Waeco AirCon Service Disinfection device, WAECO AirCon Service Disinfection device Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Waeco AirCon Service Disinfection device Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Europe
WAECO Schweiz AG
Riedackerstrasse 7a
CH-8153 Rümlang (Zürich)
Fon: +41 44 8187171
Fax: +41 44 8187191
WAECO Danmark A/S
Tværvej 2
DK-6640 Lunderskov
Fon: +45 75585966
Fax: +45 75586307
E-Mail: waeco@waeco.dk
WAECO Ibérica S.A.
Camí del Mig, 106
Poligono Industrial Les Corts
E-08349 Cabrera de Mar
(Barcelona)
Fon: +34 93 7502277
Fax: +34 93 7500552
WAECO Distribution SARL
ZAC 2 · Les Portes de L‘Oise
Rue Isaac Newton – BP 59
F-60230 Chambly (France)
Fon: +33 1 30282020
Fax: +33 1 30282010
WAECO Finland OY
Mestarintie 4
FIN-01730 Vantaa
Fon: +358 20 7413220
Fax: +358 9 7593700
WAECO Italcold SRL
Via dell’Industria 4/0
I-40012 Calderara di Reno (BO)
Fon: +39 051 727094
Fax: +39 051 727687
WAECO Norge AS
Leif Weldingsvei 16
N-3208 Sandefjord
Fon: +47 33428450
Fax: +47 33428459
E-Mail: firmapost@waeco.no
WAECO Benelux B.V.
Ecustraat 3
NL-4879 NP Etten-Leur
Fon: +31 76 5029000
Fax: +31 76 5029090
E-Mail: verkoop@waeco.nl
WAECO Svenska AB
Gustaf Melins gata 7
S-42131 Västra Frölunda
(Göteborg)
Fon: +46 31 7341100
Fax: +46 31 7341101
WAECO UK Ltd.
Dorset DT2 8LY · Unit G
Roman Hill Business Park
UK-Broadmayne
Fon: +44 1305 854000
Fax: +44 1305 854288
CH
DK
E
F
FIN
I
N
NL
S
UK
Overseas + Middle East
WAECO Pacific Pty. Ltd.
1 John Duncan Court
Varsity Lakes QLD 4227
Fon: +61 7 55076000
Fax: +61 7 55221003
WAECO Impex Ltd.
Headquarters
Suites 3210-12 · 32/F · Tower 2
The Gateway · 25 Canton Road
Tsim Sha Tsui · Kowloon
Hong Kong
Fon: +852 2 4632750
Fax: +8 52 24639067
WAECO Impex Ltd.
Taipei Office
2 FL-3 · No. 56 Tunhua South Rd, Sec 2
Taipei 106, Taiwan
Fon: +886 2 27014090
Fax: +886 2 27060119
E-Mail: marketing@waeco.com.tw
WAECO Middle East FZCO
R/A 8, SD 6
Jebel Ali, Dubai
Fon: +971 4 8833858
Fax: +971 4 8833868
E-Mail: waeco@emirates.net.ae
WAECO USA, Inc.
8 Heritage Park Road
Clinton, CT 06413
Fon: +1 860 6644911
Fax: +1 860 6644912
AUS
HK
ROC
UAE
USA
Headquarters
WAECO International GmbH · Hollefeldstraße 63 · D-48282 Emsdetten
Fon: +49 2572 879-195 · Fax: +49-2572 879-322 · E-Mail: [email protected] · Internet: www.waeco.de
D
www.airconservice.de
Disinfection device
8885300088
DE 3 Ultraschallvernebler
Bedienungsanleitung
EN 10 Ultrasonic nebuliser
Instruction Manual
FR 17 Nébuliseur à ultrasons
Notice d’emploi
ES 24 Pulverizador ultrasónico
Instrucciones de uso
IT 32 Nebulizzatore ad ultrasuoni
Istruzioni per l’uso
DA 39 Ultralydforstøver
Betjeningsanvisning
SV 46 Ultraljuds-spridare
Bruksanvisning
NO 53 Ultralydfortåker
Bruksanvisning
FI 60 Ultraaänisumutin
Käyttöohjeet
3.01.06.01504 03/2006
TITELBREIT.fm Seite 1 Donnerstag, 2. März 2006 3:22 15
Disinfection device
1
1
3
2
4
2
3 4
5
TITELBREIT.fm Seite 2 Donnerstag, 2. März 2006 3:22 15
Notes on using the manual Disinfection device
10
Please read this operating manual carefully before starting the device. Keep it
in a safe place for future reference. If the device is to be resold, this operating
manual must be handed over to the purchaser along with it.
Contents
1 Notes on using the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5 Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
8 Cleaning and care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
10 Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
11 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
12 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1 Notes on using the manual
The following symbols are used in this operating manual:
Caution
Safety instruction: failure to observe this instruction can cause personal
injury or damage the device.
Warning
Safety instruction relating to a danger from an electrical current or voltage.
Failure to observe this instruction can cause damage to the device and
personal injury and impair the function of the device.
Note:
Supplementary information for operating the device.
Action: This symbol indicates that action is required on your part. The required
action is described step-by-step.
This symbol describes the result of an action.
Please observe the following safety instructions.
Desinfektionsgeraet.book Seite 10 Donnerstag, 2. März 2006 3:09 15
Disinfection device Safety instructions
11
2 Safety instructions
2.1 General safety
z Use only the connection cable to connect the device to the AC mains.
z Never pull the plug out of the socket by the cable.
z Do not operate the disinfection device if the device or the cable are damaged.
z This appliance may only be repaired by qualified personnel. Inadequate repairs
can lead to considerable hazards.
Should your appliance need to be repaired, please contact WAECO customer
service.
z Disconnect the connection cable:
Before cleaning and maintenance
After use
z Check that the voltage specification on the type plate corresponds to that of the
energy supply.
2.2 Operating the appliance safely
z Only use disinfectants approved by WAECO
(Disinfectant, item no.: 8887400012).
z Never operate the the device without liquid.
z Before starting the device, ensure that the power supply line and the plug are dry.
z Do not breathe in disinfectant spray.
Get out of the vehicle during spraying.
z Never immerse the device in water.
z Do not clean plastic parts with solvents or corrosive substances.
z Never expose the device to rain or moisture.
z Protect the device and the power cable against heat and moisture.
z WAECO cannot be held liable for damage resulting from improper usage or
incorrect operation.
Desinfektionsgeraet.book Seite 11 Donnerstag, 2. März 2006 3:09 15
Scope of delivery Disinfection device
12
3 Scope of delivery
Fig. 1: Scope of delivery
4 Accessories
Chemical agent for the disinfectant device:
z For cleaning the air-conditioner
z For reducing germs in the vehicle interior
Produced by WAECO, available from your dealer or directly from WAECO.
5 Spare parts
6 Description
6.1 Intended use
Caution
Also follow any other cleaning regulations which apply. The disinfec-
tion device is only intended to assist your other cleaning work, not to
replace it.
The disinfection device is an ultrasonic spraying device for reducing germs in air
conditioning evaporators and vehicle interiors (for example in emergency vehicles).
Quantity Description
1 Disinfection device (1)
1 Case (2)
1 Power cable (3)
1 Hose (4)
Disinfectant Item no.: 8887400012
Hose Item no.: 8885400093
Power supply with 10 m cable Item no.: 8885400094
Case Item no.: 8885400095
Desinfektionsgeraet.book Seite 12 Donnerstag, 2. März 2006 3:09 15
Disinfection device Operation
13
6.2 Function description
The ultrasonic cells diffuse the disinfectant into a fine spray. The spray is directed
through the hose by a fan to the suction openings of the evaporator or the inside of
the vehicle.
The disinfection device switches off automatically when the fluid reaches a minimum
level or the temperature exceeds 35 °C.
7Operation
7.1 Cleaning the air-conditioning evaporator
Note:
Only use disinfectant supplied by WAECO.
The disinfection device works best at temperatures between 0 and 35 °C.
Fig. 2: Preparing the disinfection device
Caution
Observe the safety instructions on the packaging of the disinfectant.
Shake the disinfectant well.
Open the lid and pour in disinfectant up to the maximum filling level indicator (red
mark) on the disinfection device.
Note:
Do not over-fill the device.
Close the door.
Plug in the hose completely.
Fig. 3: Setting up the disinfection device
Set up the disinfection device upright, firmly standing on the air conditioning
evaporator.
Place the hose near the intake opening of the ventilation system.
Selecting air conditioning settings
Settings:
Set the temperature control to the lowest level.
Set the blower to the highest level.
Open the air outlets for the air conditioning.
Set to ventilation.
Switch on the air conditioning.
Desinfektionsgeraet.book Seite 13 Donnerstag, 2. März 2006 3:09 15
Operation Disinfection device
14
Fig. 4: Starting the cleaning procedure
Connect the disinfection device to the power supply (1).
Get out of the vehicle and close the doors.
Caution!
Do not damage the power cable.
Do not inhale the spray.
Allow the air-circulation/automatic air-conditioning system to run for about
20 minutes.
Note:
The disinfection device stops automatically when the liquid reaches a
minimum level.
Ending the cleaning procedure
Disconnect from the mains (2).
Let the disinfectant act for 30 minutes.
Ventilating the vehicle
Open all vehicle doors and switch off the blower and the air-conditioning.
Allow the interior of the vehicle to ventilate for 30 minutes.
After the cleaning procedure, leave the blower running for more than
10 minutes to dry the vaporiser.
7.2 Cleaning the interior
Note:
Only use disinfectant supplied by WAECO.
Use the disinfection device to clean the interior of your vehicle as described in "Clean-
ing the air-conditioning evaporator" on page 13.
Set up the disinfection device without a hose, facing the interior of the vehicle.
Connect the disinfection device to the power supply. Get out of the vehicle and
close the doors.
Caution!
Do not damage the power cable.
Do not inhale the spray.
The disinfection device stops automatically after around 20 minutes when the
liquid reaches a minimum level.
Disconnect from the mains.
Let the disinfectant act for 30 minutes.
Open all vehicle doors and allow the vehicle interior to air for approx. 30 minutes.
Desinfektionsgeraet.book Seite 14 Donnerstag, 2. März 2006 3:09 15
Disinfection device Cleaning and care
15
8 Cleaning and care
Fig. 5: Cleaning
Disconnect from the mains.
Remove the hose.
Empty any remaining fluid.
Rinse out with distilled water.
9 Troubleshooting
No spray formation
z Too little fluid in the disinfection device.
z The ultrasonic cell is defective.
z The fan is defective.
z Fault in the connection to the transformer.
Liquid leaks out of the device
z Too much disinfectant in the device.
z The container is overflowing because the device is standing on a severe slope.
10 Guarantee
The statutory warranty period applies. If the product is defective, please send it back
to the WAECO branch in your country (addresses on the back of the operating
manual) or to your dealer. For repair and guarantee processing, the following
documents must be sent along with the device:
z A copy of the receipt with purchasing date
z A reason for the claim or description of the fault
11 Disposal
Take the packaging material for recycling.
If you need to scrap the device, ask your local recycling centre or specialist
dealer for details about how to do this in accordance with the applicable dis-
posal regulations.
Desinfektionsgeraet.book Seite 15 Donnerstag, 2. März 2006 3:09 15
Technical data Disinfection device
16
12 Technical data
Versions, technical modifications and delivery options reserved.
Dimensions: 138 x 310 x 285 mm (H x W x D)
Voltage: 220 V AC, 50 Hz
Input voltage: 24 V AC
Operating temperature: 0 – 35 °C
Testing/certification:
Desinfektionsgeraet.book Seite 16 Donnerstag, 2. März 2006 3:09 15
/