Acoustic Test Report
Ovation Rêve E-3
Chauvet Professional – www.chauvetprofessional.com
©2021, Chauvet & Sons, LLC. All rights reserved.
All product specifications, measurements, and dimensions are subject to change without notice.
Instrumentation
The following were used in the acoustic testing:
Mechanical thermohygrograph
Results
The Ovation Rêve E-3 was measured in four different scenarios:
1. Full Intensity, Fan Mode: Auto
2. Full Intensity, Fan Mode: On
3. Full Intensity, Fan Mode: Off
4. Full Intensity, Fan Mode: Silent
The sound pressure levels are listed in the table below:
Sound Pressure Level (dB)
Full intensity – Fan Mode: Auto 34.20
Full intensity – Fan Mode: On 36.75
Full intensity – Fan Mode: Off 20.98
Full intensity – Fan Mode: Silent 23.28