Heat & Glo LifeStyle SL-750TRS-IPI-D User manual

Category
Fireplaces
Type
User manual
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
1
Models:
SL-750TRS-IPI-D
SL-550TRS-IPI-D
SL-350TRS-C
Owners Manual
Installation and Operation
Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
- If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing proper-
ty damage, personal injury, or death.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fixed glass panel. Do
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
WARNING
Keep children away.
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high
temperatures.
Do NOT operate with protective barriers open or
removed.
Keep clothing, furniture, draperies and other
combustibles away.
Glass and other surfaces are hot during
operation and cool down.
DO NOT DISCARD THIS MANUAL
CAUTION
Important operating and
maintenance instruc-
tions included.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must
be installed in accordance with the manufacturer’s instruc-
tions and the manufactured home construction and safety
standard, Title 24 CFR, Part 3280 or Standard for Installa-
tion in Mobile Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indi-
cated on the rating plate.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory-trained
professionals, or technicians supervised
by an NFI certified professional.
••
DO NODO NO
DO NODO NO
DO NO
TT
TT
T
DISCARDDISCARD
DISCARDDISCARD
DISCARD
Read, understand and follow
these instructions for safe
installation and operation.
Leave this manual with
party responsible for
use and operation.
In the Commonwealth of Massachusetts:
installation must be performed by a licensed plumber or
gas fitter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Í
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
2
These units MUST use one of the vent systems
described in the Installing the Appliance section of
the Installers Guide. NO OTHER vent systems or
components MAY BE USED.
This gas appliance and vent assembly MUST be
vented directly to the outside and MUST NEVER be
attached to a chimney serving a separate solid fuel
burning appliance. Each gas appliance MUST USE
a separate vent system. Common vent systems are
PROHIBITED.
INSPECT the external vent cap on a regular basis to
make sure that no debris is interfering with the air
flow.
The glass door assembly MUST be in place and
sealed, and the trim door assembly MUST be in
place on the appliance before the unit can be
placed into safe operation.
DO NOT OPERATE this appliance with the glass
door removed, cracked, or broken. Replacement of
the glass door should be performed by a licensed
or qualified service person. DO NOT strike or slam
the glass door.
The glass door assembly SHALL ONLY be
replaced as a complete unit, as supplied by the gas
appliance manufacturer. NO SUBSTITUTE material
may be used.
DO NOT USE abrasive cleaners on the glass door
assembly. DO NOT ATTEMPT to clean the glass
door when it is hot.
Turn off the gas before servicing this appliance. It is
recommended that a qualified service technician
perform an appliance check-up at the beginning of
each heating season.
Any safety screen or guard removed for servicing
must be replaced before operating this appliance.
DO NOT place furniture or any other combustible
household objects within 36 inches of the
appliance front.
READ and UNDERSTAND all instructions carefully
before starting the installation. FAILURE TO
FOLLOW these installation instructions may result
in a possible fire hazard and will void the warranty.
Prior to the first firing of the appliance, READ the
Using Your Appliance section of the Owners Guide.
DO NOT USE this appliance if any part has been
under water. Immediately CALL a qualified service
technician to inspect the unit and to replace any part
of the control system and any gas control which has
been under water.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
Installation and repair should be PERFORMED by a
qualified service person. The appliance and venting
system should be INSPECTED before initial use
and at least annually by a professional service
person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding
material, etc. It is IMPERATIVE that the unit’s
control compartment, burners, and circulating air
passageways
BE KEPT CLEAN to provide for
adequate combustion and ventilation air.
Always KEEP the appliance clear and free from
combustible materials, gasoline, and other
flammable vapors and liquids.
NEVER OBSTRUCT the flow of combustion and
ventilation air. Keep the front of the appliance
CLEAR of all obstacles and materials for servicing
and proper operations.
Due to the high temperature, the appliance should
be LOCATED out of traffic areas and away from
furniture and draperies. Clothing or flammable
material SHOULD NOT BE PLACED on or near the
appliance.
Children and adults should be ALERTED to the
hazards of high surface temperature and should
STAY AWAY to avoid burns or clothing ignition.
Young children should be CAREFULLY SUPERVISED
when they are in the same room as the appliance.
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
SAFETY AND WARNING INFORMATION
!
!
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
3
TABLE OF CONTENTS
Safety and Warning Information ......................................................... 2
Service Parts Lists ................................................................................. 4
Section 1: Approvals and Codes........................................................ 12
Appliance Certification ........................................................................... 12
Installation Codes .................................................................................. 12
High Altitude Installations ...................................................................... 12
Requirements for the Commonwealth of Massachusetts........................ 13
Section 2: Getting Started .................................................................. 14
Introducing the Heat & Glo Gas Appliances ........................................... 14
Pre-installation Preparation .................................................................... 14
Section 3: Installing the Appliance ................................................... 18
Constructing the Appliance Chase ......................................................... 18
Step 1 Locating the Appliance.......................................................... 18
Step 2 Framing the Appliance .......................................................... 19
Step 3 Installing the Vent System .................................................... 22
A. Vent System Approvals ................................................... 22
B. Installing Vent Components............................................. 32
C. Vent Termination.............................................................. 35
Step 4 Positioning, Leveling, and
Securing the Appliance ......................................................... 38
Step 5 The Gas Control Systems..................................................... 38
Step 6 The Gas Supply Line............................................................. 39
Step 7 Gas Pressure Requirements ................................................. 39
Step 8 Wiring the Appliance ............................................................. 40
Step 9 Finishing ............................................................................... 42
Step 10 Installing Trim, Logs, and Ember Material ............................. 43
Installing the Trim.................................................................. 43
Positioning the Logs ............................................................. 43
Shutter Settings.................................................................... 43
Placing the Ember Material................................................... 43
Glass Specifications ............................................................. 43
Step 11 Before Lighting the Appliance ................................................ 44
Step 12 Lighting the Appliance ........................................................... 44
After the Installation ............................................................................... 44
Section 4: Maintaining and Servicing Your Appliance ................... 45
Î = Contains updated information.
Î
Î
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
4
(NG, LP) Exploded Parts Diagram
Service Parts
SL-350TRS-C
Beginning Manufacturing Date: 4-01
Ending Manufacturing Date: ______
Part number list on following page.
13
6
2
3
4
5
7 Log Set Assembly
12
8
11
10
9
14
15
1
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
5
(NG, LP) Service Parts List
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order-
ing, supply serial and model numbers to ensure correct service parts.
SL-350TRS-C
ITEM STANDING PILOT SERIAL # PART NUMBER
Burner Orifice NG (#43C) 582-843
Burner Orifice LP (#53C) 582-853
1 Glass Door Assembly GLA-350TRS
2Burner NG, LP 540-234A
3 Mesh Panel Door 540-382A
4 Log Grate 540-361A
5 Base Refractory
PRE 4/06
POST 4/06
540-206T (Tan)
2065-206 (Black)
6 Hood SRV540-174
7 Log Set Assembly LOGS-350
8 Log 1 SRV530-701
9 Log 2 SRV530-704
10 Log 3 SRV540-702
11 Log 4 SRV530-705
12 Log 5 SRV530-703
13 Junction Box
PRE 00251404
POST 00251404
100-250A
4021-013
14 Louver, Top 540-256A
15 Louver, Bottom 540-257A
Pilot Orifice NG 446-505
Pilot Orifice LP 446-517
Thermocouple 446-511
Thermopile 060-512
Conversion Kit NG NGK-350TRS-C
Conversion Kit LP LPK-350TRS-C
Vermiculite Embers MYSTIC-EMBERS
Exhaust Restrictor 530-299
Glass Latch Assembly 386-122A
Mineral Wool 050-721
Touch up Paint TUP-GBK-12
Also see additional pages for valve assembly service part numbers.
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
6
(NG, LP) Exploded Parts Diagram
Service Parts
Beginning Manufacturing Date: 4-01
Ending Manufacturing Date: ______
SL-350TRS-C
ITEM DESCRIPTION SERIAL # PART NUMBER
1Piezo Ignitor 291-513
2 Burner Neck Gasket 2045-407
3 Thermostat Wire Assembly
PRE 00251404
POST 00251404
N/A
2045-024
4 Pilot Assembly NG 530-510A
4 Pilot Assembly LP 530-511A
5 Valve Bracket 2025-101
6 Valve Plate Gasket 530-431
7 Flex Ball Valve Assembly 302-320A
8Valve NG 060-522
8 Valve LP 060-523
9 Flexible Gas Connector
PRE 22099930
POST 22099930
567-301A
530-302A
10 Pilot Bracket 530-164
ON/OFF Rocker Switch
PRE 00251404
POST 00251404
060-511
N/A
Wire Assembly
PRE 00251404
POST 00251404
049-552A
N/A
Standing Pilot Ignition
Valve Assembly
10
1
4
7
3
5
8
9
6
2
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
7
(NG, LP) Exploded Parts Diagram
Service Parts
SL-550TRS-IPI-D
Beginning Manufacturing Date: 4-04
Ending Manufacturing Date: ______
7 Log Set Assembly
Part number list on following page.
9
8
10
11
12
14
1
15
13
4
5
6
3
2
Î
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
8
(NG, LP) Service Parts List
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,
supply serial and model numbers to ensure correct service parts.
SL-550TRS-IPI-D
ITEM DESCRIPTION SERIAL # PART NUMBER
Burner Orifice NG (#38C) 582-838
Burner Orifice LP (#53C) 582-853
1 Junction Box 4021-013
2Burner NG 2065-005
2Burner LP 2065-006
3 Glass Door Assembly GLA-550TRS
4 Log Grate 2066-036
5 Base Refractory NG, LP 2065-100
6 Hood SRV550-175
7 Log Set Assembly LOGS-550TRS-D
8 Log 1 SRV2065-701
9 Log 2 SRV2065-702
10 Log 3 SRV2065-703
11 Log 4 SRV2065-704
12 Log 5 SRV2065-705
Refractory Kit BRICK-550TRS-D
13 Refractory, Back SRV2044-711
14 Refractory, Left Side SRV2044-710
15 Refractory, Right Side SRV2044-712
Pilot Orifice NG 446-505
Pilot Orifice LP 446-517
Thermocouple 446-511
Thermopile 060-512
Mineral Wool 050-721
Glass Latch 386-122A
Exhaust Restrictor 530-299
Touch up Paint TUP-GBK-12
ACCESSORIES
Fan Kit GFK-160A
Extended Vertical Baffle Kit BAF-VERT
Wall Switch Kit, Off-white WSK-21
Wall Switch Kit, White WSK-21-W
Conversion Kit NG NGK-550TRS-IPID
Conversion Kit LP LPK-550TRS-IPID
Vermiculite Embers MYSTIC-EMBERS
Also see additional pages for valve assembly service part numbers.
Í
Í
Í
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
9
(NG, LP) Exploded Parts Diagram
Service Parts
SL-750TRS-IPI-D
Beginning Manufacturing Date: 4-04
Ending Manufacturing Date: ______
Part number list on following page.
9
8
12
11
10
7 Log Set Assembly
14
1
15
13
4
5
6
3
2
Î
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
10
(NG, LP) Service Parts List
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order-
ing, supply serial and model numbers to ensure correct service parts.
SL-750TRS-IPI-D
ITEM DESCRIPTION SERIAL # PART NUMBER
Burner Orifice NG (#36C) 582-836
Burner Orifice LP (#52C) 582-852
1 Junction Box 4021-013
2 Burner NG 2066-005
2 Burner LP 2065-006
3 Glass Door Assembly GLA-750TRS
4 Log Grate 2066-036
5 Base Refractory NG, LP 2066-100
6 Hood SRV530-175
7 Log Set Assembly LOGS-750TRS-D
8 Log 1 SRV2065-701
9 Log 2 SRV2066-702
10 Log 3 SRV2066-703
11 Log 4 SRV2066-704
12 Log 5 SRV2066-705
Refractory Kit BRICK-750TRS-D
13 Refractory, Back SRV2045-711
14 Refractory, Left Side SRV2045-710
15 Refractory, Right Side SRV2045-712
Mineral Wool 050-721
Glass Latch Assembly 386-122A
Exhaust Restrictor 530-299
Touch up Paint TUP-GBK-12
ACCESSORIES
Fan Kit GFK-160A
Extended Vertical Baffle Kit BAF-VERT
Wall Switch Kit, Off-white WSK-21
Wall Switch Kit, White WSK-21-W
Conversion Kit NG NGK-750TRS-IPID
Conversion Kit LP LPK-750TRS-IPID
Vermiculite Embers MYSTIC-EMBERS
Also see additional pages for valve assembly service part numbers.
Í
Í
Í
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
11
(NG, LP) Exploded Parts Diagram
Service Parts
Beginning Manufacturing Date: 4-04
Ending Manufacturing Date: ______
SL-750TRS-IPI-D, SL-550TRS-IPI-D
ITEM /
PIÈCE
DESCRIPTION
SERIAL #
/ N° DE SÉRIE
PART NUMBER
/ N° DE PCE
1 Burner Neck Gasket / Joint de Cou de Brûleur 2045-407
2 Thermostat Wire Assembly / L'Assemblée de Fil de thermostat 2045-024
3 Wire Assembly / Module de fil 2012-206
4 Pilot Assembly NG / Module de veilleuse GN 4021-025
4 Pilot Assembly LP / Module de veilleuse PL 4021-026
5 Valve Bracket / Parenthèse de Valve 2025-101
6 Ground Strap / Courroie de Raison(Terre) 385-512
7 Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle 302-320A
8Valve NG / Valve GN 750-500
8 Valve LP / Valve PL 750-501
9 Flexible Gas Connector / Tuyau à gaz flexible 530-302A
10 Module / Module 593-592
11 Wire Assembly / Module de fil 593-590A
12 Battery Pack / Paquet de Batterie(Pile) 593-594A
13 3 Volt Transformer / 3 Transformateur de Volt 593-593A
14 Valve Plate Gasket / Joint de Plat de Valve 530-431
15 Pilot Bracket / Parenthèse Pilote 2065-117
Intermittent Pilot Ignition
Valve Assembly
6
2
12
14
10
11
1
8
9
4
5
3
7
13
15
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
12
1
Approvals and
Codes
Heat & Glo Quality
Systems registered
by SGS ICS
Appliance Certification
The Heat & Glo appliance models discussed in this Installers
Guide have been tested to certification standards and listed
by the applicable laboratories.
Certification
MODELS: SL-750TRS-IPI-D, SL-550TRS-IPI-D,
SL-350TRS-C
LABORATORY: Underwriters Laboratories
TYPE: Direct Vent Gas Fireplace Heater
STANDARD: ANSI Z21.88•CSA2.33•UL307B
High Altitude Installations
U.L. Listed gas appliances are tested and approved with-
out requiring changes for elevations from 0 to 2,000 feet in
the U. S. A. and in Canada.
When installing this appliance at an elevation above 2,000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifice to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above a
2000 foot elevation in the U.S.A. or 10% for elevations
between 2000 and 4500 feet in Canada. If the heating value
of the gas has been reduced, these rules do not apply. To
identify the proper orifice size, check with the local gas
utility.
If installing this appliance at an elevation above 4,500 feet
(in Canada), check with local authorities.
NOTE: THESE MODELS ARE UL LISTED TO UL307B,
THE STANDARD FOR GAS-BURNING HEATING APPLI-
ANCES FOR MANUFACTURED HOMES AND RECRE-
ATIONAL VEHICLES.
Installation Codes
The appliance installation must conform to local codes.
Before installing the appliance, consult the local building
code agency to ensure that you are in compliance with all
applicable codes, including permits and inspections.
In the absence of local codes, the appliance installation
must conform to the National Fuel Gas Code ANSI Z223.1
(in the United States) or the CAN/CGA-B149 Installation
Codes (in Canada). The appliance must be electrically
grounded in accordance with local codes or, in the absence
of local codes with the National Electric Code ANSI/NFPA
No. 70 (in the United States), or to the CSA C22.1 Canadian
Electric Code (in Canada).
These models may be installed in a bedroom or bed-sitting
room in the U.S.A. and Canada.
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
13
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7)
feet above finished grade in the area of the venting, includ-
ing but not limited to decks and porches, the following re-
quirements shall be satisfied:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented
gas fueled equipment, the installing plumber or gasfitter
shall observe that a hard wired carbon monoxide detector
with an alarm and battery back-up is installed on the floor
level where the gas equipment is to be installed. In addi-
tion, the installing plumber or gasfitter shall observe that a
battery operated or hard wired carbon monoxide detector
with an alarm is installed on each additional level of the
dwelling, building or structure served by the side wall hori-
zontal vented gas fueled equipment. It shall be the respon-
sibility of the property owner to secure the services of qual-
ified licensed professionals for the installation of hard wired
carbon monoxide detectors.
In the event that the side wall horizontally vented gas fu-
eled equipment is installed in a crawl space or an attic, the
hard wired carbon monoxide detector with alarm and bat-
tery back-up may be installed on the next adjacent floor
level.
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply with
the above requirements; provided, however, that during said
thirty (30) day period, a battery operated carbon monoxide
detector with an alarm shall be installed.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance
with the above provisions shall comply with NFPA 720 and
be ANSI/UL 2034 listed and IAS certified.
Signage
A metal or plastic identification plate shall be permanently
mounted to the exterior of the building at a minimum height
of eight (8) feet above grade directly in line with the ex-
haust vent terminal for the horizontally vented gas fueled
heating appliance or equipment. The sign shall read, in
print size no less than one-half (1/2) inch in size, “GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB-
STRUCTIONS”.
Inspection
The state or local gas inspector of the side wall horizontally
vented gas fueled equipment shall not approve the installa-
tion unless, upon inspection, the inspector observes carbon
monoxide detectors and signage installed in accordance with
the provisions of 248 CMR 5.08(2)(a)1 through 4.
Exemptions
The following equipment is exempt from 248 CMR 5.08(2)(a)1
through 4:
The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition
of NFPA 54 as adopted by the Board; and
Product Approved side wall horizontally vented gas fu-
eled equipment installed in a room or structure sepa-
rate from the dwelling, building or structure used in whole
or in part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall hor-
izontally vented gas equipment provides a venting system
design or venting system components with the equipment,
the instructions provided by the manufacturer for installa-
tion of the equipment and the venting system shall include:
Detailed instructions for the installation of the venting
system design or the venting system components; and
A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall
horizontally vented gas fueled equipment does not provide
the parts for venting the flue gases, but identifies “special
venting systems”, the following requirements shall be sat-
isfied by the manufacturer:
The referenced “special venting system” instructions shall
be included with the appliance or equipment installation
instructions; and
The “special venting systems” shall be Product Approved
by the Board, and the instructions for that system shall
include a parts list and detailed installation instructions.
A copy of all installation instructions for all Product Ap-
proved side wall horizontally vented gas fueled equipment,
all venting instructions, all parts lists for venting instruc-
tions, and/or all venting design instructions shall remain
with the appliance or equipment at the completion of the
installation.
See Gas Connection section for additional Common-
wealth of Massachusetts requirements.
NOTE: The following requirements reference various
Massachusetts and national codes not contained in
this document.
Requirements for the Commonwealth of
Massachusetts
Î
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
14
2
Getting Started
Introducing the Heat & Glo Gas Appliances
Heat & Glo direct vent gas appliances are designed to op-
erate with all combustion air siphoned from outside of the
building and all exhaust gases expelled to the outside.
The information contained in this Installers Guide, unless
noted otherwise, applies to all models and gas control
systems. Gas appliance diagrams, including the dimensions,
are shown in this section.
Pre-install Preparation
This gas appliance and its components are tested and safe
when installed in accordance with this Installers Guide.
Report to your dealer any parts damaged in shipment,
particularly the condition of the glass. Do not install any
unit with damaged, incomplete, or substitute parts.
The vent system components and trim doors are shipped
in separate packages. The gas logs are packaged
separately and must be field installed.
Read all of the instructions before starting the
installation. Follow these instructions carefully during
the installation to ensure maximum safety and benefit.
Failure to follow these instructions will void the
owner’s warranty and may present a fire hazard.
The Heat & Glo Warranty will be voided by, and Heat & Glo
disclaims any responsibility for, the following actions:
Installation of any damaged appliance or vent system
component.
Modification of the appliance or direct vent system.
Installation other than as instructed by Heat & Glo.
Improper positioning of the gas logs or the glass door.
Installation and/or use of any component part not manu-
factured and approved by Heat & Glo, not withstanding
any independent testing laboratory or other party approval
of such component part or accessory.
ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE
HAZARD.
When planning a appliance installation, it’s necessary to
determine:
Where the unit is to be installed.
The vent system configuration to be used.
Gas supply piping.
Electrical wiring.
Framing and finishing details.
Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
If the appliance is to be installed on carpeting or tile, or on
any combustible material other than wood flooring, the
appliance should be installed on a metal or wood panel that
extends the full width and depth of the appliance.
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
15
Figure 1. Diagram of the SL-750TRS-IPI-D
HOOD
GAS
CONTROLS
GAS LINE
ACCESS
VENT COLLARS
TOP STANDOFFS
ELECTRICAL
ACCESS
RATING PLATES
& LABELS
BOTTOM GRILLE
COVER
CERAMIC
FIBER PAD
37-7/8
962[]
3-9/16
90
[]
6-7/8
175[]
35-5/8
905[]
41
1041.4[]
36-1/8
918[]
5-1/2
140[]
2-1/4
57[]
6
152[]
40
1016[]
8-3/4
222[]
16-1/4
413[]
1/2
13[]
15-7/8
403[]
15-3/8
391[]
30-3/4
781[]
ø6-5/8
168.3[]
GASS LINE
ACCESS
ELECTRICAL
ACCESS
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
16
Figure 2. Diagram of the SL-550TRS-IPI-D
32-9/16
827
[]
3-1/2
90
[
]
6-7/8
174[]
36
914[]
31-1/8
791
[
]
32-1/8
816[
]
5-1/2
140[
]
2-1/8
54[
]
6
152[]
35-7/16
900.1[
]
ø6-5/8
168.3
[
]
8-13/16
224[
]
16-1/4
413[
]
1/2
13[
]
15-7/8
403[
]
12-7/8
327[
]
25-3/4
654[
]
ELECTRICAL
ACCESS
ø 8
GAS LINE
ACCESS
168.3[
]
HOOD
GAS
CONTROLS
GAS LINE
ACCESS
VENT COLLARS
TOP STANDOFF
S
ELECTRICAL
ACCESS
RATING PLATES
& LABELS
BOTTOM GRILLE
COVER
CERAMIC
FIBER PAD
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
17
Figure 3. Diagram of the SL-350TRS-C
6-7/8
174[]
3-1/2
90[]
30-5/8
777[]
21-1/4
540[]
29
737[]
15-1/4
388[]
28-1/8
714[]
33
836[]
30-1/2
776[]
2-1/8
55[]
6
153[]
1/2
13[]
16-1/4
413[]
8-3/4
223[]
15-7/8
402[]
22-3/4 577[]
11-3/8
289[]
ø6-5/8
168.3[]
34-1/2
876[]
ø8 [203]
ELECTRICAL
ACCESS
GAS LINE
ACCESS
HOOD
GAS
CONTROLS
GAS LINE
ACCESS
VENT COLLARS
TOP STANDOFFS
ELECTRICAL
ACCESS
RATING PLATES
& LABELS
BOTTOM GRILLE
COVER
CERAMIC
FIBER PAD
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
18
3
Installing the Appliance
Step 1. Locating the Appliance
Space and clearance requirements for locating a appliance
within a room (see Figure 4).
Minimum Clearances
from the Appliance to Combustible Materials
For minimum clearances, see the direct vent termination
clearance diagrams in Figures 29 and 30 in this manual.
Minimum Clearances
from the Vent Pipe to Combustible Materials
Inches mm
Vertical Sections. ............. 1 ................ 25
Horizontal Sections
Top..................................... 3 ................ 75
Bottom ............................... 1 ................ 25
Sides ................................. 1 ................ 25
At Wall Firestops
Top .................................. 2 1/2 ............63.7
Bottom ..............................1/2............... 13
Sides ................................. 1 ................ 25
* The clearance to the ceiling is measured from the top
of the unit, excluding the standoffs (see Figure 37).
The distance from the unit to combustible construction is to
be measured from the unit outer wrap surface to the com-
bustible construction, NOT from the screw heads that se-
cure the unit together.
1/2 “ MIN. (13mm)
C
3” MIN. (76mm)
A
B
D
E
Clearance Requirements
The top and back of the appliance are defined by stand-
offs. The minimum clearance to a perpendicular wall
extending past the face of the appliance is 3 inches (76mm).
The back of the appliance may be recessed 16 1/4 inches
(413mm) into combustible construction.
Figure 4. Appliance Dimensions, Locations,
and Space Requirements
Constructing the Appliance Chase
A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. Vertical vents that run
on the outside of a building may be, but are not required to
be, installed inside a chase.
CAUTION: TREATMENT OF FIRESTOP SPACERS AND
CONSTRUCTION OF THE CHASE MAY VARY WITH THE
TYPE OF BUILDING. THESE INSTRUCTIONS ARE NOT
SUBSTITUTES FOR THE REQUIREMENTS OF LOCAL
BUILDING CODES. THEREFORE, YOUR LOCAL BUILD-
ING CODES MUST BE CHECKED TO DETERMINE THE
REQUIREMENTS FOR THESE STEPS.
Factory-built appliance chases should be constructed in
the manner of all outside walls of the home to prevent cold
air drafting problems. The chase should not break the out-
side building envelope in any manner.
This means that the walls, ceiling, base plate and cantilever
floor of the chase should be insulated. Vapor and air infiltra-
tion barriers should be installed in the chase as per regional
codes for the rest of the home. Additionally, in regions where
cold air infiltration may be an issue, the inside surfaces
may be sheetrocked and taped for maximum air tightness.
To further prevent drafts, the firestops should be caulked to
seal gaps. Gas line holes and other openings should be
caulked or stuffed with insulation. If the unit is being in-
stalled on a cement slab, a layer of plywood may be placed
underneath to prevent conducting cold up into the room.
THE CHASE SHOULD BE CONSTRUCTED SO THAT ALL
CLEARANCES TO THE APPLIANCE ARE MAINTAINED
AS SPECIFIED WITHIN THIS INSTALLERS GUIDE.
Inches mm
Glass Front..........................................36.... 914
Floor .....................................................0....... 0
Rear .................................................... 1/2 .... 13
Sides .................................................. 1/2 .... 13
*Top (SL-750TRS-IPI-D) ..........................................3 1/4... 83
(SL-550TRS-IPI-D, SL-350TRS-C) ...................1 1/2... 38
Ceiling**...............................................31.... 787
*NOTE: If venting with (2) 90
0
elbows off rear of unit
the dimensions C, D, and E, will change.
MODEL VENT A B C D E
SL-750TRS-IPI-D
Top 42 16-1/4 31-7/8 45 63-3/4
Rear 42 16-1/4 36-5/8 52 73-1/4
SL-550TRS-IPI-D
Top 37 16-1/4 29-3/8 41-1/2 58-3/4
Rear 37 16-1/4 34-1/8 48-1/2 68-1/4
SL-350TRS-C
Top 34 16-1/4 27-7/8 39-3/8 55-5/8
Rear 34 16-1/4 32-5/8 46-3/8 65-1/8
*
*
*
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
19
Figure 5. Framing Dimensions
Framing should be
constructed of 2 X 4
lumber or heavier.
The framing headers
may rest on the
appliance stand-offs.
Step 2. Framing the Appliance
Appliance framing can be built before or after the appliance
is set in place. Framing should be positioned to accommo-
date wall coverings and appliance facing material. The dia-
gram below shows framing reference dimensions.
CAUTION: MEASURE APPLIANCE DIMENSIONS AND
VERIFY FRAMING METHODS AND WALL COVERING
DETAILS BEFORE FRAMING.
VENT
FRAMING
HOLE
E
D
Models A B C D E
SL-750TRS-IPI-D 42 38 1/4” 16 1/4” 41 27 7/8”
SL-550TRS-IPI-D 37 33 16 1/4” 36 1/2” 24 3/8”
SL-350TRS-C 34 31 16 1/4” 35 1/2” 22 3/8”
A
B
C
WALL STUD
NON-COMBUSTIBLE ZONE
IS DEFINED BY 3” ABOVE THE
ELBOW FOR THE ENTIRE
WIDTH AND DEPTH (BEHIND THE
FRONT HEADER) OF THE FIREBOX.
3”
2-1/4”
*The center of the
framing hole is one (1)
inch (25.4mm) above
the center of the hori-
zontal vent pipe.
*
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
20
NOTE: PIPES OVERLAP 1-1/4 INCHES
(34.93mm) AT EACH JOINT.
Figure 6. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe)
D
V
P
9
0
S
T
12-9/16
11-1/4
7-1/4
1-1/4 TYP
1/2 TYP
8-9/16
DVP36
DVP48
48
24
36
4
6
DVP4
DVP6
12
DVP12
2
MIN.
DVP12A
12-3/16
MAX.
DVP24
9-7/8
45.0
O
10-1/4
DVP45
14-1/4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45

Heat & Glo LifeStyle SL-750TRS-IPI-D User manual

Category
Fireplaces
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI