Wacker Neuson PSC43803EX User manual

Category
Water pumps
Type
User manual

This manual is also suitable for

Operator’s Manual
Pump
PSC3 1603EX
PSC4 2303EX
PSC4 3803EX
5000187881 03 1211
5000187881
EN
Copyright
notice
© Copyright 2011 by Wacker Neuson Production Americas LLC
All rights, including copying and distribution rights, are reserved.
This publication may be photocopied by the original purchaser of the machine. Any
other type of reproduction is prohibited without express written permission from
Wacker Neuson Production Americas LLC.
Any type of reproduction or distribution not authorized by Wacker Neuson Production
Americas LLC represents an infringement of valid copyrights. Violators will be
prosecuted.
Trademarks
All trademarks referenced in this manual are the property of their respective owners.
Manufacturer
Wacker Neuson Production Americas LLC
N92W15000 Anthony Avenue
Menomonee Falls, WI 53051 U.S.A.
Tel: (262) 255-0500 · Fax: (262) 255-0550 · Tel: (800) 770-0957
www.wackerneuson.com
Original
instructions
This Operator’s Manual presents the original instructions. The original language of this
Operator’s Manual is American English.
Foreword
wc_tx001310gb.fm 3
Foreword
SAVE THESE INSTRUCTIONS—This manual contains important instructions for
the machine models below. These instructions have been written expressly by
Wacker Neuson Production Americas LLC and must be followed during installation,
operation, and maintenance of the machines.
Machines covered in this manual
Machine
documentation
Keep a copy of the Operator’s Manual with the machine at all times.
Use the separate Parts Book supplied with the machine to order replacement
parts.
Refer to the separate Repair Manual for detailed instructions on servicing and
repairing the machine.
If you are missing any of these documents, please contact Wacker Neuson
Corporation to order a replacement or visit www.wackerneuson.com.
When ordering parts or requesting service information, be prepared to provide
the machine model number, item number, revision number, and serial number.
Expectations
for
information in
this manual
This manual provides information and procedures to safely operate and main-
tain the above Wacker Neuson model(s). For your own safety and to reduce the
risk of injury, carefully read, understand, and observe all instructions described
in this manual.
Wacker Neuson Corporation expressly reserves the right to make technical
modifications, even without notice, which improve the performance or safety
standards of its machines.
The information contained in this manual is based on machines manufactured
up until the time of publication. Wacker Neuson Corporation reserves the right
to change any portion of this information without notice.
Manufacturer’s
approval
This manual contains references to approved parts, attachments, and
modifications. The following definitions apply:
Approved parts or attachments are those either manufactured or provided by
Wacker Neuson.
Approved modifications are those performed by an authorized Wacker Neu-
son service center according to written instructions published by Wacker Neu-
son.
Unapproved parts, attachments, and modifications are those that do not
meet the approved criteria.
Unapproved parts, attachments, or modifications may have the following
consequences:
Machine Item Number
PSC3 1603EX
PSC4 2303EX
PSC4 3803EX
0620471
0620472
0620473
Foreword
4 wc_tx001310gb.fm
Serious injury hazards to the operator and persons in the work area
Permanent damage to the machine which will not be covered under warranty
Contact your Wacker Neuson dealer immediately if you have questions about
approved or unapproved parts, attachments, or modifications.
Translation of the original Declaration of Conformity
EC Declaration of Conformity
Manufacturer
Wacker Neuson Produktion GmbH & Co. KG, Preußenstraße 41, 80809 München
Product
Directives and standards
We hereby declare that this product meets and complies with the relevant regulations and
requirements of the following directives and standards:
2006/42/EG, 2006/95/EG, 2004/108/EG, EN 809, EN 60335-2-41, EN 61000-6
Authorized person for technical documents
Axel Häret,
Wacker Neuson Produktion GmbH & Co. KG, Preußenstraße 41, 80809 München
Product
PSC3 1603Ex PSC4 2303Ex PSC4 3803Ex
Product category Submersible water pump
Product function Water pumping
Item number 0620471 0620472 0620473
Dr. Michael Fischer
Director of Technology and Innovation
München, 01.08.2011
PSC EX Table of Contents
wc_bo5000187881_03TOC.fm 7
Foreword 3
EC Declaration of Conformity 5
1 Safety Information 9
1.1 Signal Words Used in this Manual ....................................................... 9
1.2 Machine Description and Intended Use ............................................. 10
1.3 Operating and Electrical Safety .......................................................... 12
1.4 Informational Labels ........................................................................... 12
2 Operation 14
2.1 Names of Parts ................................................................................... 14
2.2 Prior to Operation ............................................................................... 16
2.3 Installation .......................................................................................... 16
2.4 Preparing for installation ..................................................................... 17
2.5 Installing the Pump ............................................................................. 20
2.6 Electrical Wiring .................................................................................. 22
2.7 Cable Assembly ................................................................................. 24
2.8 Motor Wiring ....................................................................................... 25
2.9 Operation ............................................................................................ 26
2.10 Operating Water Level ....................................................................... 28
2.11 Motor Protectors ................................................................................. 29
2.12 Emergency Shutdown Procedure ....................................................... 29
3 Maintenance 30
3.1 Periodic Maintenance Table ............................................................... 30
3.2 Maintenance and Inspection .............................................................. 31
3.3 Inspecting and Replacing Lubricant ................................................... 32
3.4 Disassembly/Reassembly .................................................................. 33
3.5 Disassembly ....................................................................................... 34
3.6 Reassembly ........................................................................................ 35
3.7 Troubleshooting .................................................................................. 36
Table of Contents PSC EX
8 wc_bo5000187881_03TOC.fm
4 Technical Data 38
4.1 Standard Specifications .......................................................................38
4.2 Operating Specifications .....................................................................39
5 AEM Safety Manual 41
PSC EX Safety Information
wc_si000372gb.fm 9
1 Safety Information
1.1 Signal Words Used in this Manual
This manual contains DANGER, WARNING, CAUTION, NOTICE, and
NOTE signal words which must be followed to reduce the possibility
of personal injury, damage to the equipment, or improper service.
NOTICE: Used without the safety alert symbol, NOTICE indicates a situa-
tion which, if not avoided, could result in property damage.
Note: A Note contains additional information important to a procedure.
This is the safety alert symbol. It is used to alert you to potential personal hazards.
f Obey all safety messages that follow this symbol.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death
or serious injury.
f
To avoid death or serious injury from this type of hazard, obey all safety messages that
follow this signal word.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
f
To avoid possible death or serious injury from this type of hazard, obey all safety mes-
sages that follow this signal word.
CAUTION!
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
f
To avoid possible minor or moderate injury from this type of hazard, obey all safety mes-
sages that follow this signal word.
Safety Information PSC EX
10 wc_si000372gb.fm
1.2 Machine Description and Intended Use
This machine is a submersible cutter pump. The Wacker Neuson
Submersible Cutter Pump consists of an electric motor, an impeller with a
carbide tip and cutter plate, a stand, and a metal casing with ports for
water or sewage suction and discharge. During operation, the impeller
cuts solid material until it is small enough to pass through the discharge
port. Power is supplied to the pump through a corded plug or a hard-wired
connection, depending on the installation. The operator connects pipes to
the pump and routes them so that water or sewage is pumped from the
work area and discharged into an appropriate location.
This machine is intended to be used for residential, commercial, and
industrial pumping of waste water with variable solids inclusion. This
machine is designed and intended to operate efficiently up to the flow,
head, and suction lift limits stated within the product specifications.
This machine has been designed and built strictly for the intended use
described above. Using the machine for any other purpose could
permanently damage the machine or seriously injure the operator or other
persons in the area. Machine damage caused by misuse is not covered
under warranty.
The following are some examples of misuse:
Pumping flammable, explosive, or corrosive fluids
Pumping hot or volatile fluids that result in pump cavitation
Operating the pump outside of product specifications due to incorrect
diameter pipes, incorrect length pipes, other inlet or outlet
restrictions, or excessive suction lift or head
Using the machine as a ladder, support, or work surface
Using the machine to carry or transport passengers or equipment
Operating the machine outside of factory specifications
Operating the machine in a manner inconsistent with all warnings
found on the machine and in the Operator’s Manual.
This machine has been designed and built in accordance with the latest
global safety standards. It has been carefully engineered to eliminate
hazards as far as practicable and to increase operator safety through
protective guards and labeling. However, some risks may remain even
after protective measures have been taken. They are called residual
risks. On this machine, they may include exposure to:
Electric shock from improper electrical connections or high voltage
Personal injury from improper lifting techniques
Projectile hazard from discharge
PSC EX Safety Information
wc_si000372gb.fm 11
To protect yourself and others, make sure you thoroughly read and
understand the safety information presented in this manual before
operating the machine.
Operator qualifications
Only trained personnel are permitted to start, operate, and shut down
the machine. They also must meet the following qualifications:
have received instruction on how to properly use the machine
are familiar with required safety devices
The machine must not be accessed or operated by:
•children
people impaired by alcohol or drugs
Personal Protective Equipment (PPE)
Wear the following Personal Protective Equipment (PPE) while
operating this machine:
Close-fitting work clothes that do not hinder movement
Safety glasses with side shields
Hearing protection
Safety-toed footwear
Safety Information PSC EX
12 wc_si000372gb.fm
1.3 Operating and Electrical Safety
To reduce risk of electric shock, connect only to a properly grounded,
grounding-type receptacle.
Risk of electric shock—this pump has not been investigated for use in
swimming pool areas.
An acceptable motor-control switch shall be provided at the time of
installation according to local codes and regulations.
To reduce risk of electric shock, follow instructions in this manual for
proper installation.
CAUTION: This pump may automatically restart. Prior to working on
the pump or control panel, all supply circuits must be disconnected.
CAUTION: Risk of shock—do not remove cord and strain relief.
1.4 Informational Labels
Label Meaning
A nameplate listing the model number, item num-
ber, revision number, and serial number is
attached to each unit. Please record the informa-
tion found on this nameplate so it will be available
should the nameplate become lost or damaged.
When ordering parts or requesting service infor-
mation, you will always be asked to specify the
model number, item number, revision number,
and serial number of the unit.
CAUTION
Do not attempt to operate this product before reading the
Operator’s Manual and understanding its contents.
Mishandling of this product may result in explosion, fire, or
electrical shock.
Do not pull on the power cord or use the power cord to lift
the pump.
Always use a dedicated ground leakage circuit breaker.
Be sure to install the ground wire securely.
Be sure to disconnect the power supply before handling
or inspecting the pump.
Never insert your hand into the pump inlet holes while the
pump is connected to the power supply.
WARNING
JAPAN
JAPAN
PSC EX Safety Information
wc_si000372gb.fm 13
Notes:
Operation PSC EX
14 wc_tx001311gb.fm
2 Operation
2.1 Names of Parts
See Graphics: wc_gr007086 and wc_gr007096
Ref Description Ref Description
1 Cable 15 Flange
2 Gland 16 Motor bracket
3 Stuffing box 17 Upper bearing
4 Pump casing 18 Lower bearing
5 Impeller 19 Miniature protector
6 Suction cover 20 Shaft
7 Stand 21 Rotor
8 Mechanical seal 22 Stator
9 Oil seal 23 Bearing housing
10 Oil lifter 24 Bearing cover
11 Oil plug 25 Motor frame
12 Lubricant 26 Eye bolt
13 Discharge bend
14 Air release valve
PSC EX Operation
wc_tx001311gb.fm 15
2
2
12
1
2
3
16
11
26
17
19
21
22
24
18
23
20
4
25
7
15
9
10
8
13
14
5
6
wc_gr007096
PSC4 2303EX
PSC4 3803EX
1
2
3
16
25
20
26
17
19
21
22
24
18
23
4
15
7
8
9
10
11
12
13
14
5
6
wc_gr007086
PSC3 1603EX
Operation PSC EX
16 wc_tx001311gb.fm
2.2 Prior to Operation
When the pump is delivered, first perform the following checks:
Inspection
While unpacking, inspect the product for damage during shipment, and
make sure all bolts and nuts are tightened properly.
Specification check
Check the model number to make sure it is the product that was
ordered. Be certain it is the correct voltage and frequency.
Note: If there is any problem with the product as shipped, contact your
nearest dealer or Wacker Neuson representative at once.
Product specifications
Do not operate this product under any conditions other than those for
which it is specified. Failure to observe this precaution can lead to
electrical shock, current leakage, fire, water leakage or other
problems.
2.3 Installation
Preparing for Installation
Observe the following points when preparing to install the pump.
Be aware that leakage of pump lubricants may cause pollution of
water.
An appropriate plug or electrical connection must be provided
according to local codes and standards. Refer to the wiring
diagram.
Use with a power supply voltage within ±5% of the rated voltage.
Operating Safety
Do not operate the pump if the maximum water pressure in the
area exceeds 0.3 Mpa–discharge pressure.
Do not use this pump in liquids other than water, such as oil, salt
water, or organic solvents. Contact your Wacker Neuson dealer
with questions about specific fluids.
Do not use in water temperatures outside the range of 0–40°C
(32–104°F) which can lead to failure, electrical leakage or shock.
Do not use in the vicinity of explosive or flammable materials.
Do not operate the pump if any parts are loose or missing.
CAUTION
PSC EX Operation
wc_tx001311gb.fm 17
2.4 Preparing for installation
Before installing the pump at a work site, you will need to have the
following tools and instruments ready:
Insulation resistance tester (megohmmeter)
AC voltmeter
AC ammeter (clamp-on type)
Bolt and nut tighteners
Power supply connection tools (screwdriver or box wrench)
Note: Please also read the instructions that come with each of the test
instruments.
Measure resistance
Use a megohmmeter to measure the insulation resistance between
each core lead and the ground lead to verify the insulation resistance
of the motor.
Reference insulation resistance: 20MΩ or greater
Note: The reference insulation resistance (20M
Ω
or greater) is the value
when the pump is new or has been repaired. For the reference value after
installation, see “Periodic Maintenance Table.”
Description Description
U Power Lead (Black) S1 Protector Circuit (Black)
V Power Lead (Black) S2 Protector Circuit (Black)
W Power Lead (Black) G Ground (Green/Yellow)
wc_gr007215
Operation PSC EX
18 wc_tx001311gb.fm
Checks to make before installation
With the megohmmeter, measure the insulation resistance between
each core lead and the ground lead.
Reference insulation resistance: 20MΩ or greater
Note: The reference insulation resistance (20M
Ω
or greater) is the
value when the pump is new or has been repaired. For the reference
value after installation, see “Periodic Maintenance Table.”
PSC EX Operation
wc_tx001311gb.fm 19
Notes
Operation PSC EX
20 wc_tx001311gb.fm
2.5 Installing the Pump
Overview
This pump requires careful installation to operate at peak efficiency.
Observe the following recommendations when installing the pump.
Placing the pump
A sample installation diagram is provided below. Contact your Wacker
Neuson dealer for help in installing the pump for your particular
application.
Install the pump on a flat, smooth surface, such as a concrete
pad.
Do not place the pump in areas that may be susceptible to
turbulence or may allow the pump to take in air—for example,
near the inlet of a water tank. Install a baffle if it is impossible to
keep the pump away from these areas.
Install piping so that air pockets cannot form anywhere in the
system.
NOTICE: If the pump is being controlled automatically, discharged water
could flow backwards. This backflow may trigger the water surface control
immediately, forcing the pump to continuously cycle ON and OFF.
Permanent damage to the pump may result.
Install a check valve if the pump tank is deep, or if the vertical
head or the lateral distance is long.
Description Description
a Cable g Manhole cover
b Baffle plate h Control panel
c Start position j Gate valve
d Stop position k Check valve
e Level switch l Pipe
f Chain m Pump
wc_gr007207
a
h
j
g
f
k
l
m
b
c
d
e
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54

Wacker Neuson PSC43803EX User manual

Category
Water pumps
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI