Cisco UCSC-PCIE-Q2672 Datasheet

Category
Networking cards
Type
Datasheet

This manual is also suitable for

CISCO SYSTEMS PUBLICATION HISTORY
170 W
EST TASMAN DR.
S
AN JOSE, CA, 95134 REV B.7 JANUARY 5, 2015
WWW.CISCO.COM
Spec Sheet
Cisco UCS C24 M3
High-Density
Large Form Factor
Rack-Mount Server
Cisco UCS C24 M3 High-Density LFF Rack-Mount Server
2
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 6
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
STEP 1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
STEP 2 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
STEP 3 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
STEP 4 SELECT RAID CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
STEP 5 SELECT HARD DISK DRIVES (HDDs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
STEP 6 SELECT PCIe OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . 24
STEP 8 SELECT AC POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
STEP 9 ORDER POWER SUPPLIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . . . . . . . . . . . . . . . . . 32
STEP 11 ORDER A TRUSTED PLATFORM MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
STEP 12 ORDER OPTIONAL USB 2.0 DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 35
STEP 14 SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
STEP 15 SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
CPUs and DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Physical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Memory Population Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Recommended Memory Population . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Additional DIMM Populations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Low-Voltage DIMM Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
RAID Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
RAID Option ROM (OPROM) Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Motherboard USB Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Compliance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Cisco UCS C24 M3 High-Density LFF Rack Server
OVERVIEW
3
OVERVIEW
The Cisco® UCS C24 M3 Rack Server combines economics and a density-optimized feature set from entry
level enterprise to SMB with applications such as scale out, virtualization, IT and web infrastructure, VPN
servers, file/print servers, and appliances.
Building on the success of the Cisco UCS C-Series Rack Servers, the Cisco UCS C24 M3 rack server and the
Cisco 1225 VIC further extend the capabilities of the Cisco UCS portfolio in a 2 RU form factor with the
Intel® Xeon® E5-2400 v2 and E5-2400 series processor family CPUs, which deliver the best combination of
performance, flexibility, and efficiency gains. In addition, the Cisco UCS C24 M3 offers up to 12 DIMM slots,
12 disk drives, 5 PCIe slots, and two 1 Gigabit Ethernet LAN-on-motherboard (LOM) ports to provide
exceptional levels of internal storage and price/performance.
Figure 1 Cisco UCS C24 M3 High-Density LFF Rack Server
Front View
Rear View
Cisco UCS C24 M3 High-Density LFF Rack Server
4
DETAILED VIEWS
DETAILED VIEWS
Chassis Front View
Figure 2 shows the Cisco UCS C24 M3 High-Density LFF Rack Server.
Figure 2 Chassis Front View
1 USB 2.0 ports (two) 4 Status LEDs (top to bottom):
Network activity LED
Power supply status LED
Te m p er a t u r e s t a t u s L ED
Fan Status LED
System status LED
2 Pull-out asset tag 5 Identification button/LED
3 Drives, hot-swappable (up to twelve
3.5-inch drives
6 Power button/power status LED
HDD01
HDD05
HDD09
HDD02
HDD06
HDD10
HDD03
HDD07
HDD11
HDD04
HDD08
HDD12
285249
5
2
6
1
4
3
Cisco UCS C24 M3 High-Density LFF Rack Server
DETAILED VIEWS
5
Chassis Rear View
Figure 3 shows the external features of the rear panel.
Figure 3 Chassis Rear View
1 Power supplies (two) 6 VGA video port (DB-15 connector)
2 Dual 1 Gb Ethernet ports (LAN1, LAN2) 7 10/100/1000 Ethernet dedicated
management port
3 PCIe Gen 3 half-height slots 3, 4, and 5 on
riser 2
Slot 3: x8 half-height, half-length
Slot 4: x8 half-height, half-length
Slot 5: x8 half-height, half-length
8 Rear Identification button/LED
4 USB ports (4) 9 PCIe Gen 3 full-height slots 1 and 2 on riser 1
Slot 1: x16 extended connector (Cisco
CNIC), full-height, 3/4-length,
Slot 2: x4 full-height, one-half length
5 Serial port (DB-9 connector) - -
PSU 2PSU 2PSU 2
PCIe 4
PCIe 4PCIe 4
PCIe 3PCIe 3PCIe 3 PCIe 1PCIe 1PCIe 1
PCIe 2
PCIe 2PCIe 2
PCIe 5
PCIe 5PCIe 5
PSU 1
PSU 1PSU 1
1 32 4 5 6 7 8 9
343735
Cisco UCS C24 M3 High-Density LFF Rack Server
6
BASE SERVER STANDARD CAPABILITIES and FEATURES
BASE SERVER STANDARD CAPABILITIES and FEATURES
Tab le 1 lists the capabilities and features of the base server. Details about how to configure the server for
a particular feature or capability (for example, number of processors, disk drives, or amount of memory)
are provided in
CONFIGURING the SERVER, page 8.
Table 1 Capabilities and Features
Capability/Feature Description
Chassis Two rack unit (2RU) chassis
CPU One or two Intel® Xeon E5-2400 v2 or E5-2400 series processor family CPUs
Chipset Intel C600 chipset
Memory 12 DIMM slots
NIC Embedded dual-port Intel I350 PCIe-based Gigabit Ethernet controller
Expansion slots Two riser cards containing PCIe card slots
Riser 1 (slots 1 and 2, controlled by CPU 1)
Slot 1: PCIe Gen 3 slot, x16 extended connector (Cisco CNIC),
3/4-length, full-height, with NCSI
1
and Cisco CNIC
2
support. The
Cisco 1225 virtual interface cards require an NCSI slot.
• Slot 2: PCIe Gen 3 slot, x4 connector, half-length, full-height, no NCSI
support
Riser 2 (slots 3, 4, and 5, controlled by CPU 2)
Slot 3:PCIe Gen 3 slot, x8 connector, half-length, half-height
Slot 4: PCIe Gen 3 slot, x8 connector, half-length, half-height
Slot 5: PCIe Gen 3 slot, x8 connector, half-length, half-height
Storage controller PCIe RAID controller card options (these consume PCIe slots):
LSI MegaRAID 9270CV-8i with 1 GB Transportable Memory Module
(TMM) data cache and chassis-mounted (remote) supercap for data
cache power backup, supporting RAID 0, 1, 5, 6, 10, 50, and 60 and
up to 12 internal SAS+SATA drives.
LSI MegaRAID 9240-8i RAID 8-port PCIe RAID controller, supporting
RAID 0, 1, 5, 10, and 50 and up to 12 internal SAS+SATA drives.
LSI MegaRAID 9220-8i RAID 8-port PCIe RAID controller supporting RAID
0, 1, and 10 and up to 12 internal SAS+SATA drives.
Internal storage devices Up to 12 3.5-inch SAS+SATA hot-swappable hard disk drives (HDDs) are
supported
One connector on the motherboard that can accommodate a USB 2.0
drive. You can order an 8 or 16 GB drive for this connector and use it as
a hypervisor or license dongle. The 8 or 16 GB USB drive comes blank.
Cisco UCS C24 M3 High-Density LFF Rack Server
BASE SERVER STANDARD CAPABILITIES and FEATURES
7
Video The Emulex Pilot 3 Integrated Baseboard Management Controller provides
video:
Matrox G200e video controller
Integrated 2D graphics core with hardware acceleration
Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at
60 Hz
24-bit color depth for all resolutions less than 1600x1200
8 MB video memory
Interfaces Rear panel
One DB9 serial port connector
Four USB 2.0 port connectors
One DB15 VGA connector
One 10/100/1000 Ethernet management port
Two 1 GbE (10/100/1000 Mbps capable) Ethernet LOM ports
Front panel
•Two USB 2.0 ports
Front Panel A front panel controller provides status indications and control buttons
Power subsystem One or two power supplies, depending on server configuration and loading.
Power supplies available are 450 W or 650 W (no mixing). With two power
supplies, 1 + 1 redundancy is provided if the load can be carried with one
supply. Prior to making a power supply selection, the UCS Power Calculator
should be run to determine the right size power supply for your server
configuration. The UCS Power Calculator can be found at the following link:
https://mainstayadvisor.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
Fans Chassis:
Four hot-swappable fans for front-to-rear cooling. N + 1 redundant.
Power supply:
The power supplies are equipped with fans.
Integrated management
processor
Cisco Integrated Management Controller (CIMC).
Depending on your CIMC settings, the CIMC can be accessed through the 1-Gb
Ethernet dedicated management port, the 1-Gb Ethernet LOM ports, or a
Cisco 1225 virtual interface card.
Notes . . .
1. NCSI = network communications services interface protocol. The slot stays active when the server is in standby
power state.
2. CNIC = Cisco network interface card.
Capability/Feature Description
Cisco UCS C24 M3 High-Density LFF Rack Server
8
CONFIGURING the SERVER
CONFIGURING the SERVER
Follow these steps to configure the Cisco UCS C24 M3 High-Density LFF Rack Server:
STEP 1 VERIFY SERVER SKU, page 9
STEP 2 SELECT CPU(s), page 10
STEP 3 SELECT MEMORY, page 12
STEP 4 SELECT RAID CONFIGURATION, page 16
STEP 5 SELECT HARD DISK DRIVES (HDDs), page 20
STEP 6 SELECT PCIe OPTION CARD(s), page 22
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 23
STEP 8 SELECT AC POWER CORD(s), page 28
STEP 9 ORDER POWER SUPPLIES, page 31
STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM, page 32
STEP 11 ORDER A TRUSTED PLATFORM MODULE, page 33
STEP 12 ORDER OPTIONAL USB 2.0 DRIVES, page 34
STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 35
STEP 14 SELECT OPERATING SYSTEM MEDIA KIT, page 38
STEP 15 SELECT SERVICE and SUPPORT LEVEL, page 39
OPTIONAL STEP - ORDER RACK(s), page 44
OPTIONAL STEP - ORDER PDU, page 45
Cisco UCS C24 M3 High-Density LFF Rack Server
CONFIGURING the SERVER
9
STEP 1 VERIFY SERVER SKU
The 12-drive version of the server has a SAS expander enabled backplane that supports up to 12
hard disk drives with a single RAID card.
Verify the product ID (PID) of the server as shown in Table 2.
The Cisco C24 M3 server:
Includes a rail kit (UCSC-RAIL1)
Does not include power supply, CPU, memory, hard disk drives (HDDs), or plug-in PCIe cards.
Table 2 PID of the C24 M3 High-Density LFF Rack Base Server
Product ID (PID) Description
UCSC-C24-M3L UCS C24 M3 LFF with rail kit, without PSU, CPU, memory, HDD, or PCIe cards
NOTE: Use the steps on the following pages to configure the server with
the components that you want to include.
Cisco UCS C24 M3 High-Density LFF Rack Server
10
CONFIGURING the SERVER
STEP 2 SELECT CPU(s)
The standard CPU features are:
Intel Xeon E5-2400 v2 or E5-2400 series processor family CPUs
Intel C600 chipset
Cache size of up to 25 MB
Select CPUs
The available CPUs are listed in Table 3.
Table 3 Available Intel CPUs: Xeon E5-24xx Series
Product ID (PID)
Intel
Number
Clock
Freq
(GHz)
Power
(W)
Cache
Size
(MB)
Cores
QPI
(GT/s)
Highest DDR3
DIMM Clock
Support (MHz)
1
Notes . . .
1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be
clocked at the lowest common denominator of CPU clock and DIMM clock.
Intel Xeon E5-2400 v2
UCS-CPU-E52470B E52470 v2 2.4 95 25 10 8.0 1600
UCS-CPU-E52450B E52450 v2 2.5 95 20 8 8.0 1600
UCS-CPU-E52440B E52440 v2 1.9 95 20 8 7.2 1600
UCS-CPU-E52430B E52430 v2 2.5 80 15 6 7.2 1600
UCS-CPU-E52430LB E52430L v2 2.4 60 15 6 7.2 1600
UCS-CPU-E52420B E52420 v2 2.2 80 15 6 7.2 1600
UCS-CPU-E52407B E52407 v2 2.4 80 10 4 6.4 1333
UCS-CPU-E52403B E52403 v2 1.8 80 10 4 6.4 1333
Intel Xeon E5-2400
UCS-CPU-E5-2470 E5-2470 2.30 95 20 8 8.0 1600
UCS-CPU-E5-2450 E5-2450 2.10 95 20 8 8.0 1600
UCS-CPU-E5-2440 E5-2440 2.40 95 15 6 7.2 1333
UCS-CPU-E5-2430 E5-2430 2.20 95 15 6 7.2 1333
UCS-CPU-E5-2430L E5-2430L 2.00 60 15 6 6.4 1333
UCS-CPU-E5-2420 E5-2420 1.90 95 15 6 7.2 1333
UCS-CPU-E5-2407 E5-2407 2.20 80 10 4 6.4 1066
UCS-CPU-E5-2403 E5-2403 1.80 80 10 4 6.4 1066
Cisco UCS C24 M3 High-Density LFF Rack Server
CONFIGURING the SERVER
11
Approved Configurations
(1) 1-CPU configurations:
Select any one CPU listed in Table 3.
(2) 2-CPU Configurations:
Select two identical CPUs from any one of the rows of Table 3.
Caveats
Select one or two identical CPUs.
If you select one CPU, only PCIe slots 1 and 2 are available for use.
For optimal performance, select DIMMs with the highest clock speed for a given processor
(see
Tab le 3 on page 10). If you select DIMMs whose speeds are lower or higher than that
shown in the tables, suboptimal performance will result.
Cisco UCS C24 M3 High-Density LFF Rack Server
12
CONFIGURING the SERVER
STEP 3 SELECT MEMORY
The standard memory features are:
DIMMs
Clock speed: 1600 or 1333 MHz
Ranks per DIMM: 1, 2, or 4
Operational voltage: 1.5 V or 1.35 V
Registered ECC DDR3 DIMMS (RDIMMS), unregistered DIMMs (UDIMMs), and
load-reduced DIMMs (LRDIMMs)
Memory is organized with three memory channels per CPU, with up to two DIMMs per
channel, as shown in
Figure 4.
Figure 4 C24 M3 LFF Memory Organization
Cisco UCS C24 M3 High-Density LFF Rack Server
CONFIGURING the SERVER
13
Select DIMMs
Select the memory configuration. The available memory DIMMs are listed in Table 4.
Approved Configurations
(1) 1-CPU configuration without memory mirroring:
Select from 1 to 6 DIMMs. Refer to Memory Population Rules, page 48, for more detailed
information.
NOTE: When memory mirroring is enabled, the memory subsystem simultaneously
writes identical data to two channels. If a memory read from one of the channels
returns incorrect data due to an uncorrectable memory error, the system
automatically retrieves the data from the other channel. A transient or soft error in
one channel does not affect the mirrored data, and operation continues unless there
is a simultaneous error in exactly the same location on a DIMM and its mirrored
DIMM. Memory mirroring reduces the amount of memory available to the operating
system by 50% because only one of the two populated channels provides data.
Table 4 Available DDR3 DIMMs
Product ID (PID) PID Description Voltage
Ranks/
DIMM
DIMM Options
UCS-MR-1X041RY-A 4GB DDR3-1600-MHz RDIMM/PC3-12800/1R/x4/1.35v 1.35 V 1
UCS-MR-1X082RY-A 8GB DDR3-1600-MHz RDIMM/PC3-12800/2R/x4/1.35v 1.35 V 2
UCS-MR-1X162RY-A 16GB DDR3-1600-MHz RDIMM/PC3-12800/2R/x4/1.35v 1.35 V 2
UCS-ML-1X324RY-A 32GB DDR3-1600-MHz LR DIMM/PC3-12800/4R/x4/1.35v 1.35 V 4
Memory Mirroring Option
N01-MMIRROR Memory mirroring option
Cisco UCS C24 M3 High-Density LFF Rack Server
14
CONFIGURING the SERVER
(2) 1-CPU configuration with memory mirroring:
Select 2 or 4 DIMMs. The DIMMs will be placed by the factory as shown in the following table:
(3) 2-CPU configuration without memory mirroring:
Select from 1 to 6 DIMMs per CPU (2 to 12 DIMMs total). Refer to Memory Population Rules,
page 48, for more detailed information.
(4) 2-CPU configuration with memory mirroring:
Select 2 or 4 DIMMs per CPU (4 or 8 DIMMs total). The DIMMs will be placed by the factory as
shown in the following table
:
Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 13.
Caveats
Do not mix 1333-MHz with 1600-MHz DIMMs
Do not mix DIMM types (RDIMM, LRDIMM, or UDIMM)
Do not select more than two different sizes of DIMMs (only two PID sizes allowed)
For the 2-CPU configuration, install a minimum of 2 DIMMs (one per CPU).
If you use different sizes of DIMMs, the quantity of each size of DIMM must be even (2, 4, or
6). For example, 4 UCS-MR-1X082RY-A DIMMs and 6 UCS-MR-1X162RY-A DIMMs. Also, the sum
of all PIDs must adhere to the maximum quantity rule of 12 DIMMs for 2-CPU systems.
Number of
DIMMs
DIMM Placement
(Channel A is not used with memory mirroring)
2 CPU 1: 1 DIMM in Channel B, 1 DIMM in Channel C
4 CPU 1: 2 DIMMs in Channel B, 2 DIMMs in Channel C
Number of
DIMMs per
CPU
DIMM Placement
(Channels A and D are not used with memory mirroring)
2 CPU 1:
1 DIMM in Channel B
1 DIMM in Channel C
CPU 2:
1 DIMM in Channel E
1 DIMM in channel F
4 CPU 1:
2 DIMMs in Channel B
2 DIMMs in Channel C
CPU 2:
2 DIMMs in Channel E
2 DIMMs in Channel F
NOTE: System performance is optimized when the DIMM sizes and quantities are
equal for both CPUs.
Cisco UCS C24 M3 High-Density LFF Rack Server
CONFIGURING the SERVER
15
By default, all DIMMs run at 1.35 V, which yields 1333-MHz memory speeds. To run the
memory DIMMS at 1600 MHz, you need to go into the BIOS or set the policy with UCSM
(service profile) to run in Performance Mode. This forces the DIMMs to operate at 1.5 V and
yields 1600-MHz speeds, provided:
The DIMMs are 1600-MHz devices
The CPUs chosen support 1600-MHz operation.
For more information regarding memory, see CPUs and DIMMs, page 47.
NOTE: 32 GB LRDIMMs run at a maximum speed of 1333 MHz for 1 DPC and 2 DPC
even though their specified maximum speed is 1600 MHz.
NOTE: In this server, 4 GB UDIMMs run slower than their specified maximum speed of
1600 MHz. In addition, the following rules apply to UDIMMs:
1 DPC: 1333 MHz is supported at 1.35 V and 1.5 V
2 DPC: 1066 MHz is supported at 1.35 V and 1.5 V
Cisco UCS C24 M3 High-Density LFF Rack Server
16
CONFIGURING the SERVER
STEP 4 SELECT RAID CONFIGURATION
(1) One PCIe RAID controller
Cisco can provide factory-configured RAID systems depending on the RAID controller chosen and
the number of drives ordered. Factory-configured RAID options are listed in
Tab le 5 along with
each RAID card description. RAID levels 50 and 60 are supported, although they are not available
as factory-configured RAID options.
Select RAID Controller Options
Select one RAID controller and an appropriate RAID configuration option listed in Table 5.
NOTE: When creating a RAID volume, follow these guidelines:
Use the same capacity for each drive in the volume
Use either all SAS drives or all SATA drives
Use either all HDDs or all SSDs
NOTE: The number of RAID groups (virtual drives) supported per controller is as
follows:
LSI MegaRAID SAS 9270CV-8i RAID controller card = 64
LSI MegaRAID 9240-8i RAID controller card = 16
LSI MegaRAID 9220-8i RAID controller card = 16
Table 5 Available PCIe RAID Controller Options
Product ID (PID) PID Description
RAID Controllers
(note that for 12-drive backplane systems, PCIe RAID controllers are installed by default in slot 2 for
1-CPU systems and slot 4 for 2-CPU systems)
UCSC-RAID-9240-8I LSI MegaRAID 9240-8i
Supports up to 12 internal SAS+SATA drives.
RAID levels supported: RAID 0, 1, 5, 10, 50 (see the RAID Configuration
Options section later in this table)
UCSC-RAID-9220-8I LSI MegaRAID 9220-8i
Supports up to 12 internal SAS+SATA drives.
RAID levels supported: RAID 0, 1, 10 (see the RAID Configuration Options
section later in this table)
Cisco UCS C24 M3 High-Density LFF Rack Server
CONFIGURING the SERVER
17
UCS-RAID9270CV-8i LSI MegaRAID 9270CV-8i (with supercap power backup)
Supports up to 12 internal SAS+SATA drives.
Includes a 1 GB Transportable Memory Module (TMM) cache and
chassis-mount (remote) supercap power module for data cache backup
RAID levels supported: RAID 0, 1, 5, 6, 10, 50, 60 (see the RAID
Configuration Options section later in this table)
RAID Configuration Options
R2XX-RAID0 Factory preconfigured RAID striping option
Enable RAID 0 Setting. Requires a minimum of one hard drive.
R2XX-RAID1 Factory preconfigured RAID mirroring option
Enable RAID 1 Setting. Requires exactly two drives with the same size, speed,
capacity.
R2XX-RAID5 Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of three drives of the same size,
speed, capacity.
R2XX-RAID6 Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of four drives of the same size,
speed, capacity.
R2XX-RAID10 Factory preconfigured RAID option
Enable RAID 10 Setting. Requires an even number of drives (minimum of four
drives) of the same size, speed, capacity.
NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are
supported for selected controllers as shown in
Table 5.
Table 5 Available PCIe RAID Controller Options (continued)
Product ID (PID) PID Description
Cisco UCS C24 M3 High-Density LFF Rack Server
18
CONFIGURING the SERVER
Approved Configurations
(1) 1-CPU Configurations
Select a PCIe RAID controller from Table 5 on page 16. You may also select an appropriate
optional RAID configuration listed in Table 5 on page 16.
(2) 2-CPU Configurations
Select a PCIe RAID controller from Table 5 on page 16. You may also select an appropriate
optional RAID configuration listed in Table 5 on page 16.
Caveats
For 1-CPU systems
PCIe slots 3, 4, and 5 are not supported.
The only supported RAID option for a 12 HDD backplane system is a PCIe RAID
controller, and the default slot is slot 2; however, you can go into the BIOS and
change the option ROM (OPROM) setting to enable a different slot for an internal
drive RAID controller.
If a PCIe RAID controller is not installed, both slots 1 and 2 may be used for any
other PCIe expansion cards.
For 2-CPU configurations:
All PCIe slots (1, 2, 3, 4, and 5 are supported).
The only supported RAID option for a 12 HDD backplane system is a PCIe RAID
controller, and the default slot is slot 4; however, you can go into the BIOS and
change the option ROM (OPROM) setting to enable a different slot for an internal
drive RAID controller. Any remaining slot can then be used for a PCIe expansion
card.
If a PCIe RAID controller is not installed, all of the PCIe slots may be used for any
other PCIe expansion cards.
You can choose an optional RAID configuration (RAID 0, 1, 5, 6, or 10), which is
preconfigured at the factory. The RAID level you choose must be an available RAID choice for
NOTE: In 1-CPU configurations, PCIe slot 2 is the default slot supported for an
internal drive RAID controller. PCIe slots 3, 4, and 5 are not supported for 1-CPU
systems. You can change the default card slot for a RAID controller to a different slot
(slot 1) by going into the BIOS and reconfiguring the option ROM (OPROM) settings.
NOTE: In 2-CPU configurations, PCIe slot 4 is the default slot supported for an
internal drive RAID controller. You can change the default card slot for a RAID
controller to a different slot by going into the BIOS and reconfiguring the option ROM
(OPROM) settings.
Cisco UCS C24 M3 High-Density LFF Rack Server
CONFIGURING the SERVER
19
the controller selected. RAID levels 50 and 60 are supported, depending on the RAID
controller selected, although they are not available as configuration options
Note that only a single Cisco 1225 Virtual Interface Card (VIC) card is supported and it must
be installed in the 3/4-length, full-height PCIe slot (slot 1) on riser 1, which is the only slot
that supports NCSI. So take this into account when populating RAID controller cards.
You can choose one PCIe RAID controller.
The 12-drive backplane system supports a maximum of one internal drive RAID controller.
NOTE: For more important information regarding RAID support, see RAID Summary,
page 52 and RAID Option ROM (OPROM) Settings, page 53.
Cisco UCS C24 M3 High-Density LFF Rack Server
20
CONFIGURING the SERVER
STEP 5 SELECT HARD DISK DRIVES (HDDs)
The standard disk drive features are:
3.5-inch large form factor
Hot-pluggable
Sled-mounted
Select Drives
The available drives are listed in Table 6.
Table 6 Available Hot-Pluggable Sled-Mounted HDDs
Product ID (PID) PID Description
Drive
Type
Capacity
HDDs
UCS-HD4T7KS3-E 4TB SAS 7.2K RPM 3.5 inch HDD SAS 4 TB
UCS-HDD3TI2F214 3TB SAS 7.2K RPM 3.5 inch HDD SAS 3 TB
UCS-HDD2TI2F213 2TB SAS 7.2K RPM 3.5 inch HDD SAS 2 TB
UCS-HDD1TI2F212 1TB SAS 7.2K RPM 3.5 inch HD SAS 1 TB
NOTE: When creating a RAID volume, follow these guidelines:
Use the same capacity for each drive in the volume
Use either all SAS drives or all SATA drives
Use either all HDDs or all SSDs
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66