INSTALLATION GUIDELINES
BODY SPRAY BAR
REGULATOR BODY SPRAY BAR WITH LEVER HANDLE
STYLES
RGBS01 RGBS02 [SHOWN]
IMPORTANT:
¾To ensure this product is installed properly, you must read and follow
these guidelines.
¾The owner/user of this product must keep this information for future
reference.
¾This product must be installed by a professional licensed contractor
and must be on-site prior to rough-in. This allows the installer to
visualize the installation and verify the 25-5/8” ± 1/8” [651mm ±
3mm] inlet supply on-center spread.
¾Be sure your installation conforms to all federal, state, and local
codes.
Anti-scald protection is the responsibility of the installer and
according to applicable codes.
A water temperature limiting device is the responsibility of the
installer and must be in accordance with ASSE 1070.
In the State of Massachusetts, all installations must comply with
the rules and regulations set forth within 248 CMR.
¾Inspect this product to ensure it is the correct model and you have
all the parts required for proper installation.
¾Product is sold partially assembled but shown fully disassembled
for illustrative and service purposes only.
¾Use only a strap wrench or protected/smooth-jaw wrench on any finished surface.
¾The use of certain plumber’s putty may stain stone or tile surfaces.
¾If further assistance is required, please contact Product Support at 1-800-927-2120 Monday
through Friday, 8am – 6pm EST.
¾Refer to the separate Service Parts Documents for available replacement parts.
TECHNICAL DETAILS:
DETAIL SPECIFICATION
ADJUSTABLE VERSUS FIXED SPRAY FIXED
INLET CONNECTION 3/4” COPPER COMPRESSION
INTEGRATED DIVERTER NO
PIVOT YES
WATER PRESSURE RANGE 20psi [1.5 bar] MIN, 85psi [6.0 bar] MAX
WATER PRESSURE RECOMMENDED 45psi [3.0 bar]
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 2 OF 3 | UPDATED ON 11.28.2023
INSTALLATION GUIDELINES
BODY SPRAY BAR
[WATER
SUPPLY]
FINISHED
WALL
PRESSURE
BALANCING
LOOP
"C"
INLET SUPPLY
CENTER SPREAD
"A"
FITTINGS
HOLE
"B"
FRONT FACE OF
PIPE IN FRONT OF
FINISHED WALL
3/4"
COPPER
SUPPLY [x2]
ROUGH-IN:
¾Determine the ideal location for the SPRAY BAR, run well supported
3/4” copper supply lines for MAXIMUM water flow, plumb a pressure
balancing loop, and flush out supply lines to clear out any debris.
¾WARNING: If the rough-in is not accurate it will make installation
difficult or impossible. Verify the supply lines are secure, level,
perpendicular to the finished wall, parallel to each other, at the
proper spread of 25-5/8” ± 1/8” [651mm ± 3mm], and at equal
depths.
¾IMPORTANT: The supply lines MUST project a MINIMUM of 2”
[51mm] from the surface of the finished wall.
DIMENSION VALUE
A1-1/8”
[29mm]
B2”
[51mm]
C25-5/8” ± 1/8”
[651mm ± 3mm]
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 3 OF 3 | UPDATED ON 11.28.2023
FINISHED WALL
COMPRESSION
NUT
[x2]
ESCUTCHEON †
[x2]
† O-RINGS for the ESCUTCHEONS are
provided. If desired, a bead of caulk or
clear silicone may be applied where the
ESCUTCHEONS contact the finished wall.
[CHECK FOR LEAKS!]
‡ HANDLE does NOT turn
on, off or divert water.
* TURN ON
WATER
HANDLE ‡
FINISHED WALL
3/4" COPPER SUPPLY
COMPRESSION RING
O-RING
COMPRESSION NUT
[WITH ESCUTCHEON]
COMPRESSION
NUT
ESCUTCHEON
[INTERNAL O-RING]
O-RING
SPRAY
BAR
COMPRESSION
RING
FINISHED WALL
1-1/4" +/- 1/8"
[32mm +/- 3mm]
FRONT FACE OF
PIPE IN FRONT OF
FINISHED WALL
3/4"
COPPER
SUPPY [x2]
SPRAY BAR
HANDLE
[CAN BE
INSTALLED
ON THE
BOTTOM]
COMPRESSION
NUT
[SECURELY
TIGHTEN x2]
FLOW
REGULATOR
[x2]
INSTALLATION GUIDELINES
BODY SPRAY BAR
6. Slide the ESCUTCHEONS down the COMPRESSION
NUTS until they contact the finished wall.
5. Turn on the water and a diverter/wall valve (sold
separately), operate the HANDLE to ensure it
functions properly, and inspect all connections for
leaks then turn the water off.
NOTE: The HANDLE does NOT turn on, off, or divert
water. It ONLY adjusts the spray direction.
4. Slide the BAR over the SUPPLIES then thread and
securely tighten the COMPRESSION NUTS onto
the BAR. The SPRAY BAR can be installed with the
HANDLE on the top or bottom.
NOTE: FLOW REGULATORS are located in the inlets
of the SPRAY BAR. Replacement REGULATORS
(STYLE No. 100343) can be ordered separately.
3. Slide the O-RING, COMPRESSION NUTS with the
ESCUTCHEONS, and COMPRESSION RINGS onto
the SUPPLIES.
2. Slide the ESCUTCHEONS up the COMPRESSION
NUTS then unthread and remove the NUTS from
the SPRAY BAR.
NOTE: Do NOT discard the O-RINGS or
COMPRESSION RINGS.
1. Ensure the SUPPLIES project a final length of 1-1/4”
± 1/8” [32mm ± 3mm] from the surface of the
finished wall.