Installation Procedure for Retro Field Kit P/N 0558002256 F-15-645
7
CAUTION
!
15. Reconnect electricity to Precision Plasma Power
Source.
16. Turn power on.
17. Adjust coolant pump valve clock-wise to
increase coolant pressure to 115 PSI.
18. Check for leaks at hose connections.
19. Turn power off to Precision Plasma Power
Source.
20. Replace nut on coolant pump.
Note: Check the pump screen filter
located under the large nut and clean if
required.
21. Replace right side panel of Power Source
22. Check coolant level and add if necessary.
Commercial Antifreeze/Coolant Will Cause
Torch To Malfunction
Use Special Torch Coolant! P/N 156N05
Due to high electrical conductivity, DO NOT
use tap water or commercial antifreeze for
torch cooling. A specially formulated torch
coolant is REQUIRED. This coolant also
protects for freezing to -34° C.
Operating unit without coolant will cause
permanent damage to the coolant pump.
23. Resume normal operations
Set to 115 PSI
Location of
pump filter