Lightolier 1003R User manual

  • Hello! I am an AI chatbot trained to assist you with the Lightolier 1003R User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • I0906
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lytecaster
®
Recessed Downlighting 1003R
Page 1 of 1 5" Aperture 0 Incandescent Non-IC Remodeler Frame-In Kit
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
Frame-In Kit Reflector Trims — See Individual Reflector Trim Specification Sheets
Open Downlight
Satin Baffles Basic Pinhole Recessed Enclosed Wall Open
Reflector Cone Cone White Adjustable Diffusers Washer Wet Location
1003R 1045 1012 1008 1005 1071 1011 1027 1038 1021 1035 1084CD
1046 1012NM 1008NM 1005WH 1027WH 1038NM 1024 1035WH 1084WH
1046CD 1013 1010 1005NM 1027BK 1048 1078 1085
1013BK 1010NM 1005BNM 1027NM 1048NM 1090
1013WH 1076 1027BNM
1013CD 1076WH 1027CD
1013NM 1027BKNM
1013BKNM 1027CDNM
1013CDNM
Eyeball:
1022 1023
1022WH 1023WH
1082
Frame-In Kit
Reflector Trim
2
3
5
1
4
Top View
13”
Ceiling Opening
5 1/2"
Features
1. Mounting Ring: .032 (#22 ga.) galvanized steel. Accommodates existing
ceilings up to 2" thick. Attaches securely to any type of ceiling material
without tools using (3) mounting straps provided. Push-in/twist-out clips
hold reflector flush to ceiling. Includes adhesive backed aperture template.
2. Junction Box: 2 1/2" X 2 1/2" X 3 1/2" (21 cu. in.) .032 (#22 ga.) galvanized
steel. U.L. listed for 90° C supply wire. Integral cable clamps permit attach-
ment of non-metallic (#12 or #14 ga.) Romex
®
cable without tools
or additional connectors. Attaches to mounting ring without tools.
3. Socket Housing: Impact extruded aluminum or galvanized steel.
4. Socket: Porcelain medium base; nickel plated screw shell. Pre-wired with
#18 ga. SF1 (300 VOLT 200° C) leads to junction box.
5. Thermal Protector: Meets NEC and U.L. requirements. Do not install
insulation within 3 inches of fixture sides or wiring compartment nor above
fixture in such a manner as to entrap heat.
Labels
UL (Suitable for Damp Locations)
Romex
®
is a registered trademark of General Cable Industries Inc.
/