Marantec EM 172 Owner's manual

Type
Owner's manual
Expansion module EM 172
I/O module MSBUS
94
1 2 DIP
MSBUS
XW41A
ON
OFF
I1/Q1 I2/Q2 I3/Q3 I4/Q4
92 H1 94 92 H1 H137B 37A 36B 37B
Q3 Q1Q2Q4
I/O MODUL
XW41B XW41C
B5 36
I1 I2 I3 I4
37 B5 31 32
Manual for installation and operation
GB
2 Manual for installation and operation, Expansion module EM 172 GB (#114684 / 1700018895)
2. Table of contents
Caution!
Danger of personal injury!
The following safety advice must be
observed at all times so as to avoid
personal injury!
Attention!
Danger of material damage!
The following safety advice must be
observed at all times so as to avoid
material damage!
Advice / Tip
Check
Reference
i
Advice
1. Meaning of symbols . . . . . . . . . .2
2. Table of contents . . . . . . . . . . . .2
3. General safety advice . . . . . . . . .3
4. Product overview . . . . . . . . . . . .5
5. Installation . . . . . . . . . . . . . . . . .5
5.1 Install expansion module . . . . .5
5.2 Wiring of the expansion
module . . . . . . . . . . . . . . . . . .6
6. Programming . . . . . . . . . . . . . .10
7. Appendix . . . . . . . . . . . . . . . . . .11
1. Meaning of symbols
Manual for installation and operation, Expansion module EM 172 GB (#114684 / 1700018895) 3
3. General safety advice
Target group
This operator system may only be installed, connected and put into operation by qualified and trained
professionals!
Qualified and trained specialist personnel are persons
- who have knowledge of the general and special safety regulations,
- who have knowledge of the relevant electro-technical regulations,
- with training in the use and maintenance of suitable safety equipment,
- who are sufficiently trained and supervised by qualified electricians,
- who are able to recognise the particular hazards involved when working with electricity,
- with knowledge regarding applications of the EN 12635 standard (installation and usage requirements).
Warranty
For an operations and safety warranty, the advice in this instruction manual has to be observed.
Disregarding these warnings may lead to personal injury or material damage. If this advice is disregarded,
the manufacturer will not be liable for damages that might occur.
To avoid installation errors and damage to the device, it is imperative that the installation instructions are
followed. The product may only be operated after reading these installation and operating instructions.
The installation and operating instructions are to be given to the door system user, who must keep them
safe. They contain important advice for operation, checks and maintenance.
This item is produced according to the directives and standards mentioned in the Manufacturer's
Declaration and in the Declaration of Conformity. The product has left the factory in perfect condition with
regard to safety.
Power-operated windows, doors and gates must be checked by an expert (and this must be documented)
before they are put into operation and thereafter as required, but at least once a year.
Correct use
The expansion module expands the Control vario control unit to include a two-way traffic control function.
Beside the advice in these instructions, please observe the general safety and accident
prevention regulations! Our sales and supply terms and conditions are effective.
Please read carefully!
3. General safety advice
Installation tips
• Ensure that the devices to be connected (doors etc.) are in a mechanically faultless state.
• Before commencing cabling works it is very important to disconnect the system from the electricity supply.
Ensure that the electricity supply remains disconnected throughout the cabling works.
• Adhere to the local protection regulations.
• Lay the electricity supply cables and control cables; these MUST be laid separately.
The operating voltage is 24 V.
Information on cleaning the operator system
Never use water jets, high pressure cleaners, acids or bases for cleaning.
Please read carefully!
4 Manual for installation and operation, Expansion module EM 172 GB (#114684 / 1700018895)
94
1 2 DIP
MSBUS
XW41A
ON
OFF
I1/Q1 I2/Q2 I3/Q3 I4/Q4
92 H1 94 92 H1 H137B 37A 36B 37B
Q3 Q1Q2Q4
I/O MODUL
XW41B XW41C
B5 36
I1 I2 I3 I4
37 B5 31 32
94
1 2 DIP
MSBUS
XW41A
ON
OFF
I1/Q1 I2/Q2 I3/Q3 I4/Q4
92 H1 94 92 H1 H137B 37A 36B 37B
Q3 Q1Q2Q4
I/O MODUL
XW41B XW41C
B5 36
I1 I2 I3 I4
37 B5 31 32
Manual for installation and operation, Expansion module EM 172 GB (#114684 / 1700018895) 5
Supply package
Dimensions
1 Expansion module
2 System cable coded
3 MSBUS cable
94
1 2 DIP
MSBUS
XW41A
ON
OFF
I1/Q1 I2/Q2 I3/Q3 I4/Q4
92 H1 94 92 H1 H137B 37A 36B 37B
Q3 Q1Q2Q4
I/O MODUL
XW41B XW41C
B5 36
I1 I2 I3 I4
37 B5 31 32
126
85
46
4 / 2
5.1 Install expansion module
• Fit the expansion module (B) to the DIN rail (A).
5.1 / 1
B
5. Installation4. Product overview
4 / 1
1
2
3
A
94
1 2 DIP
MSBUS
XW41A
ON
OFF
I1/Q1 I2/Q2 I3/Q3 I4/Q4
92 H1 94 92 H1 H137B 37A 36B 37B
Q3 Q1Q2Q4
I/O MODUL
BX 36
I1 I2 I3 I4
37 BX 31 32
WC 41B WC 415
AB C
DEF
G
H
5. Installation
6 Manual for installation and operation, Expansion module EM 172 GB (#114684 / 1700018895)
Label Type / function
i
XW41A Connection MSBUS
5.2.2 / 1
XW41B
Connection for further
module
5.2.2 / 1
XW41C
Connection for further
module
5.2.2 / 1
XB53A Input 1 and 2
5.2.2 / 2
XB53B Input 3 and 4
5.2.2 / 3
XH13 Output 1 and 2
5.2.2 / 4
XH19A Output 3
5.2.2 / 5
XH19B Output 4
5.2.2 / 6
DIP 1 DIP 2
Module
address
OFF OFF
1
OFF ON
2
ON OFF
3
ON ON
4
Label Type / function
i
A Input XB 53A /B5 - 36
B Output XH13/ H1 - 36B
C Input XB 53A /B5 - 37
D Output XH13/ H1 - 37B
E Input XB 53B /B5 - 31
F Output XH19A / H1 - 94
G Input XB 53B /B5 - 32
H Output XH19B / H1 - 94
5.2 Wiring of the expansion
module
5.2.1 Module overview
Flashing .......... cable break
Single flash (run light) ...scanning MSBUS
Displays
Terminals
DIP switch (I) settings
5.2.1 / 1
XB53A
XB53B
XH13
XH19A
XH19B
XW41B
I
XW41C XW41A
BX 36
I1 I2 I3 I4
37 BX 31 32
WC 41B WC 415
AB C
DEF
G
H
Manual for installation and operation, Expansion module EM 172 GB (#114684 / 1700018895) 7
5. Installation
5.2.2 Connection of the modules
• Connect the CS310/CS500 control unit to the
connecting socket XW41A.
• Connect further modules to socket XW41B as
required.
5.2.2 / 1
XW41B
Connection of the control unit and a further
module
- XB53A
B5 36 37
I1
I2
5.2.2 / 2
Connection of programmable input 1 and 2
(XB53A)
M13E028
XW41A
Label Type / function
I1
Button / switch for
programmable input 1
I2
Button / switch for
programmable input 2
Connection of programmable input 1 and 2
(XH13)
- XH13
L/+
N/-
Q1
-H1
H1 36A 36B 37A 37B
Q2
5.2.2 / 4
M13E028
Label Type / function
H1 Consumer (e.g. signal light)
L / + On-site supply voltage
L / – On-site supply voltage
Q1 Relay, programmable output 1
Q2 Relay, programmable output 2
Attention!
To avoid damage being caused to the
circuit board, the contact loading
(max. 230 V / 6 A) must be observed.
5. Installation
8 Manual for installation and operation, Expansion module EM 172 GB (#114684 / 1700018895)
Label Type / function
I3
Button / switch for
programmable input 3
I4
Button / switch for
programmable input 4
Connection of programmable input 3 and 4
(XB53B)
- XB53B
B5 3231
I3 I4
5.2.2 / 3
M13E028
Manual for installation and operation, Expansion module EM 172 GB (#114684 / 1700018895) 9
5. Installation
Connection of programmable output 4
(XH19B)
- XH19B
H1 92 94
Q4
L/+
N/-
-H1
5.2.2 / 6
M13E028
92
94
H1
Label Type / function
H1 Consumer (e.g. signal light)
L / + On-site supply voltage
L / – On-site supply voltage
Q3 Relay, programmable output 3
Label Type / function
H1 Consumer (e.g. signal light)
L / + On-site supply voltage
L / – On-site supply voltage
Q4 Relay, programmable output 4
- XH19A
L/+
N/-
-H1
H1 92 94
Q3
Connection of programmable output 3
(XH19A)
5.2.2 / 5
M13E028
92
94
H1
6. Programming
10 Manual for installation and operation, Expansion module EM 172 GB (#114684 / 1700018895)
Reference:
For instructions on programming expansion module EM 172, please refer to the
documentation provided with control CS 310/CS500.
i
Manual for installation and operation, Expansion module EM 172 GB (#114684 / 1700018895) 11
7. Appendix
Technical data
Voltage: V 24
Max. contact load, relay outputs V / A 230 / 0.5
Max. contact load, inputs No separate source voltage
Protection category IP 20
Cabling Conventional | MSBUS cable
Dimensions (WxHxD) mm 126x85x46
Internal consumption mA max. 100 (20 per relay)
Weight kg 0.25
English Original instructions, Copyright.
No part of this manual may be reproduced without our prior consent.
Subject to changes which are in the interest of technical improvements.
Valid from: 01.2014
#114684 / 1700018895
1 - GB/KD 360406 - M - 0.5 - 0114
114684
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Marantec EM 172 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI