Anolis e-box series User manual

Category
Stroboscopes & disco lights
Type
User manual
1
Version 1.9
2
E-box Daisy
E-box Star
E-box Pro
E-box Lite
Table of contents
1. Safety information .......................................................................................................... 3
2. Fixture description ......................................................................................................... 4
2.1 E-box Daisy ................................................................................................................ 4
2.2 E-box Star .................................................................................................................. 6
2.3 E-box Pro ................................................................................................................... 8
2.4 E-box Lite ................................................................................................................. 10
3. Mounting ....................................................................................................................... 12
4. E-box modes ................................................................................................................. 18
5. E-box menu ................................................................................................................... 20
5.1 DMX Addr ................................................................................................................ 20
2.2 Info ........................................................................................................................... 20
5.3 Personality ............................................................................................................... 21
5.4 Test programs........................................................................................................... 22
5.5 Stand-alone mode .................................................................................................... 22
5.6 Special settings ........................................................................................................ 22
6. Software update ........................................................................................................... 24
7. DMX protocol ................................................................................................................ 25
8. Technical specications .............................................................................................. 26
9. Disposing of the product ............................................................................................. 30
10. ChangeLog ................................................................................................................. 30
3
1. Safety information
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE POWERING OR INSTALLING YOUR E-BOX!
Save it for future reference.
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
Make sure that the available voltage is not higher than stated on the xture.
Always disconnect the xture from AC power before removing its cover.
Make sure that the supply cables are not damaged by sharp edges. Check the xture and the cables from
time to time.
Do not install the xture near an open ame.
This xture falls under protection class I. Therefore, this xture has to be connected to a mains socket outlet
with a protective earthing connection.
Do not connect this xture to a dimmer pack.
Do not cover the xture with cloth or other materials.
The xture was designed for outdoor use and it is intended for professional application only. It is not for house-
hold use.
When choosing the installation spot, please make sure that the xture is not exposed to extreme heat or dust.
Only operate the xture after having checked that the housing is rmly closed and all screws are tightly fastened.
Operate the xture only after having familiarized yoursef with its functions. Do not permit operation by persons
not qualied to operate the xture. Most damages are the result of unprofessional operation!
Please consider that unauthorized modications on the xture are forbidden due to safety reasons!
Please use the original packaging if the xture is to be transported.
If this device will be operated in any way dierent to the one described in this manual, the product may suer
damages and the warranty becomes void. Furthermore, any other operation may lead to dangers like
short-circuit, burns, electric shock etc.
4
2. Fixture description
2.1 E-box Daisy
A - Top cover
B - Top cover screws
C - Mounting holes
D - Antenna cover
E - Display
F - Control buttons
G - Screws of terminal blocks cover
H - Terminal blocks cover
1 - Power IN (cable gland M20x1.5)
2 - DMX OUT(cable gland M12x1.5)
3 - DMX IN (cable gland M12x1.5)
4 - Ethernet OUT (cable gland M12x1.5)
5 - Ethernet IN (cable gland M12x1.5)
6 - LED Output (cable gland M20x1.5)
View without top cover
5
E-Box Daisy - connection points
L N
Power IN
L N
LED Output
Fuse T 0.5A H
D+ D- 0V
DMX OUT
DMX IN
D+ D- 0V NC NC RD- NC NC RD+ TD- TD+
Ethernet OUT Ethernet IN
NC NC RD- NC NC RD+ TD- TD+
0V D- D+
Data OUT
6
2.2 E-box Star
A - Top cover
B - Top cover screws
C - Mounting holes
D - Antenna cover
E - Display
F - Control buttons
G - Screws of terminal blocks cover
H - Terminal blocks cover
1 - Power IN (ller plug M25 x 1.5/ cable gland M20x1.5)
2 - DMX OUT (cable gland M12x1.5)
3 - DMX IN (cable gland M12x1.5)
4 - Ethernet OUT (cable gland M12x1.5)
5 - Ethernet IN (cable gland M12x1.5)
6 - LED Otputs (ller plug M25 x 1.5/ cable gland
M20x1.5)
View without top cover
7
E-Box Star - connection points
Power IN
LED OUTPUT
D+ D- 0V
D+ D- 0V
0V D- D+
0V D- D+
0V D- D+ 0V D- D+
0V D- D+
0V D- D+
Data OUT
NC NC RD- NC NC RD+ TD- TD+
NC NC RD- NC NC RD+ TD- TD+
Fuse T 0.5A H
DMX OUT DMX IN Ethernet INEthernet OUT
L N
L N
L N
L N
L N
L N
L N
Data OUT
Data OUT
Data OUT
Data OUT
Data OUT
LED OUTPUT
LED OUTPUT LED OUTPUT
LED OUTPUT
LED OUTPUT
8
2.3 E-box Pro
A - Top cover
B - Top cover screws
C - Mounting holes
D - Antenna cover
E - Display
F - Control buttons
G - Screws of terminal blocks cover
H - Terminal blocks cover
1 - Power IN (ller plug M25 x 1.5/ cable gland M20x1.5)
2 - DMX OUT (cable gland M12x1.5)
3 - DMX IN (cable gland M12x1.5)
4 - Ethernet OUT (cable gland M12x1.5)
5 - Ethernet IN (cable gland M12x1.5)
6 - LED Ouputs (ller plug M25 x 1.5/ cable gland
M20x1.5)
View without top cover
9
E-Box Pro - connection points
L N
L N
L N L N L N
L N
L N
L N L N
L N L N
L N
Power IN Power IN
Power IN
Power IN
Power IN Power IN
LED OUTPUT
0V D- D+
0V D- D+
0V D- D+ 0V D- D+
0V D- D+ 0V D- D+
Data OUT
Fuse T 0.5A H
Ethernet INEthernet OUT
NC NC RD- NC NC RD+ TD- TD+ NC NC RD- NC NC RD+ TD- TD+
DMX OUTDMX IN
D+ D- 0V D+ D- 0V
LED OUTPUT
LED OUTPUT
LED OUTPUT LED OUTPUT
LED OUTPUT
Data OUT
Data OUT Data OUT
Data OUT
Data OUT
10
2.4 E-box Lite
A - Top cover
B - Top cover screws
C - Mounting holes
D - Antenna cover
E - Display
F - Control buttons
G - Screws of terminal blocks cover
H - Terminal blocks cover
1 - Power IN (cable gland M20x1.5)
2 - DMX OUT (cable gland M12x1.5)
3 - DMX IN (cable gland M12x1.5)
6 - LED Output (cable gland M20x1.5)
View without top cover
11
E-Box Lite - connection points
Power IN
LED OUTPUT
D+ D- 0V
DMX OUT DMX IN
D+ D- 0V
0V D- D+
Data OUT
12
3. Mounting
Fixture must be installed by a qualied electrician in accordance with all national
and local electrical and construction codes and regulations.
Setting and addressing the E-box without top cover can be done by a qualied
person only!
Note for cable glands.
We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland
before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread
of the gland body.
1. Remove the top cover (A) from the E-box by unscrewing four fastening screws (B) in order to
get access to the display (E), control buttons (F).
2. Fasten the E-box on a non-ammable at surface via four mounting holes (C) of
a diameter of 6 mm in its housing.
3. Remove the terminal blocks cover (H) from the E-box by unscrewing fastening screws (G) in order to
get access to the terminal blocks.
4. Unscrew needed ller plugs M25 x 1.5 (which are installed instead of cable glands M20x1.5) from
the housing of the E-box (for E-box Star and E-box Pro only) and install cable glands M20x1.5.
We recommend you to unscrew always one ller plug (side as rst), install the cable gland with a cable,
connect the cable to the terminal blocks and tighten the cable in the cable gland, than unscrew
the neighbouring ller plug and proceed with installation of cable gland. Repeat this process for all
needed cable glands.
5. Pass cables for DMX and Ethernet through cable glands M12x1.5 and connect them to the terminal blocks
and tighten the cables in the cable glands.
Note: Remove end caps from cable glands before passing cables To keep declared IP rating of the device,
every cable gland has to be covered with the end cap if the cable gland is not used.
Cable glands serve for cables of the following diameters:
Cable gland M12x1.5 (DMX IN/OUT, Ethernet IN/OUT) - for cable of a diameter of 3-7mm.
Cable gland M20x1.5 (Power IN/ Eminere OUT) - for cable of a diameter of 7-13mm.
6. Check that all screws and cable glands are rmly tightened.
7. Screw the terminal blocks cover (H) back to the E-box.
8. Connect the E-box to mains.
9. Set the E-box by means of the control panel (E) and buttons (F).
10. Disconnect the E-box from mains and screw the cover (A) back on the box.
ALWAYS DISCONNECT THE E-BOX (and BOOSTER BOX) FROM MAINS BEFORE
CONNECTING/DISCONNECTING EMINERE MODULES
This device falls under protection class I. Therefore every E-box
has to be connected to a mains socket outlet with a protective earthing connection
13
Power connection
L N PE
Core (EU) Braun Blue Green/yellow
Core (US) Black White Green
DMX connection
D+ D- 0V
Data + Data - Data ground (shielding)
Ethernet connection
Pin 1 2 3 4 5 6 7 8
Function TD+ TD- RD+ NC NC RD- NC NC
Eminere connection
Cable CE Leader:
Wire Power Connection Wire Data Connection
Brown L Orange Data -
Blue N Purple Data +
Yellow/Green
(earth)
Shielding Data ground (0V)
Cable US Leader:
Wire Power Connection Wire Data Connection
Black L Orange Data -
White N Red Data +
Green
(earth)
Shielding Data ground (0V)
Note for Emineres only! The wiring stated above applies to the Emineres marked X on their labels only. Older
versions of Emineres have swapped wires Data - and Data+ ( Orange wire= Data +, Red/Purple wire= Data -)
and do not have mark X on their labels.
Example:
This note does not apply for Emineres Side and Emineres Inground
Example of connection
Number of connected Emineres to one LED output of the E-box depends on a cable length, power voltage,
type of Eminere and type of E-box and operation mode.
14
The tables below state max. theoretical number of Emineres connected to the one LED output of the E-box
without using Booster boxes. Number of Emineres depends on voltage and cable length.
The following tables apply for the Standard mode of E-boxes.
EMINERE 1(Eminere Side 1) Voltage
Cable length * 120V 190V 230V 277V
10 m 83 131 159 191
20 m 83 131 159 191
30 m 58 131 159 191
50 m 35 88 128 186
70 m 25 63 92 133
100 m 17 44 64 93
200 m 9 22 32 47
EMINERE 2(Eminere Side 2) Voltage
Cable length * 120V 190V 230V 277V
10 m 41 64 78 94
20 m 41 64 78 94
30 m 28 64 78 94
50 m 17 43 63 91
70 m 12 31 45 65
100 m 9 21 31 46
200 m 4 11 16 23
EMINERE 3(Eminere Side 3) Voltage
Cable length * 120V 190V 230V 277V
10 m 28 44 53 64
20 m 28 44 53 64
30 m 19 44 53 64
50 m 12 29 43 62
70 m 8 21 31 44
100 m 6 15 21 31
200 m 3 7 11 16
EMINERE 4 (Eminere Side 4) Voltage
Cable length * 120V 190V 230V 277V
10 m 21 33 40 48
20 m 21 33 40 48
30 m 15 33 40 48
50 m 9 22 32 47
70 m 6 16 23 38
100 m 4 11 16 23
200 m 2 5 8 12
* Cable length is a total cable length between E-box and last connected Eminere.
Example: Total cable length=L1+L2+L3
Important note for E-box Star
The tables for Standard and Pass-Thr mode mode state max. total number of Emineres connected to 6 LED
outputs of the E-box Star (or max. number of Emineres connected to one LED output if the rest of LED outputs
are not connected).The E-box Star has only one power input!
Example 1:
E-box Star, voltage=230V, cable length=100m,xture= Eminere 4, total. number of Emineres 4 =16 pcs, without Booster box,
Standard mode.
LED Output 1 =4 x Eminere 4 LED Output 2 =4 x Eminere 4 LED Output 3 =4 x Eminere 4
LED Output 4 =4 x Eminere 4 LED Output 5 =not connected LED Output 6 =not connected
LED Outputs 5 and 6 are free, otherwise max. number of 16 pieces of Eminere 4 will be exceeded.
15
Example 2:
E-box Star, voltage=230V, cable length=100m,xture= Eminere 4, total number of Emineres 4 =16 pcs, without Booster box,
Standard mode.
LED Output 1 =16 x Eminere 4 LED Output 2 = not connected LED Output 3 = not connected
LED Output 4 = not connected LED Output 5 =not connected LED Output 6 =not connected
Outputs 2,3,4,5,6 to Eminere are free because the max. number of 16 pieces of the Eminere 4 is connected to the output 1.
The following tables apply for the Pass-Thr mode of E-boxes
EMINERE 1(Eminere Side 1) Voltage
Cable length * 120V 190V 230V 277V
10 m 32 32 32 32
20 m 32 32 32 32
30 m 32 32 32 32
50 m 32 32 32 32
70 m 25 32 32 32
100 m 17 32 32 32
EMINERE 2(Eminere Side 2,
Eminere Inground 2)
Voltage
Cable length * 120V 190V 230V 277V
10 m 32 32 32 32
20 m 32 32 32 32
30 m 28 32 32 32
50 m 17 32 32 32
70 m 12 31 32 32
100 m 9 21 32 32
EMINERE 3(Eminere Side 3) Voltage
Cable length * 120V 190V 230V 277V
10 m 28 32 32 32
20 m 28 32 32 32
30 m 19 32 32 32
50 m 12 29 32 32
70 m 8 21 31 32
100 m 6 15 21 31
EMINERE 4(Eminere Side 4,
Eminere Inground 4)
Voltage
Cable length * 120V 190V 230V 277V
10 m 21 32 32 32
20 m 21 32 32 32
30 m 15 32 32 32
50 m 9 22 32 32
70 m 6 16 23 32
100 m 4 11 16 23
* Cable length is a total cable length between E-box and last connected Eminere.
Example for Eminere Inground: Total cable length= L1+∑L2+∑L3.
16
The Booster box
To compensate a voltage drop in a large installation, the Booster boxes have to be connected in the chain of
Eminere modules.
Example: E-box Daisy, Power supply= 230V, Total cable length=70m, Standard mode, type of Eminere: Eminere 2
The Booster box has to be connected after every 45th Eminere 2 (xture 45 and xture 90 from 94 xtures).
The following tables give numbers of Emineres after which the Booster box has to be installed in the chain of
Emineres.
Tables for Standard mode
Eminere 1
Eminere Side 1
Max. possible number of Emineres 1= 191
Voltage
Cable length 120V 190V 230V 277V
10 m 83,166 131 159 -
20 m 83,166 131 159 -
30 m 58,116,174 131 159 -
50 m 35,70,105,140,175 88,176 128 186
70 m 25,50,75,100,125,150,175 63,126,189 92,184 133
100 m 17,34,51,68,85,102,119,136,
153,170,187
44,88,132,176 64,128 93,186
200 m 9,18,27,36,45,54,60,72,81
90,99,108,117,126,135,144,153,
162,171,180,189,
22,44,66,88,110,
132,154,176
32,64,96,128,160 47,94,
141,188
EMINERE 2
Eminere Side 2
Max. possible number of Emineres 2= 94
Voltage
Cable length 120V 190V 230V 277V
10 m 41,82 64 78 -
20 m 41,82 64 78 -
30 m 28,56,84 64 78 -
50 m 17,34,51,68,85 43,86 63 91
70 m 12,24,36,48,60,72,84 31,62,93 45,90 65
100 m 9,18,27,36,45,54,60,72,81,90 21,42,63,84 31,62,93 46,92
17
200 m 4,8,12,16,20,24,28,32,36,40,
44,48,52,56,60,64,68,72,76,80
,84,88,92
11,22,33,44,55,66,
77,88
16,32,48,64,80 23,46,69,92
Eminere 3
Eminere Side 3
Max. possible number of Emineres 3= 64
Voltage
Cable length 120V 190V 230V 277V
10 m 28,56 44 53 -
20 m 28,56 44 53 -
30 m 19,38,57 44 53 -
50 m 12,24,36,48,60 29,58 43 62
70 m 8,16,24,32,40,48,56 21,42,63 31.62 44
100 m 6,12,18,24,30,36,42,48,54,60 15,30,45,60 21,42,63 31,62
200 m 3,6,9,12,15,18,21,24,27,30,
33,36,39,42,45,48,51,54,57,
60,63
7,14,21,28,35,42,49
56,63
11,22,33,44,55 16,32,48,
Eminere 4
Eminere Side 4
Max. possible number of Emineres 4= 48
Voltage
Cable length 120V 190V 230V 277V
10 m 21,42 33 40 -
20 m 21,42 33 40 -
30 m 15,30,45 33 40 -
50 m 9,18,27,36,45 22,44 32 47
70 m 6,12,18,24,30,36,42 16,32 23,46 38
100 m 4,8,12,16,20,24,28,32,36,40,44 11,22,33,44 16,32 23,46
200 m 2,4,6,8,10,12,14,16,18,20,22,24,
26,28,30,32,34,36,38,40,
42,44,46
5,10,15,20,25,30,
35,40,45
8,16,24,32,40 12,24,36
Please see the Eminere user manual for more information about the Booster box installation.
Tables for Pass-Thru mode
EMINERE 1
Eminere Side 1
Max. possible number of Emineres 1= 32
Voltage
Cable length 120V 190V 230V 277V
10 m - - - -
20 m - - - -
30 m - - - -
50 m - - - -
70 m 25 - - -
100 m 17 - - -
EMINERE 2
Eminere Side 2
Eminere
Inground 2
Max. possible number of Emineres 2= 32
Voltage
Cable length 120V 190V 230V 277V
10 m - - - -
20 m - - - -
30 m 28 - - -
50 m 17 - - -
70 m 12,24, 31 - -
100 m 9,18 21 31
18
EMINERE 3
Eminere Side 3
Max. possible number of Emineres 3= 32
Voltage
Cable length 120V 190V 230V 277V
10 m 28 - - -
20 m 28 - - -
30 m 19 - - -
50 m 12,24 29 - -
70 m 8,16,24 21 31. -
100 m 6,12,18,24,30 15,30 21 31
EMINERE 4
Eminere Side 4
Eminere
Inground 4
Max. possible number of Emineres 4= 32
Voltage
Cable length 120V 190V 230V 277V
10 m 21 - - -
20 m 21 - - -
30 m 15,30 - - -
50 m 9,18,27 22 - -
70 m 6,12,18,24,30 16 23 -
100 m 4,8,12,16,20,24,28 11,22 16 23
4. E-box modes
The E-box menu allows you to switch connected LED modules to the two modes:
Standard - LED modules are switched to an internal serial connection. DMX addressing of connected LED
modules is made automatically(default values are: DMX address=1, DMX Preset = 1 IPix Mode), changes can be
done by the E-box menu (item Set DMX Address and item DMX Preset). The Standard mode is set as default.
The Emineres and Emineres Side can be switched to the Standard or to the Pass-Thr mode
Pass-Thr - LED modules are switched to an internal parallel connection. This mode is primarily intended for
Emineres Inground. DMX addressing of connected LED modules has to be done manually by means of the
Robe Universal Interface (or its wireless version Robe Universal Interface WTX) and a software RDM Manager.
The Emineres Inground can be switched to the Pass -Thr mode only.
Example of the Emineres Inground connection for their addressing.
Note: RDM manager and DMX controller cannot run in the same time.
19
Examples of RDM manager screenshots for one connected LED module.
Initial screen of the RDM manager:
Options in the Control panel allows you to set DMX address and Personality for each LED module.
Occupied channels are displayed in the window DMX patch on the right side of the Control panel.
Click on the device to show
options of the Control panel
Click on the green
arrow to save
adjusted values
DMX preset and
number of used
channels.
DMX address
20
Possible numbers of connected LED modules for each E-box mode is stated in the chapter "3. Mounting".
5. E-box menu
The E-box is equipped with 2-row LCD display and four buttons which allows to address the xture and set the
xture´s behaviour according to your needs.
The four control buttons have the following functions:
- ESCAPE button- to escape function or menu.
- ENTER button- to select a function or conrm adjusted value.
, - UP and DOWN buttons - to move within the menu.
When you change any setting of the E-box, disconnect the E-box from power and
connect it to power again to activate changes which you have made.
The connected LED modules can be operated in two modes (menu Special-->E-box mode):
Standard - intended for Emineres and Emineres Side
Pass- Thr - intended for Emineres Inground, Emineres and Emineres Side.
Emineres Inground can be operated in the Pass-Thr mode only!
Some menu items are not accessible if the option Pass-Thr is selected from the menu E-box mode
(menu Pesonality).
These menu items are marked by # in the article below.
5.1 DMX Addr
# Set DMX Address - use this menu item to set the DMX start address of the xture, which is dened as the
rst channel from which the E-box will respond to a DMX controller.
Note: if the option Pass-Thr is selected from the menu E-box mode, the sign "Pass-Thr" is displayed instead
of the sign "DMX Addr" and the menu item Set DMX Address is not available.
IP address* - select this menu item to set desired IP address. IP address is the Internet protocol
address.The IP uniquely identies any node (xture) on a network. There cannot be 2 xtures with
the same IP address on the network!
Default Address. This address is derived from xture´s MAC address and
cannot be changed. Conrm the item "Set Address" to select this address.
Custom Address. IP address consists of four decimal numbers, each ranging
from 0 to 255, separated by dots, e.g., 172.16.254.1. Each part represents a group of 8 bits
(octet) of the address.
The following items "IP Adr 1", " IP Adr 2", " IP Adr 3", " IP Adr 4" allow you to set each
part (number) of the address. After setting desired IP address, conrm the item
"Set Address" to save this address.
Network mask* - select this menu item to set desired network mask. A network mask is a 32-bit mask used to
divide an IP address into subnets and specify the networks available hosts.
The following items "Net M.1", "Net.M.2", " Net.M.3", " Net.M.4" serve for setting of each part (number) of
the net mask.
After setting desired network mask, conrm the item "Set Net M." to save adjusted values.
* E-box Daisy, E-box Star and E-box Pro only.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

Anolis e-box series User manual

Category
Stroboscopes & disco lights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI