Comnet FVT/FVR10C1, FVR20C2 and FVR40C4 Series User manual

Type
User manual

Comnet FVT/FVR10C1, FVR20C2 and FVR40C4 Series are single, dual or quad-channel 10-bit digitally encoded short-haul video and contact closure transmitters and receivers that support the transmission of one, two, or four independent short-haul quality 10-bit digital video signals and one, two, or four contact closures in the direction of the video over multimode or single mode optical fibers. These modules are universally compatible with major CCTV camera manufacturers. The receivers are compatible with the FVT1(M,S)1/M* series single channel transmitters.

Comnet FVT/FVR10C1, FVR20C2 and FVR40C4 Series are single, dual or quad-channel 10-bit digitally encoded short-haul video and contact closure transmitters and receivers that support the transmission of one, two, or four independent short-haul quality 10-bit digital video signals and one, two, or four contact closures in the direction of the video over multimode or single mode optical fibers. These modules are universally compatible with major CCTV camera manufacturers. The receivers are compatible with the FVT1(M,S)1/M* series single channel transmitters.

INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE
1
TECH SUPPORT: 1.888.678.9427
The ComNet
series video transmitters and receivers support the transmission of one,
two, or four independent short-haul quality 10-bit digital video signals and one, two,
or four contact closures in the direction of the video over multimode or single mode
optical fibers. These modules are universally compatible with major CCTV camera
manufacturers. The receivers are compatible with the FVT1(M,S)1/M* series single
channel transmitters. Plug-and-play design ensures ease of installation and no electrical
or optical adjustments are ever required.
Bi-color (Red/Green) LED indicators are provided for rapidly confirming operating
status. Please see Figure 10 on Page 7 for LED explanations.
The FVT10C1(M,S)1/M units have a small footprint and are ideal for mounting where
space is limited or can be mounted inside equipment housing. The remaining ComFit
units may be either wall or rack-mounted. Please see Figures A and B on Page 8 for
mounting instructions.
* FVT1(M,S)1/M not available in North America.
INSTALLATION AND OPERATION MANUAL
FVT/FVR10C1(M,S)1[/M],
FVR20C2(M,S)2 & FVR40C4(M,S)4
SINGLE, DUAL OR QUAD-CHANNEL 10-BIT DIGITALLY ENCODED
SHORT-HAUL VIDEO AND CONTACT CLOSURE
This manual serves the following
ComNet Model Numbers:
FV T10C1M1/M
FV T10C1S1/M
FV T10C1M1
F V T10C1S1
FVR10C1M1
F VR10C1S1
FVR20C2M2
FVR20C2S2
FVR40C4M4
FVR40C4S4
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE
2
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
BNC
Video
Power Input &
Contact Closure
Power Supply:
9 – 36VDC @ 2W
OR
12 – 24 VAC @ 2W
FIGURE 2 – FVT10C1/M TRANSMITTER
FIGURE 1 – FVT10C1/M TRANSMITTER
REAR PANEL
FRONT PANEL
Multimode or Single Mode
Optical Fiber
Mounting
Bracket
(Included)
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE
3
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
FIGURE 3 – FVT10C1 TRANSMITTER
FIGURE 2 – FVT10C1 TRANSMITTER
REAR PANELFRONT PANEL
Multimode or Single Mode Optical Fiber
Video Signal In
Contact In
Black
Black With White Stripe
Power Supply:
Surface Mount: 8 – 15VDC @ 2W
Rack Mount: From Rack
NOTE: Remove Electrical
Connector for Rack
Mount Units
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE
4
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
FIGURE 5 – FVR10C1 RECEIVER
FIGURE 4 – FVR10C1 RECEIVER
REAR PANELFRONT PANEL
Multimode or Single Mode
Optical Fiber
Video Signal Out
Contact Out
Black
Black With White Stripe
Power Supply:
Surface Mount: 8 – 15VDC @ 2W
Rack Mount: From Rack
NOTE: Remove Electrical
Connector for Rack
Mount Units
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE
5
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
Video Signal Out
CHANNEL 1CHANNEL 2
Video Signal Out
Contact Out
Contact Out
FIGURE 7 – FVR20C2 RECEIVER
FIGURE 6 – FVR20C2 RECEIVER
REAR PANELFRONT PANEL
Multimode or Single
Mode Optical Fiber
Black
Black With White Stripe
Power Supply:
Surface Mount: 8 – 15VDC @ 2W
Rack Mount: From Rack
NOTE: Remove Electrical
Connector for Rack
Mount Units
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE
6
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
CH1 Video
Signal Out
CH2 Video
Signal Out
CH3 Video
Signal Out
CH4 Video
Signal Out
Contact Out
Contact Out
FIGURE 9 – FVR40C4 RECEIVER
FIGURE 8 – FVR40C4 RECEIVER
REAR PANELFRONT PANEL
Multimode or
Single Mode
Optical Fiber
Black
Black With White Stripe
Operating Voltage
Range: 8 to 15VDC
Power Consumption: 4W
NOTE: Remove Electrical
Connector for
Rack Mount Units
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE
7
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
FIGURE 10 – LED INDICATORS
LINK (RECEIVERS ONLY) VIDEO CONTACT*
GREEN Communication link has been
established over optical fiber
Video signal is present on the
channel.
Contact input is closed.
RED Communication link has not
been established.
Video signal is not present on the
channel.
OFF Unit powered down. Unit powered down. Contact input is open.
* Contact Closure channels are not operational when used with the FVT1(M,S)1/M transmitters.
INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14 PAGE
8
INSTALLATION AND OPERATION MANUAL FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4
TECH SUPPORT: 1.888.678.9427
© 2014 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC.
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA
T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE
T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
FIGURE B
Dimensions are for a standard ComNet™ one slot module
.156 [3.96 mm]
.313 [7.95 mm]
INSTALLATION CONSIDERATIONS
The FVT10C1(M,S)1/M is supplied as a Standalone/Surface Mount module.
The remaining units covered in this manual are supplied as Standalone/
Rack (ComFIt) modules. Units should be installed in dry locations
protected from extremes of temperature and humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the
power supply be turned off and that the rack power supply is disconnected
from any power source. Note: Remove electrical connector before
installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the
card guides in the rack until the edge connector at the back of the card
seats in the corresponding slot in the rack’s connector panel. Seating
may require thumb pressure on the top and bottom of the cards front
panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the
card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-
unit rack assembly, the operating ambient temperature of the
rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should
be such that the amount of air flow required for safe operation of the
equipment is not compromised.
FIGURE A
Dimensions are for a ComNet™ FVT10C1/M module
4.5in
(11.7cm)
2.2in
(5.5cm)
1.1in
(2.7cm)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Comnet FVT/FVR10C1, FVR20C2 and FVR40C4 Series User manual

Type
User manual

Comnet FVT/FVR10C1, FVR20C2 and FVR40C4 Series are single, dual or quad-channel 10-bit digitally encoded short-haul video and contact closure transmitters and receivers that support the transmission of one, two, or four independent short-haul quality 10-bit digital video signals and one, two, or four contact closures in the direction of the video over multimode or single mode optical fibers. These modules are universally compatible with major CCTV camera manufacturers. The receivers are compatible with the FVT1(M,S)1/M* series single channel transmitters.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI