Aqua Computer aquabus X4 User and Installation Manual

Type
User and Installation Manual

Aqua Computer aquabus X4 is an active quadruple aquabus splitter that allows you to connect up to four additional aquabus devices to your aquaero 5 or aquaero 6 controller. It features four aquabus connectors, each of which can support up to 32 devices, for a total of 128 possible devices. The aquabus X4 is also compatible with the Aqua Computer Real Time Clock module, allowing you to use both modules simultaneously. Installation is simple and requires no additional tools or software.

Aqua Computer aquabus X4 is an active quadruple aquabus splitter that allows you to connect up to four additional aquabus devices to your aquaero 5 or aquaero 6 controller. It features four aquabus connectors, each of which can support up to 32 devices, for a total of 128 possible devices. The aquabus X4 is also compatible with the Aqua Computer Real Time Clock module, allowing you to use both modules simultaneously. Installation is simple and requires no additional tools or software.

aquabus X4
aquabus X4
aquabus X4aquabus X4
aquabus X4
User and installation manual
User and installation manualUser and installation manual
User and installation manual
Description
DescriptionDescription
Description
Active quadruple aquabus splitter.
For operation, an aquaero 5 or aquaero 6 device with firmware version 2100 or
higher is required. Compatible firmware versions are included starting with aqua-
suite version 2018-1.
Installation onto an aquaero 5/6
Installation onto an aquaero 5/6Installation onto an aquaero 5/6
Installation onto an aquaero 5/6
The aquabus X4 is to be installed directly on top of an aquaero 5/6 device:
1. Turn off the PC, disconnect the aquaero from the PSU, disconnect the USB
cable, the standby power cable (aquaero 5 only) and aquabus high speed
cable from the aquaero if connected.
2. Remove the two screws adjacent to the temperature sensor inputs and to the
speed signal output from the aquaero.
3. Plug the aquabus X4 module onto the aquabus high speed connector of the
aquaero.
4. Secure both PCBs using the two cylindrical spacers and screws according to
the following figure. (The aquabus X4 can also be installed if a passive heat
sink is installed on the aquaero, in this case use the shorter spacers supplied
with the heat sink, replacement part number 91239.)
5. Connect aquabus high speed compatible devices to the aquabus connectors
of the aquabus X4 module. Reconnect PSU, USB and standby cables to the
corresponding connectors (if previously installed) and start the PC.
© 2018 Aqua Computer GmbH & Co. KG 94716
Gelliehäuser Str. 1, 37130 Gleichen
c
o
m
p
u
t
e
r
a
q
u
a
aquabus X4
Simultaneous use of aquabus X4 and Real Time Clock
Simultaneous use of aquabus X4 and Real Time ClockSimultaneous use of aquabus X4 and Real Time Clock
Simultaneous use of aquabus X4 and Real Time Clock
If aquabus X4 and Real Time Clock modules are to be used simultaneously, the
aquabus X4 has to be installed onto the aquaero 5/6. Install the Real Time Clock
module somewhere else in the PC and connect one of the aquabus connectors of
the aquabus X4 to one of the aquabus connectors of the Real Time Clock module.
(Compatible aquabus cables: 53122 or 53162)
Guidelines and recommendations:
Guidelines and recommendations:Guidelines and recommendations:
Guidelines and recommendations:
If used with multiple Calitemp sensors, each Calitemp sensor must be con-
nected to an individual connector of the aquabus X4 board do not con-
nect two Calitemp sensors to the same connector using splitter cables!
All other aquabus devices (such as poweradjust, mps, farbwerk, etc.) can be
connected to any connector of the aquabus X4 board in any combination,
also to ports that are connected to (exactly one) Calitemp sensor. Use
aquabus splitters (product codes 53063, 53124 or 53231) to connect mul-
tiple devices.
© 2018 Aqua Computer GmbH & Co. KG 94716
Gelliehäuser Str. 1, 37130 Gleichen
c
o
m
p
u
t
e
r
a
q
u
a
aquabus X4
The aquabus X4 board does not affect the maximum number of aquabus
devices to be connected to an aquaero. Refer to the aquaero manual for
maximum number of aquabus devices per type.
Connect a similar number of devices to each of the four aquabus connec-
tors of the aquabus X4 board for optimum performance.
Do not connect multiple aquabus X4 boards to one aquaero! For additional
aquabus connectors, use aquabus splitters (product codes 53063, 53124
or 53231).
Pin assignment
Pin assignmentPin assignment
Pin assignment
Pin 1: GND
Pin 2: SDA
Pin 3: SCL
Pin 4: +5V
Scope of delivery
Scope of deliveryScope of delivery
Scope of delivery
One aquabus X4 module
Two spacers (replacement part number 91217)
Two screws M3 x 18 mm (replacement part number 91051)
Care instructions
Care instructionsCare instructions
Care instructions
Use a dry and soft cloth for cleaning. All electronic components and headers must
not get in contact with coolant or water!
Waste disposal
Waste disposalWaste disposal
Waste disposal
This device has to be disposed of as electronic waste. Please check
your local regulations for disposal of electronic waste.
© 2018 Aqua Computer GmbH & Co. KG 94716
Gelliehäuser Str. 1, 37130 Gleichen
c
o
m
p
u
t
e
r
a
q
u
a
  • Page 1 1
  • Page 2 2
  • Page 3 3

Aqua Computer aquabus X4 User and Installation Manual

Type
User and Installation Manual

Aqua Computer aquabus X4 is an active quadruple aquabus splitter that allows you to connect up to four additional aquabus devices to your aquaero 5 or aquaero 6 controller. It features four aquabus connectors, each of which can support up to 32 devices, for a total of 128 possible devices. The aquabus X4 is also compatible with the Aqua Computer Real Time Clock module, allowing you to use both modules simultaneously. Installation is simple and requires no additional tools or software.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI