CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
1) Find the appropriate threaded holes on mounting strap[1]
that align with hole distance in canopy[2] Thread mounting
screws[3] into threaded holes starting from outlet box[4] side.
2) Attach mounting strap to outlet box with strap mounting
screws[5]. Mounting strap can be adjusted to suit position of
xture.
3) Grounding instructions: (See Illus. A or B)
A) Onxtureswheremountingstrapisprovidedwithahole
and two raise dimples. Wrap ground wire from outlet box
around green ground screw, and thread into hole.
B) Onxtureswhereacuppedwasherisprovided.Put
ground wire from outlet box under cupped washer and
green ground screw and thread screw into hole in mount-
ing strap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wire to outlet box ground wire with wire connector, after follow-
ingtheabovesteps.Neverconnectgroundwiretoblackor
white power supply wires.
4) Makewireconnections.Referencechartbelowforcorrectcon-
nections and wire accordingly.
5) Pushxturetowallcarefullypassingmountingscrewswith
holesincanopy.Makesureallwiresareinsidecanopyanddo
notgetpinchedbetweenwallandcanopyofxture.
6) Threadlockupknobs[6] onto mounting screws and tighten to
securexturetowall.
7) Insertrecommendedbulb(Notsupplied).
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS
AND/OR IN WET LOCATIONS.
8) Mountingsurfaceshouldbeclean,dry,atand1/4”larger
that the canopy on all sides. Any gaps between the mounting
surfaceandcanopyexceeding3/16”shouldbecorrectedas
required.
9) Withsiliconecaulkingcompound,caulkcompletelyaround
wherebackofcanopymeetsthewallsurfacetopreventwater
from seeping into outlet box.
Date Issued: 09/14/17 IS-49917-US
Estamos aquí para ayudarle 866-558-5706
Horario: Lunes-Viernes 9am a 5pm EST (hora ocial del este)
1) Encuentrelosoriciosroscadosadecuadosenlacorreade
montaje[1]quesealineanconladistanciadelagujeroenel
dosel[2]Enrosquelostornillosdemontaje[3]enlosoricios
roscadosdesdeelladodelacajadesalida[4].
2) Fijelacorreademontajealacajadesalidaconlostornillosde
jacióndelacorrea[5].Lacorreademontajesepuedeajustar
paraadaptarsealaposicióndelaparato.
3) Instruccionesparaponeratierra:(VerIlustracionesAoB).
A) Enartefactosdondesesuministralaabrazaderade
montajeconunagujeroydosdepresionesonduladas.
Envuelvaelconductordetierradelacajadesalida
alrededordeltornillodetierraverdeyatornilleenel
agujero.
B) Enartefactosdondesesuministraunaarandela
cóncava.Fijeelconductordetierradelacajadesalida
debajodelaarandelacóncavayeltornillodetierra
verdeyenrosqueenlaabrazaderademontaje.
Sisesuministraelartefactoconconductordetierra.Conecte
elconductordetierradelartefactoalconductordetierrade
lacajadesalidaconconectordetierradespuésdeseguirlos
pasosanteriores.Nuncaconecteelconductordetierraalos
alambresdealimentacióneléctricanegrosoblancos.
4) Hagalasconexionesdelosalambres.Reérasealatablade
abajopararealizarlasconexionescorrectasdeloscables.
5) Empujelajaciónalaparedpasandocuidadosamentelos
tornillosdemontajeconlosoricioseneldosel.Asegúresede
quetodosloscablesesténdentrodeldoselyquenoqueden
atrapadosentrelaparedyeldoseldelaparato.
6) Controlesdebloqueodelhilo[6]enlostornillosdemontajey
apriételosparajareljadoralapared.
7) Insertelabombillarecomendada(Noincluido).
INSTRUCCIONES PARA EL MONTAJE DEL ARTEFACTO AL
AIRE LIBRE Y/O EN UN LUGAR MOJADO.
8) Lasuperciedemontajedebeestarlimpia,seca,serplanay
1/4”másgrandequeelesdudeteentodoslosbordes.Cual-
quierespaciolibreentrelasuperciedemontajeyelescudete
queexcedade3/16”debecorregirsesegúnserequiera.
9) Calafateetotalmenteconcompuestodecalafateardesilicona
alrededordondeelescudetesientaenlasuperciedelapared
paraimpedirlaentradadeaguaenlacajadeconexiones.
PRECAUCIÓN – RIESGO DE DESCARGA ELÉCTRICA
Desconecte la electricidad en el panel principal del interruptor
automático o caja principal de fusibles antes de comenzar y
durante la instalación.
  • Page 1 1
  • Page 2 2

Kichler Lighting 49919BK User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages