Optimus MIVASET User manual

Type
User manual

Optimus MIVASET is a toilet alarm for disabled toilets. The system is suitable for various applications where it makes sense to provide signalling for potentially dangerous situations. The alarm tone is local on the room Lamp and can be send to a central staff display as well. A maximum of 8 MIVA sets can be monitored on the central staff display. There is no need for a configuration via PC. The complete set is delivered in a single box and contains all components (except wiring) that are necessary for the installation of a single toilet space.

Optimus MIVASET is a toilet alarm for disabled toilets. The system is suitable for various applications where it makes sense to provide signalling for potentially dangerous situations. The alarm tone is local on the room Lamp and can be send to a central staff display as well. A maximum of 8 MIVA sets can be monitored on the central staff display. There is no need for a configuration via PC. The complete set is delivered in a single box and contains all components (except wiring) that are necessary for the installation of a single toilet space.

Manual iCall MIVA SET V1.0 27/01/2016
Manual iCall MIVA SET V1.0
Manuel du système iCall MIVA SET V1.0
Handbuch iCall MIVA SET V1.0
Handleiding iCall MIVA SET V1.0
Manual iCall MIVA SET V1.0 1
Table of contents
English manual ................................................................... 2
Manuel du système française ............................................... 14
Deutsch Handbuch .............................................................. 26
Nederlandstalig handboek .................................................... 38
Manual iCall MIVA SET V1.0 2
Manual iCall MIVA set V1.0
Copyright
This document may not be copied in whole or in part or otherwise
reproduced without prior written consent from IndigoCare Europe or
IndigoCare USA, except where specifically permitted under
international copyright law.
Disclaimer
The information in this document is subject to change without notice.
IndigoCare Europe or IndigoCare USA assumes no responsibility for
inaccuracies or omissions and specifically disclaims any liabilities,
losses, or risks, personal or otherwise, incurred as a consequence,
directly or indirectly, of the use or application of any of the contents of
this document. For the latest documentation, contact IndigoCare
Europe or Indigocare USA.
The users, by their use of this product, agree to indemnify the
manufacturer and/or seller of this product against all claims, litigation,
and suits filed for patient information violations.
Intended use
Use this product only for the purpose it was designed for; refer to the
data sheet and user documentation for details. For the latest product
information, contact Indigocare Europe or IndigoCare USA.
You are cautioned that any changes or modifications not expressly
approved by the party responsible for compliance could void the user's
authority to operate the equipment.
Manual iCall MIVA SET V1.0 3
Contact information:
For US-Region: For EMEA-Region:
IndigoCare USA IndigoCare Europe
1001 South Dairy Ashford, Suite 100 Schoebroekstraat 48
Houston, TX 77077 3583 Paal
USA Belgium
T: +1 713.595.6698 T:+32 (0) 11 247 090
F: +1 713.595.6699 F: +32 (0) 11 247 099
@: usa@indigocare.com @:europe@indigocare.com
www.indigocare.com www.indigocare.com
Manual iCall MIVA SET V1.0 4
Contents
1. Introduction ............................................. 5
2. Features .................................................. 5
3. Functionality ............................................. 5
4. Components ............................................. 6
5. Installation ............................................... 7
6. Part Numbers ......................................... 12
7. Pull String installation .............................. 13
Manual iCall MIVA SET V1.0 5
1. Introduction
The MIVA call system is designed for use in disabled toilets. The system
is suitable for various applications where it makes sense to provide
signalling for potentially dangerous situations. The alarm tone is local
on the room Lamp and can be send to a central staff display as well. A
maximum of 8 MIVA sets can be monitored on the central staff display.
There is no need for a configuration via PC.
The complete set is delivered in a single box and contains all
components (except wiring) that are necessary for the installation of a
single toilet space.
2. Features
Simple and quick installation
Hygienic & aesthetic
Standalone set
Manufactured entirely from rustproof materials
3. Functionality
LED room Lamp can be connected to multiple call points and
operates as central control module
Multiple Miva sets can be connected to a single central staff
display
Visual and acoustic alarm signal
Pull String and Call/Cancel unit available as “normally open” or
“normally closed” type
According NEN 1814 standard, Pull String must be installed
such that its lower end is between 300 and 450 mm above
floor level.
Set Complies with the NEN 1814 standard
Reassurance LED
Manual iCall MIVA SET V1.0 6
4. Components
Room Lamp
The room lamp is installed outside
the toilet room. Upon activation of
a call, a red LED will indicate that
the person in the toilet room
needs help.
Mode 1: LED flashes at a rhythm
of 1 sec ON and 1 sec OFF, in
addition an acoustic sound is sent
every 1 sec to get attention on
the call.
Mode 2: LED is stable ON, in
addition an acoustic sound is send
every 17 sec to get attention on
the call.
Pull String switch
By activating the pull string an
alarm is generated, a
confirmation LED at the pull string
wall box is the confirmation of the
call.
This confirmation Lamp will flash
at a cadence of 1 second in Mode
1 and will Lamp steady in Mode 2.
Install the pull string between 300
and 450mm above the floor and
alongside the toilet walls.
(regulation NEN1814)
Manual iCall MIVA SET V1.0 7
Call and Cancel button
The call and cancel button must
be located in the room. The red
button is an extra call button and
has a confirmation LED. By
pressing the green button the call
from the room is cancelled.
Power supply
The power supply is a 24V DC
900mA adaptor.
5. Installation
5.1. Mode Selection
In the front of the room Lamp is a small selection button. By
pressing this button you toggle between Mode 1 and Mode 2.
In case of power failure the selected mode will still be active
on repowering of the unit.
LED
1 Sec ON
1 Sec OFF
Buzzer
1 Sec ON
1 Sec OFF
Output
1 Sec ON
1 Sec OFF
LED
Continued ON
-
Buzzer
1 Sec ON
17 Sec OFF
Output
Continued ON
-
Manual iCall MIVA SET V1.0 8
5.2. Normally open or normally closed connected
The call points can be connected as a normally open or
normally closed input. For field safe reasons we advise to use
the normally closed solution.
In case of using a normally open connection the second input
must be provided with a small wire bridge.
5.3. Wiring installation
Power connection
Buzzer connection
1 2 3 4 5 6
1 2 3 4
R
T
-
+
24V
Call NC
Call NO
Can cel
Call LED
Buzzer
Buzzer
1 2 3 4 5 6
1 2 3 4
R
T
-
+
24V
Call NC
Call NO
Can cel
Call LED
Buzzer
24V
AC
Input
-
+
Room Lamp
Room Lamp
Manual iCall MIVA SET V1.0 9
Pull String connection (normally closed)
Pull Cord connection (normally open)
Call and Cancel button (normally closed)
1 2 3 4 5 6
1 2 3 4
R
T
-
+
24V
Call NC
Call NO
Can cel
Call LED
Buzzer
24V
AC
Input
-
+
LED Present
Present
Call NO
Call NC
LED Call
+24V
Room Lamp
Room Lamp
Room Lamp
Pull String switch
Pull String switch
Call/Cancel button
Manual iCall MIVA SET V1.0 10
Call and Cancel button (normally open)
1 2 3 4 5 6
1 2 3 4
R
T
-
+
24V
Call NC
Call NO
Can cel
Call LED
Buzzer
24V
AC
Input
-
+
LED Present
Present
Call NO
Call NC
LED Call
+24V
Room Lamp
Call/Cancel button
Manual iCall MIVA SET V1.0 11
Complete diagram for normally open connection
Complete diagram for normally closed connection
Room Lamp
Room Lamp
Pull String switch
Pull String switch
Call/Cancel button
Call/Cancel button
Manual iCall MIVA SET V1.0 12
6. Part Numbers
NWBAES5000
Complete MIVA set
NWBAES4500
Pull String button
NWBAES4101
Call and Cancel button
PWBXGA0104
Pull String
NWAABI0100
Power supply
NWAABI0200
AC-Cord
NWBAES3852
Room Lamp
Manual iCall MIVA SET V1.0 13
7. Pull String installation
Manuel du système iCall MIVA SET V1.0 15
Données de contact :
États-Unis : EMEA :
IndigoCare USA IndigoCare Europe
1001 South Dairy Ashford, Suite 100 Schoebroekstraat 48
Houston, TX 77077 3583 Paal
États-Unis Belgique
T: +1 713.595.6698 T:+32 (0) 11 247 090
F: +1 713.595.6699 F: +32 (0) 11 247 099
@: usa@indigocare.com @:europe@indigocare.com
www.indigocare.com www.indigocare.com
Manuel du système iCall MIVA SET V1.0 16
Table des matières :
1. Introduction ......................................... 17
2. Caractéristiques .................................... 19
3. Fonctions ............................................. 17
4. Composants ......................................... 18
5. Installation ........................................... 19
6. Codes des pièces ................................... 24
7. Montage du cordon d'appel ..................... 25
Manuel du système iCall MIVA SET V1.0 21
Branchement du cordon d'appel (normalement fermé)
Branchement du cordon d'appel (normalement ouvert)
Bouton d'appel et d'annulation (normalement fermé)
1 2 3 4 5 6
1 2 3 4
R
T
-
+
24V
Call NC
Call NO
Can cel
Call LED
Buzzer
24V
AC
Input
-
+
LED Present
Present
Call NO
Call NC
LED Call
+24V
Voyant
local
Voyant
local
Voyant
local
Com. à cordon
Com. à cordon
Bouton appel/annul.
Manuel du système iCall MIVA SET V1.0 22
Bouton d'appel et d'annulation (normalement ouvert)
1 2 3 4 5 6
1 2 3 4
R
T
-
+
24V
Call NC
Call NO
Can cel
Call LED
Buzzer
24V
AC
Input
-
+
LED Present
Present
Call NO
Call NC
LED Call
+24V
Voyant
local
Bouton appel/annul.
Manuel du système iCall MIVA SET V1.0 24
6. Codes des pièces
NWBAES5000
Dispositif MIVA complet
NWBAES4500
Bouton pour cordon d'appel
NWBAES4101
Bouton d'appel et d'annulation
PWBXGA0104
Cordon d'appel
NWAABI0100
Alimentation électrique
NWAABI0200
Cordon d'alimentation CA
NWBAES3852
Voyant local
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51

Optimus MIVASET User manual

Type
User manual

Optimus MIVASET is a toilet alarm for disabled toilets. The system is suitable for various applications where it makes sense to provide signalling for potentially dangerous situations. The alarm tone is local on the room Lamp and can be send to a central staff display as well. A maximum of 8 MIVA sets can be monitored on the central staff display. There is no need for a configuration via PC. The complete set is delivered in a single box and contains all components (except wiring) that are necessary for the installation of a single toilet space.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI