ProTechTrader PDM-711 is a versatile digital multimeter designed for a range of electrical measurements. It offers accurate readings for DC/AC voltage, DC current, resistance, diode testing, transistor testing, continuity testing, and square wave test signal output. The device features a large 3½-digit LCD display, automatic polarity indication, and overload protection for added safety. Its compact size and lightweight design make it portable and convenient for various electrical troubleshooting and diagnostic tasks.

ProTechTrader PDM-711 is a versatile digital multimeter designed for a range of electrical measurements. It offers accurate readings for DC/AC voltage, DC current, resistance, diode testing, transistor testing, continuity testing, and square wave test signal output. The device features a large 3½-digit LCD display, automatic polarity indication, and overload protection for added safety. Its compact size and lightweight design make it portable and convenient for various electrical troubleshooting and diagnostic tasks.

- 1 - © 2019 https://www.ProTechTrader.com
User Guide
ProTechTrader
LARGE SCREEN
DIGITAL MULTIMETER
PDM-711
Please read this manual before using the
multimeter. Latest manual and more can be
found on https://www.ProTechTrader.com
- 2 - © 2019 https://www.ProTechTrader.com
Warning
To avoid possible electric shock, injury, and
damage to the Meter please follow these rules:
Before using the Meter, inspect the exterior
casing. Do not use the Meter if it is visibly
damaged or if it appears to be tampered with.
Inspect the test leads for damaged insulation or
exposed metal. Check the test leads for
continuity.
Do not apply more than the rated voltage, in any
fashion to the Meter or terminals.
The rotary switch should be placed in the correct
position before measurement and should NOT be
moved during measurement to prevent damage.
When the Meter is working at an effective voltage
over 60V in DC or 30V rms in AC take additional
care due to increased danger of electric shock.
Use the proper terminals, function, and range for
your measurements.
Do not use or store the Meter in a high-
temperature environment, do not expose to high
levels of humidity, or near strong magnetic
fields. The performance of the Meter may
deteriorate in any of these harsh environments.
Disconnect circuit power and discharge all high-
voltage capacitors before testing resistance,
continuity, diodes or hFE.
Replace the battery as soon as the battery
indicator appears. A low battery will cause
the Meter to produce inaccurate readings and
could lead to damage and dangerous conditions.
The Meter is suitable for dry location use only.
Turn the Meter power off when it is not in use
and take out the battery when not using for a
long time to avoid battery leakage and damage
- 3 - © 2019 https://www.ProTechTrader.com
Technical Specifications
Accuracies are guaranteed for 1 year, 23°C±5°C,
less than 80%RH
DC VOLTAGE
RANGE RESOLUTION ACCURACY
200mV 100uV ±(0.5% of rdg + 3D)
2000mV 1mV
20V 10mV
200V 100mV
1000V 1V ±(1.0% of rdg + 5D)
±(0.8% of rdg + 5D)
OVERLOAD PROTECTION: 220V rms AC for
200mV range and 1000V DC or 750V rms for all
ranges.
AC VOLTAGE
RANGE RESOLUTION ACCURACY
200V 100mV
750V 1V
±(2.0% of rdg +10D)
RESPONSE: Average responding, calibrated in
rms of a sine wave.
FREQUENCY RANGE: 45Hz ~ 450Hz
OVERLOAD PROTECTION: 1000V DC or 750V
rms for all ranges.
- 4 - © 2019 https://www.ProTechTrader.com
AUDIBLE CONTINUITY
RANGE DESCRIPTION
Built-in buzzer sounds if resistance is
less then 30±20Ω
OVERLOAD PROTECTION: 15 second maxi-
mum 220 V rms.
DC CURRENT
OVERLOAD PROTECTION: 500mA 250V fuse
(10A range unfused).
MEASURING VOLTAGE DROP: 200mV
RESISTANCE
±(1.0% of rdg +4D)
MAXIMUM OPEN CIRCUIT VOLTAGE: 3.0V.
OVERLOAD PROTECTION: 15 seconds maxi-
mum 220Vrms.
RANGE RESOLUTION ACCURACY
2000uA 1uA ±(1.8% of rdg +2D)
20mA 10uA ±(1.8% of rdg +2D)
200mA 100uA ±(2.0% of rdg +2D)
10A 10mA ±(2.0% of rdg +10D)
- 5 - © 2019 https://www.ProTechTrader.com
OPERATING INSTRUCTIONS
DC & AC VOLTAGE DC
1. Connect red test lead to
“VΩmAjack, Black lead to
“COMjack.
2. Set RANGE switch to
desired DC/AC VOLTAGE
position, if the voltage to be
measured is not known
beforehand, set switch to
the highest range and
reduce it until satisfactory
reading is obtained.
AC
3. Connect test leads to
device or circuit being
measured.
4. Turn on power of the
device or circuit being
measured voltage value will
appear on Digital Display along
with the voltage polarity.
- 6 - © 2019 https://www.ProTechTrader.com
DC CURRENT
1. Red lead to “VΩmA”. Black
lead to “COM (for
measurements between
200mA and 10A connect
the red lead to “10Ajack)
2. RANGE switch to desired
DCA position.
3. Connect test leads in
series with the loaded
current to be measured so
that current may flow
through the meter.
4. Read current value on Digital Display.
Please Note: The “10A
function is designed for
intermittent use only.
Maximum contact time of
the test leads with the
circuit is 10 seconds, with a
minimum 10-minute
intermission time between
tests.
- 7 - © 2019 https://www.ProTechTrader.com
RESISTANCE
1. Red lead to “VΩmA”. Black
lead to “COM”.
2. Set RANGE switch to
desired OHM position.
3. If the resistance being
measured is connected to
a circuit, turn off power
before measurement.
4. Connect test leads to
circuit being measured.
5. Read resistance value on
Digital Display.
DIODE MEASUREMENT
1. Red lead to “VΩmA”, Black
lead to “COM”.
2. Set RANGE switch to “
position.
3. Connect the red test lead to
the anode of the diode to
be measured and black
test lead to cathode.
4. The forward voltage drop in
mV will be displayed. If the
diode is reversed, figure “1”
will be shown.
- 8 - © 2019 https://www.ProTechTrader.com
TRANSISTOR (hFE)
1. Set RANGE switch to the
hFE position.
2. Determine whether the
transistor is PNP of NPN
type and locate the
Emitter, Base and
Collector leads. Insert the
leads into the proper
holes of the hFE Socket
on the front panel.
3. The meter will display the
hFE value while providing the base current
10μA and V
CE
2.8V.
CONTINUITY TEST (Beep)
1. Red lead to “VΩmA, Black
lead to “COM”.
2. Set RANGE to position.
3. Connect test leads to two
points of circuit to be
tested. If the resistance is
lower than 30Ω±20Ω, the
buzzer will sound.
- 9 - © 2019 https://www.ProTechTrader.com
SQUARE WAVE TEST SIGNAL USE
1. Set RANGE switch to “
position.
2. A test signal (50Hz)
appears between “VΩmA
and “COMjack, the output
voltage is approx 5V p-p
with 50KΩ impedance.
NOTE: OVERLOAD
PROTECTION: 15 seconds
maximum 220Vrms.
Warranty
This instrument is warranted to be free from
manufacturing defects in material and
workmanship for one year. Any instrument
found defective within one year may be
returned to the factory with transportation
charges prepaid, will be replaced or
refunded if deemed covered by the warranty
at our descension. This warranty does not
cover consumable items such as batteries or
fuses. If the defect has been caused by a
misuse or abnormal operation conditions the
warranty will be void.
- 10 - © 2019 https://www.ProTechTrader.com
General Specifications
Accuracy: LCD 3 ½ digits (2000 count)
LCD Size: 1.1in high
Polarity: Automatic – Negative indicated by “-“
Sampling speed: 2 times per second
Over-load indication: “1is displayed
Operating Environment: 0°C~40°C, at <80%RH
Storage Environment: -10°C~50°C, at <85%RH
Power: 9V NEDA 1604 or 6F22 Battery
Low battery indication: “
Static electricity: Approximately 4mA
Product Size: 129 x 70 x 29mm
Product net weight: 129g (including battery)
Battery and Fuse Replacement
Fuse will rarely need replacement. Blown fuses
are likely a result of operator error.
If appears on the display, it indicates that the
battery should be replaced.
To replace battery & Fuse (500mA/250V) remove
the 2 screws on the rear bottom of the case,
simply remove the old, and replace with a new one.
Be careful to observe the proper polarity.
Package Contents
Digital Multimeter
User Guide
Set of test leads
9-volt battery (6F22) factory installed
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

ProTechTrader PDM-711 User manual

Category
Multimeters
Type
User manual

ProTechTrader PDM-711 is a versatile digital multimeter designed for a range of electrical measurements. It offers accurate readings for DC/AC voltage, DC current, resistance, diode testing, transistor testing, continuity testing, and square wave test signal output. The device features a large 3½-digit LCD display, automatic polarity indication, and overload protection for added safety. Its compact size and lightweight design make it portable and convenient for various electrical troubleshooting and diagnostic tasks.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI