American Hearth Lincoln 26 Fireplace (VFD26FP) Owner's manual

Category
Fireplaces
Type
Owner's manual

This manual is also suitable for

UNVENTED GAS
FIREPLACE MODELS:
VFD26FM(2,3)0(W,C)(N,P)-2
VFD26FP(2,3)0L(N,P)-2
VFD26FP70L(N,P)-1
VFD26FP30L10(N,P)-3
VFD26FP70L10(N,P)-1
VENT-FREE GAS FIREPLACES
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
Do not store or use gasoline or other


WHAT TO DO IF YOU SMELL GAS
 
 

 
 


 

 


INSTALLER:

CONSUMER:
Retain this manual for future reference.
WARNING
If not installed, operated and maintained
in accordance with the manufacturer's
instructions, this product could expose you

which can cause death or serious illness.
       
    

This appliance is only for use with the type of gas in-
dicated on the rating plate. This appliance is not con-

-



WATER VAPOR: A BY-PRODUCT OF UNVENTED
ROOM HEATERS
       
     

of gas input per hour. Refer to page 8.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
Page 1
30816-11-0120Page 2
TABLE OF CONTENTS
IMPORTANT SAFETY INFORMATION ..........................................................................................3
SAFETY INFORMATION FOR USERS OF PROPANE GAS .........................................................4
INTRODUCTION ............................................................................................................................5
BUILT-IN FIREPLACE INSTALLATION ..........................................................................................6
FIREPLACE DIMENSIONS ............................................................................................................7
SPECIFICATIONS ..........................................................................................................................8
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS ........................................8
PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR ...................................9-10
CONNECTING THE GAS ............................................................................................................10
GAS SUPPLY ............................................................................................................................... 11
CLEARANCES .............................................................................................................................12
COMBUSTIBLE MATERIAL ......................................................................................................... 12
INSTALLATION OF FIREPLACE AND MANTEL ....................................................................13-14
OUTER TRIM INSTRUCTIONS ...................................................................................................15
HOOD INSTRUCTIONS ...............................................................................................................15
LOG PLACEMENT ....................................................................................................................... 16
PLACEMENT OF GLOWING EMBERS (ROCK WOOL) .............................................................17
OPERATION INSTRUCTIONS/FLAME APPEARANCE .............................................................. 18
MAINTENANCE ...........................................................................................................................18
10,000 BTU MILLIVOLT LIGHTING INSTRUCTIONS .................................................................19
MILLIVOLT LIGHTING INSTRUCTIONS .....................................................................................20
INTERMITTENT PILOT LIGHTING INSTRUCTIONS ..................................................................21
HYDRAULIC THERMOSTAT LIGHTING INSTRUCTIONS .........................................................22
PILOT FLAME CHARACTERISTICS ......................................................................................23-24
MAIN BURNER AND THERMOSTAT OPERATION .....................................................................25
MILLIVOLT WIRING .....................................................................................................................26
MILLIVOLT TROUBLESHOOTING ..............................................................................................27
IP ELECTRONIC SYSTEM OPERATING INSTRUCTIONS ........................................................28
IP ELECTRONIC SYSTEM WIRING DIAGRAM .......................................................................... 29
INTERMITTENT CONTROL SYSTEM TROUBLESHOOTING ...............................................30-32
JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS ......................................................33
PARTS LIST ............................................................................................................................34-35
PARTS VIEW ...............................................................................................................................36
FBBX BLOWER KIT EXTENSION INSTALLATION INSTRUCTIONS ....................................37-38
FBB4 OPTIONAL VARIABLE SPEED BLOWER .........................................................................38
FPP26E OPTIONAL BRICK LINER KIT INSTALLATION INSTRUCTIONS .................................39
MASTER PARTS DISTRIBUTOR LIST ........................................................................................ 40
HOW TO ORDER REPAIR PARTS ..............................................................................................40
WARRANTY .................................................................................................................................41
APPLIANCE SERVICE HISTORY ...........................................................................................42-43
SECTION PAGE
30816-11-0120 Page 3
IMPORTANT SAFETY INFORMATION
THIS IS A HEATING APPLIANCE
DANGER: Indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING: Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
NOTICE: Addresses practices not related to personal injury.
 

 

 

 
         
ignition.
 
the same room with the appliance.
 
appliance.
           
fresheners, etc. ) while the log set is in operation. Air fresheners
produce a residue in the air similar to candles and may produce

 
set is in operation. Candles produce a residue in the air that




of soot produced and deposited.
  QUALIFIED SERVICE
PERSON. 





 

room heater and to replace any part of the control system and

 
 
operation.
      



off during initial operation of the appliance. This is a normal


 

      
installation or operation, can settle on surfaces outside the


         






        



WARNING: DO NOT operate this appliance unless all



Log set placement instructions for correct log and twig
positioning.
      
dealer as indicated in the How to Order Repair Parts section of
the appliance manual.
 




WARNING

-
ous gas.
        
-


of instructions, refer to the National Fuel Gas Code, ANSI
      

PILOT LIGHT SAFETY SYS-
TEM designed to turn off the heater if not enough fresh air

DO NOT TAMPER WITH PILOT LIGHT SAFETY SYSTEM!


control compartment clean.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH.

        
Get fresh air at

Some people — pregnant women, persons with heart or lung

         
than others.
The pilot light safety system senses the depletion of oxygen



In this type of application, a fan to circulate the structure air will




30816-11-0120Page 4
-
sions. In its natural state, propane is odorless and colorless.





exactly what to do. If, after reading the following information,
you feel you still need more information, please contact your
gas supplier.
SOME POINTS TO REMEMBER
• Your local
Propane Gas Dealer can give you a "Scratch and Sniff"
pamphlet.Useittondoutwhatthepropaneodorsmells
like. If you suspect that your Propane Gas has a weak or
abnormal odor, call your Propane Gas Dealer.
• If you are not qualied, do not light pilot lights, perform
service, or make adjustments to appliances on the Propane
Gassystem.Ifyouarequalied,consciouslythinkaboutthe
odor of Propane Gas prior to and while lighting pilot lights
or performing service or making adjustments.
• Sometimesabasementoraclosed-uphousehasamusty
smell that can cover up the Propane Gas odor. Do not try
to light pilot lights, perform service, or make adjustments
in an area where the conditions are such that you may not
detect the odor if there has been a leak of Propane Gas.
• Odorfade,duetooxidationbyrustoradsorptiononwalls
of new cylinders and tanks, is possible. Therefore, people
should be particularly alert and careful when new tanks or
cylinders are placed in service. Odor fade can occur in new
tanks,orreinstalledoldtanks,iftheyarelledandallowed
tosettoolongbeforerelling.Cylindersandtankswhich
have been out of service for a time may develop internal
rust which will cause odor fade. If such conditions are sus-
pectedtoexist,aperiodicsnifftestofthegasisadvisable.

Propane Gas Dealer. A periodic sniff test of the Propane
Gas is a good safety measure under any condition.
• If,atanytime,youdonotsmellthePropaneGasodorant
and you think you should, assume you have a leak. Then
take the same immediate action recommended above for
the occasion when you do detect the odorized Propane Gas.
• Ifyouexperienceacomplete"gas out,"(the containeris
under no vapor pressure), turn the tank valve off immediately.
If the container valve is left on, the container may draw in
someairthroughopeningssuchaspilotlightorices.Ifthis
occurs, some new internal rusting could occur. If the valve
is left open, then treat the container as a new tank. Always
be sure your container is under vapor pressure by turning
it off at the container before it goes completely empty or
havingitrelledbeforeitiscompletelyempty.
NO ODOR DETECTED - ODOR FADE
Some people cannot smell well. Some people cannot smell

out if you can smell the odorant in propane. Smoking can
decrease your ability to smell. Being around an odor for a time
can affect your sensitivity or ability to detect that odor. Some-
times other odors in the area mask the gas odor. People may
not smell the gas odor or their minds are on something else.
Thinking about smelling a gas odor can make it easier to smell.
The odorant in Propane Gas is colorless, and it can fade
under some circumstances. For example, if there is an
underground leak, the movement of the gas through soil can
ltertheodorant.OdorantsinPropaneGasalsoaresubject
tooxidation.Thisfadingcanoccurifthereisrustinsidethe
storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or
into walls, masonry and other materials and fabrics in a room.
That will take some of the odorant out of the gas, reducing its
odor intensity.
Propane Gas may stratify in a closed area, and the odor inten-
sity could vary at different levels. Since it is heavier than air,
there may be more odor at lower levels. Always be sensitive
to the slightest gas odor. If you detect any odor, treat it as a
serious leak. Immediately go into action as instructed earlier.
PROPANE GAS WARNING ODOR

That's your signal to go into immediate action!
• Donotoperateelectricswitches,lightmatches,useyour
phone. Do not do anything that could ignite the gas.
• Geteveryoneoutofthebuilding,vehicle,trailer,orarea.
Do that IMMEDIATELY.
• Closeallgastankorcylindersupplyvalves.
• PropaneGasisheavierthanairandmaysettleinlowareas
such as basements. When you have reason to suspect
a gas leak, keep out of basements and other low areas.
Stayoutuntilreghtersdeclarethemtobesafe.
• Use your neighbor's phone and call a trained Propane
Gasservicepersonandtheredepartment.Eventhough
you may not continue to smell gas, do not turn on the gas
again. Do not re-enter the building, vehicle, trailer, or area.
• Finally,lettheservicemanandreghterscheckfores-
caped gas. Have them air out the area before you return.
Properly trained Propane Gas service people should repair
the leak, then check and relight the gas appliance for you.
SAFETY INFORMATION FOR USERS OF PROPANE GAS
30816-11-0120 Page 5
Important
All correspondence should refer to complete Model Number, Serial
Number and type of gas.
Attention: During initial use of ceramic log you will detect an
odor as the ceramic log cures.
Notice:Duringinitialring,itspaintwillbakeoutcausingsmoke.
To prevent triggering of smoke alarms, ventilate the room in which
the unit is installed.
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other
combustiblematerialotherthanwoodooringtheapplianceshall
beinstalledonametalorwoodpanelextendingthefullwidthand
depth of the appliance.
Thebasereferredtoabovedoesnotmeanthere-proofbaseas
usedonwoodstoves.Theprotectionisforrugsthatareextremely
thick and light colored tile.
Solid-fuels shall not be burned in a masonry or UL 127 factory-
builtreplaceinwhichanunventedroomheaterisinstalled.

Installationandreplacement of gas piping, gasutilizationequip-
mentoraccessoriesandrepairandservicingofequipmentshall
be performed only by a qualied agency. The term "qualied
agency"meansanyindividual,rm,corporationorcompanywhich
either in person or through a representative is engaged in and is
responsible for (a) the installation or replacement of gas piping or
(b)theconnection,installation,repairorservicingofequipment,who
isexperiencedinsuchwork,familiarwithallprecautionsrequired
andhascompliedwithalltherequirementsoftheauthorityhaving
jurisdiction.
Commonwealth of Massachusetts: The installation must be
madebyalicensedplumberorgastterintheCommonwealth
of Massachusetts.
Sellersofunventedpropaneornaturalgas-redsupplemental
room heaters shall provide to each purchaser a copy of 527 CMR
30 upon sale of the unit.
In the Commonwealth of Massachusetts, unvented propane and
naturalgas-redspaceheatersshallbeprohibitedinbedrooms
and bathrooms.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1.*
*Available from the American National Standards Institute, Inc. 1430
Broadway, New York, N.Y. 10018.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), ratings should be
reduced at the rate of 4 percent for each 1,000 feet (305m) above
sea level. Contact the manufacturer or your gas company before
changingspud/oricesize.
WARNING

clean may result in sooting and property damage.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installermusthaveownerlloutandmailwarrantycardsupplied
with unvented room heater.
3. Installer should show owner how to start and operate unvented
room heater.
Always consult your local Building Department regarding regula-
tions, codes or ordinances which apply to the installation of an
unvented room heater.
This appliance may be installed in an aftermarket* manufactured
(mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.
Well Head Gas Installations
Some natural gas utilities use “well head” gas. This may affect
the Btu output of the unit and promote sooting. Units shall not be
converted to use well head gas.
This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases.
WARNING

Improper installation or use of the heater can cause seri-
         
monoxide poisoning.
Operation
Thisunventedreplacerequiresnooutsideventing.Stateandlocal
codesinsomeareasprohibittheuseofunventedreplace.

The valve regulator controls the burner pressure which should be
checked at the pressure test point. Turn captured screw counter
clockwise 2 or 3 turns and then place tubing to pressure gauge over
test point (Use test point “A” closest to control knob). After taking
pressurereading,besureandturncapturedscrewclockwisermly
tore-seal.Donotovertorque.Checkforgasleaks.

When you ignite the pilot, the thermocouple produces millivolts
(electrical current) which energizes the magnet in the gas valve. After
30 seconds to 1 minute time period you can release the gas control
knobandthepilotwillstayON.Allowyourpilotametooperate
an additional one to two minutes before you turn the gas control
knob from the PILOT position to the ON position. This time period
allows the millivolts (electrical current)to build-up to a sufcient
level allowing the gas control to operate properly.
WARNING


General Information
ThisseriesisdesigncertiedinaccordancewithAmericanNational
Standard Z21.11.2 by the Canadian Standards Association as an
Unvented Room Heater and should be installed according to these
instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not


INTRODUCTION
30816-11-0120Page 6
BUILT-IN FIREPLACE INSTALLATION
Built-In Fireplace Installation
Built-ininstallationofthisreplaceinvolvesinstallingthereplace
intoa framed-inenclosure.Thismakes thefront ofthereplace
ush with a wall. If installing a mantel above the replace, you
must follow the clearances shown in Figure 9. Follow the instruc-
tionsbelowtoinstallthereplaceinthismanner.
Frame in rough opening. Use dimensions show in Figure 1 for a
conventional rough opening. Use dimensions shown in Figure 2
forcornerroughopening.Besuretoprovidegaslineforreplace
and electrical power for optional blower assembly.
1. Attachtwonailingangestoreboxsideswithtwo10x1/2"
screwsforeachnailingange.
2. Gas line connections must be made at this time. When facing
the appliance, the gas supply will enter on the right-hand side.
See "Gas Supply" page 11.
3. Insertreplaceintoenclosure.
4. Attachnailingangestoframingwithascrewornail.
5. Finishedwallsurfacewillbeushtotheleadingedgeofre-
place top and sides.
6. Installationofbuilt-inreplaceiscompleted.
Figure 2
Figure 1
Rough Opening for Installing in Wall
Rough Opening for Installing in Corner
Figure 3
USE ONLY
THE (4)
SIDE NAILING
FLANGES
FOR BUILT-IN
INSTALLATION
30816-11-0120 Page 7
FIREPLACE DIMENSIONS
GAS LINE
OPENING
JUNCTION BOX
ASSEMBLY
GAS
LINE
OPENING
J
I
K
B
C
G
A
D
E
Figure 4
VFD26 SERIES DIMENSIONS
Index Letter Dimension
A
30 1/4"
768mm
B
30"
762mm
C
13 1/8"
333mm
D
18 1/8"
460mm
E
26"
660mm
G
25"
635mm
I
36 1/4"
921mm
J
36 1/4"
921mm
K
51 1/4"
1302mm
30816-11-0120Page 8
SPECIFICATIONS
MODEL VFD26F(M,P)(3,7) VFD26F(M,P)2 VFD26FP(3,7)0L10
InputMaximum 20,000 20,000 10,000
Minimum 14,000 14,000 N/A
NATURAL
Orice 2.10 mm (P-288) #49 (.073") P-265 #53 (.0595") P-214
Air Shutter Opening 1/8" 1/8" 1/8"
PROPANE
Orice #55 (.052") P-182 #55 (.052") P-182 #64 (.036") P-193
Air Shutter Opening 1/4" 1/4" 1/4"
FIREPLACE DIMENSIONS
Height 30 1/4" 30 1/4" 30 1/4"
Depth 13 1/8" 13 1/8" 13 1/8"
Front Width 30" 30" 30"
Rear Width 25" 25" 25"
Gas Inlet 3/8" 3/8" 3/8"
ACCESSORIES
Model Description
FBBX BlowerExtensionKit(MUSTorderFBB4)
FBB4 Automatic Blower (MUST order FBBX)
VPS26HP Bottom Trim Kit
VP2H26HP Hammered Pewter Hood Kit
VPF26HP Hammered Pewter Trim Kit
FPP26E Brick Liner
VPL26HP Hammered Pewter Slat Louver
ACCESSORIES FOR MILLIVOLT VFD26F(M,P)(3,7) ONLY
FRBC Battery Operated Remote Control
FRBTC Battery Operated Remote Control w/Thermostat
FREC Electric Remote Control
FWS-1 Wall Switch
TMV Wall Thermostat, Millivolt - Reed Switch
TRW Wireless Remote Wall Thermostat
Water vapor is a by-product of gas combustion. An unvented room
heaterproducesapproximatelyoneounce(30ml)ofwaterforevery
1,000BTU's(.3KW's)ofgasinputperhour..
Unvented room heaters are recommended as supplemental heat (a
room) rather than a primary heat source (an entire house). In most
supplemental heat applications, the water vapor does not create a
problem. In most applications, the water vapor enhances the low
humidityatmosphereexperiencedduringcoldweather.
The following steps will help insure that water vapor does not
become a problem.
1. Be sure the heater is sized properly for the application, including
ample combustion air and circulation air.
2. Ifhighhumidityisexperienced,adehumidiermaybeusedto
help lower the water vapor content of the air.
3. Do not use an unvented room heater as the primary heat source.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
30816-11-0120 Page 9
3. Add the BTU/Hr of all fuel burning appliances in the space.
Vent-free heater
BTU/Hr
Gas water heater
BTU/Hr
Gas furnace BTU/Hr
Vented gas heater BTU/Hr
Gasreplacelogs BTU/Hr
Other gas appliances* + BTU/Hr
Total = BTU/Hr
Example: Ventedgasheater 20,000 BTU/Hr
Vent-free heater + 18,000 BTU/Hr
Total = 38,000 BTU/Hr
*Do not include direct-vent gas appliances. Direct vent draws
combustion air from the outdoors and vents to the outdoors.
4. ComparethemaximumBTU/Hrthespacecansupportwiththe
actual amount of BTU/Hr used.
BTU/Hr(maximumthespacecansupport)
BTU/Hr (actual amount of BTU/Hr used)
Example:
25,600 BTU/Hr(maximumthespacecansupport)
38,000 BTU/Hr (actual amount of BTU/Hr used)
WARNING



         
the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for

Thespaceintheaboveexampleisaconnedspacebecausethe
actualBTU/HrusedismorethanthemaximumBTU/HRthespace
can support. You must provide additional fresh air. Your options
are as follows:
A. Rework worksheet, adding the space of an adjoining room. If
theextraspaceprovidesanunconnedspace,removedoor
to adjoining room or add ventilation grills between rooms. See
Ventilation Air From Inside Building.
B. Vent room directly to the outdoors. See Ventilation Air From
Outdoors.
C. Install a lower BTU/Hr heater, if lower BTU/Hr size makes room
unconned.
IftheactualBTU/HrusedislessthanthemaximumBTU/Hrthe
spacecansupport,thespaceisanunconnedspace.Youwillneed
no additional fresh air ventilation.
WARNING

space.
Thisheatershall not be installed in a conned space or unusu-
allytightconstructionunlessprovisionsareprovidedforadequate
combustion and ventilation air.
Aconnedspaceisanareawithvolumelessthan50cubicfeetper
1,000 Btuh of the combined input rates of all appliances drawing
combustionairfromthatspace.Smallareassuchasequipment
roomsareconnedspaces.Furnacesinstalledinaconnedspace
which supply heated air to areas outside the space must draw return
air from outside the space through tightly sealed return air ducts. A
connedspacemusthave2openingsintothespaceforcombus-
tion air. One opening must be within 12 inches of the ceiling and
theothermustbewithin12inchesoftheoor.Therequiredsizing
of these openings is determined by whether inside or outside air is
used to support combustion, the method by which the air is brought
to the space (vertical or horizontal duct) and by the total input rate
of all appliances in the space.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough
fresh air for combustion and ventilation. However, in buildings of
unusually tight construction, you must provide additional fresh air.
      
where:
a. Wallsandceilingsexposedtotheoutsideatmospherehave
a continuous water vapor retarder with a rating of one perm
or less with openings gasketed or sealed, and
b. Weatherstripping has been added on openable windows and
doors, and
c. Caulking or sealants are applied to areas such as joints
around window and door frames, between sole plates and
oors,betweenwall-ceilingjoints,betweenwallpanels,at
penetrations for plumbing, electrical, and gas lines, and at
other openings.
If your home meets all of the three criteria above, you must provide
additional fresh air. See “Ventilation Air From Outdoors,” page
10.

Usethisworksheettodetermineifyouhaveaconnedorunconned
space.
Space: Includes the room in which you will install heater plus any
adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1.Determinethevolumeofthespace(lengthxwidthxheight).
LengthxWidthxHeight=
cu. ft. (volume of
space)
Example:Spacesize16ft.(length)x10ft.(width)x8ft.(ceiling
height) = 1,280 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills
or openings, add the volume of these rooms to the total volume
of the space.
2. Divide the space volume by 50 cubic feet to determine the
maximumBTU/Hrthespacecansupport.
(volumeofspace)÷50cu.ft.= (maximum
BTU/Hr the space can support)
Example:1,280cu.ft.(volumeofspace)÷50cu.ft.=25.6or
25,600(maximumBTU/Hrthespacecansupport)
PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR
30816-11-0120Page 10
VENTILATION AIR
Ventilation Air From Inside Building
Thisfreshairwouldcomefromanadjoiningunconnedspace.When
ventilatingtoanadjoiningunconnedspace,youmustprovidetwo
permanent openings: one within 12" of the ceiling and one within
12"oftheooronthewallconnectingthetwospaces(seeoptions
1 and 2, Figure 5). You can also remove door into adjoining room
(see option 3, Figure 5). Each ventilation grill or opening shall have
aminimumfreeareaofonesquareinchper1,000BTU/HRofthe
totalinputratingofthegasequipmentintheconnedspace.
Figure 5
WARNING
       


Ventilation Air From Outdoors
Provideextrafreshairbyusingventilationgrillsorducts.Youmust
provide two permanent openings: one within 12" of the ceiling and
onewith12"oftheoor.Connecttheseitemsdirectlytotheoutdoors
or spaces open to the outdoors. These spaces include attics and
crawl spaces. In most cases for direct communication with the
outdoors or direct communication through a vertical duct a free
areaopeningofonesquareinchper4,000BTU/HRofheaterinput
rating for each grill. If a horizontal duct is used, a grill free area or
ductopeningshallhaveafreeareaopeningofonesquareinchper
2,000 BTU/HR for each grill. Follow the National Fuel Code, ANSI
Z223.1/NFPA 54, Air for Combustion and Ventilation, or applicable
local codes,forrequiredsizeofventilationgrillsorducts.
IMPORTANT: Do not provide openings for inlet or outlet air into attic
if attic has a thermostat-controlled power vent. Heated air entering
the attic will activate the power vent.
Figure 6
PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR
CONNECTING THE GAS
The inlet connection is located on the right side of the gas valve.
Attach gas inlet line to gas valve.
If installing the an Optional Blower, it must be installed before
connecting the gas line.
30816-11-0120 Page 11
Checkalllocalcodesforrequirements,especiallyforthesizeand
typeofgassupplylinerequired.
RECOMMENDED GAS PIPE DIAMETER
Pipe
Length
Schedule 40 Pipe
Inside Diameter

Outside Diameter
Natural Propane Natural Propane
0-10 feet
0-3 meters
1/2”
12.7mm
3/8”
9.5mm
1/2”
12.7mm
3/8”
9.5mm
10-40 feet
4-12 meters
1/2”
12.7mm
1/2”
12.7mm
5/8”
15.9mm
1/2”
12.7mm
40-100 feet
13-30 meters
1/2”
12.7mm
1/2”
12.7mm
3/4”
19mm
1/2”
12.7mm
100-150 feet
31-46 meters
3/4”
19mm
1/2”
12.7mm
7/8”
22.2mm
3/4”
19mm
NOTICE: Neveruseplasticpipe.Checktoconrmwhetheryour
local codes allow copper tubing or galvanized.
NOTICE: Since some municipalities have additional local codes, it is
always best to consult your local authority and installation code.
Installing a New Main Gas Shut-Off
Each appliance should have its own manual gas shut-off.
A manual main gas shut-off should be located in the vicinity of the
unit.Wherenoneexists,orwhereitssizeorlocationisnotadequate,
contact your local authorized installer for installation or relocation.
Compounds used on threaded joints of gas piping shall be resistant
totheactionofliqueedpetroleumgases.Thegaslinesmustbe
checked for leaks by the installer. This should be done with a soap
solutionwatchingforbubblesonallexposedconnections,andif
unexposed,apressuretestshouldbemade.
WARNING




A gas valve and ground joint union should be installed in the gas
lineupstreamofthegascontroltoaidinservicing.Itisrequiredby
the National Fuel Gas Code that a drip line be installed near the gas
inlet. This should consist of a vertical length of pipe tee connected
into the gas line that is capped on the bottom in which condensation
and foreign particles may collect.
The use of the following gas connectors is recommended:
ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing
and Fittings
— ANSZ21.45AssembledFlexibleApplianceConnectorsofOther
Than All-Metal Construction
The above connectors may be used if acceptable by the authority
havingjurisdiction.TheCommonwealthofMassachusettsrequires
thataexibleapplianceconnectorcannotexceedthreefeetinlength.
Pressure Testing of the Gas Supply System
1. To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T.
plugged tapping, accessible for test gauge connection, must
be placed immediately upstream of the gas supply connection
to the appliance.
2. The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during any
pressuretestingofthatsystemattestpressuresinexcessof
1/2 psig (3.5 kPa).
3. The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressuresequaltoorlessthan1/2psig(3.5kPa).
Figure 7
WARNING




   will have a manifold pressure of
approximately3.5"w.c.(.871kPa)formaximuminputor1.7"w.c.
(.423kPa) for minimum input at the pressure regulator outlet with
the inlet pressure to the pressure regulator from a minimum of 5.0"
w.c.(1.120kPa)forthepurposeofinputadjustmenttoamaximum
of 10.5" w.c. (2.614kPa).
2 Series Hydraulic Thermostat Natural Gas will have a manifold
pressure of approximately 6.0" w.c. (1.49kPa) at the pressure
regulator outlet with the inlet pressure to the pressure regulator
from a minimum of 7.0" w.c. (1.74kPa) for the purpose of input
adjustmenttoamaximumof10.5"w.c.(2.615kPa).
     will have a manifold pressure
approximately 10.0"w.c. (2.49kPa) for maximum input or
6.3"w.c. (1.568kPa) for minimum input at the pressure regulator
outlet with the inlet pressure to the pressure regulator from
a minimum of 11.0"w.c. (2.739kPa) for the purpose of input
adjustmenttoamaximumof13.0"w.c.(3.237kPa).
2 Series Hydraulic Thermostat Propane Gas will have a manifold
pressureapproximately10.0"w.c.(2.49kPa)atthepressureregulator
outlet with the inlet pressure to the pressure regulator from a minimum
of 11.0"w.c. (2.739kPa) for the purpose of input adjustment to a
maximumof13.0"w.c.(3.237kPa).
GAS SUPPLY
30816-11-0120Page 12
Minimum Wall and Ceiling Clearances
36”
(91.44 cm)
2” (5.08 cm)
Figure 8
         

When facing the front of the appliance the minimum clearances to
combustible construction (material) are the following:
1. Clearancesfromtherightsideorleftsideofthereplaceopening
to any combustible wall or material should not be less than 2
inches.
2. Clearancesfromthetopofthereplaceopeningtotheceiling
should not be less than 36 inches.
Mantel Clearances for Built-in Installation

Donotattachcombustiblematerialtothemantelofyourreplace.
Thisisarehazard.
HEAT
FLOW
Figure 10
No greeting cards, stockings or ornamentation of any type should be
placedonorattachedtothereplace.Thisisaheatingappliance.
Theowofheatcanignitecombustibles.
Figure 11
CLEARANCES
COMBUSTIBLE MATERIAL
COMBUSTIBLES
ALLOWED
4”
(10.2cm)
(14.0cm)
(63.0cm)
4 3/4”
(12.1cm)
6”
(15.2cm)
8 3/4”
(22.2cm)
8”
(20.3cm)
(24.1cm)
10”
(25.4cm)
10 1/4”
(26.0cm)
12”
(30.5cm)
11
(27.9cm)
TOPOF FRAME
0
MANTEL
1. Removereplacefromcarton.
2. Remove mantel top and front base from mantel assembly.
3. Removescrewattachedtoreplacetopandthrough
"L Bracket" attached to back of breast board.
4. Removemantelassemblyfromreplace.
5. Removeshrinkwrapandlogsfromreplace.
6. Placebackbaseandreplaceindesiredlocation.
7. Connect gas line and electrical wiring at this time in accor-
dance with local codes.
ELECTRICAL
CONNECTION
OPENING
GAS LINE
CONNECTION
OPENING
8. Placemantelassemblyaroundreplaceandcenter.Replace
thescrewremovedinstep3tosecurereplacetomantel
assembly.
30816-11-0120 Page 13
INSTALLATION OF FIREPLACE AND MANTEL
11. Place mantel top onto mantel assembly.
12. Install outer trim. See Page 15.
13. InstallberlogspertheLogPlacementInstructions.See
Page 16.
14. Install hood. See Page 15.
9. Attach mantel assembly to studs in the wall through the
"back brace" using two 3" drywall screws provided.
10. Slide front base under front of mantel assembly.
30816-11-0120Page 14
INSTALLATION OF FIREPLACE AND MANTEL
30816-11-0120 Page 15
OUTER TRIM INSTRUCTIONS
1. Remove upper louver, grasp louver at left and right ends; lift and pull forward.
2. Open bottom louver, then lift to remove.
3. Installtherightframeandleftframetothereplace.Alignclearanceholesinframewithscrewholesinreplace.Attachrightframe
andleftframetoreplace.Usetwo8x1/2”Phillipsscrewsforeachframe.
4. Inserttopframeintointerior,topofreplace.Alignclearanceholesintopframewithscrewholesinreplace.Attachtopframeto
replace.Usetwo8x1/2”Phillipsscrewsfortopframe.
5. Replace bottom louver.
6. Replace top louver.
3-PIECE FRAME KIT
SIDE TRIM
HOOD INSTRUCTIONS
1. Remove upper louver, grasp louver at left and right ends; lift and pull forward.
2. Remove screen frame assembly.
3. Outer trim must be installed before installing hood.
4. Placethetophoodangeontopoftherebox,theninstallonescrew(A)atthecenteronventfreereplacethroughthereboxtop
from below.
5. Install one screw (B) at each end of the hood as shown.
6. Replace upper louver.
7. Replace screen frame assembly.
CAUTION

30816-11-0120Page 16
LOG PLACEMENT
1. Placefrontlogs(#1and#2)betweenfrontgrateangeand
main burner. Align notches on front logs with locator tabs in
base.
2. Place middle log (#3) between front and rear loop of burner.
NOTICE: Do not place log on top of pilot assembly.
3. Placerearlog(#4)onrearlogshelf.Bottomangeoflogmust
be placed between the log shelf and burner tube.
4. This step is optional for VFD26FP3L10 log sets. Place front
twig(#5)onto(#1)logandatareaon(#3)log.Thebottom
of the front twig is to be placed behind the grate tang that is
second from the left.
Attention: Do not use Figures 12 and 13 to order logs. Refer to
Pages 34 to 35, Parts list and Page 36, Parts View to order logs.
Refer to Figure 12 for the following warning.
CAUTION
Failure to position the parts in accordance with this diagram
    
heater may result in property damage or personal injury.
Figure 12
1
4
5
3
2
Figure 13
30816-11-0120 Page 17
Provided with the log set is a small bag of glowing embers (rock
wool)tobeplacedbetweenlogsontheatmetalsurfaceofthe
burner.
Placement of the embers (rock wool) is very individual and light
coverage of the areas indicated will provide your best effects. We
recommend separation of the rock wool by hand and make your
coverageaslightanduffyaspossible.
Place just enough embers (rock wool) on the burner to obtain the
glowandagoldyellowame.
Do not place rock wool over large ports in rear portion of burner.
A thin layer of rock wool should be placed under open space
between the front and middle logs.
Rock wool should not be placed in the area of the pilot assembly.
Glowing embers (rock wool) can cover the burner in between
the front and middle logs, but very little is necessary to cover this
area.Excessembermaterialcausestheyellowametobecome
orange and stringy. Apply just enough to obtain slow glow and a
gold,yellowame.
Replacement of loose material (glowing embers) must be purchased
from Empire Comfort Systems, Inc.Application of excess loose
material (glowing embers) may adversely affect performance of
the heater.
WARNING

to reapplication.
Refer to Parts List, Pages 34 to 35 to order loose material (rock wool).
NOTICE: A single layer of embers is to be used when applying
Platinum Bright Embers (alone or in combination with production
embers) to the burner.
Replacement Loose Material


Rock Wool 15998
Platinum Bright Embers PE-20-1

Figure 14
30816-11-0120Page 18
Flames from the pilot (rear right back side of the burner) as well
as the main ame should be visually checked as the log set is
installed.
Innormaloperationatfullrateafter10to15minutes,theame
appearanceshouldbesetsofyellowames.
NOTICE:Allameswillberandombydesign,ameheightwillgo
up and down.
Avoidanydraftsthatalterburneramepatterns.Donotallowfansto
blowdirectlyintoreplace.Donotplaceablowerinsidetheburner
areaoftherebox.Ceilingfansmaycreatedraftsthatalterame
patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components
ofthisappliancearetreatedwithcertainoils,lmsorbondingagents.
These chemicals are not harmful, but may produce annoying smoke
and smells as they are burned off during the initial operation of the
appliance, possibly causing headaches or eye or lung irritation. This
is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner
at the highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in will be slight and will disappear with
continued use.
PERIODIC CLEANING – Refer to parts diagram for location of

• Donotusecleaninguidtocleanlogsoranypartofheater.
• Logs - brush with soft bristle brush or vacuum with brush
attachment.
• Removeloose particles and dust from the burner areas,
controls, piezo covers and grate.
• Inspectandcleanburnerairintakehole.Removelintorparticles
with brush. Failure to keep air intake hole clean will result in
sooting and poor combustion.
ANNUAL CLEANING/INSPECTION – Refer to parts diagram for

• Inspectandcleanburnerairintakehole.Removelintorparticles
with vacuum or brush. Failure to keep air intake hole clean will
result in sooting and poor combustion.
• Inspectandcleanallburnerports.
• InspectODSpilotforoperationandaccumulationoflintatair
intake holes.
• Verifyamepatternandlogplacementforproperoperation.
• Verifysmoothandresponsiveignitionofmainburner.
OPERATION INSTRUCTIONS/FLAME APPEARANCE
Keep the control compartment, logs and burner area surrounding
the logs clean by vacuuming or brushing area at least twice a year.
WARNING

Always turn off gas to the pilot before cleaning. For relighting, refer
to lighting instructions located on the rating plate of the log set.
Neverobstructtheowofthecombustionandventilationair.Keep
thefrontofthereplaceclearofallobstaclesandmaterials.
Leaveatleast36"clearancefromthefrontofthereplace.
Screen should be closed during operation.
MAINTENANCE
30816-11-0120 Page 19
          
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING, smell all around the appliance area


WHAT TO DO IF YOU SMELL GAS
 
 

 
phone. Follow the gas supplier's instructions.
     
department.
C. Use only your hand to push in or turn the gas control
           


or explosion.
 

the appliance and to replace any part of the control system

1. Open bottom louver assembly (if applicable).
2. Set REMOTE/OFF/ON switch to "OFF."
3. Turn off all electric power to the appliance if service is to be
performed (if applicable).
4. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
5. Close bottom louver assembly (if applicable).
1. STOP! Read the safety information above on this page.
2. Open bottom louver assembly (if applicable).
3. Set REMOTE/OFF/ON switch to
"OFF".
4. Turn off all electric power to the
appliance (if applicable).
5. Push in gas control knob slightly
and turn clockwise
to "OFF".
NOTE: Knob cannot be turned from "PILOT"
to "OFF" unless knob is pushed in slightly.
Do not force.
6. Wait ten minutes to clear out any gas. Then
smell for gas, including near the
oor.Ifyousmellgas,STOP!Fol-
low "B" in the safety information
above. If you do not smell gas, go
tothenextstep.
7. Find pilot - Follow metal tube from
gas control. The pilot is located
next to theburner, nearthe right
side.
8. Turn gas control knob counterclockwise
to "PILOT".
9. Push in control knob all the way and hold in. Repeatedly push
the Piezo Ignitor Button until the pilot is lit. Continue to hold
the control knob in for about one minute after the pilot is lit.
Release knob, and it will pop back up. Pilot should remain lit.
If it goes out, repeat steps 5 through 9.
• Ifknobdoesnotpopupwhenreleased,STOPandIM-
MEDIATELY call a qualied service technician or gas
supplier.
• Ifthepilotwillnotstaylitafterseveraltries,turnthegas
control knob to "OFF" and call your service technician or
gas supplier.
10. Turn gas control knob counterclockwise to "ON".
11. Set REMOTE/OFF/ON switch to desired setting.
12. Turn on all electric power to the appliance (if applicable).
13. Close bottom louver assembly (if applicable).
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
THERMOCOUPLE
(NATURAL)
ELECTRODE
PILOT
THERMOPILE
REMOTE
OFF
ON
THERMOCOUPLE
(LPG)
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
THERMOCOUPLE
(NATURAL)
ELECTRODE
PILOT
THERMOPILE
REMOTE
OFF
ON
THERMOCOUPLE
(LPG)
10,000 BTU MILLIVOLT LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
WARNING

personal injury or loss of life.
30816-11-0120Page 20
MILLIVOLT LIGHTING INSTRUCTIONS
          
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING, smell all around the appliance area


WHAT TO DO IF YOU SMELL GAS
 
 

 
phone. Follow the gas supplier's instructions.
     
department.
C. Use only your hand to push in or turn the gas control
           


or explosion.
 

the appliance and to replace any part of the control system

1. Open bottom louver assembly (if applicable).
2. Set REMOTE/OFF/ON switch to "OFF."
3. Turn off all electric power to the appliance if service is to be
performed (if applicable).
4. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
5. Close bottom louver assembly (if applicable).
1. STOP! Read the safety information above on this page.
2. Open bottom louver assembly (if applicable).
3. Set REMOTE/OFF/ON switch to
"OFF".
4. Turn off all electric power to the
appliance (if applicable).
5. Push in gas control knob slightly
and turn clockwise
to
"OFF".
NOTE: Knob cannot be turned from "PILOT"
to "OFF" unless knob is pushed in slightly.
Do not force.
6. Wait ten minutes to clear out any
gas. Then smell for gas, including
near the oor. If you smell gas,
STOP! Follow "B" in the safety
information above. If you do not
smellgas,gotothenextstep.
7. Find pilot - Follow metal tube from
gas control. The pilot is located
next to theburner, nearthe right
side.
8. Turn gas control knob counterclockwise
to "PILOT".
9. Push in control knob all the way and hold in. Repeatedly push
the Piezo Ignitor Button until the pilot is lit. Continue to hold
the control knob in for about one minute after the pilot is lit.
Release knob, and it will pop back up. Pilot should remain lit.
If it goes out, repeat steps 5 through 9.
• Ifknobdoesnotpopupwhenreleased,STOPandIM-
MEDIATELY call a qualied service technician or gas
supplier.
• Ifthepilotwillnotstaylitafterseveraltries,turnthegas
control knob to "OFF" and call your service technician or
gas supplier.
10. Turn gas control knob counterclockwise to "ON".
11. Set REMOTE/OFF/ON switch to desired setting.
12. Turn on all electric power to the appliance (if applicable).
13. Close bottom louver assembly (if applicable).
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
THERMOCOUPLE
(NATURAL)
ELECTRODE
PILOT
THERMOPILE
REMOTE
OFF
ON
THERMOCOUPLE
(LPG)
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
THERMOCOUPLE
(NATURAL)
ELECTRODE
PILOT
THERMOPILE
REMOTE
OFF
ON
THERMOCOUPLE
(LPG)
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
THERMOCOUPLE
(NATURAL)
ELECTRODE
PILOT
THERMOPILE
REMOTE
OFF
ON
THERMOCOUPLE
(LPG)
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
WARNING

personal injury or loss of life.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

American Hearth Lincoln 26 Fireplace (VFD26FP) Owner's manual

Category
Fireplaces
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI