BIG 101x
Version: 2010/12/01 33
2 Installation
2.1 Minimum system requirements for installation of the BIG 101x
• Power socket providing nominal voltage range 100 V … 240 V / 50 Hz … 60 Hz
• 1-4 copper wire pairs for the eSHDSL-WAN-connection
• Notebook or PC running on OS Windows
®
98 SE or any later versions; MAC; Linux
and full-duplex network interface card (interface: 10/100Base-T); CPU: Pentium II
®
,
500 MHz or higher
• diverse tools (water-level, pencil, drilling machine, drill Ø 6 mm, screwdriver, pliers)
2.2 Scope of delivery
Below parts are included in delivery:
• Packaging material
• BIG 1011 (1-Port SHDSL, Order No. 900212) or
BIG 1012 (2-Port SHDSL, Order No. 900213) or
BIG 1014 (4-Port SHDSL, Order No. 900214)
• Mains unit (mains lead 1.5 m)
• Network cable (3 m, yellow)
• Short operating manual
• Toolkit bag for wall mounting (2 screws incl. dowels)
2.3 Selecting the place of installation / Fixing the device
The device BIG 101x can be mounted to the wall or installed as desktop unit. Before you start
installing the unit, please read through the following instructions:
• Make sure that all parts are complete and in faultless condition.
Defective parts must not be used.
• Select a place of installation which is dry and not exposed to direct sun radiation.
• Do not conceal the ventilation slots on the BIG 101x.
The BIG 101x has been designed for in-house use in closed rooms and should be mounted to
the wall, if possible. The BIG 101x should be placed close to the copper wire pairs coming
from the SHDSL-DSLAM (junction socket) and next to a mains socket. Since the BIG 101x
is determined for continuous operation, it has no mains switch. For disconnection from the
electricity grid, just remove the plug-in power supply unit. So the wall power supply should
always be easily accessible.
Prior to wall mounting, make sure that there are no concealed supply lines (power, water, gas,
telephone, coaxial or fiber cable) at the intended installation place. During operation, the
BIG 101x is markedly warming up, but this operating temperature is not dangerous at all.
However, to provide for unimpeded heat dissipation, the BIG 101x must not be installed into
a fully closed casing, lacking of a sufficiently dimensioned breather hole. For the same reason
the device shall also be protected from intensive heating, caused e.g. by heating appliances or
direct sun radiation. Further, do not expose the modem to a very humid or dusty environment.