2955-04

Simer Pumps 2955-04, 2905-04, 2957, 2957-04 User manual

  • Hello! I am an AI chatbot trained to assist you with the Simer Pumps 2955-04 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation/Operation/Parts
For further operating, installation,
or maintenance assistance:
Call 1-800-468-7867 /
1-800-546-7867
English . . . . . . . . . . . . . . . Pages 2-6
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le
1 (800) 468-7867 /
1 (800) 546-7867
Français . . . . . . . . . . . . Pages 7-11
Instalación/Operación/Piezas
Para mayor información sobre el
funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-468-7867 /
1-800-546-7867
Español . . . . . . . . . . .Paginas 12-16
©2009 SIM860 (Rev. 6/9/09)
OWNER’S MANUAL
Submersible Sump Pump
NOTICE D’UTILISATION
Pompe de puisard submersible
MANUAL DEL USUARIO
Bomba sumergible
de sumidero
MOD. 2905-04, 2955-04, 2957-04
293 Wright St., Delavan,WI 53115
Phone:
1-800-468-7867
1-800-546-7867
Fax:
1-800-390-5351
Web Site:
http://www.simerpump.com
Safety 2
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
READ AND FOLLOW
SAFETY INSTRUCTIONS!
Carefully read and follow all safety instructions in this manual
and on pump.
This is the safety alert symbol. When you see this symbol
on your pump or in this manual, look for one of the fol-
lowing signal words and be alert to the potential for personal
injury.
warns about hazards that will cause serious per-
sonal injury, death or major property damage if ignored.
warns about hazards that can cause serious per-
sonal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored.
The word NOTICE indicates special instructions which are
important but not related to hazards.
Electrically powered sump pumps normally give many years of
trouble-free service when correctly installed, maintained, and
used. However, unusual circumstances (interruption of power to
the pump, dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in the pump,
etc.) may prevent your pump from functioning normally. To pre-
vent possible water damage due to flooding, consult your dealer
about installing a secondary sump pump, a DC backup sump
pump, and/or a high water alarm. See the “Troubleshooting
Chart” in this manual for information about common sump
pump problems and remedies. For more information, see your
dealer or call customer service at 1-800-468-7867.
1. Know the pump application, limitations, and potential
hazards. Pump water only with this pump.
2. Do not use this pump in water with fish present. If any oil
leaks out of the motor it can kill fish.
3. Disconnect the power before servicing.
4. Release all pressure within the system before servicing any
component.
5. Drain all the water from the system before servicing.
6. Secure the discharge line before starting the pump. An unse-
cured discharge line will whip, possibly causing personal
injury and/or property damage.
7. Check hoses for weak or worn condition before each use,
making certain that all connections are secure.
8. Periodically inspect the sump, pump and system compo-
nents. Keep free of debris and foreign objects. Perform rou-
tine maintenance as required.
9. Provide a means of pressure relief for pumps whose dis-
charge line can be shut-off or obstructed.
10. Personal Safety:
a. Wear safety glasses at all times when working with
pumps.
b. Keep work area clean, uncluttered and properly lighted –
replace all unused tools and equipment.
c. Keep visitors at a safe distance from work area.
d. Make workshop child-proof – with padlocks, master
switches, and by removing starter keys.
11. When wiring an electrically driven pump, follow all electri-
cal and safety codes that apply.
12. This equipment is only for use on 115 volt and is equipped
with an approved 3-conductor cord and 3-prong, grounding-
type plug.
Hazardous voltage. Can shock, burn or
cause death. To reduce the risk of electric shock, pull the
plug before servicing. Pump is supplied with a grounding
conductor and grounding-type attachment plug. Be sure it
is connected only to a properly grounded grounding-type
receptacle.
Where a 2-prong wall receptacle is encountered, it must be
replaced with a properly grounded 3-prong receptacle
installed in accordance with codes and ordinances that apply.
This pump has not been investigated for use in swimming
pool areas.
13. A ground fault circuit interrupter is recommended for use
with any electrical appliance submerged in water. Installation
and all wiring should be performed by a qualified electrician.
14. Make certain the power source conforms to the requirements
of your equipment.
15. Protect the electrical cord from sharp objects, hot surfaces,
oils, and chemicals. Avoid kinking the cord. Replace or repair
damaged or worn cords immediately.
16. Do not touch an operating motor. Motors can operate at high
temperatures.
17. Do not handle the pump or pump motor with wet hands or
when standing on a wet or damp surface, or in water.
Risk of electric shock. Can burn or kill. If your
basement has water or moisture on floor, do not walk on the wet
area until all power has been turned off. If the shut-off box is in
the basement, call electric company or hydro authority to shut-
off the service to house, or call your local fire department for
instructions. Failure to follow this warning can result in fatal
electrical shock.
18. DO NOT splice the electrical power cord.
19. DO NOT allow the electrical cord plug to be submerged.
20. DO NOT use extension cords. They are a fire hazard and
can reduce voltage sufficiently to prevent pumping and/or
damage motor.
21. Connect or wire the pump to an individual branch circuit
with no other outlets or equipment in the circuit. Size fuses
or circuit breakers according to the specifications.
DESCRIPTION
This submersible sump pump is designed for use in home sumps.
The unit is equipped with a 3-prong grounding-type power cord.
The shaded-pole motor is oil filled and sealed for cooler running.
The sleeve bearings on the motor shaft never needs lubrication.
The pump includes automatic reset thermal protection.
SPECIFICATIONS
Power supply required.............................................115V, 60 HZ
Liquid Temp. Range................................32° F-120° F (0°-49° C)
Individual Branch Circuit Required ...............................15 Amps
Discharge Adapter...................................................1-1/4" MNPT
Pump water only with this pump.
NOTICE: This unit is not designed as a waterfall or fountain pump,
or for applications involving salt water or brine! Use with waterfalls,
fountains, salt water or brine will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
General Information / Installation / Operation 3
PERFORMANCE
INSTALLATION
1. Install tethered switch models in a sump pit with a mini-
mum diameter of 14" (356mm). Install vertical switch mod-
els in a sump pit with a minimum diameter of 11" (280mm).
Construct the sump pit of tile, concrete, steel or plastic.
Check the local codes for approved materials.
The pump should not be installed on clay, earth or sand sur-
faces. Clean the sump pit of small stones and gravel which
could clog the pump. Keep the pump suction housing clear
of debris.
2. Install the pump in the pit so the switch operating mecha-
nism has maximum possible clearance.
3. Install an in-line check valve to prevent flow backwards
through the pump when the pump shuts off.
4. Install the discharge plumbing.
A. When using rigid pipe, use plastic pipe. Wrap the dis-
charge pipe thread with Teflon
TM
tape. Screw the pipe
into the pump discharge port hand tight +1 – 1-1/2 turns.
NOTICE: Do not use ordinary pipe joint compound on
plastic pipe. Pipe joint compound can attack plastics.
NOTICE: Thread the discharge pipe into the pump body
carefully to avoid stripping or crossing threads.
B. If a flexible discharge hose is used, make sure the pump
is secured in the sump to prevent movement. Do not use
a flexible discharge pipe in any permanent installation.
Risk of flooding. Can cause personal
injury or property damage. Failure to secure pump may
allow pump movement, switch interference and prevent
pump from starting or stopping.
NOTICE: The discharge piping should be as short as pos-
sible to reduce pipe friction losses. Discharge pipe diam-
eter should be equal to or larger than the discharge size
of the pump. Smaller pipe diameters will restrict the
capacity of the pump and reduce pump performance.
C. Secure the discharge line before starting the pump.
To reduce motor noise and vibrations, a short length of
rubber hose (e.g. radiator hose) can be connected into
the discharge line near the pump using suitable clamps.
If the pump discharge line is exposed to outside sub-
freezing atmosphere, the portion of the line exposed
must be installed so any water remaining in the pipe will
drain to the outfall by gravity. Failure to do this can
cause any water trapped in the discharge line to freeze
which could result in damage to pump.
5. Power Supply: This pump is designed for 115 V., 60 Hz.,
operation and requires a minimum 15 amp individual
branch circuit. Both the pump and switch are supplied with
3-wire cord sets with grounding-type plugs. The switch plug
is inserted directly into the outlet and the pump plug inserts
into the opposite end of switch plug.
Hazardous voltage. Can shock, burn or
cause death. Pump is supplied with a grounding conductor
and grounding-type attachment plug. To reduce the risk of
electric shock, be certain that it is connected only to a prop-
erly grounded, grounding type receptacle such as a ground-
ed water pipe or a properly grounded metallic raceway or
ground wire system. Ground terminal on pump cord plug is
provided for your protection. DO NOT REMOVE!
A ground fault circuit interrupter is recommended for use
with any electrical appliance submerged in water. For instal-
lation of such a circuit, consult a licensed electrician.
6. After the piping and the check valve (if needed) have been
installed, the unit is ready for operation
7. Check the operation by filling the sump with water and
observing pump operation through one complete cycle.
Risk of flooding. Can cause personal injury
and/or property damage. Failure to make this operational
check may lead to flooding and premature failure.
OPERATION
Risk of electric shock. Shock can burn or kill.
Do not handle a pump or pump motor with wet hands or
when standing on wet or damp surface, or in water.
1. Keep the pump inlet screen clear.
2. The shaft seal depends on water for lubrication. Do not
operate the pump unless it is submerged in water as the
seal may be damaged if the pump is allowed to run dry.
3. The motor is equipped with an automatic reset thermal
protector. If the temperature in the motor should rise undu-
ly, the switch will cut off all of the power before any dam-
age can be done to the motor. When the motor has cooled
sufficiently, the switch will reset automatically and restart
the motor. If the protector trips repeatedly, the pump
should be removed and checked for the cause of the diffi-
culty. Low voltage, long extension cords, a clogged
impeller, very low head or lift, etc., could cause cycling.
Refer to the Troubleshooting Chart on Page 5 for additional
information.
Individual Switch Setting
Model Max. Branch Circuit Cord in inches (mm)
Number HP Load Amps Required (Amps) Length
On Off
2905-04 1/4 6.0 15 8’ 10” (254) 3” (76)
2955-04 1/3 10.0 15 8’ 11” (279) 4” (102)
2957-04 1/3 10.0 15 8’ 7-1/2” (191) 2-1/2” (64)
MOTOR, SWITCH, & CORD SPECIFICATIONS
GPM (LPM) AT TOTAL FEET (m)
510152025
Model (1.5m) (3m) (4.6m) (6.1m) (7.6m)
CAPACITY GALLONS(L)/HOUR
2905-04
1,170 1,020 810 510 0
(4,429) (3,840) (3,066) (1,931) (0)
2955-04 1,740 1,620 1,260 720 60
2957-04 (6,600) (6,120) (4,740) (2,700) (240)
TM
E.I. DuPont de Nemours and Company Corporation.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Maintenance 4
4. Periodically inspect the pump, system components and
sump for debris and foreign objects. Keep the sump free of
all refuse. Perform routine maintenance as required.
Risk of flooding. Flooding can cause personal
injury or property damage. This pump comes with the auto-
matic float switch mounted on the motor cover ready for oper-
ation. Do not change switch settings. Refer to the “Motor,
Switch & Cord Specifications” chart for switch settings.
MAINTENANCE
To Clean the Pump Screen:
NOTICE: Attempting to disassemble motor will void warranty.
Risk of electrical shock. Shock can burn or kill.
Always unplug the pump from the power source before servic-
ing any system component. Do not lift pump by power cord.
1. Disconnect power before servicing.
Risk of Electric shock. Shock can burn or
cause death. When servicing the system always disconnect
power cord from the electrical outlet.
2. Loosen the discharge pipe.
3. Use the pump handle to lift the pump out of the sump pit
and place the pump on a clean level surface.
4. To clean the screen, use a screwdriver to unsnap the screen
(See Figure 1), remove and rinse off the screen.
5. Re-install the screen. Be sure all the snaps catch.
6. Put the pump back into the sump pit.
7. Re-install the discharge pipe.
8. Check the system operation by filling the basin with water
and observing the pump’s operation through one complete
cycle.
Flood hazard. May cause personal injury or prop-
erty damage. Failure to make this operational check can lead to
improper operation, premature pump failure and flooding.
To Replace the Vertical Float Switch:
NOTICE: The float must be able to complete its entire cycle
without interference from any other object.
1. Mount the bracket on the switch housing with the bracket
mounting screws. See Figure 2.
Make sure the pin holds the float rod in the
switch housing; otherwise the pump will not shut off.
NOTICE: Pull gently on the rod to make sure that it cannot
come out of the switch housing.
4. Mount the switch assembly on the pump with the screw
provided.
5. Run the pump through one complete cycle to verify switch
operation is correct and that nothing interferes with the
switch’s operation.
Flood hazard. May cause personal injury or prop-
erty damage. Failure to make this operational check can lead to
improper operation, premature pump failure and flooding.
AIRLOCKS
When a pump airlocks, it runs but does not move any water.
An airlock will cause the pump to overheat and fail.
This pump has a small hole in the side of the pump housing.
See Figure 1. This is an anti-airlock valve. If you suspect an air-
lock, insert a hat pin or a pipe cleaner into the anti-airlock hole
to clean out the debris.
Anti-Airlock Valve
(Remove screen
and look under
pump for access)
Figure 1 – To clean the screen and anti-airlock valve.
Figure 2:Vertical Float Switch Replacement.
Troubleshooting / Repair Parts 5
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
SYMPTOM PROBABLE CAUSE(S) CORRECTIVE ACTION
Pump won’t start or run. Blown fuse or breaker. If blown, replace with fuse of proper size or reset breaker.
Low line voltage. If voltage under recommended minimum, check size of wiring from
main switch on property. If OK, contact power company or hydro authority.
Defective motor. Replace pump.
Defective float switch. Replace float switch.
Float obstructed. Remove obstruction.
Pump starts and stops Backflow of water from piping. Install or replace check-valve.
too often.
Faulty float switch. Replace float switch.
Pump won’t shut off. Defective float switch. Replace float switch.
Restricted discharge Remove pump and clean pump and piping.
(obstacle in piping).
Float obstructed. Remove obstruction.
Pump operates but Low line voltage. If voltage under recommended minimum, check size of wiring from main
delivers little or no water. switch on property. If OK, contact power company or hydro authority.
Worn or plugged impeller. Replace pump.
Anti airlock vent hole is plugged. Clean out the vent hole with a hat pin or pipe cleaner.
Key No. Part Description Qty. 2905-04 2955-04 2957-04
1 Power Cord 1 PS117-54-TSU PS117-54-TSU PS117-54-TSU
2 Cover, Motor Assembly 1 ** ** **
3 Inlet Screen 1 PS18-128P PS18-127P PS18-127P
4 Switch Assembly 1 FP18-15BD-P2 FP18-15BD-P2 FPS17-66*
REPAIR PARTS LIST
* Replacement vertical switch must be mounted on discharge pipe.
** If the motor fails, replace the pump.
1
2
3
4
5916 0109
1
2
3
4
5918 0109
2905-04
2955-04
2957-04
Warranty 6
RETAIN ORIGINAL RECEIPT FOR YOUR RECORDS.
LIMITED WARRANTY
SIMER warrants to the original consumer purchaser (“Purchaser” or “You”) of its products that they are free from defects in
material and workmanship for a period of twelve (12) months from the date of the original consumer purchase.
If, within twelve (12) months from the original consumer purchase, any such product shall prove to be defective, it shall be
repaired or replaced at SIMER’s option, subject to the terms and conditions set forth below.The original purchase receipt
and product warranty information label are required to determine warranty eligibility. Eligibility is based on purchase date of
original product – not the date of replacement under warranty.The warranty is limited to repair or replacement of product
only – Purchaser pays all removal, installation, labor, shipping, and incidental charges.
For parts or troubleshooting assistance, DO NOT return product to your retail store. Contact SIMER Customer Service at
1-800-468-7867 / 1-800-546-7867.
Claims made under this warranty shall be made by returning the product (except sewage pumps, see below) to the retail
outlet where it was purchased immediately after the discovery of any alleged defect. SIMER will subsequently take
corrective action as promptly as reasonably possible. No requests for service will be accepted if received more than
30 days after the warranty expires.
SEWAGE PUMPS
DO NOT return a sewage pump (that has been installed) to your retail store. Contact SIMER Customer Service. Sewage
pumps that have seen service and been removed carry a contamination hazard with them.
If your sewage pump has failed:
Wear rubber gloves when handling the pump;
For warranty purposes, return the pump’s cord tag and original receipt of purchase to the retail store;
Dispose of the pump according to local disposal ordinances.
Exceptions to the Twelve (12) Month Limited Warranty
Product Warranty Period
BW85P, CM10, CMK, M40, M40P 90 days
2300, 2310, 2330, 2520ULST, 2943, 2955, 2956, 2957, 2960, 5023SS, A5500 2 Years
4” Submersible Well Pumps, 2945, 2958, 2975PC, 2985, 3075SS, 3983, 3984 3 Years
Pre-Charge Water System Tank, 3985, 3986 5 Years
3963, 3988, 3995, 3997 Lifetime
General Terms and Conditions
You must pay all labor and shipping charges necessary to replace product covered by this warranty.This warranty does not
apply to the following: (1) acts of God; (2) products which, in SIMER’s sole judgement, have been subject to negligence,
abuse, accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation, maintenance or
storage; (4) atypical or unapproved application, use or service; (5) failures caused by corrosion, rust or other foreign
materials in the system, or operation at pressures in excess of recommended maximums.
This warranty sets forth SIMER’s sole obligation and purchaser’s exclusive remedy for defective products.
SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES
WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED
WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE
DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an
implied warranty lasts, so the above limitations or exclusions may not apply to You.This warranty gives You specific legal
rights and You may also have other rights which vary from state to state.
SIMER • 293 Wright Street • Delavan,WI U.S.A. 53115
Phone: 1-800-468-7867 / 1-800-546-7867 • Fax: 1-800-390-5351
E-Mail: [email protected]Web Site: http://www.simerpumps.com
/