1 Introduction
1.1 Purpose of the Design Guide
This design guide for Danfoss VLT
®
DriveMotor FCP 106
and FCM 106 is intended for:
•
Project and systems engineers.
•
Design consultants.
•
Application and product specialists.
The design guide provides technical information to
understand the capabilities of the frequency converter for
integration into motor control and monitoring systems.
The purpose of the design guide is to provide design
considerations and planning data for integration of the
frequency converter into a system. The design guide caters
for selection of frequency converters and options for a
diversity of applications and installations.
Reviewing the detailed product information in the design
stage enables developing a well-conceived system with
optimal functionality and
eciency.
VLT
®
is a registered trademark.
1.2
Additional Resources
Available literature:
•
VLT
®
DriveMotor FCP 106/FCM 106 Operating
Instructions, for information required to install and
commission the frequency converter.
•
VLT
®
DriveMotor FCP 106/FCM 106 Design Guide
provides information required for integration of
the frequency converter into a diversity of
applications.
•
VLT
®
DriveMotor FCP 106/FCM 106 Programming
Guide, for how to program the unit, including
complete parameter descriptions.
•
VLT
®
LCP Instruction, for operation of the local
control panel (LCP).
•
VLT
®
LOP Instruction, for operation of the local
operation pad (LOP).
•
Modbus RTU Operating Instructions and VLT
®
DriveMotor FCP 106/FCM 106 BACnet Operating
Instructions for information required for
controlling, monitoring, and programming of the
frequency converter.
•
The VLT
®
PROFIBUS DP MCA 101 Installation Guide
provides information about installing the
PROFIBUS and troubleshooting.
•
The VLT
®
PROFIBUS DP MCA 101 Programming
Guide provides information about conguring the
system, controlling the frequency converter,
accessing the frequency converter, programming,
and troubleshooting. It also contains some typical
application examples.
•
VLT
®
Motion Control Tool MCT 10 enables congu-
ration of the frequency converter from a
Windows
™
-based PC environment.
•
Danfoss VLT
®
Energy Box software, for energy
calculation in HVAC applications.
Technical literature and approvals are available online at
vlt-drives.danfoss.com/Support/Service/.
Danfoss VLT
®
Energy Box software is available at
www.danfoss.com/BusinessAreas/DrivesSolutions, PC software
download area.
1.3 Symbols, Abbreviations, and
Conventions
The following symbols are used in this manual.
NOTICE
Indicates important information to be regarded with
attention to avoid mistakes or to avoid operating
equipment at less than optimal performance.
* Indicates default setting.
Degree of
protection
The degree of protection is a standardised
specication for electrical equipment that
describes the protection against the ingress of
foreign objects and water (for example: IP20).
DIx DI1: Digital input 1.
DI2: Digital input 2.
EMC Electromagnetic compatibility.
Error Discrepancy between a computed, observed, or
measured value or condition, and the specied
or theoretically correct value or condition.
Factory
setting
Factory settings when the product is shipped.
Fault An error can cause a fault state.
Fault reset A function used to restore the frequency
converter to an operational state after a detected
error is cleared by removing the cause of the
error. The error is then no longer active.
MM Memory module.
Introduction Design Guide
MG03M202 Danfoss A/S © 06/2016 All rights reserved. 5
1 1