Marantec Dynamic 400-413 Owner's manual

Type
Owner's manual

Marantec Dynamic 400-413 is an operator system for roller shutters, enabling you to open and close your roller shutters conveniently and effortlessly. It ensures smooth operation and precise positioning of your shutters, enhancing the security and comfort of your home.

Marantec Dynamic 400-413 is an operator system for roller shutters, enabling you to open and close your roller shutters conveniently and effortlessly. It ensures smooth operation and precise positioning of your shutters, enhancing the security and comfort of your home.

Dynamic 400 - 413
O
perator system for roller shutters
GB
Manual for installation and operation
1. Meaning of symbols . . . . . . . . . . . . . . . . . .2
2
. Table of contents . . . . . . . . . . . . . . . . . . . . .2
3. General safety advice . . . . . . . . . . . . . . . . .3
4. Preparation for mounting . . . . . . . . . . . . . .4
4.1 General notes . . . . . . . . . . . . . . . . . . . .4
4.2 Checks . . . . . . . . . . . . . . . . . . . . . . . . .4
5. Installation . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.1 Mounting the consoles . . . . . . . . . . . . .5
5.2 Install the motor unit . . . . . . . . . . . . . .6
5.3 Mounting the controls . . . . . . . . . . . . .8
5.4 Emergency operation . . . . . . . . . . . . . .9
6. Initial operation . . . . . . . . . . . . . . . . . . . . .10
6.1 Check the rotational direction . . . . . . .10
6.2 Overview of the control cams . . . . . . .11
6.3 Setting the CLOSED shutter position . .12
6.4 Setting the OPEN shutter position . . . .13
6.5 Setting the CESD-STOP switch . . . . . .14
6.6 Setting the ADD-ON positioning
switch . . . . . . . . . . . . . . . . . . . . . . . . .14
6.7 Completing the installation . . . . . . . . .15
7. Attachment . . . . . . . . . . . . . . . . . . . . . . . . .16
7.1 Circuit diagram for
Dynamic 410 - 413 (230 V / 1 phase) .16
7.2 Circuit diagram for
Dynamic 400 - 406 (400 V / 3 phase) .17
7.3 Circuit diagram for
Dynamic 400 - 406 (400 V / 3 phase)
with additional motor brake . . . . . . . .18
7.4 Technical data . . . . . . . . . . . . . . . . . . .19
7.5 Manufacturer’s Declaration . . . . . . . . .23
7.6 EC Declaration of Conformity . . . . . . .23
Caution!
Danger of personal injury!
The following safety advice must
be observed at all times so as to avoid
personal injury!
Attention!
Danger of material damage!
The following safety advice must
be observed at all times so as to avoid
material damage!
Advice / Tip
Check
Reference
i
Advice
Type plate on control unit
Type: ________________________________________________
Art. No.: _____________________________________________
Product No.: __________________________________________
Type plate on motor unit
Type: ________________________________________________
Art. No.: _____________________________________________
Product No.: _________________________________________
2 Manual for installation and operation, Dynamic 400 - 413 GB (#77418)
2. Table of contents1. Meaning of symbols
Please read carefully!
Target group
This operator system may only be installed, connected and put into
operation by qualified and trained professionals!
Qualified and trained specialist personnel are persons
- who have knowledge of the general and special safety regulations,
- who have knowledge of the relevant electro-technical regulations,
- with training in the use and maintenance of suitable safety
equipment,
- who are sufficiently trained and supervised by qualified electricians,
- who are able to recognise the particular hazards involved when
working with electricity,
Warranty
For an operations and safety warranty, the advice in this instruction
manual has to be observed. Disregarding these warnings may lead
to personal injury or material damage. If this advice is disregarded,
the manufacturer will not be liable for damages that might occur.
Batteries, fuses and bulbs are excluded from warranty.
To avoid installation errors and damage to the door and operator
system, it is imperative that the installation instructions are followed.
The system may only be used after thoroughly reading the respective
mounting and installation instructions.
The installation and operating instructions are to be given to the
door system user, who must keep them safe.
They contain important advice for operation, checks and
maintenance.
This item is produced according to the directives and standards
mentioned in the Manufacturer's Declaration and in the Declaration
of Conformity. The product has left the factory in perfect condition
with regard to safety.
Power-operated windows, doors and gates must be checked by an
expert (and this must be documented) before they are put into
operation and thereafter as required, but at least once a year.
Correct use
The operator system is intended for opening and shutting roller
shutters.
Beside the advice in these instructions, please observe the
general safety and accident prevention regulations!
Our sales and supply terms and conditions are effective.
Information on installing the operator system
• When installing a new operator system for the first time (in
connection with the installation of a roller shutter), you must
observe the safety instructions for the roller shutter in question.
• Render any installations inoperable that will no longer be needed
after the operator system has been installed.
• Before commencing cabling works, you MUST disconnect the
operator system from the mains supply.
Adhere to the safety period of 10 seconds to guarantee that the
operator system is voltage free.
• Adhere to the local protection regulations.
• Lay the electricity supply cables and control cables; these MUST be
laid separately. The controls voltage is 24 V DC.
• Install all the impulse transmitters and control devices (e.g. remote
control buttons) within sight of the door and at a safe distance
from the moving parts of the door. A minimum installation height
of 1.5 m must be observed.
• Ensure that no part of the door extends across public footways or
roads when the installation is complete.
Information on commissioning the operator system
After initial operation, the persons responsible for operating the
door system, or their representatives must be familiarised with the
use of the system.
• Make sure that children cannot access the door control unit.
• Before moving the door, make sure that there are neither persons
nor objects in the operating range of the door.
• Test all existing emergency command devices.
• Never insert your hands into a running door or moving parts.
Information on servicing the operator system
To ensure proper operation, the following items must be checked
regularly and repaired if necessary. Before any works to the door
system are undertaken, the operator system must be disconnected
from the mains.
• Check once a month to ensure that the operator system reverses
if the door encounters an obstacle. Depending on the operational
direction of the door, place a 50 mm high/wide obstacle in its
path.
• Check all movable parts of the door and operator system.
• Check the door system for signs of wear or damage.
Information on cleaning the operator system
Never use water jets, high pressure cleaners, acids or bases for
cleaning.
3. General safety advice
Manual for installation and operation, Dynamic 400 - 413 GB (#77418) 3
4.2 Checks
Attention!
In order to guarantee correct
mounting, carry out the following
checks before installing.
Supply package
• Check the package to ensure that all the parts are
included.
4. Preparation for mounting
4.1 General notes
The instructions describe the following installation
situations:
-
First time installation of a new operator system
(in connection with the installation of a new roller
shutter).
The pictures in these instructions are not true-to-scale.
Dimensions are always given in millimetres (mm)!
The operator system can be installed on the left or the
right hand side of the shutter.
The operator side may be predetermined on site by the
dimensions of the sleeve shaft in the roller curtain.
In this instruction manual, the installation is shown on
the right hand side.
Reference:
When installing a new operator system
for the first time (in connection with
the installation of a roller shutter),
you must observe the shutter
manufacturer’s safety instructions.
i
Advice:
Motor units with an emergency hand
chain on the right hand side must be
installed on the inside of the door on
the right hand side.
Advice:
Fixing materials and feather keys are
not included in the package.
• Check that you have all the necessary accessories
and parts required for your particular installation
situation:
- Motor console
- Pedestal bearings
- Feather keys
- Fixing materials
- Junction box
(if an existing control unit is to be used)
Installation site
• Check to ensure that the installation site has a
suitable mains connection.
Motor unit
Check
- whether the motor unit has a long enough cable for
the shutter,
- whether the shaft end fits perfectly into the sleeve
shaft of the motor unit,
- whether the feather key fits in the sleeve shaft and
the motor unit.
4 Manual for installation and operation, Dynamic 400 - 413 GB (#77418)
5.1 Mounting the consoles
5.1.1 / 1
Attention!
In order to guarantee proper operation
of the roller shutter, the consoles must
be mounted in such a way that the
winding shaft of the shutter curtain
runs horizontally.
A Difference in height of the consoles
The height difference is determined by the
different dimensions of the pedestal bearing
and the motor unit.
B Distance from centre of winding shaft to
floor
If the shutter and motor unit are to be installed
at the same time, this dimension is specified by
the manufacturer of the roller shutter.
If the motor unit is being replaced, the distance
must be the same as the previous distance.
C Distance between the consoles
The distance between the consoles is
dependent on the length of the winding shaft.
D Distance from centre of winding shaft to
guide rail
If the shutter and motor unit are to be installed
at the same time, this dimension is specified by
the manufacturer of the roller shutter.
If the operator is being replaced, the distance
must be the same as the previous distance.
E Distance of console from doorway opening
The distance of the console from the doorway
opening is dependent on the position of the
shutter curtain on the winding shaft.
F Motor unit
G Pedestal bearing
A
B
C
5.1.1 / 2
A
5.1.1 / 3
C
B
E
E
DD
F
F
F
G
G
G
5
.1.1 Mounting specifications
5. Installation
Manual for installation and operation, Dynamic 400 - 413 GB (#77418) 5
5. Installation
5
.1.2 Screw the consoles in place
Determine the mounting position of the consoles.
Screw the consoles in place.
Attention!
To guarantee the proper operation of
the shutter system, the consoles must
comply with the installation
specifications.
Caution!
In order to prevent the shutter curtain
from falling, screw fixings must be used
that support the weight of the shutter
curtain securely.
• Check whether the existing consoles (if applicable)
meet the installation specifications.
If the mounting positions do not correspond exactly,
the consoles must be adjusted.
Caution!
To avoid injury, it is imperative that you
observe the following:
- The shutter curtain must be placed on
the consoles with the help of a
suitable installation aid (e.g. forklift
truck with appropriate working load).
- The shutter curtain must be secured in
position (e.g. to prevent it from
turning right over).
5.2 Install the motor unit
5.2 / 1
• Grease the shaft pins of the motor unit and the
bearing.
• Place the feather keys in the grooves of the sleeve
shaft.
• Push the pedestal bearing and the motor unit onto
the roller shutter curtain.
• Place the roller shutter curtain with the pedestal
bearing and motor unit onto the consoles.
5.1.2 / 1
6 Manual for installation and operation, Dynamic 400 - 413 GB (#77418)
5. Installation
5.2 / 2
D
D
Attention!
For correct installation, the sleeve shaft
and the pedestal bearing must be
positioned so that the distance (D) from
the guide rail is identical.
• Adjust the positions of the motor unit and pedestal
bearing.
Screw the motor unit to the console.
Screw the pedestal bearing to the console.
Manual for installation and operation, Dynamic 400 - 413 GB (#77418) 7
Motor unit with emergency hand chain
• Secure the emergency hand chain at the side of the
door.
5.2 / 3
5
.3.2 Connect an existing control unit
Connect the controls to the motor unit.
Connect the controls to the mains power supply.
Caution!
During cabling works, the mains cable
must be at zero voltage.
Reference:
For the functions, installation and ope-
ration of the controls, please refer to
and follow the relevant instructions.
i
Attention!
To ensure proper operation of the
controls,
- the circuit diagrams for the motor unit
and the controls must be taken into
consideration,
- for protection grade IP 65 an
appropriate plug-in connection must
be selected,
- for a fixed connection to the mains
power supply, a universally poled
mains switch must be installed.
5. Installation
5.3.1 / 1
Mount the controls near to the shutter.
Connect the controls to the motor unit.
Connect the controls to the mains power supply.
Caution!
During cabling works, the mains cable
must be at zero voltage.
Reference:
For the operation of the controls,
the instructions for the controls must
be followed.
i
5.3 Mounting the controls
5
.3.1 Mounting a new control unit
Attention!
To ensure proper operation of the
controls,
- the circuit diagrams for the motor unit
and the controls must be taken into
consideration,
- for protection grade IP 65 an
appropriate plug-in connection must
be selected,
- for a fixed connection to the mains
power supply, a universally poled
mains switch must be installed.
8 Manual for installation and operation, Dynamic 400 - 413 GB (#77418)
5. Installation
5.4 Emergency operation
Caution!
To avoid injury, the following points
must be observed:
- Emergency operation may only be
carried out from a safe standing
position.
- The mains supply cable must be at
zero voltage.
Advice:
If the shutter is moved beyond the
door OPEN or CLOSED positions, the
power supply remains disconnected.
(Emergency positioning switch
OPEN/CLOSE).
In the case of an electrical fault, the door can be
moved in the OPEN or CLOSE directions using the
emergency operation facility.
Manual for installation and operation, Dynamic 400 - 413 GB (#77418) 9
Advice:
The shutter cannot be moved until
the crank is engaged in the end of
the motor unit shaft.
The motor unit is cut out electrically.
5
.4.1 Operation using the emergency hand crank
5.4.1 / 1
Activate the emergency operation facility
Remove the crank from its fixing on the motor unit.
• Insert the crank into the shaft of the motor unit with
a slight turning movement.
OPEN the shutter:
Turn the crank clockwise.
CLOSE the shutter:
Turn the crank anti-clockwise.
Deactivate the emergency operation facility
Pull the crank out of the motor unit.
The shutter may now be operated electrically.
Push the crank back into its fixing on the motor unit.
10 Manual for installation and operation, Dynamic 400 - 413 GB (#77418)
6.1 Check the rotational direction
Reference:
Section 5.4 must be observed for
emergency operation.
For the controls, the relevant
instruction manual must be observed.
i
• Using the emergency operation facility, move the
door to an intermediate position.
Deactivate the emergency operation facility.
Switch on the power supply.
Press the OPEN button on the control unit.
The shutter moves in the OPEN direction.
The rotational direction has been set correctly.
The shutter moves in the CLOSE direction.
Change the rotational direction.
5. Installation
Activate the emergency hand chain function:
Pull on the red chain handle (A).
The shutter can now be opened or closed using the
emergency hand chain.
Deactivate the emergency hand chain function:
Pull on the green chain handle (B).
• Secure the emergency hand chain at the side of the
shutter.
The shutter may now be operated electrically.
5.4.2 / 1
Release the emergency hand chain from its fixing.
5
.4.2 Operation using the emergency hand chain
A
B
Advice:
The path of the drive chain (A + B) is
restricted by guide rings. If it is not
possible to activate or deactivate the
function, the chain guard (with the
drive chain) must be turned once on
its axis.
6. Initial operation
Advice:
The CESD-STOP positioning switch will
function with all the control units indi-
cated in the operating instructions.
S15
S14
S13 S11 S9a
S9
6.2 / 1
Emergency positioning switches OPEN/CLOSE
The emergency positioning switches serve as a safety
device.
S9 emergency OPEN positioning switch (red cam)
S9a emergency CLOSE positioning switch (red cam)
Positioning switches OPEN/CLOSE
The positioning switches switch off the shutter when it
reaches the end position.
S11 OPEN positioning switch (green cam)
S13 CLOSE positioning switch (green cam)
Positioning switch for CESD-STOP
The CESD-STOP positioning switch deactivates the
reversing function of the closing edge safety system.
S14 CESD-STOP positioning switch (black cam)
Attention!
To prevent the controls from being
damaged, it is imperative that you
observe the following points:
- The positioning switches in the switch
groups S11 - S15 must all be supplied
by the same voltage.
- The positioning switches in the switch
groups S9 - S9a must all be supplied
by the same voltage.
ADD-ON positioning switch
The ADD-ON positioning switch allows for the
connection of additional devices.
S15 ADD-ON positioning switch
(max.~230 V / 2A (white cam))
Manual for installation and operation, Dynamic 400 - 413 GB (#77418) 11
6. Initial operation
6.2 Overview of the control cams
6. Initial operation
Fine adjustments can be made with the socket head
screw (C).
• Using the emergency operation facility, move the
door back to the desired CLOSED door position.
The CLOSE positioning control cam (S13, green cam)
must be in the following position:
The positioning control cam activates the switch.
• Fix the CLOSED shutter position by tightening the
fixing screw (B) on positioning control cam S13.
Fine adjustments can be made with the socket head
screw (C).
Advice:
The switching interval between the
activation of the emergency positioning
switch and the activation of the
positioning switch must be as short as
possible, (the operating temperature of
the motor unit can cause the shutter to
be driven beyond the CLOSED shutter
position).
12 Manual for installation and operation, Dynamic 400 - 413 GB (#77418)
Open the cover of the positioning control cams (A).
• Drive the shutter electrically to the desired CLOSED
shutter position.
• Drive the shutter just a fraction beyond the CLOSED
shutter position.
6.3 / 2
6.3 / 1
A
S15
S14
S
13
S11
S9a
S9
B
C
6.3 Setting the CLOSED shutter position
The emergency CLOSE positioning control cam (S9a,
red cam) must be in the following position:
The positioning control cam activates the switch.
• Fix the emergency CLOSE position by tightening the
fixing screw (B) on positioning control cam S9a.
Attention!
Before the OPEN/CLOSED shutter
positions have been set, the shutter can
be driven electrically beyond the shutter
positions, which could result in damage.
6. Initial operation
6.4 Setting the OPEN shutter position
6.4 / 1
6.4 / 2
B
C
S
15
S14
S
13
S11
S9a
S9
• Drive the shutter electrically to the desired OPEN
shutter position
• Drive the shutter just a fraction beyond the OPEN
shutter position
The emergency OPEN positioning control cam (S9,
red cam) must be in the following position:
The positioning control cam activates the switch.
• Fix the emergency OPEN position by tightening the
fixing screw (B) on positioning control cam S9.
Caution!
Before the OPEN/CLOSED shutter
positions have been set, the shutter can
be driven electrically beyond the shutter
positions, which could result in damage
or injury due to the bottom end of the
shutter curtain turning over the roll.
Manual for installation and operation, Dynamic 400 - 413 GB (#77418) 13
Fine adjustments can be made with the socket head
screw (C).
• Using the emergency operation facility, move the
door back to the desired OPEN door position.
The OPEN positioning control cam (S11, green cam)
must be in the following position:
The positioning control cam activates the switch.
• Fix the OPEN shutter position by tightening the fixing
screw (B) on positioning control cam S11.
Fine adjustments can be made with the socket head
screw (C).
Advice:
The switching interval between the
activation of the emergency positioning
switches and the activation of the
OPEN/CLOSE positioning switches must
be as short as possible, (the operating
temperature of the motor unit can
cause the shutter to be driven beyond
the OPEN shutter position).
6. Initial operation
6.6 Setting the ADD-ON positioning
switch
6.6 / 1
S15
S14
S13
S11
S9a
S9
B
C
Drive the shutter electrically to the desired position.
The ADD-ON positioning control cam (S15, white cam)
must be in the following position:
The positioning control cam activates the switch.
• Fix the position by tightening the fixing screw (B) on
positioning control cam S15.
Check to ensure that it functions correctly.
Drive the shutter in the opposite direction
Drive the shutter to the desired position.
The system should carry out the desired operation.
Fine adjustments can be made with the socket head
screw (C).
14 Manual for installation and operation, Dynamic 400 - 413 GB (#77418)
S15
S14
S13
S11
S9a S9
6.5 / 1
B
C
• Drive the shutter electrically to the desired CLOSED
shutter position.
Open the shutter by not more than 40 mm.
The CESD-STOP positioning control cam (S14, black cam)
must be in the following position:
The positioning control cam activates the switch.
• Fix the position by tightening the fixing screw (B) on
positioning control cam S14.
Check to ensure that it functions correctly.
Drive the shutter in the OPEN direction.
• Drive the shutter in the CLOSE direction, with an
obstacle (not taller than 40 mm) placed in its path.
The system should stop.
The reversing function is deactivated when the switch
is depressed.
Fine adjustments can be made with the socket head
screw (C).
6.5 Setting the CESD-STOP switch
Manual for installation and operation, Dynamic 400 - 413 GB (#77418) 15
6. Initial operation
6.7 Completing the installation
• Check to ensure that all installed components are
correctly installed.
Check all the settings for the shutter and operator.
Close all motor and control housings.
• Affix all the warning signs permanently and ensure
that they can be clearly seen by the operator at all
times.
Check the emergency manual operation facility.
16 Manual for installation and operation, Dynamic 400 - 413 GB (#77418)
7.1 Circuit diagram for Dynamic 410 - 413 (230 V / 1 phase)
Key to circuit diagram for Dynamic 410 - 413 (230 V / 1 phase)
-S9
1
2
11
-S9a
12
11
-
S10
1
2 1
1
-X5
3
4
2
6
M1~
-M1
Z1
U
1
UZ2
PE
N
A
UF
4
5
PE
PE
-W1
g/y
1 2 3 4 5
-W2
g/y
1 2 4 5 7 8 9 10 11
-S15 -S14 -S13 -S11 -S9a -S9
1)
1
)
1
)
-C1
2
1
-S11 -S13 -S14
-X4
30
31
5
1
61
UZ
2
Z1
3
4
1
5
-S15
-X3
U1
-X2
ZU
PE
PE
Control 70
AS 210 B
PE
ZU
N
AUF
11
1
2
9
8
7
6
5
4
3
2
1
Attention!
To avoid damage, it is imperative that you observe the following points:
- The local safety regulations must be adhered to at all times.
- The power supply and control cables MUST be laid separately.
- The control voltage is 24 V DC.
- The positioning switches in switch group S11 - S15 must all be supplied by the same voltage
(max. ~230 V 2A).
- The positioning switches in switch group S9 - S9a must all be supplied by the same voltage
(max. ~230 V 2A).
7.1 / 1
M10E029
Label Description
1) Insulation discs
C1 Motor capacitor
M1 Motor 1N~ 230 V
S9 Emergency OPEN positioning switch (red cam)
S9a Emergency CLOSE positioning switch (red cam)
S10 Safety switch for emergency hand device
S11 OPEN positioning switch (green cam)
S13 CLOSE positioning switch (green cam)
Label Description
S14 CESD-STOP positioning switch (black cam)
S15 ADD-ON positioning switch (white cam)
W1 Motor power supply cable 12 x 1
W2 Control cable 7 x 1
X2 Terminal block of motor cable / AS 210 B
X3 Terminal block of motor cable / Control 70
X4 Terminal block of limit switch / Control 70
X5 Terminal block of limit switch / AS 210 B
7. Attachment
7.2 Circuit diagram for Dynamic 400 - 406 (400 V / 3 phase)
Manual for installation and operation, Dynamic 400 - 413 GB (#77418) 17
7. Attachment
Key to circuit diagram for Dynamic 400 - 406 (400 V / 3 phase)
-S9
1
2
11
-S9a
12
1
1
-
S10
1
2 1
1
-X1
16
36
37
46
M
1~
-M1
W
U
V
PE
V
W
4
5
PE
PE
-W1
g/y
1 2 3 4 5
-W2
g/y
1 2 4 5 7 8 9 10 11
-S11 -S13 -S14
-X4
30
31
51
61
V
W
3
4
17
26
-S15
-X3
U
-X
U
P
EPE
Control 70
MS 400
PE
U
V
W
11
12
9
8
7
6
5
4
3
2
1
-S15 -S14 -S13 -S11 -S9a -S9
1
)
1)
1)
-
X5
3
4
2
6
V
W
4
5
PE
PE
1
5
-
X2
U
-X11
1
2
4
8
V
W
B
1
B2
PE
PE
3
7
-X2
U
CS 300 ME
AS 210 B
Attention!
To avoid damage, it is imperative that you observe the following points:
- The local safety regulations must be adhered to at all times.
- The power supply and control cables MUST be laid separately.
- The control voltage is 24 V DC.
- The positioning switches in switch group S11 - S15 must all be supplied by the same voltage
(max. ~230 V 2A).
- The positioning switches in switch group S9 - S9a must all be supplied by the same voltage
(max. ~230 V 2A).
7.2 / 1
M10E030
Label Description
1) Insulation discs
M1 Motor 3N~ 400 V
S9 Emergency OPEN positioning switch (red cam)
S9a Emergency CLOSE positioning switch (red cam)
S10 Safety switch for emergency hand device
S11 OPEN positioning switch (green cam)
S13 CLOSE positioning switch (green cam)
S14 CESD-STOP positioning switch (black cam)
S15 ADD-ON positioning switch (white cam)
Label Description
W1 Motor power supply cable 12 x 1
W2 Control cable 7 x 1
X Terminal block of motor cable / MS400
X1 Terminal block of limit switch / MS400
X2
Terminal block of motor cable / AS210B or
CS300ME
X3 Terminal block of motor cable / Control 70
X4 Terminal block of limit switch / Control 70
X5 Terminal block of limit switch / AS210B
X11 Terminal block of limit switch / CS300ME
7. Attachment
18 Manual for installation and operation, Dynamic 400 - 413 GB (#77418)
7.3 Circuit diagram for Dynamic 400 - 406 (400 V / 3 phase) with additional motor brake
Key to circuit diagram for Dynamic 400 - 406 (400 V / 3 phase) with additional motor brake
-S9
12 11
-S9a
12 11
-S10
12 11
-
W1
g/y
1 2 3 4 5
-
W2
g/y
1 2 4 5 7 8 9 10 11
-S11 -S13 -S14
-X4
30
31
51
6
1
V
W
3
4
-S15
-X3
U
PE
PE
Control 70
PE
U
V
W
11
12
9
8
7
6
5
4
3
2
1
-S15 -S14 -S13 -S11 -S9a -S9
1
)
1)
1)
+
Loc
-X5
3
4
2
6
V
W
4
5
PE
PE
1
5
-X2
U
-X11
1
2
4
8
V
W
B1
B
2
P
E
PE
3
7
-X2
U
CS 300 ME
AS 210 B
8 9
1
2
Brake
Brake 148
M
1~
~
-M1
Motor 3~ 400V
W
U
V
PE
-X5
7
2)
2)
-X11
13
2)
Attention!
To avoid damage, it is imperative that you observe the following points:
- The local safety regulations must be adhered to at all times.
- The power supply and control cables MUST be laid separately.
- The control voltage is 24 V DC.
- The positioning switches in switch group S11 - S15 must all be supplied by the same voltage
(max. ~230 V 2A).
- The positioning switches in switch group S9 - S9a must all be supplied by the same voltage
(max. ~230 V 2A).
7.3 / 1
M10E031
Label Description
1) Insulation discs
2)
Switch contact brake (must be closed when
motor is running)
M1 Motor 3N~ 400 V
S9 Emergency OPEN positioning switch (red cam)
S9a Emergency CLOSE positioning switch (red cam)
S10 Safety switch for emergency hand device
S11 OPEN positioning switch (green cam)
S13 CLOSE positioning switch (green cam)
S14 CESD-STOP positioning switch (black cam)
Label Description
S15 ADD-ON positioning switch (white cam)
W1 Motor power supply cable 12 x 1
W2 Control cable 7 x 1
X1 Terminal block of limit switch / CS300ME
X2
Terminal block of motor cable /
AS 210 B or CS 300 ME
X3 Terminal block of motor cable / Control 70
X4 Terminal block of limit switch / Control 70
X5 Terminal block of limit switch / AS 210 B
X11 Terminal block of limit switch / CS300ME
7.4 Technical data
Electrical data / Type
410-
140/12
412-
220/12
413-
280/12
413-
380/12
Mains voltage V 230 V / 1 phase
Rated frequency Hz 50
Input current A 8 9,5 12,0 14,0
Motor power kW 0,55 0,75 1,1
Motor duty cycle (ED) % S3 – 25
Power supply for external elements V Dependent upon the control
Protection category IP 54
Protection class I
Mechanical data / Type
410-
140/12
412-
220/12
413-
280/12
413-
380/12
Driving torque Nm 140 220 280 380
Nominal RPM min
-1
12
Max. revolutions, driven shaft 13 18
Emergency operation Emergency hand crank (KU) or emergency hand chain (KE)
Drive unit disengagement Does not include integrated safety catch device
Max. safety catch torque Nm 692 1188 1833
Permissible torque Nm 151 259 432
Sleeve shaft diameter mm 30 40
Physical and ambient data / Type
410-
140/12
412-
220/12
413-
280/12
413-
380/12
Dimensions mm See dimensional drawings
Weight kg 23/26 23/26 26/29 26/26
Temperature range -10 to +60
Mounting versions Push-on or flange mounting
Technical data for Dynamic 410 - 413/ Roller shutter operator systems (230 V / 1 phase)
Manual for installation and operation, Dynamic 400 - 413 GB (#77418) 19
7. Attachment
20 Manual for installation and operation, Dynamic 400 - 413 GB (#77418)
7. Attachment
Physical and ambient data / Type
400-
140/12
402-
150/17
402-
220/12
403-
300/12
403-
420/12
403-
500/12
Dimensions mm See dimensional drawings
Weight kg 25/28 23/26 23/26 26/29 30/35 32/35
Temperature range -10 to +60
Mounting versions Push-on or flange mounting
Electrical data / Type
400-
140/12
402-
150/17
402-
220/12
403-
300/12
403-
420/12
403-
500/12
Mains voltage V 400 V / 3 phase
Rated frequency Hz 50
Input current A 2,1 2,8/2,6 2,8/2,6 3,6 5,1/3,3 4,5/4,3
Motor power kW 0,37 0,75 1,1
Motor duty cycle (ED) % S3 – 60
Power supply for external elements V Dependent upon the control
Protection category IP 54
Protection class I
Mechanical data / Type
400-
140/12
402-
150/17
402-
220/12
403-
300/12
403-
420/12
403-
500/12
Driving torque Nm 140 150 220 300 420 500
Nominal RPM min
-1
12 17 12
Max. revolutions, driven shaft 13 18
Emergency operation Emergency hand crank (KU) or emergency hand chain (KE)
Drive unit disengagement Does not include integrated safety catch device
Max. safety catch torque Nm 692 1188 1833 1982
Permissible torque Nm 151 259 432 503
Sleeve shaft diameter mm 30 40
Technical data for Dynamic 400 406 Roller shutter operator systems (400 V / 3 phase)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Marantec Dynamic 400-413 Owner's manual

Type
Owner's manual

Marantec Dynamic 400-413 is an operator system for roller shutters, enabling you to open and close your roller shutters conveniently and effortlessly. It ensures smooth operation and precise positioning of your shutters, enhancing the security and comfort of your home.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI