of the surrounding area to be considered will
depend on the structure of the building and other activities
that are taking place. The surrounding area may extend
beyond the boundaries of the premises.
C. Methods of Reducing Electromagnetic Emissions
1. Mains Supply
Welding equipment should be connected to the
mains supply according to the manufacturer’s
recommendations. If interference occurs, it may be
necessary to take additional precautions such as
ltering of the mains supply. Consideration should
be given to shielding the supply cable of permanently
installed welding equipment in metallic conduit or
equivalent. Shielding should be electrically continuous
throughout its length. The shielding should be
connected to the Welding Power Source so that good
electrical contact is maintained between the conduit
and the Welding Power Source enclosure.
2. Maintenance of Welding Equipment
The welding equipment should be routinely maintained
according to the manufacturer’s recommendations. All
access and service doors and covers should be closed
and properly fastened when the welding equipment
is in operation. The welding equipment should not
be modifi ed in any way except for those changes
and adjustments covered in the manufacturer’s
instructions.
3. Welding Cables
The welding cables should be kept as short as possible
and should be positioned close together but never
coiled and running at or close to the fl oor level.
4. Equipotential Bonding
Bonding of all metallic components in the welding
installation and adjacent to it should be considered.
However, metallic components bonded to the work
piece will increase the risk that the operator could
receive a shock by touching the metallic components
and the electrode at the same time. The operator
should be insulated from all such bonded metallic
components.
5. Earthing/grounding of the Work Piece
Where the work piece is not bonded to earth for electri-
cal safety, nor connected to earth because of its size
and position, e.g. ship’s hull or building steelwork,
a connection bonding the work piece to earth may
reduce emissions in some, but not all instances. Care
should be taken to prevent the earthing of the work
piece increasing the risk of injury to users, or damage
to other electrical equipment. Where necessary, the
connection of the work piece to earth should be made
by direct connection to the work piece, but in some
countries where direct connection is not permitted, the
bonding should be achieved by suitable capacitance,
selected according to national regulations.
6. Screening and Shielding
Selective screening and shielding of other cables
and equipment in the surrounding area may alleviate
problems of interference. Screening the entire welding
installation may be considered for special applications.
INSTALLATION/SETUP TRANSMIG 2RT
Manual 0-5196 3-3 INSTALLATION/SETUP
3.06 2RT Wire Feeder Controls,
Indicators and Features
The 2RT Wirefeeder is designed to be used with the
Transmig 250i. Select MIG Process and REMT in the
Advanced Features menu on the Transmig 250i to enable
the controls on the 2RT wirefeeder. See the 250i Operat-
ing manual for details.
Vol ts
Wirespeed
Left Knob
Right Knob
1
2
3
4
Art # A-10404
Figure 3-1: 2RT Front Panel Controls
Art # A-10470_AB
5
REMOTE
LOCAL
Figure 3-2: 2RT Local/Remote Switch
The Tweco professional MIG Torch will connect to the 2RT
just as it does to the 250i power source. The electrode
Polarity setting is done at the power source. See sub
sections 3.09 and 3.10.
1. Left Knob: WFS (Wire Feed Speed) Control
Amperage Control
Wirespeed
Left Knob
The Left Knob controls the Wirespeed in the wirefeeder.
It adjusts the preview wire speed display in the power
source. The amperage control knob adjusts the amount
of welding current delivered by the power source. In MIG
mode, the amperage knob adjusts the speed of the wire
feed motor (which in turn adjusts the output current by
varying the amount of MIG wire delivered to the welding
arc). The optimum wire speed required is dependent on
the type of welding application. The setup chart on the
inside of the wire feed compartment door of the Transmig
250i provides a brief summary of the required output set-
tings for a basic range of MIG welding applications. The
value may also be adjusted while a weld is in progress – if
this occurs, the left display will briefl y switch to show the
adjusted value as the knob on the 2RT is turned, and will
automatically revert back to showing the set weld current
measurements when the knob is not being turned.
2. Right Knob: MIG Voltage Control
Right Knob
MIG Voltage Control
In this mode the control knob is used to adjust the output
voltage of the power source. It adjusts the preview volt-
age display in the power source. The welding voltage is
increased by turning the knob on the 2RT clockwise or
decreased by turning the knob anti-clockwise. The opti-
mum voltage level required is dependent on the type of
welding application. The setup chart on the inside of the
wire feed compartment door of the power supply provides
a brief summary of the required output settings for a basic
range of MIG welding applications. The value may also
be adjusted while a weld is in progress – if this occurs,
the left display on the power supply will briefl y switch to
show the adjusted value as the knob on the 2RT is turned,
and will automatically revert back to showing the set weld
current measurements when the knob is not being turned.
TRANSMIG 2RT INSTALLATION/SETUP
INSTALLATION/SETUP 3-4 Manual 0-5196
3. MIG Torch Adaptor (Euro Style)
The MIG Torch adaptor is the connection point for the MIG welding Torch. Connect the MIG Torch by pushing the
MIG Torch connector into the brass MIG Torch adaptor fi rmly and screwing the plastic MIG Torch nut clockwise
to secure in position. To remove the MIG Torch simply reverse these directions.
4. Remote Control Socket
The 8 pin Remote Control Socket is used to connect remote control devices to the 2RT Wirefeeder. To make con-
nections, align keyway, insert plug, and rotate threaded collar fully clockwise.
2
1
8
7
6
3
4
5
Trigger Switch
Remote Wirespeed in GMAW mode
Remote Volts in
GMAW Mode
1
2
3
4
5
6
7
8
W
V
A-10477
Figure 3-3: Remote Control Socket
Socket Pin
Function
1 Not connected
2
Trigger Switch Input
3
Trigger Switch Input
4
Not connected
5
5k ohm (maximum) connection to 5k ohm remote control potentiometer.
6
Zero ohm (minimum) connection to 5k ohm remote control potentiometer.
7
Wiper arm connection to 5k ohm remote control Wirespeed MIG mode potentiometer.
8
Wiper arm connection to 5k ohm remote control Volts MIG mode potentiometer.
Table 3-1
5. Local/Remote Switch (Located in wire feed compartment)
The remote / local switch(inside the 2RT) is used to switch between using the controls on the wire feeder and
using controls on a remote device attached to the wirefeeder (such as a MIG Gun with remote voltage and wire
feed speed control). To use the controls on the wirefeeder the switch must be in the Local position. When the lo-
cal/remote switch is in the local position, the 2 RT wirefeeder controls will take over and all voltage and wire feed
speed will be made from there. To use a remote control device (such as a MIG Gun with remote voltage and wire
feed speed control) the switch must be in the Remote position. Note that the MIG Gun trigger will operate at all
times regardless of the position of the local remote switch (i.e. in both local and remote modes).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54

ESAB 2RT Transmig Wire Feeder User manual

Category
Welding System
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI