17
Sensor operation
1) Switch light ON (when light is OFF):
Turn switch OFF and ON once.
Light stays on for the period selected.
2) Switch light OFF (when light is ON):
Turn switch OFF and ON once.
The light goes out or switches over to sensor
mode.
Manual override function
2 x aus/an
4 Stunden
5 sec. – 15 min.
1 x OFF/ON
IS 3180 IS 3360 IS 345
Dimensions: (l x w x h) 95 x 95 x 65 mm
Output: • 2000 W max., VDE tested
(resistive load, e.g. filament bulb)
• 10 AX max., VDE tested (fluorescent tube)
• 900 W max. (series corrected)
• 500 W max. (parallel corrected,
at C = 45.6 µF
• 600 W max. (electronic ballasts, capacitive,
e.g. low-energy lamps, 8 each max.)
Mains power: 230 – 240 V, 50 Hz
Recom. mounting height: 2 m 2.5 m 3 m
Angle of coverage: 180° horizontally 360° horizontally 12 x 4 m radially
90° vertically 180° vertically 20 x 4 m tangentially
Reaches: – 20 m max. all-round 20 x 4 m max.
Basic setting 1: 4 – 8 m max. – –
Basic setting 2: 8 – 20 m max. – –
Detection levels: 7 10 5
Switching zones: 448 1416 280
Twilight setting: 2 – 2000 lux 2 – 2000 lux 2 – 2000 lux
Time setting: 5 sec. – 15 min. 5 sec. – 15 min. 5 sec. – 15 min.
Manual override: selectable (4 h) selectable (4 h) selectable (4 h)
Enclosure: IP 54 IP 54 IP 54
Temperature ranging from: - 20° C bis + 50° C - 20° C bis + 50° C - 20° C bis + 50° C
Technical specifications
Manual override
1) Select manual override :
Turn switch OFF and ON twice. The lamp is
set to stay on for 4 hours (red LED lights up
behind the lens). Then it returns automatically
to sensor mode (red LED off).
2) Deactivate manual override:
Turn switch OFF and ON once. The light goes
out or switches over to sensor mode.
2 x aus/an
4 Stunden
4 hours
2 x OFF/ON
If a mains switch is installed in the mains supply
lead, the light is capable of the following func-
tions in addition to the simple ON/OFF function:
Important: The switch should be actuated in
rapid succession (in the 0.5 – 1 sec. range).
16
The system can be put into operation once the
mains power has been connected and the unit
is closed. Two setting options are concealed
behind the decorative faceplate.
Important: Only select time and twilight
setting with the lens in place.
Functions
ens
c.
ted
is
ew
no
u-
se
o-
on
e
ec.)
e),
es).
GB
Teach mode:
At the light level at which you want the Sensor
to respond to movement, the control should
be set to . After 10 sec. the value of the
ambient brightness is saved.
This motion detector is equipped with an inte-
grated anti-glare protection feature requiring the
following course of action: If the function test is
performed in daylight, the light threshold adjust-
ment screw can be set to night-time operation.
No movement must take place in the detection
zone within the selected light 'ON' time and
60 sec. thereafter or the lamp with continue
to shine. Exactly the same procedure must be
followed if any change is made to the twilight
threshold.
(factory setting:
daylight operation
2000 lux)
Twilight setting (response threshold)
2 – 2000 lux
(factory setting:
approx. 5 sec.)
Time setting (switch OFF delay)
5 sec. – 15 min.
The chosen light ON time can be varied conti-
nuously from approx. 5 sec. to a maximum of
15 min. (The light leaves the factory set to the
shortest time.) Any movement detected before
this time elapses will re-start the timer.
Pulse function
The pulse function activates the output for
2 sec. (e.g. for staircase lighting time switches).
The desired response threshold of the light can
be infinitely adjusted from approx. 2 – 2000 lux.
Turn control fully anticlockwise to select night-
time operation at about 2 lux. Turn control fully
clockwise to select teach mode, shortly before
this position means daylight operation at about
2000 lux. (The light leaves the factory set to
daylight operation.)
BDAL_IS3180_24spr 25.01.2010 15:33 Uhr Seite 17