Pulsar POE5524B - v1.0 Operating instructions

Type
Operating instructions
POE5524B
v.1.0
PoE 27,6V/4x1A/2x7Ah/PoE
Buffer switch mode power supply unit
EN
Edition: 2 from 16.09.2013
Supercedes the edition: 1 from 06.02.2012
www.pulsar.pl POE5524B
2
Features:
27,6VDC/4x1A uninterruptible power supply
fitting battery: 2x 7Ah/12V
wide range of mains supply: 176÷264V
high efficiency 83%
battery charging and maintenance control
excessive discharging (UVP) protection
battery charge current 0,5A/2A
battery output full protection against short-circuit
and reverse polarity connection
intended for operation in 10Mbit/s and 100Mbit/s
networks
voltage control at the AUX1 ÷ AUX4 outputs
AW output of the PSU failure, tripped by:
short-circuit (SCP)
overload (OLP)
LED indication
protections:
SCP short-circuit protection
OVP over voltage protection
overtension protection
against sabotage
OLP overload protection
warranty
– 2 year from the production date
CONTENTS:
1. Technical description.
1.1 General description
1.2 Block diagram
1.3 Description of PSU components and connectors.
1.4 Specifications
2. Installation.
2.1 Requirements
2.2 Installation procedure
3. Operating status indication.
3.1 LED indication of operating status
3.2 Technical outputs
4. Operation and use.
4.1 Overload or short circuit of the PSU output
4.2 Disconnection of discharged battery
4.3 Maintenance
1. Technical description.
1.1 General description.
A buffer PSU is intended for an uninterrupted supply to mx. 4 net camcoders requiring stabilised voltage of
24 V DC (+/-15%). The PSU provides voltage of U=27,6 V DC with current capacity:
1. Output current 4x1A + 0,5A battery charging
2. Output current 4x0,87A + 0,2A battery charging
Total device current + battery: 5,5A max.
In case of power decay, a battery back-up is activated immediately. The PSU is constructed based on the
switch mode PSU, with high energy efficiency. The PSU is housed in a metal enclosure (colour RAL 9003) which
can accommodate two 2x7Ah/12V batteries. A micro switch indicates door opening (front cover). Supply to the
camcorders is by means of network cabling, with twisted pairs 4/5 (+) and 7/8 (-), which, in accordance with the
Ethernet network standard, are not intended for data transmission (data transmission uses 1/2 and 3/6 twisted
pairs). The PSU cannot be used in Gigabit Ethernet networks, where all twisted pairs take part in a data transition.
The power supply is also adapted to the mounting of the DCDC20 (5V÷18V/2A÷1,3A)
converter.
www.pulsar.pl POE5524B
3
1.2 Block diagram.
Fig. 1. Block diagram of the PSU.
1.3 Description of PSU components and connectors.
Table 1. Elements of the PSU pcb (refer to chart 2).
Element no. Description
[1]
Connector:
IN – module supply
AW - technical output of the PSU operating status – OC type (open collector)
level hi-Z = status: failure
level L = status: correct operation
[2]
LED indication:
green diode – indicates voltage at the IN input
red diode – indicates AW failure
[3]
connector of the additional, external LED indication
[4]
network inputs (Ethernet)
[5]
network outputs (Ethernet + supply) – for connecting the camcorders
[6]
L1 ÷ L4 green LEDs: indicate voltage in individual AUX outputs (under normal status,
the diodes are permanently illuminated)
[7]
pins – for melting fuse/PTC selection
[8]
F1, F2, F3, F4 – fuses in the AUX (+) circuit
Tab. 1. Description of the PoE module components.
www.pulsar.pl POE5524B
4
Fig. 2. Lay-out of the elements.
www.pulsar.pl POE5524B
5
Fig.3. The view of the PSU.
Fig.3. The view of the PSU.
www.pulsar.pl POE5524B
6
Table 2. Elements of the PSU (refer to Fig. 3.)
Element no. Description
[1]
Switch-mode power supply unit
[2]
LED indicating PSU operation
[3]
P1 potentiometer, output voltage adjustment
[4]
PoE module
[5]
Battery connectors +BAT = red, - BAT = black
[6] TAMPER – against sabotage protection contact (NC)
[7]
Selection jumper for charging current:
Ibat =0,5 A
Ibat =2A
Legend: jumper installed, jumper removed.
Factory setting: Ibat =0,5 A (jumper installed)
1.4 Specifications:
- electrical parameters (tab.3)
- mechanical parameters (tab.4)
- operation safety (tab.5)
- operating parameters (tab.6)
Electrical parameters (tab. 3)
Mains supply 176÷264V AC
Current up to 1,4AA@230V AC
Power frequency 50÷60Hz
Supply power 155W max.
Efficiency 83%
Output voltage 27,6 V DC – buffer operation
19V÷27,0V DC – battery-assisted operation
Output current
4x 0,4A + 0,5A battery charge
4x 0,87A + 2A battery charge
Output current t
AMB
<30°C 4x 1A + 0,2A battery charge - refer to chart 1
4x 0,87A + 0,2A battery charge - refer to chart 1
Output current t
AMB
=40°C 4x 0,85A + 0,5A battery charge - refer to chart 1
4x 0,45A + 2A battery charge - refer to chart 1
Voltage adjustment range 24÷28V DC
Ripple 150 mV p-p max.
Battery charging current 0,5A/2A max. @ 2x7Ah (± 5%)
Short-circuit protection SCP electronic
Overload protection OLP 4xF1A or 4xPTC 1,1A
Battery circuit protection OLP polymer fuse
Overvoltage protection OVP 4x varistor
Excessive discharge protection UVP <19,0 V (± 5%) –– disconnection of the battery terminal
Power status LED indication Yes
Technical outputs:
- AW - indicates fuse failure
- TAMPER - indicates enclosure opening
- OC type, 50mA max.
normal status: level L (0V), failure: level H (hi-Z)
(automatic recovery after a return to correct operation)
- microswitch, NC contacts (enclosure closed),
0,5A@50V DC (max.)
F1 ÷ F4 fuses F 1A /250V or PTC 1,1A
Mechanical parameters (tab. 4).
Enclosure dimensions 320 x 304 x 90+8 (325 x 309 x 98) (WxHxD)
Fixing Refer to Fig. 3.
Fitting battery 2 x 7Ah/12V (SLA) max.
Net/gross weight 2,80kg / 3,10kg
Enclosure Steel plate DC01, thickness: 0,7mm, colour: RAL 9003
Closing Cheese head screw (at the front), x2
Connectors Power-supply: Φ0,4-2,5 (AWG 26-10)
Battery outputs: BAT: 6,3F-2,5, 50cm
PoE module: Φ0,5-2,5 (AWG 24-12)
AUX1...4 outputs: RJ45 8pin
TAMPER output: Φ0,8, 50cm
Notes The enclosure does not adjoin the assembly surface so that cables
can be led.
www.pulsar.pl POE5524B
7
Operation safety (tab.5).
Protection class PN-EN 60950-1:2007 I (first)
Degree of Protection PN-EN 60529: 2002 (U) IP20
Electrical strength of insulation:
- between input and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 M, 500V/DC
Operating parameters (tab.6).
Operating temperature -10ºC...+40ºC
Storage temperature -20ºC...+60ºC
Relative humidity 20%...90%, without condensation
Vibrations during operation unacceptable
Impulse waves during operation unacceptable
Direct insulation unacceptable
Vibrations and impulse waves during transport Wg PN-83/T-42106
Chart 1. Acceptable output current of the PSU depending on ambient temperature.
2. Installation
2.1 Requirements
The buffer PSU shall be mounted by a qualified installer with appropriate permissions and qualifications for
230V/AC installations and low-voltage installations (required and necessary for a given country). The device shall
be mounted in confined spaces, according to the environment class II, with normal air humidity (RH=90% max.
without condensation) and the temperature from -10°C to +40°C. The PSU shall operate in a vertical position that
guarantees sufficient convectional air-flow through ventilating holes of the enclosure.
Before installation, prepare a PSU load balance. During normal operation, the total current
drawn by the device may not exceed I = 4A. Maximum battery charging current: 2 A. Total
device current + battery: 5,5 A max.
As the PSU is designed for a continuous operation and is not equipped with a power-switch, therefore an
appropriate overload protection shall be guaranteed in the power supply circuit. Moreover, the user shall be
informed about the method of unplugging (usually through assigning an appropriate fuse in the fuse-box). The
electrical system shall follow valid standards and regulations.
The PSU is intended for operation in Ethernet networks, with capacity of 10Mbit/s or 100Mbit/s (so-called
Fast Ethernet). It cannot bee used within the 1000Mbit/s capacity networks (so-called Gigabit Ethernet). The
connection between the camcorder and the PSU is to be done with a cable of UTP-3 category (in a network where
the data transmission speed amounts to 10Mbit/s) or UTP-5. Due to lower cable resistance, it is recommended to
use UUPT-5 type cables, also in the networks where the data transmission speed does not exceed 10Mbit/s
(especially when there is a significant distance between the PSU and its receiver).
www.pulsar.pl POE5524B
8
2.2 Installation procedure
1. Before installation, cut off the voltage in the 230V power-supply circuit.
2. Mount the PSU in a selected location and connect the wires.
3. Connect the power cables (~230Vac) to L-N clips of the PSU. Connect the ground wire to the clip marked by the
earth symbol PE. Use a three-core cable (with a yellow and green PE protection wire) to make the connection.
Lead the cables to the appropriate clips through the insulating bushing of the connection board.
The shock protection circuit shall be performed with a particular care, i.e. the yellow and
green wire coat of the power cable shall stick to one side of the terminal - marked with
symbol on the PSU enclosure. Operation of the PSU without the properly made and
fully operational shock protection circuit is UNACCEPTABLE! It can cause a device
failure or an electric shock.
4. Connect the network cables (Ethernet) to the PoE module: the supply power appears only in the AUX power
outlets, and that is where the camcorders are to be plugged.
5. With F1/PTC1 – F4/PTC4 jumpers, select a sort-circuit or overload protection type. A jumper in the Fx position
the melting fuse is active, PTCx position – the PTC fuse is active.
6. If necessary, make technical connections:
- AW - technical output of the PSU operating status, indicates voltage absence at any of the outputs
(AUX1 ÷ AUX4)
- TAMPER - indicates enclosure opening
7. Connect the battery in accordance with the markings (colours)
- battery output (+V): BAT+ / red,
- battery output (0V): BAT - / black
8. Check the PSU operation indicator: green LED (green on the PoE module)
9. Check the PSU output voltage:
- the PSU voltage without load should amount to U=27, 6V DC.
10. Once the tests and operation control have been completed, the enclosure can be locked.
3. Operating status indication.
3.1 LED indication of operating status
The PSU is equipped with seven diodes in the front cover.
RED LED:
on – the PSU is supplied with 230V AC
off – no 230V AC supply
RED LED:
on – DC at the output of the switch-mode PSU
off – no DC at the output of the switch-mode PSU
RED LED:
on – fuse failure at one of the AUX1… AUX4 outputs
off – no failure
GREEN LED:
on – DC at the AUX1… AUX4 output
off – no DC at the AUX1… AUX4 output
Additionally, the PSU is equipped with LEDs inside the enclosure – Fig. 2 and 3.
Operating status indication of the switch mode power supply:
Green LED indicates correct operation of the switch mode power supply.
Indication of voltage at the IN output of the PoE module – green LED.
www.pulsar.pl POE5524B
9
Green diodes L1 ÷ L4 - indicate voltage at any of the module outputs (L1 for AUX1, etc.) If any of the Lx diodes is
off, it means that the shot-circuit or overload protection of a given circuit has been activated.
3.2 Technical outputs:
The PSU is equipped with indication outputs which inform about AC power failure or tampering inside the
power supply.
AW - technical output of the power supply: OC type indicates the PSU failure (short-circuit or overload).
In a normal status (under proper operation), the output is fault to ground (status L – 0V), in case of
In case
of power loss, the PSU output is switched into hi-Z
(high impedance) state.
TAMPER - output indicates opening the power-supply unit: output as volt-free (potential-free) contacts
which indicate power-supply unit door status, unit closed: NC, unit opened: NO
4. Operation and use.
4.1 Overload or short circuit of the PSU output
The AUX1 – AUX4 outputs of the connector strip is equipped with an independent short-circuit / overload
protection due to melting or polymer fuses PTC (the selection of the fuse is done by a certain positioning of the
Fx/PTCx jumper). If the load of the PSU exceeds I
max
(load 110% ÷ 150% @25ºC of the PSU power), the output
voltage is automatically cut off and indicated by the Lx green diode off. . To restore the output power and to protect
the PTC, cut off the output load for approximately 1 minute (this amount of time is necessary for the PTC fuse to
cool down). If a melting fuse was used for the protection, it shall be replaced by a new one, of the same type and
rated current.
4.2 Disconnection of discharged battery.
The PSU is equipped with the discharged battery disconnection system. During the battery-assisted operation,
reducing voltage below 19V at the battery terminals will cause battery disconnection.
4.3 Maintenance
Any and all maintenance operations may be performed following the disconnection of the PSU from the power
supply network. The PSU does not require performing any specific maintenance measures, however, in the
case of significant dust rate, its interior is recommended to be cleaned with compressed air. Periodically, the
battery condition ought to be checked. In case of any faults (capacity loss, too high internal resistance), the
battery needs to be exchanged. In case of fuse replacement, use a replacement of the same parameters.
www.pulsar.pl POE5524B
10
www.pulsar.pl POE5524B
11
WEEE MARK
According to the EU WEE Directive – It is required not to dispose of electric or
electronic waste as unsorted municipal waste and to collect such WEEE separately.
The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be
disposed of but recycled according to the applicable law.
GENERAL WARRANTY CONDITIONS
1. Pulsar K. Bogusz Sp.j. (the manufacturer) grants a two-years warranty for the equipment, counted from the device’s
production date.
2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the
manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects,
unless such defects have been reported within the warranty period (item 1).
3. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office
of the manufacturer.
4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the
defect.
5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenienve,
however not later that within 14 days from the delivery to the service centre of the manufacturer.
6. The repair period mentioned in item 5 may be prolonged, if there are no technical possibilities to carry out the repairs,
or if the equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.
7. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively.
8. The warranty does not cover the defects of the equipment, resulting from:
- reasons beyond the manufacturer's control,
- mechanical damage,
- improper storage and transport,
- use that violates the operation manual or equipment’s intended use
- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,
- improper installation and configuration (in defiance with the manual),
9. The warranty is void in any of the following circumstances:
- construction changes
- repairs carried out by any unauthorized service center
- damage or removal of warranty labels
- modifications of the serial number
10. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to
the wholesale prices suggested by the manufacturer on the day of purchase.
11. The manufacturer takes no reponsibility for the defects that result from:
- the damaging, malfunctioning or inability to operate the equipment
- defects that result from using the equipment outside its stated specifications and operating parameters failing to abide
by the recommendations and requirements contained in the manual, or the use of the equipment.
Pulsar K.Bogusz Sp.j.
Siedlec 150, 32-744 Łapczyca, Poland
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
e-mail: biuro@pulsar.pl, [email protected]l
http:// www.pulsar.pl, www.zasilacze.pl
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Pulsar POE5524B - v1.0 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI