Onyx MedPC-5300 User manual

Type
User manual
Medical PC MedPC- 5300
MedPC-5300
Fanless Medical Grade Box PC
Atom D525 Processor
MedPC-5300 Manual 1
st
Edition
July. 2012
Medical PC MedPC- 5300
Copyright Notice
This document is copyrighted, 2012. All rights are reserved. The
original manufacturer reserves the right to make improvements to
the products described in this manual at any time without notice.
No part of this manual may be reproduced, copied, translated, or
transmitted in any form or by any means without the prior written
permission of the original manufacturer. Information provided in
this manual is intended to be accurate and reliable. However, the
original manufacturer assumes no responsibility for its use, nor
for any infringements upon the rights of third parties, which may
result from its use.
The material in this document is for product information only and
is subject to change without notice. While reasonable efforts have
been made in the preparation of this document to assure its
accuracy, ONYX Healthcare Inc., assumes no liabilities resulting
from errors or omissions in this document, or from the use of the
information contained herein.
ONYX Healthcare Inc. reserves the right to make changes in the
product design without notice to its users.
Medical PC MedPC- 5300
Acknowledgments
AMD are registered trademarks of AMD Corporation.
IBM, PC/AT, PS/2 are trademarks of International Business
Machines Corporation.
Microsoft
®
Windows is a registered trademark of Microsoft
®
Corporation.
RTL is a trademark of Realtek Semi-Conductor Co., Ltd.
C&T is a trademark of Chips and Technologies, Inc.
UMC is a trademark of United Microelectronics Corporation.
ITE is a trademark of Integrated Technology Express, Inc.
All other product names or trademarks are properties of
their respective owners.
Medical PC MedPC- 5300
Packing List
Before you begin installing your Bedside Terminal, please make
sure that the following items have been shipped:
MedPC-5300 BoxPC
Screws bag x 1 (HDD screw x 4)
Rubber foot x 1
Utility CD-ROM (Please insert the MedPC-5300 CD-ROM into
external CD-ROM drive.) which Contains User’s Manual (in
PDF format), Drivers and Utilities
If any of these items are missing or damaged, you should contact
your distributor or sales representative immediately.
Headquarters
Onyx Healthcare Inc.
2F, No.135, Lane 235, Pao-Chiao Rd.,
Hsin-Tien City, Taipei 231, Taiwan, R.O.C.
TEL: +886-2-8919-2188
FAX: +886-2-8919-1699
E-mail: sales@onyx-healthcare.com
http://www.onyx-healthcare.com
Medical PC MedPC- 5300
Worldwide Offices:
Onyx Healthcare, USA Inc.
2663 Saturn street, Brea, CA 92821, USA
Tel : +1-714-996-1800
Fax: +1-714-996-1811
Onyx Healthcare EUROPE B.V.
Ekkersrijt 4002, 5692 DA Son, The Netherlands
Tel : +31-(0)499-462020
Fax: +31-(0)499-462010
Onyx Healthcare Technology GmbH
An der Trift65d
63303 Dreieich , Germany
TEL: +49-(0)61033-7479-00
Fax : +49-(0)61033-7479-49
Onyx Healthcare (SU ZHOU) INC.
Room 12, 2F, Building B, No.5 Xing Han Street, Suzhou Industrial
Park, Jiang Su Province, China
Tel: +86-512-67625700
Fax: +86-512-67617337
Email: cnsales@onyx-healthcare.com
Medical PC MedPC- 5300
Onyx Healthcare Singapore PTE LTD
57 Genting Lane, #07-00, Singapore 349564
Tel: +65-67498749
Fax +65-67461595
Email: sgsales@onyx-healthcare.com
Medical PC MedPC- 5300
Safety & Warranty
1. Read these safety instructions carefully.
2. Keep this user's manual for later reference.
3. Disconnect this equipment from any AC outlet before cleaning. Do not
use liquid or spray detergents for cleaning. Use a damp cloth.
4. For pluggable equipment, the power outlet must be installed near the
equipment and must be easily accessible.
5. Keep this equipment away from humidity.
6. Put this equipment on a reliable surface during installation. Dropping it
or letting it fall could cause damage.
7. The openings on the enclosure are for air convection. Protect the
equipment from overheating. DO NOT COVER THE OPENINGS.
8. Make sure the voltage of the power source is correct before
connecting the equipment to the power outlet.
9. Position the power cord so that people cannot step on it. Do not place
anything over the power cord.
10. All cautions and warnings on the equipment should be noted.
11. If the equipment is not used for a long time, disconnect it from the
power source to avoid damage by transient over-voltage.
12. Never pour any liquid into an opening. This could cause fire or
electrical shock.
13. Never open the equipment. For safety reasons, only qualified service
personnel should open the equipment.
Medical PC MedPC- 5300
14.
If any of the following situations arises, get the equipment
checked by service personnel:
a. The power cord or plug is damaged.
b. Liquid has penetrated into the equipment.
c. The equipment has been exposed to moisture.
d. The equipment does not work well, or you cannot get it to
work according to the users manual.
e. The equipment has been dropped and damaged.
f. The equipment has obvious signs of breakage.
15.
DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED
ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS
BELOW -20° C (-4°F) OR ABOVE 60° C (140° F). IT MAY DAMAGE
THE EQUIPMENT.
16.
External equipment intended for connection to signal
input/output or other connectors, shall comply with relevant UL /
IEC standard (e.g. UL 1950 for IT equipment and UL 60601-1 /
IEC 60601 series for systems shall comply with the standard
IEC 60601-1-1, Safety requirements for medical electrical systems.
Equipment not complying with UL 60601-1 shall be kept outside
environment, as defined in the standard.
Caution:
It may cause the danger of explosion if battery is incorrectly
replaced. Replace only with same or equivalent type recommended
by the manufacturer.
Medical PC MedPC- 5300
Classification
1. Degree of production against electric shock: not classified
2. Equipment not suitable for use in the presence of a flammable
anesthetic mixture with air or with oxygen or nitrous oxide.
3. Mode of operation: Continuous
4. Type of protection against electric shock: Class I equipment
5. Class I: No Applied part, No AP / APG
Medical PC MedPC- 5300
FCC
This device complies with Part 15 FCC
Rules. Operation is subject to the
following two conditions: (1) this device
may not cause harmful interference, and (2)
this device must accept any interference
received including interference that may
cause undesired operation.
Medical PC MedPC- 5300
UL Module Description
MedPC-1200 AC modules are developed to
suitable for the Classification Mark requirement
Medical PC MedPC- 5300
Safety Symbol Description
The following safety symbols are the further explanations for your
reference.
Medical equipment with respect to electric
shock, fire and mechanical hazards only in
accordance with UL 60601-1, and
CAN/CSA C22.2 NO. 601.1
Attention, consult ACCOMPANYING
DOCUMENTS.
Ground wire
Protective Ground wire.
Medical equipment with respect to electric
shock, fire and mechanical hazards
only in
accordance with UL 60601-1, and
CAN/CSA C22.2 NO. 601.1
Medical PC MedPC- 5300
Contents
Chapter 1 General Information
1.1 Introduction ...................................................................... 1-2
1.2 Feature ............................................................................. 1-3
1.3 Specification ..................................................................... 1-4
1.4 Dimension ........................................................................ 1-6
Chapter 2 Hardware Introduction
2.1 Safety Precautions ........................................................... 2-2
2.2 A Quick Tour of MedPC5300………..……………………..2-2
2.3 System Memory ............................................................. 2-3
2.4 Mini PCI Express………………..………………...............2-8
2.5 Clear CMoS9CLTRC1.………………………………..……2-8
2.6 Rear Panel Connectors ……………………………..……2-10
2.7 Wallmount kit Installation………………………………….2-12
Chapter 3 BIOS Setup
3.1 BIOS Setup…………………………………………………..3-1
Chapter 4 Driver Installation
4.1 Installation ........................................................................ 4-3
Appendix A I/O Information
A.1 I/O Address Map ............................................................. A-2
A.2 Memory Address Map ..................................................... A-3
A.3 IRQ Mapping Chart ....................................................... A-5
Medical PC MedPC- 5300
Appendix B Miscellanea
B.1 General Cleaning Tips .................................................... B-2
B.2 Cleaning Tools ................................................................ B-3
B.3 Scrap Computer Recycling ........................................... B-5
Medical PC MedPC- 5300
Chapter 1 General Information 1-1
General
Information
Chapter
1
Medical PC MedPC- 5300
Chapter 1 General Information 1-2
1.1 Introduction
The MedPC-5300 is a Medical grade embedded PC with Intel Atom
D525 processor-based computer. It is a PC-based embedded
system with IPX1 water proof system architecture and “Fan-less
solution; integrated multimedia functions make them the perfect
platforms to build comprehensive computing applications.
The MedPC-5300 series is the all the features of a powerful
computer into a small chassis. The MedPC-5300 has
designed with
the next-generation NVIDIA® ION™ graphics to support richer
multi-media. 2 type video interface to support Full HD 1920 x 1080
resolution. It supports 2.5” Hard Disk Drive bay and one Mini card
for WLAN expansion. Moreover, they feature flexible I/O ports, such
as 5 USB 2.0, 2 RS-232, Single Giga LAN RJ-45 connector, one
VGA, one digital video port, one set audio (one Line Out, one MIC
In and Line in).
Convenient operation, fanless, compact size, low power
consumption and highly integrated multimedia system let you to
focus on healthcare utility, interactive information displays,
automation control systems, general desktop usage, multimedia
recreation, and other medical requirements.
Medical PC MedPC- 5300
Chapter 1 General Information 1-3
1.2 Feature
MedPC-5300
High Performance Intel Dual core D525 1.8GHz Processor
Multiple display output support versatile dual display function
Supports Mini card for WLAN(option)
System chassis of easy clean design (no airhole)
Top cover with IPX1 water proof protection
Nvidia GT218 graphic engine inside
Guarantee 5 years life time
Isolated I/O interface (Optional)
EN/UL 60601-1 & CE/FCC Class B
Medical PC MedPC- 5300
Chapter 1 General Information 1-4
1.3 Specification
Main Specifications
CPU Intel Atom D525 DC 1.8GHz Processor
System Memory
DDR3 SODIMM x 2 204 pin supports DDRIII 1066/1333, Max. 8GB
Chipset Intel ICH8M
Expansion Mini Card x1
Storage Disk
Drive
2.5” SATA Hard Disk/SSD Drive bay x1, support SATA 3.0(6Gb/s)
Graphic Specifications
Chipset
NVIDIA GT218, Onboard DDR3 512MB Memory
Resolution VGA x 1 supports up to 2048 x 1536 (@85Hz); Digital output
interface x 1, support 1920 x 1080
Audio Mic-in, Line-in, Line-out, 3 Phone jacks
USB USB 2.0 x 4, USB 2.0 x 1 with isolation(4KV)
Serial Port RS232 x 1, USB x 1 with isolation(4KV)
Ethernet GbE LAN x 1 by RJ-45
KB/MB 1 PS/2 for keyboard and mouse
Mechanical and Environmental
Power Requirement DC12V power input
Operating
Temperature
0˚C to 40˚C (32˚F~104˚F)
Storage Temperature -20˚C to 60˚C (-4˚F ~140˚F)
Mounting Desktop
Medical PC MedPC- 5300
Chapter 1 General Information 1-5
Net Wet 5.6kg
EMC CE/FCC Class B
Medical PC MedPC- 5300
Chapter 1 General Information 1-6
1.4 Dimension
MedPC-5300
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53

Onyx MedPC-5300 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI