  • Hello! I am an AI chatbot trained to assist you with the ZALMAN ZM850-HP PLUS User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
User’s Manual
ZM850-HP PLUS
ZM1000-HP PLUS
Ver. 1.0
www.ZALMAN.com
To ensure safe and easy installation,
please read the following precautions.
Dual Heatpipe Cooled
Power Supply
11
1. Warnings and Safety Precautions
2. Components
Power Supply
AC Power Cord
Four (4) Fixing Bolts
Four (4) Velcro Ties
User’s Manual
Opening the cover of the product while the power cord is plugged into an outlet
may cause electrocution or critical damage to the product.
Handling the power cord with wet hands may cause electrocution.
Inserting ngers or metallic objects into the cooling fan may cause injury or
electrocution.
Operating the product in an extremely cold or hot environment can degrade
product performance
and lifespan.
Exposure to liquids may cause malfunction.
Operation in a humid or non-ventilated environment may reduce product lifespan.
Plugging the main power connector P1 into the motherboard while the product is
connected to the AC power source may cause damage to the motherboard.
Make sure that the connectors are connected to their designated locations, and
that the connectors are not
oriented in the wrong direction when connecting the
DC output connectors.
Please use gloves to prevent injuries during installation.
Product designs and specications may be revised without prior notication to
improve quality and performance.
Neglecting the following may cause serious injury or death.
Neglecting the following may cause minor injuries, degrade product
conditions or cause malfun
ction.
Caution
Warning
Disclaimer) Zalman Tech Co., Ltd. is not responsible for any damages due
to external causes, including but not limited to, improper use,
problems with electrical power, accident, neglect, alteration,
repair, improper installation, or improper testing.
22
3. Specications
1) ZM850-HP PLUS Electrical & Physical Specications
2) ZM1000-HP PLUS Electrical & Physical Specications
AC Input Range
Voltage 100 ~ 240VAC ZM850-HP PLUS
Frequency 50 ~ 60
V
out
Output Load Rating Combined
Combined Power
AC Input Current
100VAC 11A I
min
I
max
I
peak
240VAC 5.5A +3.3V 0.0A 20A
180W
850W
PFC Type Active PFC +5V 0.5A 24A
Power Factor MAX 99% +12V1 0.1A 25A 27A
816W
Inrush Current Limit
(@ Cold start at 25)
115VAC 60A +12V2 0.0A 25A 27A
230VAC 150A +12V3 0.0A 35A 37A
Efciency MAX 90% @ 230VAC, Typical load +12V4 0.0A 28A 30A
DC Output Vol
tage
Regulation
V
out
Stable Range
At Full
Load
-12V 0.0A 0.5A 6W
+3.3VDC ±5% +3.14 ~ +3.47V +5VSB 0.1A 3.5A 17.5W
+5VDC ±5% +4.75 ~ +5.25V Ambient Temperature
+12V1DC ±5% +11.4 ~ +12.6V Operation 0 ~ 40
+12V2DC ±5% +11.4 ~ +12.6V Stored -20 ~ 60
+12V3DC ±5% +11.4 ~ +12.6V Ambient Humidity
+12V4DC ±5% +11.4 ~ +12.6V Operation 10 ~ 90%RH
-12VDC ±10% -10.8 ~ -13.0V Stored 5 ~ 95%RH
+5VSB ±5% +4.75 ~ +5.25V Dimensions
DC Output Ripple &
Noise
V
out
Standard Range
At Full
Load
210(L) × 150(W) × 86(H)
+3.3VDC 50mV Weight
+5VDC 50mV 4.0(Full Package)
+12V1DC 120mV Safety Features
+12V2DC 120mV Over-Voltage Protection(OVP)
+12V3DC 120mV Over-Current Protection(OCP)
+12V4DC 120mV Under-Voltage Protection(UVP)
-12VDC 120mV Short-Circuit Protection(SCP)
+5VSB 50mV Over-Temperature Protection(OTP)
AC Input Range
Voltage 100 ~ 240VAC ZM1000-HP PLUS
Frequency 50 ~ 60
V
out
Output Load Rating Combined
Combined Power
AC Input Current
100VAC 12A I
min
I
max
I
peak
240VAC 6A +3.3V 0.0A 25A
180W
1000W
PFC Type Active PFC +5V 0.5A 30A
Power Factor MAX 99% +12V1 0.1A 28A 30A
984W
Inrush Current Limit
(@ Cold start at 25)
115VAC 60A +12V2 0.0A 25A 27A
230VAC 150A +12V3 0.0A 35A 37A
Efciency MAX 90% @ 230VAC, Typical load +12V4 0.0A 28A 30A
DC Output Vol
tage
Regulation
V
out
Stable Range
At Full
Load
-12V 0.0A 0.5A 6W
+3.3VDC ±5% +3.14 ~ +3.47V +5VSB 0.1A 3.5A 17.5W
+5VDC ±5% +4.75 ~ +5.25V Ambient Temperature
+12V1DC ±5% +11.4 ~ +12.6V Operation 0 ~ 40
+12V2DC ±5% +11.4 ~ +12.6V Stored -20 ~ 60
+12V3DC ±5% +11.4 ~ +12.6V Ambient Humidity
+12V4DC ±5% +11.4 ~ +12.6V Operation 10 ~ 90%RH
-12VDC ±10% -10.8 ~ -13.0V Stored 5 ~ 95%RH
+5VSB ±5% +4.75 ~ +5.25V Dimensions
DC Output Ripple &
Noise
V
out
Standard Range
At Full
Load
210(L) × 150(W) × 86(H)
+3.3VDC 50mV Weight
+5VDC 50mV 4.0(Full Package)
+12V1DC 120mV Safety Features
+12V2DC 120mV Over-Voltage Protection(OVP)
+12V3DC 120mV Over-Current Protection(OCP)
+12V4DC 120mV Under-Voltage Protection(UVP)
-12VDC 120mV Short-Circuit Protection(SCP)
+5VSB 50mV Over-Temperature Protection(OTP)
33
3) DC Output Power Cable Specications
44
4. Certications
/