Convair Climate Wizard Owner's manual

Type
Owner's manual

Convair Climate Wizard is a climate control solution that addresses common problems associated with heating in winter, such as excessive temperature, dryness, static electricity, and dust. It adds moisture to the air, lowers the temperature in overheated rooms, and purifies the air using a filter that reduces airborne contaminants.

Convair Climate Wizard is a climate control solution that addresses common problems associated with heating in winter, such as excessive temperature, dryness, static electricity, and dust. It adds moisture to the air, lowers the temperature in overheated rooms, and purifies the air using a filter that reduces airborne contaminants.

Back View
Congratulations on purchasing a
Convair ClimateWizard. Convair is a
world leader in climate control
solutions.
ClimateWizard addresses the
common problems associated with
heating in winter - excessive
temperature, dryness, static electricity
and dust - which can cause symptoms
such as skin irritations, allergies and
respiratory problems.
ClimateWizard adds moisture to the
air and lowers the temperature in
overheated and dry rooms.
ClimateWizard also purifies the air by
using an air filter which reduces
airborne contaminants.
Component List
A
B
C
D
E
F
H
I
J
K
L
M
Handle Filter cartridge clips
Controls Rear panel
Front grille Filter cartridge &
filter
Water tank
Water filling area
Water level
Rating label
window
Drain plug
Wheel
Rear panel clips
Manual
G
ILL1253-A
ILL1254-A
Front View
02
ILL1253-A
Use this appliance for the intended
use only.
Do not use this appliance outdoors.
Caution: Your ClimateWizard holds
water so be sure to move it carefully.
Do not move the appliance when it
is full of water - it is advisable to
move it into position before filling it.
Caution: Always switch your
ClimateWizard off and unplug it before
filling it with water, cleaning it or
servicing the appliance.
At the end of each season, or at least
monthly if heavily used, it is advisable
to carry out some simple maintenance
on your ClimateWizard. Refer to the
Maintenance section.
Handle Assembly
To attach the handle, push it into the
slot at the back of the appliance until it
clicks into place. The handle has
been designed to be a permanent
addition to the appliance. Do not
attempt to remove it once assembled.
Once firmly secured the handle will aid
in the appliance s manoeuverability.
01
03
Manual
Safety
When using electrical appliances
please follow these precautions to
reduce the risk of fire, electrical
shock and injury to persons.
Warning: This appliance is not
intended for use by young children or
infirm persons without supervision.
Do not use this appliance in a closed
room when only occupied by children.
Caution: Before connecting your
ClimateWizard to an electrical outlet,
check that the required voltage shown
on the rating label is the same as your
power supply.
Caution: This appliance has a
polarized plug (one blade is wider than
the other). To reduce the risk of
electric shock, this plug is intended to
fit in a polarized outlet only one way. If
the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit,
contact a qualified electrician. Do not
attempt to defeat this safety feature.
To avoid accidents and fire hazards,
keep the cord out of heavy traffic
areas, never put near heat registers,
radiators or stoves. Do not use this
appliance if the plug or cord is
damaged. Caution: Do not plug in the
cord with wet hands as electric shock
may result.
This appliance is designed with a
safety feature so that if the rear panel
is removed the appliance will not
operate. Do not attempt to defeat this
safety feature.
01
ILL1255-A
Operation
1. Place the appliance in a central
position in your home or office.
2. Pour clean water into the opening
at the back of the appliance.
The maximum water capacity of the
ClimateWizard is 3.4 gallons (13
liters). The minimum amount of water
required to operate the pump is
gallon (1.9 liters). No damage occurs
to the appliance when it is operated
without water.
3. Fill the appliance with water until
the water reaches the maximum fill
level indicated inside the tank.
Caution: Do not overfill the
appliance as water will spill on
the floor.
4. Refill the appliance with clean water
whenever the water level in the
window is low.
5. Plug the ClimateWizard into the
electrical outlet and turn the power
on.
6. Turn the moisture control knob
( ) to the on position.
7. Turn the power knob ( ) to low
speed. Please note that
maximum moisturizing capacity
will not be reached until the
moisturizing pad is completely
saturated. This may take several
minutes.
8. If the desired comfort level is not
achieved after this time, increase
the fan speed. Lower fan
speeds provide quieter operation.
Manual
04
ILL1257-A
03
05
ILL1260-A
06
ILL1261-A
07
06
07
05
03
ILL1259-A
02
ILL1256-A
02
02
04
ILL1258-A
04
9. If your home or office becomes
uncomfortable and/or water
condensation occurs, decrease
the water flow. Turn the moisture
control knob ( ) off and/or
turn the fan knob ( ) to a lower
setting.
10.Turn your ClimateWizard off by
turning the fan knob ( ) off .
Maintenance
Ensure that the ClimateWizard is
switched off and the plug is removed
from the electrical outlet before any
maintenance is performed.
To clean the exterior of the appliance
use a damp cloth and mild household
detergent.
Note: The tank must be drained of
water before the appliance is stored.
At the end of each season, or more
often if heavily used, it is advisable to
carry out some simple maintenance
on your ClimateWizard. This will help
Manual
maintain its high performance. Follow
the steps below.
1. Drain the water from the appliance.
Move it to a drain and remove the
drain plug located on the bottom of
the tank. When the appliance is
empty replace the plug in the
tank.
2.
. The
filter can be vacuumed or rinsed
with water, however, to maintain
maximum performance it is
recommended that filters be
replaced rather than cleaned. For
approved filter replacements call
1-800-926-6824. To gain access to
the filter, remove the filter cartridge
by disengaging the clips at the
top and pivoting it backwards.
Clean or replace the air filter every
3 months or when required
ILL1264-A
10
11
ILL1281-A
11
10
05
ILL1263-A
09
09
08
ILL1262-A
08
06
3. To gain access to the inside of the
appliance remove the rear panel by
disengaging the clips at the top.
Pivot the rear panel backwards and
lift it off. Take care when
removing the rear panel as water
may drip from the moisturizing pad
secured to the inside of the panel.
4. Wash the moisturizing pad with a
gentle spray of water while it is still
in the rear panel. Do not use a
high pressure hose to clean the pad.
Replace the pad if salt has built-up
on the pad as it will reduce the
ClimateWizard s performance.
5. Clean the tank and the perforated
water strainer located in the tank by
using a damp cloth and mild
13
ILL1267-A
14
ILL1268-A
household detergent. Do not use
abrasive cleaners or solvents.
Remove any foreign matter. This
will ensure that the strainer does
not clog up during operation.
6. If the pump drive belt needs
replacing, remove it from the
pulleys. Ensure that the belt is
replaced in the same orientation
as shown in the diagram so that
the pump rotates in the right
direction.
7. Replace the rear panel by placing
the bottom of the rear panel in the
tank and pivoting it forward until
the clips engage.
ILL1269-A
14
15
16
Manual
15
ILL1280-A
12
13
12
Manual
8. Replace the filter cartridge by
placing the bottom tabs on the
filter cartridge into the rear panel
and pivoting it forward until the top
clips engage.
Any additional maintenance or
servicing should only be performed by
qualified personnel. Failing to do so
may void your warranty.
ILL1266-A
17
17
16
ILL1265-A
07
EspanolManual
08
Condition
1. Appliance will not
operate
2. Appliance stops
operating after
running for some
time
3. No moisturizing
4. Appliance causes an
unpleasant odor
5. Appliance makes
scraping or rattling
noise
6. Water overflows from
the tank
7. Damaged power
supply cord
8. Too much moisture
or room is too cool
Possible Cause
1.1 Power outlet or supply is faulty
1.2 Wrong voltage
1.3 Electrical fault
2.1 Motor has overheated (safety
cutout)
3.1 Moisture control knob is off
3.2 Tank is empty or nearly empty
3.3 Pad and/or pump is blocked or
dirty
3.4 Pump is not working properly
3.5 Pump drive belt faulty or broken
4.1 Tank or pad is dirty
4.2 Water quality is poor
5.1 Dirt has built-up in the pump
6.1 Too much water in the tank
Remedy
1.1.1 Check the power supply
1.1.2 Check the power outlet
1.2.1 Check that the power supply is the same as
that specified on the appliance s rating label
1.3.1 Electrical parts must only be repaired and replaced
by Authorised Service Agents - call Convair
technical support at 1-800-926-6824
2.1.1 Wait 30-45 minutes for the motor to cool down. It
should restart automatically. If this condition
persists, call Convair technical support at
1-800-926-6824
3.1.1 Turn the moisture control knob to on
3.2.1 Fill the tank with water until the water reaches the
maximum water level mark (3.4 gallons)
3.3.1 Clean the parts. See Maintenance section
3.4.1 The pump is not a separate electric pump. It is
connected to the fan and motor and is driven
mechanically. Turn the appliance off and drain the
tank completely. Refill with clean water. Switch fan
knob to high speed, turn the moisture knob to on
and run the appliance for 10-15 minutes. This will
help to flush out the dirt. The pad should now be
wet. If the pad is not wet then the pump is still
clogged. Call Convair technical support at
1-800-926-6824
3.5.1 Replace the drive belt. See Maintenance section
4.1.1 Drain the tank and refill with clean water. If
the odor persists, clean the tank and clean or
replace the moisturizing pad and/or the filter pad
4.2.1 Add vanilla essence or perfume to the water
5.1.1 Clean the parts. See Maintenance section
5.1.2 Replace the drive belt. See Maintenance section
6.1.1 Drain some water out
7.1.1 If the power supply cord is damaged it should be
replaced. Call Convair technical support at
1-800-926-6824
8.1.1 Reduce the fan speed and/or turn the water off.
See Operation section
Troubleshooting
Parts List
09
Description
1 Badge
2 Front Panel
3 Plug & Cord Set
4 Control Box
5 Switch Wire
6 Microswitch
7 Switch
8 Capacitor
9 Control Panel
10 Knob
11 Screw
12 Water Valve
13 Hose to Spreader
14 Chassis
15 Handle
16 Motor Rubber
17 Fan
Description
18 Belt
19 Pad Retainer
20 Moisturizing Pad
21 Rear Panel
22 Air Filter
23 Filter Cartridge
24 Hose to Pump
25 Tank
26 Drain Plug
27 Strainer
28 Rear Wheel
29 Motor
30 Pump Assembly
Warranty Card
STOP label
Owner s Manual
Wiring Diagram
If you need replacement parts or have any questions call 1-800-926-6824
or visit us at www.convaircooler.com
1 2
3
4
5
6 7
8
9
10
141312
11
15
19
18
17
16
23
22
21
20
Exploded View
26
25
24
30
29
28
27
ILL1270-A
10
C
Convair Cooler Corporation
1202 North 54th Ave
Building 2 Suite 117
Phoenix, Arizona 85043
Phone: 602-353-8066
Fax: 602-353-8070
Toll Free: 1-800-926-6824
www.convaircooler.com
2003
828336-A 0306
Cooler Corporation
www.convaircooler.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Convair Climate Wizard Owner's manual

Type
Owner's manual

Convair Climate Wizard is a climate control solution that addresses common problems associated with heating in winter, such as excessive temperature, dryness, static electricity, and dust. It adds moisture to the air, lowers the temperature in overheated rooms, and purifies the air using a filter that reduces airborne contaminants.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI