Legrand UTP/Coax Cable Tester w/Remote, IS-0082 Installation guide

Category
Cable network testers
Type
Installation guide

Legrand UTP/Coax Cable Tester w/Remote, IS-0082 is a handheld device designed to test the integrity and continuity of UTP (unshielded twisted pair), STP (shielded twisted pair), and coaxial cables commonly used in structured cabling networks.

It can perform a variety of tests, including continuity, shorts, opens, crossed connections, transposed pairs, and split pairs. The tester can also generate an oscillating audio tone for tracing cables and identifying individual pairs within a cable bundle.

To use the tester, simply connect one end of the tester to one end of the cable you want to test and the other end of the tester to the other end of the cable. The tester will then perform a series of tests and display the results on its LCD screen.

Legrand UTP/Coax Cable Tester w/Remote, IS-0082 is a handheld device designed to test the integrity and continuity of UTP (unshielded twisted pair), STP (shielded twisted pair), and coaxial cables commonly used in structured cabling networks.

It can perform a variety of tests, including continuity, shorts, opens, crossed connections, transposed pairs, and split pairs. The tester can also generate an oscillating audio tone for tracing cables and identifying individual pairs within a cable bundle.

To use the tester, simply connect one end of the tester to one end of the cable you want to test and the other end of the tester to the other end of the cable. The tester will then perform a series of tests and display the results on its LCD screen.

A
L-T2hnologies
a
LAN ProNavigatorTM
UTP/Coax Cable Tester with Remote
AUTO-OFF Power Save Circuit:
1. The main tester has an automatic power shut down circuit to save battery life.
The power to the unit will turn off after approx. 20 seconds of non-use during
normal testing and fault check operations, and 30 minutes in tone mode. To
prevent power shut down, periodically press the “Fault CheckiTone” switch.
2. Pressing the “On/Test” switch atIer a test will turn the unit off.
Warning: Do not use on live lines or energized circuits!
READ BEFORE USE:
1. Connect battery prior to use.
2. Never
open the case of the main tester. Access battery through the battery door
provided.
3. Do not use in high moisture environments.
4. Use the provided screw to attach the belt clip to the main test unit. Use the case
screw on the Remote to attach the belt clip.
5. The One Year Limited Warranty covers materials and workmanship. Normal wear and
tear, or damage due to misuse is not covered under the warranty.
6. This test system does not test for network frequency, cross talk (NEXT), decibel level,
data packets, transmission rate, or live circuit line indication.
7. Split Pair detection requires a minimum cable length of 6 feet (2 meters). Cables of less
length may have incorrect test results indication.
Technical Data:
Type
Main Tester
Remote
Power Requirements
9-volt Battery
NO”*
Operating Temp.
3Z0- 11O’F 3Z0- IIO’F (0°-43°C)
Storage Temp.
IO’- IZO’F
IO’- lZO’F(-12”. 48°C)
Output Signal
dc-2Mhz Pulse NOIX
Weight
5.6 oz.
1.6 oz.
Battery Life
1000 tesk
n/a
Battery life based on standard non-alkaline batteries.
4
OnQ Technologies, Inc.
301 Fulling Mill Road
Middletown, PA 17057
Phone: (800,321.2343
Fax: (717) 702-2546
website:
-.onqtsch.com
A
A-T2hnologies
4b
LAN ProNavigatorTM
UTP/Coax Cable Tester with Remote
Operating instructions
Part Number 364276-01
IS-0082
Rev. B
Warning: Do not use on live
TSSW * TrmB
EIAmAJB*A
or energized circuits!
,SDN
EIAmASSllB
100 SASE-T. TP.PMD SYSTEMAX scs
TOKEN RING 10 SASE-T ATM ISSMbps 100 BASE-T8
Tests common network types:
*THE FASTEST AND EASIEST TESTER YOU WILL EVER USEI
* Tests data, telephone, and coaxial cable continuity up to 320 feet (100 meters).
* Split Pair detection is 6 feet (2 meters) to 320 feet (100 meters).
* Tests proper pairing to EIAITIA-568 A 8 B for CaM, Catd, Cat-Be, Cat-6, ISDN,
Token Ring, 10 Base-T, 100 Base-T, 258A, and other common network types.
l
Test status reported at both ends of the cable: Main and Remote unit indicators.
* Tests Unshielded Twisted Pair (UTP) and Shielded Twisted Pair (STP) cables.
*Tests 50-ohm and 75-ohm coaxial cables.
* Generates oscillating audio tone for tracing cables using remotes or tone probes.
* Detects opens, shorts, crossed connections, transposed pairs, and split pairs.
* QUICK TESTING -Simple “Pass” or “Fail” indication in one second. Or user
optional “Fault Check” function for troubleshooting cable failures.
‘Auto-off power shut down conserves battery life.
* Uses standard g-volt batteries (included).
* Belts clips and patch cables provided.
* One Year Limited Warranty
OnQ Technologies, Inc.
301 Fulling Mill Road
Middletown, PA 17057
Phone: (800) 321-2343
Fax: (717) 702-2346
website:
vmw.onqtech.com
ODeratina Instructions
FAULT CHECK for Troubleshooting Faulty Cables:
Indicator Light Reference: @= ON a= OFF @= FLASHING
Testing UTP Cables:
1. Connect the main tester to the huh uring a patch cord. Connect the remote unit to the
wall jack using a patch cord. If te*ting cables, attach units directly to cable ends.
1. Do not turn off the tester after petfoning s test The tester must remain on to retain test results.
zpre=* @ = ,* u* =I ,~ s”D
@ @ 0 0 0 “First Pair to be Checked” + @ “ON” (Pair 112 Good)
posse
‘zpre*r @ k cllmlg
“Second Pair to be Checkefl + I@ “ON” (Pair 36 Bad)
OPEN
OR
4. Test complete. Go to the next cable test or perform e “Fe”,, Check” operation
to troubleshoot faulty cilbles. Do not pm** the “ONITEST” button. This will turn
off the tester and prevent * “Fault Check” from being performed.
Testing STP Cables:
4. Step through the pairs 112 through SHD by continuously pressing the “Fault Check/Tone” button.
Mew the test status of e*ch pair as show” by the examples above. The mrious test result status
indications are es follows:
cl@~,OANDO
OPEN SHORT FAILCROSS SPLIT PASS
Note: An indication of “Cross” means the pairs are either swapped, transposed, crossed with
anotherpair or has one wire of the pair swapped wifh a wire of anotherpeir A “Split”
indicates split peir : one wire of one p&is switched with one wire of anotherpair,
occurring et both ends of the cable, but is still wired through on a f-to-l basis. Sp/it Pair
is an indication of excessive ems+-talk (noise) due to unmatchedpairs.
TONE mode for pair identification, cable tracing, and troibleshooting:
1. Connect the main tester to the hub using a patch cord. Connect the remote unit to the
wall jack using a patch cord. If testing cables, attech units directly to cable ends.
2. P,, m = @POWER ~mt~
Remote bdiudo”*
‘or a (load STP cable
CEd - mU
3. Press
= @ @ @ @ @ “ALL ON” + @ “ON” (Cable Good,
“2 M 4l* 7B SHD
PASS
COAX
OR
4. Test complete. Go to the next cable tesr or perform * “Fault Check” opentio”
:&-~$y
llrlz 1
to troubleshoot ‘*“My cables. Do not press the “OWTEST” button. This will turn
off the tester and prevent a “Fault Check” from being performed.
Testing COAXIAL Cables:
1. Connect the main tester to the hub using * patch cord. Connect the remote unit to the
wall jack using a patch cord. ,ftesti”g cables, attach units directly to cable ends.
Remote I”diClSD”.
‘0. a good coax cable
i 0 @ “COAXISHD” +
“ON” (Cable Gocd, &>
I,,,ef7,;gji
OR
/ yyp i
112 316 us 118 SHD FAIL I [~gy(fjJ I
co.,
OR
= %t!E~
!:,Tzi l,,*ii
“ON/FLASH” + @ “ON” (open-s&) &&“-“.,.k&
FAIL
4. Test complete.
Go
to
the next cable test or perform * “Fault Check” operation
to troubleshoot faulty cables. Do not press the “ON/TEST” button. This will turn
off th* tester and prevent a “Fault Check” from being performed.
ExamDIes of faultv cable indications on the remote units:
The remotes
will only show
lights for pairs
without faults
1. An oscillating audio tone i6 *e,ective,y applied to individual pairs or all Ii”** for tracing.
2. Pr*** /@I =
“Tone Applied to Pair 112”
= p3?3g
“ToneApplied to Pair 316”
4. Press
= Q$33g
“Tone Applied to Pair 46 or COAX Center Conductor”
5. PresI pig = =_
EQE
“Tone Applied to Pair 718”
s. Pm* @ = ,,1 ,,6 z ,~ *“”
@ @ @ @ @ “Tone Applied to A,, P&s and Shield (SHD)”
Note: Due to the low signal output level of the tester, tone applied to individualpairs is
lower in volume (when using a tone probe to hear the signer) than when applying
the tone to a// pairs. For highest volume level to trace cables, it is recommended
to apply the tone to a// pairs (see step 6 above).
7. To trace individual pairs for troubleshooting, apply tone only to the required pair es
shown in steps 2 through 5.
3
  • Page 1 1
  • Page 2 2

Legrand UTP/Coax Cable Tester w/Remote, IS-0082 Installation guide

Category
Cable network testers
Type
Installation guide

Legrand UTP/Coax Cable Tester w/Remote, IS-0082 is a handheld device designed to test the integrity and continuity of UTP (unshielded twisted pair), STP (shielded twisted pair), and coaxial cables commonly used in structured cabling networks.

It can perform a variety of tests, including continuity, shorts, opens, crossed connections, transposed pairs, and split pairs. The tester can also generate an oscillating audio tone for tracing cables and identifying individual pairs within a cable bundle.

To use the tester, simply connect one end of the tester to one end of the cable you want to test and the other end of the tester to the other end of the cable. The tester will then perform a series of tests and display the results on its LCD screen.

Ask a question and I''ll find the answer in the document