2-3
PRODUCT DATA SHEET
Revision 0
Model Indoor Unit FLO 12 N
Model Outdoor Unit GC 12 N (ONG-12)
Installation Method of Pipe Flared
Characteristics Units Cooling Only Cooling Heating
Capacity
(1)
Btu/hr 12390 12390 13650
kW 3.63 3.63 4.0
Power input
(1)
kW 1.115 1.115 1.14
EER (Cooling) or COP(Heating)
(1)
W/W 3.26 3.26 3.51
Energy efficiency class
A
AB
Power supply V/Ph/Hz 220-240V/Single/50Hz
Rated current A 5.0 5.0 5.1
Starting current A 25
Circuit breaker rating A 15
INDOOR
Fan type & quantity Crossflow x 1
Fan speeds H/M/L RPM 1230/1080/930
Air flow
(2)
H/M/L m3/hr 635/550/450
External static pressure Min-Max Pa 0
Sound power level
(3)
H/M/L dB(A) 55/53/49
Sound pressure level
(4)
H/M/L dB(A) 43/39/35
Moisture removal l/hr 1.3
Condenstate drain tube I.D mm 16
Dimensions WxHxD mm 810x190x285
Weight kg 11.5
Package dimensions WxHxD mm 885x360x285
Packaged weight kg 13.5
Units per pallet units 32
Stacking height units 8 levels
OUTDOOR
Refrigerant control Capillary tube
Compressor type,model Rotary,PA145X2C-4FT
Fan type & quantity Propeller(direct) x 1
Fan speeds H/L RPM 810
Air flow H/L m3/hr 1850
Sound power level H/L dB(A) 62 64
Sound pressure level(4) H/L dB(A) 52 53
Dimensions WxHxD mm 795x290x610
Weight kg 35 36
Package dimensions WxHxD mm 945x395x655
Packaged weight kg 39 40
Units per pallet Units 9
Stacking height units 3 levels
Refrigerant type R410A
Refrigerant chargless distance kg/m 1.15kg/7.5m 1.15kg/7.5m
Additional charge per 1 meter g/m 12
Connections between
units
Liquid line In.(mm) 1/4”(6.35)
Suction line In.(mm) 3/8”(9.53)
Max.tubing length m. Max.15
Max.height
difference
m. Max.7
Operation control type Remote control
Heating elements (Option) kW 0.3
Others
(1)
Rating conditions in accordance with ISO 5151, ISO 13253 (for ducted units) and EN 14511.
(2)
Airflow in ducted units; at nominal external static pressure.
(3)
Sound power in ducted units is measured at air discharge.
(4)
Sound pressure level measured at 1 meter distance from unit.