5
InstallationInstructions
WARNINGElectric Shock Hazard
•Thisappliancemustbeproperlygrounded.
•Donotuseanextensioncord.
•Beforeinstallingrange,switchpoweroffattheservicepanelandlocktheservicedisconnectingmeans
topreventpowerfrombeingswitchedonaccidentally.Whenthedisconnectionmeanscannotbelocked,
securelyfastenaprominentwarningdevice,suchasatag,totheservicepanel.
Failuretofollowtheseinstructionsmayresultinseriousinjuryordeath.
WARNINGFire Hazard
Improperconnectionofaluminumhousewiringtocopperleadscanresultinanelectricalorfirehazard.If
residenceleadsarealuminum,useonlyconnectorsdesignedforjoiningcoppertoaluminumandfollowthe
manufacturer’srecommendedprocedureclosely.Failuretodosomayresultinseriousinjuryordeath.
5A
ELECTRICAL REQUIREMENTS
Werecommendyouhavetheelectricalwiringandhookupoftheapplianceconnectedbyaqualified
electrician.Afterinstallation,havetheelectricianshowyouhowtodisconnectpowerfromtheappliance.
Youmustuseasingle-phase,120/208VACor120/240VAC,60Hertzelectricalsystem.
EffectiveJanuary1,1996,theNationalElectricalCoderequiresthatnewconstruction(notexisting)utilizea
four-conductorconnectiontoanelectricoven.Wheninstallinganelectricoveninnewconstruction,amobile
home,recreationalvehicleorareawherelocalcodesprohibitgroundingthroughtheneutralconductor,refer
tothesectiononfour-conductorbranchcircuitconnections.
Checkwithyourlocalutilitiesforelectricalcodeswhichapplyinyourarea.Failuretowireyourovenaccording
togoverningcodecouldresultinahazardouscondition.Iftherearenolocalcodes,yourovenmustbewired
andfusedtomeettheNationalElectricalCode,NFPANo.70-latestedition,availablefromtheNationalFire
ProtectionAssociation.
Ratingplateislocatedonovenfrontframeandisvisiblewhenovendoorisopen.
Thisappliancemustsuppliedbewiththepropervoltageandfrequency,andconnectedtoanindividual,
properlygrounded,40amp(minimum)branchcircuitprotectedbyacircuitbreakerortime-delayfuse.
DO
NOTshortentheflexibleconduit.Theconduitstrainreliefclampmustbesecurelyattachedtothejunction
boxandtheflexibleconduitmustsecurelyattachedtotheclamp.Iftheflexibleconduitwillnotfitwithinthe
clamp,donotinstalltheovenuntilaclampofthepropersizeisobtained.
The3powerleadssuppliedwiththisappliancearesuitableforconnectiontoheaviergaugehousehold
wiring.Theinsulationofthese3leadsisratedfortemperaturesmuchhigherthanthetemperatureratingof
thehouseholdwiring.Thecurrent-carryingcapacityoftheconductorisgovernedbythewiregaugeandthe
temperatureratingoftheinsulationaroundthewire.