  • Hello! I am an AI chatbot trained to assist you with the NEC PlasmaSync® 42XM4 Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
NEC Europe Ltd
PDP Department
42XM4 Installation Guide
42” Plasma Display Rev 1.0
www.neceurope.com
Contents:
Product Description and Notes Page 1
Ventilation Requirements
Page 2
Display Dimensions
Front, Top & Bottom Page 3
Rear
Page 4
Left & Right Side
Page 5
Display Dimensions w/Optional Speakers and Stand
Page 6
Connections
Page 7
Control Codes
Page 8
Product Description
Type: Plasma Display. Screen Surface: Anti-Reflective.
Resolution: 1024x768 (XGA). Dimensions: 1022(W) x 610(H) x 98(D) mm.
Aspect Ratio: 16:9. Weight: 30Kg.
Color Correction: AccuCrimson Color Filter. Power Consumption: 285W (Typ).
EMI: Class B.
Notes
This document is intended to be used as a reference guide to supply useful information for a design or installation. It is not
intended to be a step-by step procedure for installation.
4:3 sources can be displayed on the 16:9 screen in either normal aspect ratio with bars on the left or right, or stretched horizontally
to fill the screen using the menus (see “Aspect Modes” in menus and user manual)
To avoid image retention or burn in please refer to the Phosphor disclaimer and operating manual provided with this product. NEC
shall accept on responsibility for the misuse of this product.
Drawing distances are in inches, for millimeters multiply by 25.4.
Distances may vary ±5%.
Maximum Tilt Angles
Below are the maximum angles that the display can be tilted in both landscape and portrait mode
Landscape 30°
Portrait 10°
Max Tilt
PX-42XM4 Page 1 of 8
NEC Europe Ltd
PDP Department
42XM4 Installation Guide
42” Plasma Display Rev 1.0
www.neceurope.com
Ventilation Requirements (all models)
Dimensions below are minimum required for proper ventilation.
NOTE: The ventilation space should not be covered or closed off at the front of the opening. If for some reason the
opening needs to be covered, other means of ventilation will need to be incorporated into the design. Contact NEC for
design review and recommendations.
PX-42XM4 Page 2 of 8
NEC Europe Ltd
PDP Department
42XM4 Installation Guide
42” Plasma Display Rev 1.0
www.neceurope.com
Display dimensions
40.24
2
4
.
0
37.48
2
1
.
1
8
17.21
LED IR
12.280.79
0.79
0.79
0.79
0.79
CONTROL BUTTONS
AC INLET
POWER BUTTON
SPEAKER TERMINAL
2
0
.
3
(
S
C
R
E
E
N
A
R
E
A
)
36.28 (SCREEN AREA) 1.98
1
.
9
4
2
0
.
1
8
"
FILTER SURFACE
1
2
.
0
1
14.61 5.51
2.251.59
PX-42XM4 Page 3 of 8
NEC Europe Ltd
PDP Department
42XM4 Installation Guide
42” Plasma Display Rev 1.0
www.neceurope.com
Display dimensions (cont.)
F
F F
F
F
F
REAR VIEW
AC IN
20.87
4
.
9
6
5
.
1
2
4
.
9
6
for mount
8 - M4*16 Max
17.52
0
.
8
7
4
.
0
2
for PC
4 - M4*10 Max
3
.
0
1
9
.
1
2
.
0
20.87
37.56
4 - M8*14 Max
for speaker
PX-42XM4 Page 4 of 8
NEC Europe Ltd
PDP Department
42XM4 Installation Guide
42” Plasma Display Rev 1.0
www.neceurope.com
Display dimensions (cont.)
LEFT SIDE VIEW
RIGHT SIDE VIEW
0.0
1.59
3.86
0.60
0.5
3
.
5
4
8
.
4
6
1
1
.
6
0
20.10
0.50
1.87
PX-42XM4 Page 5 of 8
NEC Europe Ltd
PDP Department
42XM4 Installation Guide
42” Plasma Display Rev 1.0
www.neceurope.com
Dimensions with optional speakers [PX-42SP1U] and stand [PX-ST1U]
TOP VIEW
RIGHT SIDE VIEW
1
.
3
8
2.91
3.540.04
3.54
0.04
47.40
1
.
3
8
3
.
5
0
0
.
1
2
2
.
6
8
4.00
0
.
7
1
1
5
.
7
5
1
.
9
7
4
"
4.004.00
0
.
5
3
1
.
3
0
1
.
0
0
2
.
7
4
2
6
.
7
5
1
4
.
7
5
22.84
5.00
16.00
7.00
27.00
2
0
.
3
(
S
C
R
E
E
N
A
R
E
A
)
36.28 (SCREEN AREA)
4
2
PX-42XM4 Page 6 of 8
NEC Europe Ltd
PDP Department
42XM4 Installation Guide
42” Plasma Display Rev 1.0
www.neceurope.com
Connections
Located at right side of display
Control Panel
AC Inlet
Power Switch
Ext Speaker Connections
PX-42XM4 Page 7 of 8
NEC Europe Ltd
PDP Department
42XM4 Installation Guide
42” Plasma Display Rev 1.0
www.neceurope.com
Control Codes
Function Code Data
POWER ON 9FH 80H 60H 4EH 00H CDH
OFF 9FH 80H 60H 4FH 00H CEH
INPUT SWITCH VIDEO1 (BNC) DFH 80H 60H 47H 01H 01H 08H
VIDEO2 (RCA) DFH 80H 60H 47H 01H 02H 09H
VIDEO2 (S-Video) DFH 80H 60H 47H 01H 03H 0AH
DVD1/HD1(RCA/Component) DFH 80H 60H 47H 01H 05H 0CH
DVD2/HD2 (5BNC/Component) DFH 80H 60H 47H 01H 06H 0DH
RGB1 (15pin HD) DFH 80H 60H 47H 01H 07H 0EH
RGB2 (5BNC/RGB) DFH 80H 60H 47H 01H 08H 1FH
RGB3 (DVI) DFH 80H 60H 47H 01H 0CH 13H
AUDIO MUTE ON 9FH 80H 60H 3EH 00H BDH
OFF 9FH 80H 60H 3FH 00H BEH
PICTURE MODE NORMAL DFH 80H 60H 0AH 01H 01H CBH
THEAT.1 DFH 80H 60H 0AH 01H 02H CCH
THEAT.2 DFH 80H 60H 0AH 01H 03H CDH
DEFAULT DFH 80H 60H 0AH 01H 04H CEH
BRIGHT DFH 80H 60H 0AH 01H 05H CFH
SCREEN MODE: STADIUM DFH 80H 60H 51H 01H 02H 13H
ZOOM DFH 80H 60H 51H 01H 03H 14H
NORMAL DFH 80H 60H 51H 01H 04H 15H
FULL DFH 80H 60H 51H 01H 05H 16H
2.35:1 DFH 80H 60H 51H 01H 0AH 1BH
AUTO PICTURE ON DFH 80H 60H 7FH 03H 03H 09H 00H 4DH
OFF DFH 80H 60H 7FH 03H 03H 09H 01H 4EH
CINEMA MODE ON DFH 80H 60H C1H 01H 01H 82H
OFF DFH 80H 60H C1H 01H 02H 83H
NOTE: Contact your NEC rep for codes not listed.
NOTE: Use a cross/reverse/null modem cable.
Cable Connection
Communication Protocol:
Interface: RS-232C Parity: Odd
Communication: Asynchronous Stop Bit: 1 bit
Baud Rate: 9600 bps Communication Code: Hex
Data Length: 8 bits
PC Control Connector (D-Sub 9P)
NOTE: If so desired, jumper “Request to send” and “Clear to Send” together on both ends of the cable to simplify cable connection. These
connections are not required. The only connections required are pins 2 (RxD), 3 (TxD) and 5 (GND)
PX-42XM4 Page 8 of 8
/