Renkforce RF-19"-USB2-RS232-8 Owner's manual

Category
Serial switch boxes
Type
Owner's manual

This manual is also suitable for

If it is no longer possible to operate the product safely, stop using it and prevent
unauthorised use. Safe operation can no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
Please handle the product carefully. Jolts, impacts or a fall even from a low height
may damage the product.
Always observe the safety information and operating instructions of any other
devices which are connected to the product.
Consult a technician if you are not sure how to use or connect the product, or if
you have concerns about safety.
Maintenance, modications and repairs must only be carried out by a technician
or a specialist repair centre.
If you have any questions that are not answered in these operating instructions,
please contact our technical customer service or other professionals.
b) Electrical safety
Before connecting the product to the mains, check that your local A/C mains
voltage matches the specications on the nameplate.
The power adapter is built according to protection class II. Only connect the
adapter plug to a standard mains socket (230 V/AC, 50 Hz) connected to the
public grid.
Never pour liquids over electrical devices or place objects lled with liquid next
to the device. If liquid or an object does get inside the device, power down the
respective socket (e.g. switch off the circuit breaker), and then remove the mains
plug from the mains socket. Discontinue use and take the product to a specialist
repair centre.
Never use the product immediately after it has been brought from a cold room
into a warm one. The condensation that forms might destroy the product. The
power adapter may also generate a fatal electric shock! Allow the product to reach
room temperature before connecting it and putting it to use. This may take several
hours.
Do not touch the power adapter if there are any signs of damage, as this may
cause a fatal electric shock! Switch off the mains voltage to the socket containing
the power adapter (switch off at the corresponding circuit breaker or remove the
safety fuse, and then switch off at the corresponding RCD protective switch).
You can then unplug the power adapter from the mains socket. Dispose of the
faulty power adapter in an environmentally friendly manner and discontinue use.
Replace it with a power adapter of the same design.
The mains outlet must be located near to the device and be easily accessible.
Never connect or disconnect power adapters if your hands are wet.
Never unplug the power adapter from the mains socket by pulling on the cable;
always use the grips on the plug.
When setting up the product, ensure that the cables are not pinched, kinked or
damaged by sharp edges.
Always lay the cables so that nobody can trip over or become entangled in them.
This poses a risk of injury.
For safety reasons, disconnect the power adapter from the mains socket during
storms.
Never leave the product unattended during use.
The housing warms up during use. Ensure that there is sufcient ventilation. Do
not cover the housing!
Only power the product using the power adapter provided.
When using the power adapter, ensure that the total current consumption of all the
connected devices does not exceed 2 A.
Operating instructions
19” (48.26 cm) 8-PORT USB 2.0 TO RS422/485
PANEL
19” (48.26 cm) 8-PORT USB 2.0 TO RS232 PANEL
Item no. 1647064
Item no. 1647067
Intended use
This product is designed to be connected to a computer with a USB 2.0 interface and provides
an RS422/485 (item no. 1647064) or RS232 serial interface (item no. 1647067). On the product
with item no. 1647064, the interfaces can also be connected via the RS485 adapter supplied.
The converter operates bidirectionally, i.e. it transmits signals from the computer (upstream)
and from connected devices (downstream). It is compliant with the USB 2.0 specication.
The necessary drivers and installation instructions are available on the driver CD supplied.
The supply voltage is via an external power adapter. An optional voltage of 36 V/DC can be
connected.
This product is intended for indoor use only. Do not use it outdoors. Contact with moisture (e.g.
in a bathroom) must be avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or modify this product. Using the
product for purposes other than those described above may damage the product. In addition,
improper use may cause hazards such as a short circuit, re or electric shock. Read the
operating instructions carefully and store them in a safe place. If you pass the product on to a
third party, please hand over these operating instructions as well.
This product complies with statutory, national and European regulations. All company and
product names included herein are trademarks of their respective owners. All rights reserved.
Delivery content
1x converter
2x mounting brackets
4x screws
1x USB cable
1x 8 cm driver CD
1x power adapter
8x RS485 adapter (only with item no. 1647064)
Operating instructions
Up-to-date operating instructions
Download the up-to-date operating instructions at www.conrad.com/downloads or scan the QR
code shown. Follow the instructions on the website.
Explanation of symbols
The symbol with the lightning in a triangle indicates that there is a risk to your health,
e.g. due to an electric shock.
The symbol with an exclamation mark in a triangle is used to highlight important
information in these operating instructions. Always read this information carefully.
The arrow symbol indicates special information and tips on how to use the product.
This symbol indicates that this product is built according to protection class II. It is
equipped with reinforced or dual insulation between the mains circuit and the output
voltage.
The product must only be installed and used in dry, indoor locations. It must not
become damp or wet, as this may cause a fatal electric shock!
Safety information
Read the operating instructions and safety information carefully. If you do
not follow the safety information and information on proper handling in these
operating instructions, we will assume no liability for any resulting personal
injury or damage to property. Such cases will invalidate the warranty/
guarantee.
a) General information
The device is not a toy. Keep it out of the reach of children and pets.
Do not leave packaging material lying around carelessly. It may become a
dangerous plaything for children.
Protect the product from extreme temperatures, direct sunlight, strong jolts, high
humidity, moisture, ammable gases, vapours and solvents.
Do not place the product under any mechanical stress.
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microlming or capturing in
electronic data processing systems) requires prior written approval from the publisher. Reprinting, also in part, is
prohibited. This publication reects the technical status at the time of printing.
Copyright 2019 by Conrad Electronic SE. *1647064_67_v1_0119_02_DS_m_4L_(1)
Operating elements
1 2 3
4
5
1 2 3
4
5
78
6
9
1 POWER LED 2 USB-B port USB-IN (input)
3 USB-A ports USB1 USB2
(2 outputs)
4 RS485 (item no. 1677064) outputs
RS232 (item no. 1677067) outputs
5 LED indicators for the outputs 6 Ventilation openings (concealed)
7 Mains cable DC 5 V 8 Mains cable DC9-36 V
9 Threaded holes for mounting brackets
(concealed)
Mounting in a 19” server rack
You can use the mounting bracket to mount the converter in a standard 19” server rack. To
mount in a server rack, proceed as follows:
Remove all connected devices and unplug the power adapter from the mains socket
(7 or 8) on the converter.
Use the screws provided to secure the mounting bracket to the threaded holes (9) on the
housing.
This gure is not a detailed representation of the product. It merely illustrates
installation of the mounting brackets.
Then, mount the pre-assembled converter in the rack.
Ensure that the mains socket for connecting the power adapter is close to the place
of installation.
Setup
Connect the USB-B port USB-IN (2) on the converter to the USB output of a computer/server
using the USB cable supplied.
You can connect up to 2 USB devices to the USB-A outputs USB 1 and USB 2. An additional
USB cable may be required (not included). The maximum available output current per output
is 0.5 A.
You can directly connect up to 8 devices with corresponding connectors via the connections
(with item no. 1647064).
Use the RS485 adapter supplied to directly connect cables and
wires for RS422, if necessary. Use an appropriate screwdriver to
screw down the individual wires. Observe the printed descriptions of
the individual connection terminals.
You can connect up to 8 devices via the RS232 connections (with item no. 1647067).
Connect the low-voltage plug on the power adapter to the mains socket 5 V/DC (7) to connect
the 5 V/DC supply voltage.
Alternatively, connect the low-voltage plug on the power adapter to the mains socket
9-36 V/DC (8) to connect the 9-36 V/DC supply voltage.
Never connect both power supplies at the same time. Use only one power
connection.
Start up the converter.
Install the necessary drivers for your operating system from the driver CD supplied. Follow
the installation instructions in the “AN_396 FTDI Drivers Installation Guide”, which is available
on the CD.
The converter is now ready for use.
Care and cleaning
Always disconnect the product from the power supply before cleaning it.
Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may
damage the housing or cause the product to malfunction.
Use a dry, lint-free cloth to clean the product.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product according to
the relevant statutory regulations.
You thus full your statutory obligations and contribute to environmental protection.
Technical data
a) Converter
Operating voltage ......................... 5 V/DC (input 1), optional 36 V/DC (input 2)
Output current ............................... 0.5 A (per port)
USB standard ............................... USB 2.0
USB A connections ....................... 2x USB 2.0
USB B connections ....................... 1x USB 2.0
Connections .................................. 8x RS422 (item no. 1647064)
8x RS232 (item no. 1647067)
System requirements .................... Windows
®
2000, XP (Home, Pro, with SP1, SP2, SP3, 32
bit only), Vista™ (32 bit),
7 (32/64 bit), 8 & 8.1 (32/64 bit), 10 (32/64 bit), 10S
Mac OS 8.0 or higher to Mac OS X, Linux 8.4 to 4.14
Operating conditions ..................... 0 to +55 °C, 0 - 95 % relative humidity (non-condensing)
Storage conditions ........................ -20 to +70 °C, 0 - 95 % relative humidity (non-condensing)
Dimensions (W x H x D) ............... 443 x 45 x 138.5 mm
Weight .......................................... 1647 g (item no. 1647064)
1623 g (item no. 1647067)
b) Power adapter
Input voltage/current ..................... 100 - 240 V/AC, 50/60 Hz, 0.45 A
Output voltage/current .................. 5 V/DC, 2 A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Renkforce RF-19"-USB2-RS232-8 Owner's manual

Category
Serial switch boxes
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI