CAME GARD 4 SERIES Installation guide

Type
Installation guide

CAME GARD 4 SERIES is a reliable automatic barrier suitable for parking facilities or public, residential, or intensive traffic areas with a passage width of up to 3.75 meters and an opening time of 2 to 6 seconds. It features a galvanized or stainless-steel cabinet, a 24V DC gearmotor, and a control panel with safety contacts for anti-shearing protection.

CAME GARD 4 SERIES is a reliable automatic barrier suitable for parking facilities or public, residential, or intensive traffic areas with a passage width of up to 3.75 meters and an opening time of 2 to 6 seconds. It features a galvanized or stainless-steel cabinet, a 24V DC gearmotor, and a control panel with safety contacts for anti-shearing protection.

G4040Z - G4040IZ
SERIES GARD 4
INSTALLATION MANUAL
OPERATOR
FOR STREET BARRIERS
English
EN
119GU55EN
Page 2
2
- Manual code:
119 G U55
119 G U5 5 ver.
1.1
1.1 01/2012 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
Index
Legend of symbols p. 4
Intended use and limits to use p. 4
Intended use p. 4
Limits to use p. 4
Legislative references p. 4
Description p. 4
Technical data p. 5
Parts list p. 5
Installation p. 6
Dimensions p. 6
Preliminary checks p. 6
Tools and materials p. 6
Type of cable and minimum thicknesses p. 7
Standard installation p. 7
Preparing the automation base p. 8
Installing the unit p. 9
Balancing the barrier arm p. 11
Adjusting the limit switches p. 14
Control panel description p. 16
Manual release of the barrier arm p. 16
Main component parts p. 17
Electrical connections p. 17
Adjusting manoeuvring and braking speeds p. 19
Selecting functions p. 20
Adjustments p. 20
Activating the radio command p. 21
Connecting two barriers joined by a single command p. 23
Safety instructions p. 24
Maintenance p. 24
Periodic maintenance p. 24
Extraordinary maintenance p. 26
Dismantling and disposal p. 27
Trouble shooting p. 27
CE Compliance statement p. 28
Page 3
3
-
Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
01/2012
© CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
WARNING!
important safety instructions:
READ THIS PART CAREFULLY!
Premise
The motor must only be used in the way it is intended and for what
it is designed. Any other use is to be considered dangerous. La
CAME cancelli automatici s.p.a. is not liable for any damage due
to improper, errouneous and unreasonable use • Keep these war-
nings together with the installation and users' manual for the au-
tomation system.
Before installing
(check what's there: if the outcome is negative, refrain from conti-
nuing until you are compliant with safety standards.
Check that the part being automated is in proper working order, that
it is balanced and aligned, and that it opens smoothly. Make sure
you have suitable mechanical stops. If the operator will be installed
less than 2.5 m from the floor or from any other access level, check
whether you need additional protections and/ or warnings. With
pedestrian doors framed int o the doors that will be automated, a
system must be in place to block their opening during movement.
Make sure the opening of the automated door leaf does not cause
any trapping situations involving any surrounding fixed parts. Do
not install the operator upside down or on any elements that may
bend. If necessary, add suitable reinforcements at the fastening
points. Do not fit onto door leafs that are installed on a slope, only
on level ground. Check that any watering devices cannot wet the
gearmotor from the bottm upwards.
Installation
Properly demarcate the entire site to prevent any unwanted access
by unauthorised personnel to the working area, especially children
and minors. Be careful when handling operators that weigh more
than 20 kg (see intallation manual). You may have to equip yourself
with safe moving gear. All opening commands (buttons, key-switch
selectors, magnetic readers, and so on) must be installed at le-
ast 1.85 M from the gate's area of movement, or so that they are
unreachable from the outside. Also, the direct commands (button
or touch) must be installed at least 1.5 m high and not reachable
by the public. All "maintained action" commands must be placed
where the moving door leaves and transit areas are completely vi-
sible. If missing, affix a permament tag showing the position of
the release device. Before delivering to the end user, check that
the operator complies with Standard EN 12456 (impact testing),
making sure the operator is properly set and adjusted and that all
safety and protection devices and manual release work properly.
Affix the Warning Signs in places that are clearly visible, where
necessary (such as the gate tag).
Instructions and special recommendations for users
Keep gate-operating are free of any obstacles. Keep the photocells'
range of operation free of vegetation. Do not allow children to play with
the fixed command devices, or in the area of operation of the gate.
Keep the remote control devices (transmitters) away from children.
Check the system frequently, for any anomalies and signs of wear and
tear or damage to the mobile structures, the component parts of the
operator, all fastening points and devices, the cable and any acces-
sible connections. Keep any jointed parts like hinges lubricated and
clean of debris and the guide-sleds free of any friction. Perform fun-
ctional checks to the photocells and sensitive edges every six months.
Ensure proper cleaning of the glass on the photocells (use a slightly
damp cloth); do not use solvents or other chemical products). If repai-
rs or changes to the system settings become necessary, release the
operator do not use it until all safety conditions are restored. Cut the
main power supply before releasing the operator to perform manual
openings.
Check the instructions. It is FORBIDDEN for users to perform ANY
OPERATIONS THAT ARE NOT EXPRESSLY REQUESTED OF SAID
USERS in the manuals. For repairs, changes to the settings and extra-
ordinary maintenance, CALL FOR TECHNICAL ASSISTANCE. Enter any
interventions in the periodic maintenance log.
Special instructions and recommendations for everyone
Keep away from the hinges and any moving mechanical parts. Stay
out of the operating range of the operator while it is moving. Do not
oppose the movement of the operator as this may result in danger. Al-
ways be careful around the dangerous parts, which must be properly
indicated with warning signs and black and yellow stripes. When using
a selector switch or a maintained-action mode command, keep che-
cking that no persons come within the operating range of the moving
parts, until the command is released. The gate may move at any mo-
ment without warning. Always cut off the main electric power supply
before performing any cleaning or maintenance.
Page 4
4
- Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
1.1 01/2012 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
This symbol shows parts which must be read with care.
This symbol means the parts which describe safety issues.
This symbol tells you what to tell the end-user.
GARD 4 is engineered and built by CAME CANCELLI AUTOMATICI S.p.A. in compliance with current safety code.
The cabinet is made of galvanised, epoxy powder-coated 2.5 m thick steel sheeting, or of satinated AISI 304 staniless steel 2 mm thick.
Inside there is a gearmotor and all of the mechanical moving parts. The control panel is housed in the upper dome.
Designed around the anti-shearing dsafety function, it is fi tted with safety contacts in the hatch lock and in the emergency release lock. .
The operators comes in two versions:
001G4040Z - Automatic barrier made of galvanised epoxy poweder-coated galvanised steel with a 24V D.C. powered gearmotor complete
with control panel;
001G4040IZ - automatic barrier made of satinated AISI 304 stainless steel with a 24V D.C. powered gerarmotor complete with control pa-
nel;
The following accessories are complementary to the GARD 4 operator:
001G03750 - Semi-rounded aluminium white-varnished barrier arm, 4 m long complete with transparent bottom cover-strip and anti-
impact profi le1 ;
001G03752 - Rounded alumiium white-varnished barrier arm, 4 m long comlete with transparent botton cover-strip;
001G03753 - Attachment fl ange for rounded barrier-arm;
001G02040 - Balancing spring Ø40 (yellow);
001G04060 - Balancing spring Ø50 (green);
001G06080 - Balancing spring Ø55 (red);
001G03756 - Internal reinforcement for the G03750 semi-rounded barrier;
001G03755DX - Joint for semi-rounded barrier arm for right-hand barriers;
001G03755DX - Joint for semi-rounded barrier arm for left-hand barriers;
002LB38, - Electronic card for connecting three 12V-6Ah batteries ;
The following accessories are optional on the GARD 4 operator;
001G02801 - Flashing dome-light.
001G02802 - Support for applying the DIR photocell onto the cabinet (cannot be used for barriers fi tted with swing skirt and/or swing
rest;
001G03751 - Emergency battery housing support
001G028401 - Luminous cord to signal movement;
001G028 402 - Luminous cord connecting cable;
001G02807 - Fixed support;
001G02808 - Swing rest;
001G02809 - Package of 20 red refl ective adhesive strips;
001G0465 - Swing skirt made of 2 m-long aluminium modules;
WARNINGS!
001G02802 Cannot be used with with barriers with 001G0465 skirt and/or 001G02808 swing leg support
001G02808 For passage widths of up to maximum 3 m.
001G03756 - MUST use on barriers with passage widths exceeding 3 m or with the 03756G3 luminous cord.
MUST use on barriers with passage widths exceeding 2.5 m or with 001G02808 swing leg support or with 001G0465 skirt.
001G02807 For passage width wider than 3.5 m use of the fixed support is mandatory.
001G0465 - 001G02808 Cannot be used together.
Important! Make sure that the command and safety equipment and accessories are CAME originals; this will ensure easy installation and maintenance
of your system.
Passage width is up to 3.75 metres and opening time is between 2 to 6 seconds.
Came Cancelli Automatici employs an ISO 9001:2000 certified quality management system and an ISO 14001 environmental manage-
ment system. Came entirely engineers and manufactures in Italy.
This product is compliant with: see statement of compliance.
Legend of symbols
Intended use and limits to use
Intended use
Limits to use
Legislative references
Description
BARRIER automatic GARD 4 is " for l’ in PARKING FACILITIES or public, in areas residential or in zones intensive.
Every installation and use other than that specified in this manual is forbidden.
#
#
8
CAME
CAME
CAME
CAME
7
1
2
3
4
5
7
12
11
8
9
2
3
4
6
5
13
1
14
10
6
9
10
11
15
Page
5
-
Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
01/2012
© CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
OPERATOR ASSEMBLY UNIT
ACCESSORIES
1)
G03750 - aluminium white-varnished semi-rounded barrier arm L =
4 m.
2)
G03752 - aluminium white-varnished rounded barrier arm L = 4 m.
3)
G02040 - Balancing spring Ø40 (yellow)
4)
G04060 - Balancing spring Ø50 (green)
5)
G06080 - Balancing spring Ø55 (red)
6)
G0465 - Swing skirt
7)
G02802 - Support for DIR photocells
8)
G028401 - Luminous cord
9)
G02807 - Fixed support
10)
G02808
- Swing rest
11)
Red refl ective-strips stickers
12)
G02801 - Flashing dome-light
13)
G03751 - Emergency battery housing support
14)
G03753 - Attachment fl ange for rounded barrier-arm
15)
G03756 – Internal reinforcement for the G03750 semi-rounded
barrier
11 -
BARRIER-ARM ATTACHEMENT
VIEW
INSPECTION HATCH VIEW
GEARMOTOR
Power supply: 230V A.C. 50/60 Hz
Motor power supply: 24V D.C. 50/60 Hz
Assorbimento Max.: 1.3A (230V) / 15A (24V)
Potenza: 300 W
Max. torque: 600 Nm
Reduction ratio: 1/202
Opening interval: 2÷6 S
Duty cycle: intensive
Protection rating: IP54
Peso: 55 kg
Insulation class: I
1) Upper dome
2) Shaft plate
3) Barrier-arm attachment mid-plate
4) Semi-rounded arm-attachment cover
5) Anti-shearing protective cover
6) Galvanised or painted stainless-steel cabinet
7) Inspection hatch
8) Gearmotor
9) Lever arm
10) Limit-switch assembly
11) ZL38 control panel
Technical data
Parts list






MAX

Page
6
- Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
1.1 01/2012 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
Make sure you have all the tools and materials needed to carry out the installation in total safety and in accordance with current regula-
tions. The figure shows some examples of the tools needed by installers.
Before beginning to install, do the following:
• Check that installing the operator does not create any hazardous situations;
Set up a suitable omnipolar cut-off device, with distances greater than 3 mm between contacts, with sectioned
power source;
Check that any connections inside the container (made for continuity purposes of the protective circuit) be fitted with extra insulation
compared to other internal conductive parts;
• Set up proper conduits and electric cable raceways, making sure these are protected from any mechanical damage;
Installation must be carried by skilled, qualified technicians in accordance with current regulations.
Measurements in mm
Installation
Dimensions
Preliminary checks
Tools and materials
2
1
7
3
4
5
6
8
9
10
11
12
13
Page
7
-
Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
01/2012
© CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
N.B. If cables are of a different length than that shown in the table, determine the cable section based on the actual draw and the number
of connected devices and according the what is set forth in the CEI EN 60204-1 code of regulations.
Per i collegamenti che prevedano più carichi sulla stessa linea (sequenziali), il dimensionamento a tabella deve essere riconsiderato sulla
base degli assorbimenti e delle distanze effettivi. When connecting products not featured in this manual, only refer to the literature ac-
companying such products.
1 - GARD unit
2 - Control panel
3 - Aluminium barrier-arm
4 - Red reflective strips
5 - Luminous cord
6 - Motion warning flashing light
7 - Small column for photocells
8 - Photocells
9 - Fixed support
10 -Metal mass detector
11 - Support and DIR PHOTOCELL
12 - Command device (keypad, magnetic key, card, and so on.)
13 - Small column for command device
Connection
Type of
cable
Cable length
1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
Powered by 230 V AC
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1.5 mm
2
3G x 2.5 mm
2
3G x 4 mm
2
Photocell transmitters 2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Photocell receivers 4 x 0.5 mm
2
4 x 0.5 mm
2
4 x 0.5 mm
2
Accessories power source 24 V DC 2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 1 mm
2
Dispositivi di comando e di sicurezza 2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Connecting the antenna RG58 max. 10 m
Metal mass detector (see product literature delivered with product)
Type of cable and minimum thicknesses
Standard installation
R
Page
8
- Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
1.1 01/2012 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
The following illustrations are just examples, in that the space for securing the operator and accessories depends on the overall
measurements. It is up to the installer to choose the most suited solution.
- PLATE.
- Dig a pit for the anchoring base and set up the required
corrugated tubes for the connections coming out of the
junction pit.
N.B. the number of tubes depends on the type of
installation and accessories used.
- Remove any protruding nuts or wahsers, position the cabinet onto the base and fasten
it.
Note: install the cabinet with the inspection door facing an easily accessible direction.
- Fill the pit with cement and sink the anchoring base (that is, the
plate + clamps) making sure the corrugated tubes pass throught
he hole set up on the plate and that they are not fi lled with cement.
The base must be perfectly level, clean and with the bolt threading
completely on the surface.
Wait at least 24 hrs for everything to solidify.
Preparing the automation base
SX
DX
6;
1
0
37 ) )&
)$
';
Page
9
-
Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
01/2012
© CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
- Remove the two top bolts from the upper dome, insert key into
lock and turn counter-clockwise.
- When installing on the right-hand side (DX), you need to invert
the barrier-arm's direction of opening, by doing the following:
- remove spring-hooking pin from the transmission arm (1);
- use key to release the gearmotor;
- turn the transmission arm (2);
- relock the gearmotor;
- Fit the anchoring pin into the hole opposite the initial one (3);
- invert the cables on terminals M and N, FA and FC (4).
- Lift up the dome and remove the cabinet hatch.
- the barrier is set up to be left-
hand (SX) installed.
Installing the unit
,
UNI6954 ø2,9x13
UNI5931 M8x20
UNI5931 M8x12
UNI5931 M8x12
Page
10
10 - Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
1.1 01/2012 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
- Position the mid-plate and arm-attachment cover using just
one (M8x20) screw. Leave the creww loosened to facilitate
subsequent arm insertion.
Attachment plate
Mid plate
Arm-attachment cover
- Insert the arm into the attachment cover and fasten using the
M8x20 and M8x21 screws.
Note: if installing with the G03750 barrier arm, t the G03756
reinforcement.
- Cut the raceway cover profi les to the length
needed to insert them into the barrier arms’
raceway. Procedure to follow on both sides.
Finally fasten the arm end cap.
UNI6954 ø3,9x19
Page
11
11 -
Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
1.1 01/2012
© CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
Simple barrier arm* + anti-impact profile
Simple barrier-arm * + anti-impact profile + luminous cord
Simple barrier-arm* + skirt
Simple barrier-arm* + luminous cord + skirt
Asta semplice* + antiurto + appoggio mobile
Simple barrier-arm* + anit-impact profile + luminous cord + swing-
restb
- Before balancing the barrier-arm, check the table below, to see congruences among the chosen spring, any accessories and passage
width:
- Insert the protective anti-shearing casing onto the arm attachment cover and fasten it using the screws.
*A simple barrier arm is complete with transparent channel cover and endcap.
PASSAGE WIDTH (max. 3.75 m)
SPRING TYPES
G02040 Ø
e spring = 40 mm
G04060 Ø
espring = 50 mm
G06080 Ø
e spring = 55 mm
Passage width (m) 1.5
1.75
2.0
2.25
2.5
2.75
3.0
3.25
3.5 3.75
Balancing the barrier arm
Page
12
12 - Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
01/2012 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
- Release the gearmotor and position the arm vertically, then lock it back
into place.
- Prepare the spring by tightening the ring-bolt below. Thee
screw should then be fi tted onto the lug which is hooked to the
transmission arm.


Page
13
-
Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
01/2012
© CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
- Attach the ring-bolt to the anchoring bracket
release the gearmotor and manually turn the spring to increase or
decrease traction. The barrier arm must stabilise at 45°.
- Fit the counter nut and block the gearmotor back into place.
Note: Check proper working order of the spring:
- with barrier arm in vertical position, the spring is not
under tension.
- with barrier arm in horizontal position, the spring is
loaded.
- C
ARRY OUT THE ELECTRICAL CONNECTIONS ON CONTROL PANEL (SEE
ELECTRICAL CONNECTIONS PARAGRAPH).
a
a
a
a
Page
14
- Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
01/2012 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
- Correct the horizontal (closing) position, in the same way.
N.B.: procedure to carry out after making electrical connections to the control panel.
Close the inspection hatch and power up the system. Activate the arm to check whether it is parallel to the road surface when close and
at about 89° when open.
Warning!The inspection hatch must be closed for opening and closing of the barrier arm to be safe and functional.
- To adjust the vertical (opening) position of the barrier arm, close it, open the inspection hatch and turn the screw clockwise (to
increase the the barrier-arm travel, or, counterclockwise to decrease it. n.
Note: before stopping completely the barrier-arm goes through a
slowing down phase thanks to a cam that triggers the slow-down
microswich. the microswitch is set at maximum advance. If you
wish to delay the slowing-down pahse, loosen the screws of the
o micro-switch ledge screws p, and position them outwards, see
drawing.
Adjusting the limit switches
:,
Page
15
15 -
Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
01/2012
© CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
- After checking the barrier-arm's opening and closing settings, defi nitively
tighten the locking couter-nuts under the bolts.
- ...replace the inspection hatch and upper dome.
- Once all of the mechanical and electrical installation operations are completed fi t the
cover over the control panel, ...
- Turn the key clockwise and lock the protective dome using
the supplied Ø3.9x13 bolts.
Page
16
- Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
1.1 01/2012 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
Engineered and built entirely by Came Cancelli Automatici S.p.A.
The control panel is powered at 230V a.c., with 50/60Hz of maxi-
mum frequency.
The command devices and accessories are powered by 24V.
Warning! The accessories must not exceed 40 W overall.
The control unit is un dispositivo amperometrico che controlla co-
stantemente il valore della spinta del motore..
When the barrier arm runs into an obstacle, the amperometric
sensor detects an overload in the thrust and acts on the move-
ment:
- when opening: by stopping the arm;
- when closing: the barrier arm inverts its direction of travel until
it fully opens, triggering the automatic closing.
Warning! after three consecutive inversions, the barrier-arm stay
upright, and excluded the automatic closing: to close, use the
transmitter of closing button.
All connections are protected by quick fuses, see table.
The card provides and controls the following functions:
- automatic closing after an opening command;
- immediate closing;
- pre-fl ashing movement indicator;
- obstacle detection when barrier arm is stopped in any position;
- Slave function;
-increased braking action of the barrier arm.
The available command modes are:
- opening/closing;
-opening/closing with maintained action;
- opening;
- total stop.
Special trimmers regulate:
- the working time for automatic closing;
- the amperometric device's detection sensitivity;
Optional accessories:
- fl ashing cupola and luminous cord.
- barrier-arm open light, signals that the barrier-arm is open -
switches o at end of closing working-time;
- LB38 card, when using batteries as a power source during
blackouts. When the electric power is restored, it also recharges
the batteries (see the technical literatue).
WARNING: before acting inside the equipment, cut the main power
supply and disconnect the batteries (if they are connected).
WARNING! The release
action may result in danger
for the user, when, for wha-
tever reason - the arm is
improperly fixed to the pin
during mounting, the arm
is broken or cracked during
an accident, etc.- the
tension springs no longer
provide balance! This may
result in sudden rotating
movements of arm
attachment and/or of the
arm itself.
- Insert the key into the lock and turn it clockwise. Manually lift the barrier arm and re-lock it by turning the key
counter-clockwise.
TECHNICAL DATA
line voltage 230 V - 50/60 Hz
Maximum allowed power load 400 W
power draw when idle 25 W
max power
for 24 V accessories
40 W
circuit insulation class II
container material ABS
FUSE TABLE
to protect: fuses for:
Motor/s 10 A-F
Electronic board (line) 3.15 A-F
Accessories 2 A-F
Command devices
(control unit)
630 mA-F
Manual release of the barrier arm
Control panel description
#
/
-
2ALLENTAM6ELOCITÍ
-AX-AX -ED -IN -IN
$)3
/.

.
-
04 & &#
&!
.
,
,
,4
%


#
#
'.$4828
9
8
710
11
1
2
12 133
6
5
4
14
18
.
-
04 & &#
&!
COM
NC
NC
COM
16
15
17
Page
17
-
Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
01/2012
© CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
1- Accessories fuse
2 - Line fuse
3 - Line control unit
4 - Motor fuse
5 - Acessories terminals
6 - Radio-requency card socket (see table on p. 19)
7 - Trimmer SENS: adjusting amperometric sensitivity
8 - Trimmer TCA: adjusting automatic closing time
9 - Functions selection Dip switch"
10 - Code memorising button
11 - Warning LED for radio code/automatic closing
12 - Adjusting connectors for speed and slow-downs
13 - Connectors for connecting the (LB38) battery charger
14 - Selection jumper for command type for button on 2-7
15 - Transformer
16 - Power source terminals
17 - Motor terminals
18 - Limit switch terminals
Motor 24V (d.c.)
Gearmotor, limit switch
Closing microswitch
Orange
Orange
White
Red
Blue
Brown
Opening micro-
switch
Description of already required wiring connections. " For right-hand installation, see pge 7.
White
Red
Black
Brown
Blue
Brown
Main component parts
Electrical connections
.
,
%


#
#
+
-
%


#
#
/.

%


#
#
}
}
%


#
#
RX
TX
Page
18
- Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
1.1 01/2012 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
Terminals for powering accessories:
- normally at 24V A.C;
- when emergency batteries are operating;
Overall allowed power: 40 W
Power supply
Power supply 230V (a..C.)Frequency 50/60 Hz
Eyelet terminal with screw and
washer for ground connection
Command button (N.O. contact ) - Barrier-arm opening
and closing command. The barrier opens or inverts its
movement depending on what is selected on Dip switch
2.)
Check position of jumper (n 14, page 15) as shown in
gure.
Command devices
Closing button (N.O. contact) - Barrier-arm closing
command. This command is obligatory with the
"maintained action" function.
Position jumper as shown.
Immediate closing (N.C.) contact
Automatic closing of barrier arm after obstacle passes
within operating range of safety devices
if unused, set Dip switch 8 to ON.
DIR photocells
Stop button (N.C. contact) - Button to stop barrier arm Excludes automatic closing. To resu-
me movement press the command button or trasmitter key.
if unused, set Dip switch 9 to ON.
Opening button (N.O. contact) - Barrier-arm opening command.
%


#
#
TX
RX
.
,
,4
#
#
#
/
-
2ALLENTAM6ELOCITÍ
-AX-AX -ED -IN -IN
$)3
!"
%


#
#
Page
19
19 -
Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
01/2012
© CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
(N.C.) contact. di riapertura durante la chiusur
- Input for safety devices like photocells, compliant with
law EN 12978. While the gate is closing, opening the
contact will invert movement until it is fully openend.
If unused, short-circuit contact 2-C1.
DIR photocells
Safety devices
Per regolare la velocità di
opening (°) e chiusura, sposta-
re il faston del trasformatore
indicato con "A" su
[Speed] -> [Min.]/[Max..].
To ajust the slow-downs
,
move faston " B" to
[Slow down.] -> [Min/Max.].
Black
White
Red
Flashing light for open barrier Contact rated for: 24 V - 3 W Max.)
- Signals that barrier-arm is raised, and switches of when the barrier-arm is
lowered.
Flashing dome light and/ir luminous cord (Contact rating: 24 V - 32 W Max.) - Flashes while door
opens and closes.
Warning devices
[Min.] = minimum
[Med.] = medium
[Max.] = maximum
Adjusting manoeuvring and braking speeds
/.

.
-
04 & &#
&!
.
,
,
,4
%


#
#
'.$4828
ON
OFF

/.
/.

.
-
04 & &#
&!
.
,
,
,4
%


#
#
'.$4828
3%.3
!#4
Page
20
- Manual code:
119 G U5 5
119 G U5 5 ver.
1.1
01/2012 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
1 ON - Automatic closing - The automatic closing timer activates at the closing endpoint. The preset time is adjustabel, but it's in
any case subject to any safety device intervention and does not activated after a Total Stop or in case of power failure (1 OFF -
deactivated);
2 OFF - Function "opens-closes" with Button and Radio transmitter (with Radiofrequency card insert.).
2 ON - Function "only" with Button and Radio transmitter (with Radiofrequency card insert.).
3 ON - 24 V output on contact (10-E) barrier arm in movement and in closed position;
3 OFF- 24 V output on contact (10-E) barrier arm in movement;
4 ON - Maintained action - the barrier works by keeping the button pressed, a button 2-3 for opening, a button 2-7 for closing (position
jumper n. 14 as shown in fi gure 16).
5 ON - Pre-fl ashing when opening and closing - After either an opening or closing command, the fl ashing light and/or luminous cord
conencted on [10-E], ash/es for 5 secodns before cycle start.
6 ON - Obstacle detection - With motor idle (barrier arm closed, open or after a total stop command), it prevents any movement if the
safety devices (e.g. photocells) detect an obstacle.
7 ON - "Slave" function - To be activated when having two combined barriers (see the Connecting two combined barriers
paragraph);
8 OFF - Immediate closing dell’asta ( - Automatic closing of barrier arm after obstacle passes within operating range of safety devices.
Insert safety device on [2-C5]; if unused, set DIP switch to ON.
9 OFF - Total stop - - This function stops the door and then excludes any automatic closing cycle; use either the buttons or transmitter
to resume movement. Connect button on [1-2]; if unused, set DIP switch to ON .
10 ON - Braking action - Increase braking action of the closing barrier arm (10 OFF - deactivated)
LIST TRIMMER Adjustments:
- «A.C.T Adjusts opening waiting time. The gate closes automatically once this time-frame has elapsed. The waiting time may be
adjusted from 1 second to 120 seconds.
- «SENS» Adustes the amperometric sensitivity which controls the force developed by the motor during movement; if the force
exceeds the adjusted level, the system intervenes and inverts the direction of travel.
Default setting
Adjustments
Selecting functions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

CAME GARD 4 SERIES Installation guide

Type
Installation guide

CAME GARD 4 SERIES is a reliable automatic barrier suitable for parking facilities or public, residential, or intensive traffic areas with a passage width of up to 3.75 meters and an opening time of 2 to 6 seconds. It features a galvanized or stainless-steel cabinet, a 24V DC gearmotor, and a control panel with safety contacts for anti-shearing protection.