Pulsar PG1202S Owner's manual

Category
Power generators
Type
Owner's manual
1200 WATT GENERATOR
Table of Contents
2
egaPcipoT
Table of Contents
Safety Information
Specifications
Components
Starting the Engine
Stopping the Engine
Resetting Breaker Button
Maintenance
Storage
Statement
Trouble Shooting
Generator Theory Diagram
Limited Warranty
Parts List
2
3
4
5
6
6
6
6
7
7
8
9
10
12
1200 WATT GENERATOR
Safety Information
3
Never operate the engine in an enclosed area All gasoline engines produce carbon monoxide gas
while running.Breathing exhaust fumes can kill.Operate the engine in a well-ventilated area only.
Extract from CPSC Document#5008 on Carbon Monoxide
The U.S.Consumer Product Safety Commission CPSC has issued the following warning regarding
carbon monoxide poisoning
- Do not use portable heaters or lanterns while sleeping in enclosed areas such as tents campers
and other vehicles.This is especially important at high altitudes where the risk of carbon monoxide
poisoning is increased.
- Know the symptoms of carbon monoxide poisoning headache dizziness weakness nausea
vomiting sleepiness and confusion.Carbon monoxide reduces the blood’s ability to carry oxygen.
Low blood oxygen levels can result in loss of consciousness and death
- See a doctor if you or a member of your family develops cold or flu like symptoms.
Carbon monoxide poisoning can easily be mistaken for a cold or flu and is often detected too late.
- Alcohol consumption and drug use increase the effects of carbon monoxide poisoning.
- Carbon monoxide is especially toxic to mother and child during pregnancy infants the elderly.
Smokers and people with blood or circulatory system problems such as anemia or heart disease.
Fuel Is Highly Flammable
DO NOT refuel while engine is running.
DO NOT refuel near sparks or open flame.
DO NOT smoke while refueling.
ALWAYS allow the engine and muffler to cool before refueling.
Refuel ONLY in well-ventilated area.
DO NOT over-fill gas tank.
Engine And Muffler Get Very Hot
Keep flammable materials at least 3 feet from generator.
When in use place generator in an area where children are not likely to touch it.
Electric Shock Hazard
DO NOT operate in rain or snow or next to body of water.
DO NOT touch with wet hands.
Be sure to USE GROUNDED PLUGS with the generator.
DO NOT connect generator to commercial power outlets.
CAUTION
PLEASE READ AND UNDERSTAND THIS MANUAL
COMPLETELY,BEFORE OPERATING THIS GENERATOR.
1200 WATT GENERATOR
Specifications
4
DIMENSIONS
Length
Width
Height
Weight
ENGINE
Type
Fuel
Oil
Gasoline and oil mixing ratio
Displacement
Starting System
Driving System
Spark Plug
Governor
Cooling System
Stroke
Carburetor Type
Air Cleaner Type
Compression Rate
Decibel Ratio
Rated Output
Fuel Tank Capacity
GENERATOR
AC Output Rating
Frequency
AC Current
Rated Output, Continuous
DC Output Rating
DC Current
Power Factor
Steady State Voltage Range
Steady State Frequency Range
Voltage Waveform Twist Rate
16 in.
15 in.
14 in.
39.68 lbs
Air cooled 2-stroke
Two-stroke lubricatioin
30 : 1
72 cc
Recoil ( Electronic Ignition )
Direct Coupling, Taper Fit
F6TC/LD
Mechanica ( Adjustable )
Forced Air
Two Stroke
P15-3
Sponge Element
6
80db @ 3.3 ft / 65db @ 24 ft
72cc @ 3600rpm
1.1 Gal.
Nonleaded gasoline with a minimum of 90% octane
120 Volts
60 Hz
7 Amps
900 Watts
12 Volts
8.3 Amps
Cos = 1
+/- 15%
Less than 7%
Less than 25%
1200 WATT GENERATOR
Generator Components
5
1. Handle
2. Fuel Cap
3. Fuel Tank
4. Fuel Shut-off
5. Recoil Starter
6. Engine On-Off Switch
7. Throttle Lever
8. Air Cleaner
9. Control Panel
10. Generator
11. Muffler
12. Cylinder
13. Spark Plug
1200 WATT GENERATOR
6
STARTING THE ENGINE
1. Disconnect all electric appliances from generator before starting.
2. Turn fuel shut-off lever to “ON”.
3. Move Choke lever all the way to the left.
4. Turn engine switch to “ON” position.
5. Pull recoil starter cord slowly until engaged,then pull briskly to start.
6. Once engine has started,move choke lever all the way back to the right.
CONNECTING ELECTRICAL APPLIANCES
Always allow engine to warm up before connecting any electrical load to the generator.
STOPPING ENGINE
1. Turn off all appliances,the disconnect them from the generator.
2. Turn engine Switch to “STOP” position.
3. Turn fuel shut-off lever to “OFF”.
4. Allow engine to cool before attempting to move the generator or to refuel.
RESETTING BREAKER BUTTONS
If reset rips,disconnect all external electrical appliances before pushing the reset button.
After reconnecting the external electrical appliance, if reset continues to trip that indicates
that the electrical lead connected to the generator from one or more of the appliances may
have a short circuit. In that event, discontinue use of that item until it has been checked
and/or repaired by a qualified technician.
PERIODIC MAINTENANCE
Service intervals
Clean air filter after every 150 hours of run time.(If use inf very dusty conditions,clean air
filter after every 10 hours of run time)
1. Remove foam filter and wash in mild detergent or dish washing liquid
2. Rinse thoroughly,than squeeze out excess water.
3. Allow to thoroughly dry at room temperature.
4. Pour a small amount of gasoline in filter element,then squeeze out any excess gasoline.
5. Replace filter.
Clean spark plug every 50 hours of run time.
1. Remove spark plug and clean electrode with wire brush.
2. Reset gap to .028-.031 in.(.7-.8mm)
1200 WATT GENERATOR
7
Clean fuel filter every 150 hours of run time.
1. Remove fuel filter from inside fuel tank.
2. Clean with solvent.
3. Wipe dry.
4. Insert filter back in fuel tank.
STORAGE
If the generator will not be used for more than one month,follw the following procedures:
1. Drain all fuel from engine(including fuel tank,fuel cock,and carburetor).
2. Shake tank and drain excess oil.
3. Remove spark plug and pour approximately one (1) tablespoon of motor oil into spark
plug hole.
4. Replace spark plug.
5. With ignition switch in “OFF” position,pull starter cord several times until you feel piston is
in its compression stroke. (resistance will increase).
6. Cover generator and store in dry, well-ventilated,place.
STATEMENT
1. For non-handheld engines:The emissions compliance period referred to on the Emissions
Compliance label indicates the number of operating hours for which the engine has been
shown to meet Federal emission requirements.For engines less than 66 cc,
Category C=55 hours,B=125 hours,and A=300 hours. For engines equal to or greater than
66 cc but less than 225 cc displacement,Category C=125 hours,B=250 hours,
and A=500 hours.For engines of 225 cc or more,Category C=250 cc or more,
Category C=250 hours,B=500 hours,and A=1000 hours.
2. For handheld engines:The Emissions Compliance Period referred to on the Emissions
Compliance label indicates the number of operating hours for which the engine has been
shown to meet Federal emission requirements.Category C=50 hours,B=125 hours,
and A=300 hours.
1200 WATT GENERATOR
GENERATOR TROUBLE SHOOTING
8
GENERATOR TROUBLE SHOOTING
ENGINE GENERATOR
Loose spark
plug
Loose cylinder
head bolt
Tighten plug
Tighten bolt
Sufficient compression
Fuel systems cause
Electric systems cause
No fuel supplied
Improper Proper spark
Engine won’t start Engine run erratically Indicator Light on
NO AC Output
Indicator Light off
NO AC Output
Output Power Availa.
Abnormality Exists
Tripped Circuit
Breaker
Poor Connection of
Faulty Lead
Broken
Receptacle
Faulty Generator
Engine RPM set
too High or Low
Insufficient
compression
Check and Repair
Reset
Consult Dealer
Consult Dealer
No load for 60Hz set
No load for 50Hz set
Insufficient pulling
speed for starting rope
Foreign matter
in fuel tank
Fuel shut-off
not open
Spark plug dirty with
carbon or wet with fuel
Damaged spark
plug
Faulty magneto Improper adjustment
of carburetor
Pull rope sharply Clean tank Open Valve Remove carbon or
wipe up spark plug
Replace spark plug Consult dealer Consult dealer
1200 WATT GENERATOR
GENERATOR THEORY DIAGRAM
9
1200 WATT GENERATOR
Limited Warranty
10
Pulsar Products, Inc. warrants to the original purchaser who uses the product in a consumer
application (personal, residential or household usage) that all products covered under this
warranty are free from defects in material and workmanship for one year from the date of
purchase. All products covered by this limited warranty which are used in commercial
applications (i.e. income producing) are warranted to be free of defects in material and
workmanship for 90 days from the date of original purchase. Products covered under this
warranty include air compressors, air tools, service parts, pressure washers and generators.
Pulsar Products, Inc. will repair or replace at Pulsar Products, Inc. sole option, products or
components which have failed within the warranty period. Service will be scheduled
according to the normal work flow and business hours at the service center location, and
the availability of replacement parts. All decisions of
Pulsar Products, Inc. with regard to this
limited warranty shall be final. This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state.
RESPONSIBILITY OF ORIGINAL PURCHASER (Initial User):
To process a warranty claim on this product, DO NOT return item to the retailer. The
product must be evaluated by an Authorized Warranty Service Center. For the location of
the nearest Authorized Warranty Service Center contact the retailer or place of purchase.
Retain original cash register sales receipt as proof of purchase for warranty work.
Use reasonable care in the operation and maintenance of the product as described in the
Owner’s Manual(s).
Deliver or ship the product to the nearest Authorized Warranty Service Center. Freight
costs, if any, must be paid by the purchaser.
Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation.
Contact the nearest Authorized Warranty Service Center that provides on-site service calls
for service call arrangements.
If the purchaser does not receive satisfactory results from the Authorized Warranty Service
Center, the purchaser should contact Pulsar Products, Inc..
1200 WATT GENERATOR
Limited Warranty (cont’d)
11
THIS WARRANTY DOES NOT COVER:
Merchandise sold as reconditioned, used as rental equipment, or floor or display
models.
Merchandise that has become damaged or inoperative because of ordinary wear,
misuse, cold, heat, rain, excessive humidity, freeze damage, use of improper
chemicals, negligence, accident, failure to operate the product in accordance
with the instructions provided in the Owner’s Manual(s) supplied with the
product, improper maintenance, the use of accessories or attachments not
recommended by Pulsar Products, Inc. , or unauthorized repair or alterations.
Repair and transportation costs of merchandise determined not to be defective.
Costs associated with assembly, required oil, adjustments or other installation and
start-up costs.
Expendable parts or accessories supplied with the product which are expected to
become inoperative or unusable after a reasonable period of use.
Merchandise sold by Pulsar Products, Inc. which has been manufactured by and
identified as the product of another company, such as gasoline engines. The
product manufacturer's warranty, if any, will apply.
ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR
EXPENSE THAT MAY RESULT FROM ANY DEFECTS, FAILURE OR
MALFUNCTION OF THE PRODUCT IS NOT COVERED BY THIS
WARRANTY. Some states do not allow the exclusion, so it may not apply to you.
IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR
FROM THE DATE OF ORIGINAL PURCHASE. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitations may not apply.
1200 WATT GENERATOR
Parts List
12
PG1202S-A-01
PG1202S-A-02
PG1202S-A-03
PG1202S-A-04
PG1202S-A-05
PG1202S-A-06
PG1202S-A-07
PG1202S-A-08
PG1202S-A-09
PG1202S-A-10
Parts No. Description
(M6 X 110)
(M6 X 105)
1200 WATT GENERATOR
13
PG1202S-B-01
PG1202S-B-02
PG1202S-B-03
PG1202S-B-04
PG1202S-B-05
PG1202S-B-06
PG1202S-B-07
PG1202S-B-09
PG1202S-B-10
PG1202S-B-08
(M6 X 45)
1200 WATT GENERATOR
14
PG1202S-C-01
PG1202S-C-02
PG1202S-C-03
PG1202S-C-04
PG1202S-C-05
PG1202S-C-06
PG1202S-C-07
1200 WATT GENERATOR
15
PG1202S-D-01
PG1202S-D-02
PG1202S-D-03
PG1202S-D-04
PG1202S-D-05
PG1202S-D-06
PG1202S-D-07
PG1202S-D-09
PG1202S-D-10
PG1202S-D-08
1200 WATT GENERATOR
16
PG1202S-E-01
PG1202S-E-02
PG1202S-E-03
PG1202S-E-04
PG1202S-E-05
PG1202S-E-06
1200 WATT GENERATOR
17
PG1202S-F-01
PG1202S-F-02
1200 WATT GENERATOR
18
PG1202S-G-01
PG1202S-G-02
PG1202S-G-03
PG1202S-G-04
PG1202S-G-05
PG1202S-G-06
(M6 X 16)
1200 WATT GENERATOR
19
PG1202S-H-01
PG1202S-H-02
PG1202S-H-03
PG1202S-H-04
PG1202S-H-05
PG1202S-H-06
PG1202S-H-07
PG1202S-H-09
PG1202S-H-10
PG1202S-H-08
PG1202S-H-11
PG1202S-H-12
PG1202S-H-13
PG1202S-H-14
PG1202S-H-15
PG1202S-H-16
PG1202S-H-17
(M6 X 12)
1200 WATT GENERATOR
20
PG1202S-I-01
PG1202S-I-02
PG1202S-I-03
(M6 X 16)
1200 WATT GENERATOR
I
21
PG1202S-J-01
PG1202S-J-02
PG1202S-J-03
PG1202S-J-04
PG1202S-J-05
PG1202S-J-06
PG1202S-J-07
PG1202S-J-09
PG1202S-J-10
PG1202S-J-11
PG1202S-J-12 WASHERS
PG1202S-J-08
12
12
(M6 X 20)
(M6 X 32)
1200 WATT GENERATOR
22
PG1202S-K-01
PG1202S-K-02
PG1202S-K-03
PG1202S-K-04
PG1202S-K-05
PG1202S-K-06
PG1202S-K-07
PG1202S-K-09
PG1202S-K-10
PG1202S-K-08
PG1202S-K-11
PG1202S-K-12
PG1202S-K-13
PG1202S-K-14
PG1202S-K-15
PG1202S-K-16
PG1202S-K-17
(M5 X 15)
(M6 X 60)
(M6 X 30)
(ST4 X 16)
(ST4 X 10)
1200 WATT GENERATOR
23
PG1202S-K-18
PG1202S-K-19
PG1202S-K-20
PG1202S-K-21
1200 WATT GENERATOR
24
PG1202S-L-01
PG1202S-L-02
PG1202S-L-03
PG1202S-L-04
PG1202S-L-05
PG1202S-L-06
PG1202S-L-07
PG1202S-L-09
PG1202S-L-08
1200 WATT GENERATOR
25
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Pulsar PG1202S Owner's manual

Category
Power generators
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI