FortiGate-5060
Chassis Guide
A detailed guide to the FortiGate-5060 chassis. This FortiGate-5060 Chassis Guide describes FortiGate-5060 hardware
features, and how to install the FortiGate-5060 chassis.
The most recent versions of this and all FortiGate-5000 series documents are available from the FortiGate-5000 page of
the Fortinet Technical Documentation web site (http://docs.fortinet.com).
Visit http://support.fortinet.com to register your FortiGate-5060 chassis. By registering you can receive product updates,
technical support, and FortiGuard services.
FortiGate-5060 Chassis Guide
01-400-129494-20110912
Warnings and cautions
FortiGate-5060
01-400-129494-20110912 2
http://docs.fortinet.com/Feedback
Warnings and cautions
Only trained and qualified personnel should be allowed to install or maintain
FortiGate-5000 series equipment. Read and comply with all warnings, cautions and
notices in this document.
Turning off all power switches may not turn off all power to the FortiGate-5000 series
equipment. Some circuitry in the FortiGate-5000 series equipment may continue to
operate even though all power switches are off.
FortiGate-5000 equipment must be protected by a readily accessible disconnect
device or circuit breaker that can be used for product power down emergencies.
Many FortiGate-5000 components are hot swappable and can be installed or removed
while the power is on. But some of the procedures in this document may require power
to be turned off and completely disconnected. Follow all instructions in the procedures
in this document that describe disconnecting FortiGate-5000 series equipment from
power sources, telecommunications links and networks before installing, or removing
FortiGate-5000 series components, or performing other maintenance tasks. Failure to
follow the instructions in this document can result in personal injury or equipment
damage.
Install FortiGate-5000 series chassis at the lower positions of a rack to avoid making
the rack top-heavy and unstable.
Do not insert metal objects or tools into open chassis slots.
Electrostatic discharge (ESD) can damage FortiGate-5000 series equipment. Only
perform the procedures described in this document from an ESD workstation. If no
such station is available, you can provide some ESD protection by wearing an
anti-static wrist strap and attaching it to an available ESD connector such as the ESD
sockets provided on FortiGate-5000 series chassis.
Make sure all FortiGate-5000 series components have reliable grounding. Fortinet
recommends direct connections to the building ground.
If you install a FortiGate-5000 series component in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater
than room ambient. Make sure the operating ambient temperature does not exceed
Fortinet’s maximum rated ambient temperature.
Installing FortiGate-5000 series equipment in a rack should be such that the amount of
airflow required for safe operation of the equipment is not compromised.
FortiGate-5000 series chassis should be installed by a qualified electrician.
FortiGate-5000 series equipment shall be installed and connected to an electrical
supply source in accordance with the applicable codes and regulations for the location
in which it is installed. Particular attention shall be paid to use of correct wire type and
size to comply with the applicable codes and regulations for the installation / location.
Connection of the supply wiring to the terminal block on the equipment may be
accomplished using Listed wire compression lugs, for example, Pressure Terminal
Connector made by Ideal Industries Inc. or equivalent which is suitable for AWG-10.
Particular attention shall be given to use of the appropriate compression tool specified
by the compression lug manufacturer, if one is specified.
This product is only intended for use in a Restricted Access Location.
CAUTION: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used
Batteries According to the Instructions.
Caution: You should be aware of the following cautions and warnings before installing
FortiGate-5000 series hardware
FortiGate-5060 Chassis Guide
01-400-129494-20110912 3
http://docs.fortinet.com/Feedback
Contents
Warnings and cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FortiGate-5060 chassis 7
FortiGate-5060 front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
FortiGate-5060 chassis back panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Physical description of the FortiGate-5060 chassis . . . . . . . . . . . . . . . . . . 10
FortiGate-5060 shelf managers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Using the shelf manager CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Shelf Manager fan and power control . . . . . . . . . . . . . . . . . . . . . . . 12
FortiGate-5060 shelf alarm panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Shelf alarm panel telco alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Air filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Cooling fan trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Power connection and configuration 17
About data center DC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Connecting the FortiGate-5060 chassis to DC power and data center ground. . . . . 17
Connecting a FortiGate-5060 PEM to DC power . . . . . . . . . . . . . . . . . . . . 18
Connecting the FortiGate-5060 chassis to data center ground. . . . . . . . . . . . . 19
Connecting the FortiGate-5060 chassis to AC power using a FortiGate
power converter shelf. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Turning on FortiGate-5060 chassis power . . . . . . . . . . . . . . . . . . . . . . . 20
FortiGate-5060 hardware procedures 23
Mounting the FortiGate-5060 chassis . . . . . . . . . . . . . . . . . . . . . . . . . 23
Air flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Inserting 5000 series boards and RTM modules into a FortiGate-5060 chassis . . . . 23
Using FortiSwitch-5003A boards for backplane communication . . . . . . . . . . . . 24
Contents
FortiGate-5060 Chassis Guide
401-400-129494-20110912
http://docs.fortinet.com/Feedback
Using the shelf manager CLI 27
Connecting to the shelf manager CLI using a serial port . . . . . . . . . . . . . . . . 27
Connecting to the shelf manager CLI . . . . . . . . . . . . . . . . . . . . . . . 28
Changing the shelf manager root account password . . . . . . . . . . . . . . . 28
The shelf manager command line interface agent (CLIA) . . . . . . . . . . . . . 29
Using CLIA interactive mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
IPMB addresses, logical and physical slot numbers, and FRU ids . . . . . . . . . . . 30
Basic shelf manager CLI Commands. . . . . . . . . . . . . . . . . . . . . . . . . . 31
Change IP address of the primary Shelf Manager . . . . . . . . . . . . . . . . . 31
Display the shelf manager firmware version . . . . . . . . . . . . . . . . . . . . 31
List all FRUs in the chassis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
List all sensors on a FRU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
List only sensors that are outside of established thresholds . . . . . . . . . . . . 31
Display sensor data for a FRU . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Display the FRU information for a FRU . . . . . . . . . . . . . . . . . . . . . . 31
Change the speed for a fan tray . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Display the contents of the system event log (sel) . . . . . . . . . . . . . . . . . 31
Clear the system event log (sel) . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Changing the shelf manager IP address and default gateway . . . . . . . . . . . . . 32
Sensor types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
activate/deactivate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Clearing alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Setting alarm output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Viewing information about a board . . . . . . . . . . . . . . . . . . . . . . . . . 35
clia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
exit/quit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
fru . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Display information for all FRUs . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Display information for a specific FRU . . . . . . . . . . . . . . . . . . . . . . . 38
fruinfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
getlanconfig. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Displaying all configuration parameters for a channel . . . . . . . . . . . . . . . 40
Displaying specific parameters for a channel . . . . . . . . . . . . . . . . . . . 41
getthreshold/threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Display threshold sensor values for a physical slot . . . . . . . . . . . . . . . . 42
Display threshold sensor values for a specific sensor . . . . . . . . . . . . . . . 45
Contents
FortiGate-5060 Chassis Guide
01-400-129494-20110912 5
http://docs.fortinet.com/Feedback
help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Displaying more information about a command . . . . . . . . . . . . . . . . . . 48
minfanlevel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
sel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
sensordata . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
setthreshold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
shmstatus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
showunhealthy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
switchover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
terminate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
user . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Display all user accounts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Adding a user account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Deleting user accounts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Disabling and enabling user accounts . . . . . . . . . . . . . . . . . . . . . . . 57
Changing a user account user name. . . . . . . . . . . . . . . . . . . . . . . . 57
Changing a user account password . . . . . . . . . . . . . . . . . . . . . . . . 58
version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Generating SNMP traps for system events. . . . . . . . . . . . . . . . . . . . . . . 58
SNMP trap details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Removing and inserting a fan tray . . . . . . . . . . . . . . . . . . . . . . . . . 64
Using the chassis system event log (SEL) . . . . . . . . . . . . . . . . . . . . . . . 64
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Chassis Design Background . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Alarm LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Reading the System Event Log (SEL) . . . . . . . . . . . . . . . . . . . . . . . 66
Clearing SEL logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Example IPMC log output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Example FRU log output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Example sensor log output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Sample sections of SEL Output . . . . . . . . . . . . . . . . . . . . . . . . . . 77
For more information 79
Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Fortinet Tools and Documentation CD . . . . . . . . . . . . . . . . . . . . . . . 79
Fortinet Knowledge Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Comments on Fortinet technical documentation . . . . . . . . . . . . . . . . . 79
Customer service and technical support . . . . . . . . . . . . . . . . . . . . . . . . 79
Contents
FortiGate-5060 Chassis Guide
601-400-129494-20110912
http://docs.fortinet.com/Feedback
FortiGate-5060 Chassis Guide
01-400-129494-20110912 7
http://docs.fortinet.com/Feedback
FortiGate-5060 chassis
You can install up to six FortiGate-5000 series boards in the six slots of the FortiGate-5060
ATCA chassis. The FortiGate-5060 is a 5U 19-inch rackmount ATCA chassis that contains
two redundant hot swappable DC power entry Modules (PEMs) connect to -48 VDC Data
Center DC power. The FortiGate-5060 chassis also includes two hot swappable cooling
fan trays and a front replaceable air filter. If all six slots contain FortiGate-5001B boards,
the FortiGate-5060 chassis provides a total of 48 FortiGate 10-gigabit ethernet interfaces.
You can also install FortiSwitch-5003B boards in FortiGate-5060 chassis slots 1 and 2 to
provide base backplane communications using the dual star base backplane interface.
Base backplane communications can be used for HA heartbeat communications and for
data communications.
FortiSwitch-5003B boards can also provide fabric backplane communication using the
FortiGate-5060 fabric backplane channels. The fabric backplane is a triple replicated
3-channel full mesh 10-gigabit switch fabric.
For both base and fabric backplane communications you can install a single
FortiSwitch-5003B board in slot 1. You can add a second FortiSwitch-5003B board to
slot 2 for redundancy.
Some of the boards installed in a FortiGate-5060 chassis can be operating in a FortiGate
HA cluster and some can be operating as standalone FortiGate units. You can also
operate multiple HA clusters and standalone FortiGate units in a single FortiGate-5060
chassis. You can also use FortiSwitch-5003B boards to operate HA clusters consisting of
FortiGate-5000 series boards installed in multiple FortiGate-5000 chassis. You can also
use FortiSwitch-5003B boards for data communication between chassis and for Enhanced
Load Balancing Cluster (ELBC) configurations. You can also install FortiSwitch-5203B
boards in slots 1 and 2, add FortiGate-5001B boards to slots 3 and up and operate the
FortiGate-5060 chassis in HA over chassis mode.
The FortiGate-5060 chassis also includes six rear transition module (RTM) slots. The
FortiGate-5060 chassis supports 10-gigabit fabric channel communication if you have
installed FortiGate-5001A boards with FortiGate-RTM-XB2 or FortiGate-RTM-XD2
modules and one or two FortiSwitch-5003A or FortiSwitch-5003B boards.
The FortiGate-5060 chassis requires -48VDC Data Center DC power. If DC power is not
available you can install a FortiGate power converter shelf and power supplies (purchased
separately).
This chapter describes the FortiGate-5060 chassis and includes the following sections:
FortiGate-5060 front panel
FortiGate-5060 chassis back panel
Physical description of the FortiGate-5060 chassis
FortiGate-5060 shelf managers
FortiGate-5060 shelf alarm panel
Air filter
Cooling fan trays
FortiGate-5060 front panel FortiGate-5060 chassis
FortiGate-5060 Chassis Guide
801-400-129494-20110912
http://docs.fortinet.com/Feedback
FortiGate-5060 front panel
Figure 1 shows the front of a FortiGate-5060 chassis. Two FortiSwitch-5003B boards are
installed in slots 1 and 2. Four FortiGate-5001B boards are installed in slots 3, 4, 5, and 6.
The FortiGate-5060 primary Shelf Manager and the Shelf Alarm Panel (SAP) are also
visible. The factory installed shelf alarm panel displays alarms, provides a telco alarm
interface, and also provides serial connections to the shelf managers. The factory installed
primary shelf manager provides power allocation, cooling, alarms, and shelf status for the
FortiGate-5060 chassis. You can also install a secondary shelf manager as a backup for
the primary shelf manager. For more information about these components, see
“FortiGate-5060 shelf alarm panel” on page 12 and “FortiGate-5060 shelf managers” on
page 10.
Figure 1: FortiGate-5060 front panel with FortiGate-5001B and FortiSwitch-5003B boards
installed
Also visible on the front of the FortiGate-5060 chassis:
The location of the two hot-swappable FortiGate-5060 cooling fan trays.
The location of the front-replaceable air filter.
The Electrostatic discharge (ESD) socket, used for connecting an ESD wrist band
when working with the chassis.
FAN TRAY
1
2
3
4
5
6
FAN TRAY
1
2
3
4
5
6
FILTER TOP
12
5060SAP
SERIAL
1
SERIAL
2
RESET
ALARM
10/100
link/Act
ETH0
Service
RESET
STATUS
Hot Swap
link/Act
ETH0 ETH1
10/100
5000SM
SM1 SAP SM2
FortiGate 5060
1
1
1
1
Hot-swappable
cooling fan tray 2
Front-replacable
air filter
Hot-swappable
cooling fan tray 1
FortiGate-5001B
boards, slots 3,
4, 5, and 6
FortiSwitch-5003B
boards
slots 1 and 2
Primary
Shelf Manager
(SM 1)
Secondary
Shelf Manager
(SM 2) Slot Cover
Shelf Alarm
Panel (SAP)
ESD socket
Caution: Do not operate the FortiGate-5060 chassis with open slots on the front panel. For
optimum cooling performance and safety, the chassis slots must contain a FortiGate-5000
series board or an air baffle slot filler. For the same reason, both cooling fan trays and the
air filter should be installed while operating the chassis. As well both PEMs must be
installed in the back of the chassis.
FortiGate-5060 chassis FortiGate-5060 chassis back panel
FortiGate-5060 Chassis Guide
01-400-129494-20110912 9
http://docs.fortinet.com/Feedback
FortiGate-5060 chassis back panel
Figure 2 shows the back of a FortiGate-5060 chassis. The FortiGate-5060 chassis back
panel includes two redundant -48V to - 60 VDC power entry modules (PEMs) labelled
PEM A and PEM B. Fortinet ships the FortiGate-5060 chassis with PEM A and B installed.
The PEMs provide redundant DC power connections for the FortiGate-5060 chassis and
distribute DC power to the chassis slots and to the fan trays.
If you require redundant power you should connect both PEMs to DC power. If redundant
power is not required, you can connect PEM A or PEM B. Each PEM includes two power
terminals, one for connecting to -48V/-60 VDC and one for connecting to RTN. Use two-
hole lugs to connect the power terminals to DC power. Figure 2 shows the wiring required
to connect PEM B to a DC power source.
Figure 2: FortiGate-5060 chassis back panel (shows PEM B connected to DC power source)
The back panel includes the FortiGate-5060 chassis ground connector which must be
connected to Data Center ground. The FortiGate-5060 chassis also includes an ESD
socket on the back panel.
For detailed information about connecting power to the FortiGate-5060 chassis, see
“Connecting the FortiGate-5060 chassis to DC power and data center ground” on page 17
or “Connecting the FortiGate-5060 chassis to AC power using a FortiGate power
converter shelf” on page 20.
The back panel also contains 6 RTM slots numbered to correspond to the front panel
slots. The RTM slots are available for FortiGate-5000 RTM modules such as the
FortiGate-RTM-XB2 module or the FortiGate-RTM-XD2 module. When the
FortiGate-5060 chassis is shipped, these slots are covered by RTM air baffle slot covers.
RTM Air Baffle slot covers
ESD
socket
Chassis
Ground
Connector
(green)
PEM APEM B
PEM
RTN
Branch 1 Branch 2
-48/-60 V
PEM
RTN
Branch 1 Branch 2
-48/-60 V
Power
Entry Module
(PEM) B
Power
Entry Module
(PEM) A
-48V/-60 VDC
nom (black)
(lower)
RTN
(red)
(upper)
Physical description of the FortiGate-5060 chassis FortiGate-5060 chassis
FortiGate-5060 Chassis Guide
10 01-400-129494-20110912
http://docs.fortinet.com/Feedback
Physical description of the FortiGate-5060 chassis
The FortiGate-5060 chassis is a 5U chassis that can be installed in a standard 19-inch
rack. Table 1 describes the physical characteristics of the FortiGate-5060 chassis.
FortiGate-5060 shelf managers
The FortiGate-5060 chassis includes one or two redundant hot-swappable shelf
managers, located in the dedicated shelf manager slots near the top of the FortiGate-5060
front panel. The primary shelf manager is installed on the left (SM 1) the secondary shelf
manager (if present) is installed on the right (SM 2). The secondary shelf manager is
optional.
The shelf managers support redundant operation with automatic switchover. If both shelf
managers are operating normally, one acts as the active shelf manager and the other as
the standby. Usually the primary shelf manager would be the active shelf manager and the
secondary shelf manager would be the standby shelf manager. The shelf managers
monitor each other and either can trigger a switchover if necessary. The active shelf
manager performs all shelf manager functions. If the active shelf manager fails or is
removed, the standby shelf manager takes over all shelf manager functions.
The FortiGate-5060 shelf managers control chassis power allocation, monitor chassis
operating parameters, monitor and control chassis cooling, and can signal alarms if the
chassis encounters problems. All FortiGate-5000 modules installed in the chassis
communicate with the shelf managers.
Table 1: FortiGate-5060 chassis physical description
Dimensions 8.75 x 17 x 18.9 in. (22.2 x 43.2 x 48cm) (H x W x D) The
depth is from the fan tray handles on the front panel to the
connectors on the PEMs on the back panel.)
Shipping weight completely
assembled
with packaging
65.7 lb. (30 kg)
Chassis weight completely
assembled with shelf manager
and air baffles (5 front and 6
RTM)
50.7 lb. (23 kg)
Torque Rating 1.2 N m to 1.5 N m
Operating environment Temperature (long term): 41 to 104°F (+5 to 40°C)
Temperature (short term): 23 to 131°F (-5 to 45°C)
Relative humidity: 5 to 85% (Non-condensing)
Power consumption Maximum: 350 W (Power consumed by an empty chassis with
two fan trays, 2 shelf managers, one shelf alarm panel and 2
PEMs installed and operating with the fans running at full
speed.)
Power input 2x redundant -40.5 VDC to -60 VDC, 45 A total per PEM
Overcurrent Protection 30 A Fused Switches on PEMs
Cooling Capacity Front Boards: 300 W per board
RTM: 30 W per module
Protected Earth Test EN60950-1, test current 25 A, resistance <100mOhm
Hipot Test EN60950-1, 1000 V
FortiGate-5060 chassis FortiGate-5060 shelf managers
FortiGate-5060 Chassis Guide
01-400-129494-20110912 11
http://docs.fortinet.com/Feedback
The FortiGate-5060 shelf managers are factory installed. In most cases users do not have
to install or configure the shelf managers.
Each shelf manager has two ethernet interfaces (ETH 0 and ETH 1). You can connect to
ETH 0 from the shelf manager front panel. ETH 1 connects to the FortiGate-5060
backplane.
The shelf managers detect alarm conditions and communicate alarm signals to the
FortiGate-5060 shelf alarm panel. The shelf alarm panel also contains serial interfaces for
connecting to the shelf manager’s console ports.
The shelf managers are hot swappable. You can remove a shelf manager by opening the
extraction lever until the hot swap LED starts blinking. When the hot swap LED turns solid
blue you can remove the shelf manager from the FortiGate-5060 chassis.
Figure 3: FortiGate-5060 shelf manager front panel
Using the shelf manager CLI
You can use the shelf manager command line interface (CLI) to communicate with the
intelligent management controllers of the chassis, with boards in the chassis, and with the
shelf manager itself. The CLI is an IPMI-based set of commands that can be accessed
directly or through a higher-level management application or a script. Using the CLI, you
can access information about the current state of the chassis including current board
population, current sensor values, threshold settings, recent events, and overall chassis
health.
To get started using the shelf manager CLI, see “Using the shelf manager CLI” on
page 27.
Table 2: FortiGate-5060 shelf manager LEDs
LED State Description
ETH 0
ETH 1
10/100 Yellow The Ethernet interface is connected at 100 Mbps.
link/Act Green Blinking LED indicates network traffic.
Off No link.
STATUS Green This shelf manager is operating normally as the active shelf
manager. Usually the primary shelf manager operates as the
active shelf manager.
Red This shelf manager is operating normally as the backup shelf
manager. Usually the secondary shelf manager operates as the
standby shelf manager.
HOT SWAP Off The shelf manager is not ready to be removed.
Blue The shelf manager is ready to be removed.
Long blink The shelf manager is starting up after being inserted into the
chassis.
Short blink The shelf manager is shutting down in preparation for being
removed from the chassis.
10/100
link/Act
ETH0
Service
RESET
STATUS
Hot Swap
link/Act
ETH0 ETH1
10/100
5000SM
Retention
Screw
ETH 0 and 1 network
activity LEDs
ETH0
10/100/1000
base-T Ethernet
Status
LEDs
Handle
Reset
Button
Hot Swap
LED
FortiGate-5060 shelf alarm panel FortiGate-5060 chassis
FortiGate-5060 Chassis Guide
12 01-400-129494-20110912
http://docs.fortinet.com/Feedback
Shelf Manager fan and power control
The FortiGate-5060 shelf managers monitor the internal temperature of the
FortiGate-5060 chassis and adjust the operating speed of the FortiGate-5060 chassis
cooling fans as required.
When the chassis is first powered on all cooling fans run at full speed. Once the shelf
manager is up and running, the shelf manager reduces cooling fan speeds to maintain an
optimum temperature in the chassis. If shelf managers are not installed or not operating
correctly the FortiGate-5060 chassis cooling fans always operate at full speed.
FortiGate-5060 shelf alarm panel
The FortiGate-5060 shelf alarm panel (SAP), located at the top of the FortiGate-5060 front
panel, provides LED indicators of FortiGate-5060 alarms, a telco alarm connector, an
alarm LED reset button, and console access to the FortiGate-5060 shelf managers. The
LED alarm indicators include critical, major, and minor alarms as well as three user
defined alarms.
The alarm LED reset button (RESET) on the shelf alarm panel activates the Alarm Cutoff
(ACO) state. When ACO is activated, the active alarm LEDs blink and all of the alarm
relays are deactivated.
Figure 4: FortiGate-5060 shelf alarm panel front panel
5000SAP
SERIAL
1
SERIAL
2
RESET
ALARM
Retention
Screw
Telco Alarm
Interface
Alarm
LED Reset
Button
Minor Alarm (MIN) (Amber)
Major Alarm (MAJ) (Red)
Critical Alarm (CRT) (Red)
User 3 Alarm (Amber)
User 2 Alarm (Amber)
User 1 Alarm (Amber)
SERIAL 1 (Primary
Shelf Manager)
SERIAL 2 (Secondary
Shelf Manager)
FortiGate-5060 chassis FortiGate-5060 shelf alarm panel
FortiGate-5060 Chassis Guide
01-400-129494-20110912 13
http://docs.fortinet.com/Feedback
Figure 5 shows the connections between the primary and secondary shelf managers and
the shelf alarm panel.
Table 3: FortiGate-5060 shelf alarm panel LEDs
LED State Description
CRT
(critical)
Off Normal operation.
Red Indicates a critical alarm.
Blinking
Red
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
MAJ (major) Off Normal operation.
Red Indicates a major alarm.
Blinking
Red
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
MIN (minor) Off Normal operation.
Amber Indicates a minor alarm.
Blinking
Amber
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
USER3
USER2
USER1
Off Normal operation
Amber Indicates a user-definable alarm.
Blinking
Amber
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
Table 4: FortiGate-5060 shelf alarm panel connectors
Connector Type Speed Protocol Description
SERIAL 1 RJ-45 9600 bps,
8/N/1
RS-232
serial
Serial connection to the primary shelf manager
command line interface.
SERIAL 2 RJ-45 9600 bps,
8/N/1
RS-232
serial
Serial connection to the secondary shelf
manager command line interface.
ALARM micro
DB-15
male
N/A Telco
Form-c
The external dry relay Telco alarm interface
(48VDC) provides Telco form-c relay
connections for minor, major and critical power
faults. The cable required to connect to the
alarm interface is not supplied by Fortinet.
FortiGate-5060 shelf alarm panel FortiGate-5060 chassis
FortiGate-5060 Chassis Guide
14 01-400-129494-20110912
http://docs.fortinet.com/Feedback
Figure 5: Connections between the shelf managers and the shelf alarm panel
Shelf alarm panel telco alarms
The shelf alarm panel telco alarm interface relay circuits are capable of carrying 60 VDC
or 1 A with a max. rating of 30 VA. The shelf alarm panel accepts timed pulse inputs for
clearing minor and major alarm states. Reset is accomplished by asserting a voltage
differential from 3.3 V to 48 V for between 200 and 300 ms. The acceptance voltage range
is from 0 to 48 VDC continuous (handles up to 60 VDC at a 50% duty cycle). The current
drawn by a reset input does not exceed 12 mA.
The alarm LED reset button activates the alarm cutoff (ACO) state for major, minor, and
user-defined alarms. You cannot reset critical alarms with the alarm LED reset button.
When the ACO state is activated, active alarm LEDs blink and all of the alarm relays are
deactivated. The alarm reset button activates the ACO state but does not clear the alarm
completely.
Figure 6: The telco alarm connector (DB-15 male)
5000SAP
SERIAL
1
SERIAL
2
RESET
ALARM
Primary Shelf Manager (Right)
I²C-Switch
PCA9545
Buffer
LTC4300
ShMM-500
el
b
a
n
E
y
l
nO-retsaM
sub-C²I
e
cafretnIelos
noClaireS
Secondary Shelf Manager (Left)
I²C-Switch
PCA9545
elbanE
ylnO-re
tsaM
sub-
C²I
e
c
a
f
re
tn
Ielo
s
n
o
Clai
r
e
S
Buffer
LTC4300
ShMM-500
0HC
3HC
0HC
3HC
1
915
8
FortiGate-5060 chassis Air filter
FortiGate-5060 Chassis Guide
01-400-129494-20110912 15
http://docs.fortinet.com/Feedback
Air filter
The FortiGate-5060 chassis includes a front replaceable air filter. The filter provides 80%
dust arrestance and meets the requirements of the Telcordia Technologies Generic
Requirements GR-78-CORE specification. The filter must be installed for the
FortiGate-5060 chassis to operate normally. If the air filter is not locked into place the air
filter presence switch causes an alarm.
Air filters should be inspected regularly. If dirty or damaged, the filter should be disposed
of and replaced.
The air filter can be removed using the air filter handle on the front of the FortiGate-5060
chassis. To install a new filter, push the new filter into the guide rails at each side of the
shelf until the filter locks into place.
Table 5: Telco alarm connector pin assignment
Pin Name Description
1 AMIR+ MinorReset+
2 AMIR- MinorReset-
3 AMAR+ MajorReset+
4 AMAR- MajorReset-
5 ACNO CriticalAlarm - NO
6 ACNC CriticalAlarm - NC
7 ACCOM CriticalAlarm - COM
8 AMINO MinorAlarm -NO
9 AMINC MinorAlarm - NC
10 AMINCOM MinorAlarm - COM
11 AMANO MajorAlarm - NO
12 AMANC MajorAlarm - NC
13 AMACOM MajorAlarm - COM
14 APRCO PwrAlarm - NO
15 APRCOM PwrAlarm - COM
Shield Shelf-GND Shelf Ground
Cooling fan trays FortiGate-5060 chassis
FortiGate-5060 Chassis Guide
16 01-400-129494-20110912
http://docs.fortinet.com/Feedback
Cooling fan trays
The FortiGate-5060 chassis contains two identical hot-swappable cooling fan trays
installed on the left and right sides of the chassis. The chassis can run indefinitely with
only one fan tray operating. The fans move air in the right side of the chassis and out the
left side.
You can remove a fan tray by pressing the hot swap button on the fan tray front panel.
When the Hot Swap LED is solid blue unlock the latch and pull the fan tray out using the
extraction handle.
Each cooling fan tray contains six radial fans for cooling the boards and modules installed
in the FortiGate-5060 chassis. Fan speeds are monitored by a tachometer signal sent
from the cooling fan trays to the shelf manager. The shelf manager regulates the fan
speed by adjusting the DC voltage supplied to the fan trays.
Figure 7: Cooling fan tray front panel
Table 6: FortiGate-5060 fan tray LEDs and controls
LED/Control Description
OK (operate)
LED
Green when the fan tray is powered and operating normally.
Alarm LED Normally off. Turns red when there is a problem with the fan tray.
HS (hot swap)
LED
Normally off. Blinking blue indicates that the fan tray is entering the hot
swap mode. Solid blue indicates that the fan tray is in hot swap mode and
can be removed from the chassis.
HS (hot
swap) button
Press the HS button to enter hot swap mode. When the HS LED becomes
solid blue you can remove the fan tray from the chassis.
FAN TRAY
1
2
3
4
5
6
Hot swap
button
Hot swap LED
Alarm LED
OK LED
Latch
FortiGate-5060 Chassis Guide
01-400-129494-20110912 17
http://docs.fortinet.com/Feedback
Power connection and configuration
This chapter describes how to connect DC power to a FortiGate-5060 chassis.
If main DC power supplied by the data center in which the FortiGate-5060 chassis is to be
installed is not available, you can use a FortiGate power converter shelf to convert AC to
DC to supply DC power to the FortiGate-5060 chassis.
This chapter describes:
About data center DC power
Connecting the FortiGate-5060 chassis to DC power and data center ground
Connecting a FortiGate-5060 PEM to DC power
Connecting the FortiGate-5060 chassis to data center ground
Connecting the FortiGate-5060 chassis to AC power using a FortiGate power
converter shelf
Turning on FortiGate-5060 chassis power
About data center DC power
The FortiGate-5060 chassis is designed to be installed in a data center or similar location
that has available -48VDC power fed from a 30A listed circuit breaker (also called battery
power or main DC power). Fortinet expects that most FortiGate-5060 customers will be
installing their chassis in a data center or similar location that is already equipped with a
-48VDC power system fed from a 30A listed circuit breaker that provides power to existing
networking or telecom equipment. The FortiGate-5060 chassis is designed to be
connected directly to this DC power system.
In this document, data center DC power refers to a -48VDC power system that is already
available at the location at which the FortiGate-5060 chassis is being installed.
Connecting the FortiGate-5060 chassis to DC power and data
center ground
Connect the FortiGate-5060 chassis to r DC power using the redundant -48V to - 60 VDC
power entry modules (PEMs) on the FortiGate-5060 back panel labelled PEM A and
PEM B. The specified voltage range of the PEMs is -40.5 VDC to -60 VDC. The chassis
ships with both PEM A and B installed. The PEMs provide redundant DC power
connections for the FortiGate-5060 chassis and distribute DC power to the chassis slots
and to the fan trays.
Each FortiGate-5060 PEM includes two connectors for two power terminals that connect
power to different power zones in the FortiGate-5060 chassis. In the PEM, each power
terminal is protected by a 30A fused switch. The power zones are connected together and
should be connected to a single -48VDC power source with a 30A listed circuit breaker.
Each power zone supplies power to different FortiGate-5060 slots and cooling fan trays.
You should always connect both power zones.
Connecting a FortiGate-5060 PEM to DC power Power connection and configuration
FortiGate-5060 Chassis Guide
18 01-400-129494-20110912
http://docs.fortinet.com/Feedback
To connect the FortiGate-5060 PEMs to data center DC power you must use power
connectors that comply with the local electrical wiring code and the requirements of the
facility in which you are installing the FortiGate-5060 chassis.
Fortinet supplies two 3-ft. power cables with AWG-10 stranded wires and ring terminals:
Black for -48VDC and red for RTN. These cables should only be used to connect the
FortiGate-5060 PEMs to a FortiGate power convertor shelf if purchased with your
FortiGate-5060 chassis. If the power cable length needs to be longer than 3 ft., higher
gauge wires should be used.
Green AWG-6 wires are recommended for ground connections (not supplied with the
chassis).
If you are connecting both PEMs the -48VDC and RTN terminals on PEM A and PEM B
must be wired symmetrically. This means that the connections must be the same to both
PEMs.
FortiGate-5060 PEMs are hot-swappable, which means you can remove and replace a
defective PEM while the system is operating (assuming that the FortiGate-5060 system
has both PEMs connected for redundancy). It is not necessary to notify the software or
reset the system power. You can add, remove, or replace a second PEM without
interrupting FortiGate-5060 operation.
Connecting a FortiGate-5060 PEM to DC power
The following procedure describes how to connect power to PEM A. You can repeat this
procedure to connect PEM B.
Figure 8: Connecting a FortiGate-5060 PEM to DC power
DC Power Source
-48VDC
connector
RTN (positive)
red to power
source RTN
DC Power Source
RTN connector
PEM
RTN
Branch 1 Branch 2
-48/-60 V
-48V/-60 VDC
black to power
source -48VDC
Hot swap button
Hot swap LED
Power Switches
Alarm LED
OK LED
Power connection and configuration Connecting the FortiGate-5060 chassis to data center ground
FortiGate-5060 Chassis Guide
01-400-129494-20110912 19
http://docs.fortinet.com/Feedback
You need the following tools and equipment to connect a FortiGate-5060 PEM to data
center DC power:
A hex socket wrench is recommended for loosening and tightening the nuts on the
PEM power terminals.
An electrostatic discharge (ESD) preventive wrist strap with connection cord.
Two black AWG-10 stranded wires labelled -48V with attached Listed closed loop
single hole lugs with insulating boot suitable for minimum 10AWG copper wire, such as
3M model MH10-14RX.
Two red AWG-10 stranded wires labelled RTN with attached Listed closed loop single
hole lugs with insulating boot suitable for minimum 10AWG copper wire, such as 3M
model MH10-14RX.
To connect a FortiGate-5060 PEM to data center DC power
1Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal
surface on the chassis or frame.
2Turn off both power switches on the PEM.
3Remove the clear plastic cover from the PEM power connectors.
4Connect the DC power wires (see Figure 8):
Connect two black -48V power wires from the DC power source to the connectors
on the FortiGate-5060 PEM labeled -48V/-60 V (the lower connectors on the PEM).
Connect two red RTN return wires from data center RTN to the connectors on the
FortiGate-5060 PEM labeled RTN (the upper connectors on the PEM).
5Make sure the power wires are secured using tie wraps if required.
6If required, label the black wire -48V.
7If required, label the red wire RTN.
8Turn on the PEM switches.
Connecting the FortiGate-5060 chassis to data center ground
The FortiGate-5060 chassis includes a ground terminal on the lower left side of the
FortiGate-5060 back panel (see Figure 2 on page 9). The Shelf ground terminal provides
two threads (M6) with a 15.88 mm (5/8“) spacing between thread centers to connect a
two-hole lug. This connector must be connected to data center ground.
You need the following tools and equipment to connect the FortiGate-5060 chassis to
ground:
Table 7: FortiGate-5060 PEM LEDs and controls
LED/Control Description
HS (hot swap)
LED
Normally off. Blinking blue indicates that the PEM is entering the hot swap
mode. Solid Blue indicates that the PEM is in hot swap mode and can be
removed from the chassis.
Alarm LED Normally off. Turns red when there is a problem with the power source, or if
one or more of the 8 PEM fuses are blown or missing.
OK (operate)
LED
Green when the PEM is powered and operating normally.
HS (hot
swap) button
Press the HS button to enter hot swap mode. When the HS LED becomes
solid blue you can remove the PEM from the chassis.
Connecting the FortiGate-5060 chassis to AC power using a FortiGate power converter shelf Power connection and configuration
FortiGate-5060 Chassis Guide
20 01-400-129494-20110912
http://docs.fortinet.com/Feedback
A number 2 Phillips screwdriver.
An electrostatic discharge (ESD) preventive wrist strap with connection cord.
One green AWG-6 stranded wire with M6 two-hole terminal lug with 45° angle tongue
with a 15.88 mm (5/8“) spacing between hole centers.
Figure 9: Connecting a FortiGate-5060 chassis to data center ground
To connect the FortiGate-5060 chassis to data center ground
1Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal
surface on the chassis or frame.
2Connect the green ground wire from the data center ground to the ground connector on
the FortiGate-5060 chassis (see Figure 9).
3Secure the ground wire to the chassis.
4Optionally label the wire GND.
Connecting the FortiGate-5060 chassis to AC power using a
FortiGate power converter shelf
If data center DC power is not available, you can use a Fortinet-supplied power converter
shelf with hot swappable power supplies to convert AC power to DC power. FortiGate
power converter shelves and power supplies are not supplied with the FortiGate-5060
chassis and must be purchased separately.
As already mentioned, the FortiGate-5060 chassis ships with two 3-ft. power cables with
AWG-10 stranded wires and ring terminals: Black for -48VDC and red for RTN. These
cables should only be used to connect the FortiGate-5060 PEMs to a FortiGate power
convertor shelf if purchased with your FortiGate-5060 chassis. If the power cable length
needs to be longer than 3 ft., higher gauge wires should be used.
Turning on FortiGate-5060 chassis power
If you are using a power converter shelf, connect the power convertor shelf to AC power
and verify that it is operating correctly.
If you are using data center DC power, turn own the power to the chassis according to the
requirements of your data center DC power system.
Once the FortiGate-5060 chassis is connected to DC power you can turn on power to the
chassis by turning on the switches on the PEMs (see Figure 8 on page 18 for location of
the switches on each PEM).
Data Center
ground
connector
(Central office
ground system)
Chassis
Ground
Connector
(green)
FortiGate-5060
Ground
Connector
(green)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81

Fortinet FortiGate-5060 Chassis Manual

Type
Chassis Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI