Kichler Lighting 44098CLP User manual

Type
User manual

Kichler Lighting 44098CLP is a versatile lighting fixture designed to enhance your indoor spaces with its elegant style. This 4-light semi-flush mount fixture is crafted with a Brushed Nickel finish, adding a touch of sophistication to your decor. It features adjustable arms and pivoting shades, allowing you to direct light exactly where you need it. Compatible with incandescent or LED bulbs (not included), this fixture offers energy-efficient lighting options to suit your preference.

Kichler Lighting 44098CLP is a versatile lighting fixture designed to enhance your indoor spaces with its elegant style. This 4-light semi-flush mount fixture is crafted with a Brushed Nickel finish, adding a touch of sophistication to your decor. It features adjustable arms and pivoting shades, allowing you to direct light exactly where you need it. Compatible with incandescent or LED bulbs (not included), this fixture offers energy-efficient lighting options to suit your preference.

Date Issued: 09/12/17 IS-44098-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
Note: Portions of installation will require (2) people
1) Passxturewirethroughlongthreadedpipe[1](with2hexnuts
onit).
2) Screwthepipeintothehexcoupling[2]allthewaydownuntil
thehexnuttouchesthecoupling.
3) Passthexturewirethroughthewideopeningofthetopcov-
er[3].Restthecoverontothetophousing[4].(Somethreads
shouldbeexposedfromthetop.Youcanadjustthehexnutsto
seatproperly).
4) Passthexturewirethroughthesmallcoupling[5].Screwthe
couplingontotheexposedthreadsfromthetopofthecover.
Tightentosecure.
5) Passxturewirethroughdesiredamountofstems[6]and
screwstemstogetherusingsuppliedshortthreadedtubes[7].
NOTE:Threadlockingcompoundmustbeappliedtoallstem
threadsasnotedwitharrowsymboltopreventaccidentalrota-
tionofxtureduringcleaning,relamping,etc.
6) Passxturewirethroughendofswivel[8]withoutthreaded
pipe.Threadthatendofswivelontoendoflaststem.
NOTE:Directionofswivelinaccordancewithceiling.
7) Passxturewirethroughholeincanopy[9].Passthreaded
pipeonendofswivelupthroughholeincanopy.
8) Passxturewirethroughlockwasher[10].Threadlockwasher
ontoendofthreadedpipeprotrudingfrominsidecanopy.
9) Passxturewirethroughhexnut[11].Threadhexnutontoend
ofthreadedpipe.
10) Findtheappropriatethreadedholesonmountingstrap[12].
Assemblemountingscrews[13]intothreadedholes.
11)Attachmountingstraptooutletbox[14].Mountingstrapcan
beadjustedtosuitpositionofxture.
12)Groundinginstructions:(SeeIllus.AorB).
A) Onxtureswheremountingstrapisprovidedwithahole
andtworaiseddimples.Wrapgroundwirefromoutletbox
aroundgreengroundscrew,andthreadintohole.
B) Onxtureswhereacuppedwasherisprovided.Attach
groundwirefromoutletboxundercuppedwasherand
greengroundscrew,andthreadintomountingstrap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wiretooutletboxgroundwirewithwireconnector.(Notpro-
vided.)Afterfollowingtheabovesteps.Neverconnectground
wiretoblackorwhitepowersupplywires.
13)Makewireconnections(connectorsnotprovided.)Reference
chartbelowforcorrectconnectionsandwireaccordingly.
14)Pushxturetoceiling,carefullypassingmountingscrews
throughholesincanopy.NOTE:Becertainwiresdonotget
pinchedbetweencanopyandceiling.
15)Useknobs[15]andlockwashers[16]tosecurecanopy.Tighten
tosecure.
16) Insertrecommendedbulb.(Notsupplied)
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
1
2
3
4
5
6
7
8
9
10
11
13
12
14
15
16
17
18
19
20
21
22
23
17) Carefullylowertheglass[17]ontothelowertrim.
18) Using(2)people,raisethelowertrim/glassuptothetophous-
ing.Slipthetophousingarms[18]insidetheslotofthelower
trimsupportarms[19].Aligntheholesofthetophousingarms
withtheholesinthelowertrimarms.
19) Slideasupportarmscrew[20]throughtheholeinanarm.
Screwanial[21]ontothescrew.Repeatthisstepforremain-
ingarms.
20) Tightentosecurethetrimtothearms.
Date Issued: 09/12/17 IS-44098-CB
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
Nous sommes là pour vous aider 866-558-5706
Heures : du lundi au vendredi, de 9h à 17h (heure de l’Est)
ATTENTION – RISQUE DE DÉCHARGES ÉLECTRIQUES -
Couper le courant au niveau du panneau du disjoncteur du
circuit principal ou de la boîte à fusibles principale avant de
procéder à l’installation.
Remarque: Des portions d’installation nécessiteront
(2) personnes.
1) Passez le l de xation à travers le tuyau leté long [1] (avec 2
écrous hexagonaux dessus).
2) Vissez le tuyau dans l’accouplement hexagonal [2] complète-
ment jusqu’à ce que l’hexagone touche le couplage.
3) Passez le l de xation à travers l’ouverture large du couvercle
supérieur [3]. Reposer le couvercle sur le boîtier supérieur
[4]. (Certains ls doivent être exposés du haut. Vous pouvez
ajuster les écrous hexagonaux pour s’asseoir correctement).
4) Passez le l de xation à travers le petit accouplement [5]. Vis-
sez l’accouplement sur les ls exposés du haut du couvercle.
Serrez pour sécuriser.
5) Passer le l de xation à travers la quantité souhaitée de tiges
[6] et la visdérive en utilisant des tubes à letage court fournis
[7]. REMARQUE: le composé de verrouillage de letage doit
être appliqué à tous les ls de la tige comme indiqué avec
un symbole éché pour empêcher la rotation accidentelle du
luminaire pendant le nettoyage, la relamping, etc.
6) Passer le l de xation à travers l’extrémité de pivotement sans
tuyau leté [8]. Enlez l’extrémité de pivotement sur l’extrémité
de la dernière tige.
NOTE pivotante en conformité avec le plafond.
7) Faire passer le l de xation à travers le trou dans la canopée
[9]. Passez tuyau leté sur l’extrémité de pivot dans le trou de
la canopée.
8) Faire passer le l de xation dans le trou de la rondelle d’arrêt
[10]. Enler la rondelle d’arrêt sur l’extrémité du tuyau leté
faisant saillie à l’intérieur de la canopée.
9) Faire passer le l de xation dans le trou du hexnut [11]. En-
lez hexnut sur l’extrémité du tuyau leté.
10) Trouvez les trous taraudés appropriés sur sangle de xation
[12]. Monter les vis de montage dans les trous letés [13].
11) Attachez la sangle de xation à la boîte de sortie [14]. (Vis non
fournies). sangle de xation peut être ajustée en fonction de la
position de montage.
12) Connecter les ls. Se porter au tableau ci-dessous pour faire les
connexions.
13) Poussez xation au plafond, en passant soigneusement les vis
de montage à travers des trous dans la canopée.
14) Utilisez les boutons [15] et les systèmes de verrouillage [16]
pour sécuriser le voile. Serrez pour sécuriser.
15) Insérez l’ampoule recommandée (Non fourni).
16) Abaissez soigneusement le verre [17] sur la garniture inféri-
eure.
17) En utilisant (2) personnes, élevez la garniture / verre inférieure
vers le haut du boîtier. Glissez les bras supérieurs du boîtier
[18] à l’intérieur de la fente des bras de support inférieur [19].
Alignez les trous des bras supérieurs du boîtier avec les trous
dans les bras inférieurs.
18) Faites glisser une vis du bras de support [20] à travers le trou
dans un bras. Vissez une nie [21] sur la vis. Répétez cette
étape pour les bras restants.
19) Serrer pour xer la garniture aux bras.
Connecter le fil noir ou
rouge de la boite
Connecter le fil blanc de la boîte
A Noir A Blanc
*Au cordon parallèle (rond et lisse)
*Au cordon parallele (à angles droits el strié)
Au bransparent, doré, marron, ou
noir sans fil distinctif
Au transparent, doré, marron, ou
noir avec un til distinctif
Fil isolé (sauf fil vert) avec
conducteur en cuivre
Fil isolé (sauf fil vert) avec
conducteur en argent
*Remarque: Avec emploi d’un fil paralléle
(SPT I et SPT II). Le fil neutre est á angles
droits ou strié et l’autre fil doit étre rond ou
lisse (Voir le schéma).
Fil Neutre
1
2
3
4
5
6
7
8
9
10
11
13
12
14
15
16
17
18
19
20
21
22
23
  • Page 1 1
  • Page 2 2

Kichler Lighting 44098CLP User manual

Type
User manual

Kichler Lighting 44098CLP is a versatile lighting fixture designed to enhance your indoor spaces with its elegant style. This 4-light semi-flush mount fixture is crafted with a Brushed Nickel finish, adding a touch of sophistication to your decor. It features adjustable arms and pivoting shades, allowing you to direct light exactly where you need it. Compatible with incandescent or LED bulbs (not included), this fixture offers energy-efficient lighting options to suit your preference.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages