SERVICE INSTRUCTIONS
Field Retrofit 8884 AIRPOT
751
To update an old-style airpot to the new style, order kit # 86491.
To repair a new-style airpot, order kit# 83160NS.
The following items are compatible with both old- and new-style
airpots:
ITEM PART # DESCRIPTION
3. #83162 PUMP GASKET
4. #83159 HINGE ROLL PIN
5. #83162 HINGE
6. #83158 PUSH PLATE
7. #83156 PUMP BELLOWS
8. #83351 SPOUT GASKET
AIRPOT 8884 PARTS BREAKDOWN
ITEM PART # DESCRIPTION
1 83155NS TOP AND PUMP ASSEMBLY, COMPLETE,
NEW-STYLE
2 83160NS REPAIR KIT (for new-style only: includes top
and pump assembly plus spout)
3 83162 GASKET, PUMP
4 83159 ROLL PIN, HINGE
5 83161 HINGE
6 83158 PUSH PLATE
7 83156 BELLOWS
8 83351 GASKET, SPOUT
9 86492NS SHOULDER AND HANDLE ASSEMBLY,
COMPLETE, NEW-STYLE
10 86491 RETROFIT KIT, (convert old-style to new style:
includes complete top and pump assembly,
spout assembly, and shoulder and handle
assembly)
p/n 76508 Rev. A ECN-13394
I
751 080211 cps
1 of 2
3
4
5
6
7
8
9
1
10
2
SPOUT
(ref.)
TANK
(ref.)
TANK GASKET
(ref.)
RETROFIT AIRPOT
1. Open top of airpot. Remove the old spout. Save the spout gasket and
discard the remainder of the spout.
2. Remove and discard the old top and pump assembly.
3. Remove three rubber plugs from the inside lip of the old shoulder.
Remove three screws holding the shoulder to the tank. Save the screws,
rubber plugs and tank gasket. Discard the old shoulder and handle
assembly.
4. Assemble handle to new shoulder.
a. With the "bow" of the handle under the spout area, line-up the keyed
fittings on the handle with the matching holes in the shoulder.
Push in until fully seated.
b. Rotate the handle until it is above the shoulder.
5. Be sure the tank gasket is in place, then install the shoulder on the tank.
Tighten the screws and install the rubber plugs.
6. Install the new top and pump assembly.
7. Slide the spout gasket in place then insert and lock the spout into the airpot.
Close the top.
Procedure is complete
IMPORTANT:
Be sure to save the existing spout
gasket (item #8).
2 of 2
RUBBER
PLUG (3 pl)
SCREW (3 pl)
SHOULDER
HANDLE
GASKET
TANK
751 76508 Instr Retro 8884