  • Hello! I am an AI chatbot trained to assist you with the Almost Heaven Saunas AHBPT6PRU Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
In addition to reading this manual through to the end before proceeding with assembly,
you may nd our instruction video helpful.
You can nd it at: youtube.com/user/almostheavensauna
KIP Heater Installation
& Owners Manual
Read this entire manual through to the end before proceeding with the installation.
KIP HEATER INSTALLATION MANUAL
HEATER INSTRUCTIONS
Your Almost Heaven Sauna is paired with a genuine Finnish heater manufactured by Harvia Oy, the world leader in sauna heaters.
Refer to this guide for installation and operation instructions. Please note, a licensed electrician should perform all electrical
work, and Almost Heaven Saunas sta is available to assist with any questions you or your electrician may have. Please call us at
888-355-3050 for technical assistance.
Information for your electrician:
4.5kW and 6.0kW KIP Heaters
• 30-ampdoublepolebreaker
• 240volts
• 1Phase
• 10/2wire.For6.0kWheaters,an8/2wireisrecommendedfordistancesgreaterthan30’frompowersource
• DonotuseGFCIwiththisheater
• Usecopperwirewith90Cinsulation
8.0kW KIP Heaters
• 40-ampdoublepolebreaker
• 240volts
• 1Phase
• 8/2wire
• DonotuseGFCIwiththisheater
• Usecopperwirewith90Cinsulation
POSITIONING YOUR HEATER
Unpackyourheater,settingasidethetrimpiecesandbagwithplacardsandscrews(1).
Removethehardwarebagfromthebaggiewiththesafetyplacards(2),selectingthetwolongerlagscrews(1.5”).Youwillsecure
theseintothesaunawallsothat¼”ofthescrewprotrudesfromthewall(3,4).
page2
Image1
Image2  Image3 Image4 
a. For barrel saunas,theheatermountingholesarepre-drilled(5).
b. For indoor saunas,thescrewsshouldbemounted22”otheoor,andspaced15.25”apartapproximatelycenteredabovethe
ventholes(ifpresent).Itisnethattheheateriscoveringtheholesasventilationstilloccurs(6).
Hangtheheateronthemountingscrewstoensureitislevelandthatitsbasesits5-7”otheoorofthesauna.
If these criteria are met, make a mark on the wall of the sauna directly behind one of the rubber gaskets on the lower back of the
heater(7);thiswillbewherethepowerentersthesauna.Taketheheaterothewallandremovetherubbergasket,exposingthe
cutout.Itdoesnotmatterwhichgasketisremoved(8).
NOTE: While this location is the most common, the power can enter the sauna at any location. It is not recommended you use the
pre-drilled vent holes as an entrance for the conduit.
REMOVING THE STONE GUARD AND BOTTOM COVER
Removethetwoscrewsholdingthestoneguardinplace.Prytheguardbackandliftuptoremoveit.Cliptheziptieholdingthe
metalsensorhousingfromtheelementsandsetitasideforlaterinstallation(9–11).
KIP HEATER INSTALLATION MANUAL
page 3
Image 7 Image 8
Image 5
Image 6
Image9 Image10Image11
Pre-drilled holes
22
15 ¼
Fliptheheateronitsbackandremovethebottomcover.Locatethe4”temperaturesensor,uncoilingthelamentandwiringit
outthesmallnotchatthebaseoftheheater.Setthesensorasideforlaterinstallation(12–14).
CONNECTING TO POWER
All wiring should be done by a licensed electrician.
Boreaholeatthemarkyoumadeinstep2,beingsureitiswideenoughtoaccommodatethewire(15).Feedthewirethroughthis
holeandthenthroughthecutoutatthebaseoftheheater(16).Beingsurethebreakeriso,connectyourheatertopoweraccording
tothediagrambelow.TheonlyconnectionsthatshouldbemadearetwohotlinestoL1andL2,andthegroundlinetotheground
screw(17).Replacethebottomcoveroncewiringiscomplete,andrehangtheheateronthescrews(18).Turnthebreakeron.
KIP HEATER INSTALLATION MANUAL
page 4
Image12 Image13Image14
Image15 Image16Image17Image18
Image19 
L1
L2
GND
Temperature
Sensor
NOTE: Thepowershouldnot enter the heater
throughthecutoutonthebottomcover–this
cutout is to allow access to the high-limit reset
button(19).
OPERATING THE HEATER
This heater is operated using two dials – the thermostat and the timer.
Thermostat (left) controls the temperature of the sauna. Set it according to your personal preference.
Timer (right) turns the heater on and o, and has the ability to delay the start.
If the heater has power, you should hear a loud “clunk” at both the 0 and the large 1. In between these “clunks” is one hour of heat time.
Toimmediatelyturntheheateron,werecommendturningthedialpastthetwoclunkstonumber1or2.Turnthetimerbackuntil
oneloudclunkisheard,immediatelystoppingtheturn.Thiswillbegintheonehourofheattime.
Theheaterwillautomaticallyshutoafteronehour.Youmayhavetorestartyourheaterwhileyouareinthesauna.
Thesmallernumbers1-8refertothenumberofhoursforthedelaystart.Forexample,ifyouturnthetimerto5,yourheaterwill
begin heating in ve hours.
Withyoursaunadooropen,turnonyourheaterforveminutestoallowthenon-toxicprotectivecoatingontheheating
elementsto“burno.Itisnormaltoseesomelightsmokeasthiscoatingburnso.
PLACING THE STONES
While the heater is cooling, rinse your sauna stones to prepare them for placement.
Placethesmallerstonesinbetweenandaroundthethreeheatingelements.Thestonesshouldtouchtheelements,butnotbend
them. Reserve the larger stones for placement on top of the heating elements, covering them completely. Replace the stone
guard(21,22).
NOTE:Packingstonesintootightlywillrestrictairowandaecttheeciencyofyourheater.Looselypositionthestonesaround
andabovetheheatingelements.Itiscommontohave5-10stonesleftover.
KIP HEATER INSTALLATION MANUAL
page 5
Image21 Image22
P
R
E
S
E
T
.
.
.
D
E
L
A
Y
S
T
A
R
T
TEMPERATURE SENSOR PLACEMENT
Mountthesensorhousing(themetalcomponentziptiedtotheelementsinstep1)vertically,atleast18”tothesideoftheheater
and18”belowthehighestpointofthesauna.Ifitistoohighonthewallortooclosetotheheater,itwillsensethatthesaunais
hotterthanitactuallyis,triggeringaprematureshuto(23).
Placethesensorpininthehousingwiththebulbuprightandclosethewingsofthehousingoverthesensorpin(24,25).
Concealthesensorhousingandpinwiththesensorcoverandprovidedscrew(26).
Concealthesensorwirewiththegroovedtrimpiecesfromstep1(27).Youwilllikelyhavetocutseveraltrimpiecestotthedistance
betweenyourheaterandthesensorpin.Mountthemwiththescrewsprovidedinthehardwarebaggieyouremovedinstep1.
INSTALLING THE HEATER GUARD
YourKIPheatercomeswithacedarheaterguard.Usetheprovidedhardwaretoassemblethefencecomponentstogether(28-31),and
secureittothewallsothatitevenlysurroundstheheater(32).Itshouldbepositionednohigherthantheexposedsaunastones.
KIP HEATER INSTALLATION MANUAL
page 6
Image24 Image25Image26
Image23
Image28 Image29Image30Image31Image32
18
18
Image27
USING YOUR SAUNA HEATER
Yoursaunahasbeenpairedwithanappropriatelysizedheatertoconsistentlyachievetemperaturesof180°-195°F.Youshould
expectyoursaunatobeatauseabletemperaturein45-60minutes.
You have the option to pour water onto the stones to generate steam. Please note, little water is required to achieve this. For most
saunausers,aladlefullofwaterissucient.Iftoomuchwaterispouredontothestones,itwilldripoutthebaseoftheheaterand
should be wiped up with a towel after the sauna session.
If you’d like to continue the sauna session after the automatic one hour shuto, simply restart the heater.
Consultyoursaunamanualforthetypicalsaunaroutine,andenjoy!
TROUBLESHOOTING
If the sauna heater does not operate after the initial installation:
Checkthebreakertobesureitison
Verifywithyourelectricianthat240voltsisreachingtheheater
Doublecheckthatthetimerisbeingoperatedcorrectly(refertoinstructionsinstep5)
If the sauna heater operates but the sauna room does not come to temperature:
Verify the timer has not timed out. If it has, restart it.
Assesshowthestonesareplacedaroundtheheatingelements.Iftheyarepackedtootightly,itwillrestrictairowandaectthe
eciencyofyourheater.Repositionthestonesifneeded.
Checkthepositionofthetemperaturesensor(refertostep7a).Ifitistoohighinthesaunaortooclosetotheheater,itwilltrigger
a premature shuto in your heater.
Pressthehighlimitresetbuttonbelowtheheater–itmayneedresetting.
If none of the above recommendations get your heater working, please call Almost Heaven Saunas at 888-355-3050 to diagnose
further.
KIP HEATER INSTALLATION MANUAL
page 7
KIP Heater Installation & Owners Manual
almostheaven.com
/