Pelco IWM-IWM24 Series Wall Mount Installation guide

Type
Installation guide

This manual is also suitable for

INSTALLATION/OPERATION
C
288M-I (3/20)
IWM/IWM24 Series
Wall Mount
2 C288M-I (3/20)
Contents
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
IWM Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
User Supplied Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
IWM24 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
User Supplied Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
IWM Series Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Prepare the Mounting Surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Pull the Wiring and Attach the Mount to the Surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Install the Dome. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
IWM24 Series Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Prepare the Mounting Surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Prepare the IWM24 Series Mount for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Pull the Wiring and Attach the Mount to the Surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connect the Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Install the Dome. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Wiring Requirements and Distances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
List of Illustrations
1 IWM24 Series Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Voltage Selection Switch and Fuse Holder Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 IWM24 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
List of Tables
A Video Coaxial Cable Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
B 24 VAC Wiring Distances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
C288M-I (3/20) 3
Important Safety Instructions
Read these instructions.
1. Keep these instructions.
2. Heed all warnings.
3. Follow all instructions.
4. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
5. Only use attachments/accessories specified by the manufacturer.
6. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
7. Installation should be done only by qualified personnel and conform to all local codes.
8. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not
be installed where exposed to rain and moisture.
9. Use only installation methods and materials capable of supporting four times the maximum specified load.
10. Use stainless steel hardware to fasten the mount to outdoor surfaces.
11. To prevent damage from water leakage when installing a mount outdoors on a roof or wall, apply sealant around the bolt holes between the
mount and mounting surface.
12. Only use replacement parts recommended by Pelco.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present
within this unit.
This symbol indicates that there are important operating and maintenance instructions in
the literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
4 C288M-I (3/20)
Description
IWM/IWM24 Series wall mounts are designed for use with Spectra
®
, DF5, DF8, and Sarix
IE Series pendant domes. The indoor/outdoor mounts
can be installed directly to a wall or attached to an adapter and mounted to a corner, parapet, or pole mount. The mounts support maximum loads
of 75 lb (34 kg) and feature cable feedthrough holes to conceal wiring.
The IWM24 Series mount has a 24 VAC, 100 VA transformer with selectable input power (120/240 VAC, 50/60 Hz).
MODELS
IWM SERIES
PARTS LIST
USER SUPPLIED PARTS LIST
The following parts are needed but not supplied:
IWM24 SERIES
PARTS LIST
USER SUPPLIED PARTS LIST
The following parts are needed but not supplied:
IWM-BK
IWM-GY
IWM-SR
IWM24-BK
IWM24-GY
IWM24-SR
IWM-SW/IWM24-SW
Black-finish wall mount
S
ame as IWM-BK except gray finish
Same as IWM-BK except light gray finish (for Sarix IE Series domes; requires IE-P pendant mount adapter)
Black-finish wall mount with 100 VA transformer inside mount to power dome
Same as IWM24-BK except gray finish
Same as IWM24-BK except light gray finish (for Sarix IE Series domes; requires IE-P pendant mount adapter)
Same as IWM-BK/IWM24-BK except white finish (RAL9003)
Qty Description
1 Wall mount with mounting plate
Qty Description
4 Mounting fasteners, up to 3/8-inch diameter
1 (Outdoor installations only) Waterproof sealant for fastener holes to prevent water damage
1 (Optional) 1.5-inch NPT threaded pipe
Qty Description
1 Wall mount with mounting plate
Qty Description
1 or 2 Conduit fitting(s) or gland(s) of appropriate size, depending on installation type (external or through-wall)
4 Mounting fasteners, up to 3/8-inch (0.95 cm) diameter
1 or 2 Fitting nut(s), depending on installation type (external or through-wall)
1 (Outdoor installations only) Waterproof sealant for fastener holes to prevent water damage
1 (Optional) 1.5-inch NPT threaded pipe
C288M-I (3/20) 5
Installation
IWM SERIES MODELS
PREPARE THE MOUNTING SURFACE
1. Determine the mounting location:
If the mount is to be attached to a corner, parapet, or pole mount adapter, install the adapter plate (refer to the instructions supplied
with the adapter).
If the mount is to be attached to a wall, use the base of the IWM Series mount as a template and mark the four fastener positions on
the mounting surface.
2. Set the mount aside and prepare the holes for the fasteners (not supplied).
PULL THE WIRING AND ATTACH THE MOUNT TO THE SURFACE
1. Pull the video/power wiring through the mount. (Refer to Table A on page 9 for video coaxial cable requirements. Refer to Table B on page 9
for the recommended 24 VAC wiring distance information.)
2. Attach the mount securely with four fasteners of appropriate length (not supplied). Use fasteners with a maximum diameter of 3/8-inch.
3. (Outdoor installations only) Seal the fastener holes with an appropriate sealant (not supplied) to prevent water damage. Be sure to apply
the sealant between the mount and the mounting surface.
4. (Optional) If using a 1.5-inch NPT threaded pipe (not supplied), pull the wiring through the pipe.
INSTALL THE DOME
1. Attach the dome back box to the mount and tighten the setscrew.
2. Make all necessary electrical connections to dome.
3. Refer to the manual supplied with the dome system to complete the installation.
IWM24 SERIES MODELS
PREPARE THE MOUNTING SURFACE
1. Determine the mounting location:
If the mount is to be attached to a corner, parapet, or pole mount adapter, install the adapter plate (refer to the instructions supplied
with the adapter).
If the mount is to be attached to a wall, use the base of the IWM24 Series mount as a template and mark the four fastener positions
on the mounting surface.
2. Set the mount aside and prepare the holes for the fasteners (not supplied).
6 C288M-I (3/20)
PREPARE THE IWM24 SERIES MOUNT FOR INSTALLATION
1. Loosen the two Phillips pan-head screws, and remove the access plate from the bottom of the mount arm.
Figure 1. IWM24 Series Mount
2. Install the conduit fittings or glands (not supplied) in either the bottom or the back of the mount, depending on installation type.
To install the conduit fitting or gland in the bottom of the mount:
(1) Remove the 0.75-inch (1.91 cm) NPT plug.
(2) Install a conduit fitting or gland in the 0.75-inch NPT hole.
To install the conduit fittings or glands (not supplied) in the back of the mount:
(1) Insert the male end of the conduit fitting or gland into the cable hole located on the back plate of the mount.
(2) Hold the conduit fitting or gland in the hole with one hand while you reach into the mount through the access hole with the other
hand.
(3) Attach a fitting nut (not supplied) to the conduit fitting or gland, and rotate the fitting nut to hand-tighten.
(4) Repeat the previous steps to install a second conduit fitting or gland.
3. The transformer is preset to operate at 120 VAC. If necessary, change the voltage selection switch to operate at 230 VAC (refer to Figure 2).
ACCESS PLATE
(IWM24-BK,
IWM24-GY,
AND IWM24-SR ONLY)
SETSCREW
3/4-INCH NPT PLUG
C288M-I (3/20) 7
4. Install the proper fuse for the set voltage (refer to Figure 2). For 120 VAC, use the 1.6 A, 120 VAC, fast-acting fuse; or for 240 VAC, use the
500 mA, 240 VAC, fast-acting fuse. The fuse holder is located to the left of the voltage selection switch.
NOTE: The mount arm is shipped with extra fuses.
Figure 2. Voltage Selection Switch and Fuse Holder Location
PULL THE WIRING AND ATTACH THE MOUNT TO THE SURFACE
1. Pull the video/power wiring through either the bottom or the back of the mount and attach the mount to the mounting surface, depending
on installation type. (Refer to Table A on page 9 for video coaxial cable requirements. Refer to Table B on page 9 for the recommended
24 VAC wiring distance information.)
To pull the wiring through the bottom of the mount:
(1) Attach the mount to the mounting surface with four fasteners of an appropriate length (not supplied). Use fasteners with a
maximum diameter of 3/8-inch.
(2) Tighten the fasteners to create a waterproof seal between the gasket and the back of the mounting plate.
(3) Pull the cables through the conduit fitting or gland in the bottom of the mount.
(4) Continue to pull the video cable through the top of the mount.
To pull the wiring through the back of the mount:
(1) Pull the cables through the conduit fittings or glands under the transformer in the back of the mount.
(2) Continue to pull the video cable through the top of the mount.
(3) Attach the mount to the mounting surface with four fasteners of an appropriate length (not supplied). Use fasteners with a
maximum diameter of 3/8-inch.
(4) Tighten the fasteners to create a waterproof seal between the gasket and the back of the mounting plate.
NOTE: When installing the mount to a wall outdoors, you must seal the fastener holes with an appropriate sealant (not supplied) to prevent
water damage. Be sure to apply the sealant between the mount and the mounting surface.
115V
TRANSFORMER
POWER
FUSE
HOLDER
VOLTAGE
SELECTION
SWITCH
SPARE FUSE
STORAGE
AC LOW
(NEUT)
AC HI
(HOT)
8 C288M-I (3/20)
CONNECT THE INPUT POWER
1. Connect the power to the transformer (refer to Figure 3).
a. Connect the AC High (hot) wire to the clamp on the black transformer wire. The AC High wire is labeled AC HI [HOT].
b. Connect the AC Low (neutral) wire to the clamp on the white transformer wire. The AC Low wire is labeled AC LOW [NEUT].
2. Connect the input ground wire to the green and yellow striped wire that is attached to the mount.
Figure 3. IWM24 Wiring
INSTALL THE DOME
1. Attach the dome back box to the mount and tighten the setscrew.
2. Make all necessary electrical connections to the dome.
WARNING: If you are wiring more than one dome, wire the power in each dome the same way. For example, the wiring from one side of
the transformer must be connected to the corresponding connector on each dome. If you reverse the wiring, the cameras will be out of
phase with each other and may produce a vertical roll when switching between cameras.
3. Place extra fuses in the clips attached to the inside of the access plate.
4. Replace the access plate and tighten the screws to compress the gasket and create a waterproof seal.
5. Refer to the manual supplied with the dome system to complete the installation.
1a
1
1b
2a
2
2b
SW03-2211-0500
FS02-0301-1103
BRN
BLK
120/230 VAC INPUT
AC HIGH
(HOT)
AC LOW
(NEUT)
WHT
SPLICE
XF02-0604-0001
(TO DOME)
24 VAC 100 VA OUTPUT
YEL
BRN
RED
ORG
YEL
BLU
BLU
GRN/YEL
WIRING DIAGRAM COLOR KEY
COLOR DESCRIPTION
BLK BLACK, SOLID
WHT WHITE, SOLID
BLU BLUE, SOLID
BRN BROWN, SOLID
ORG ORANGE, SOLID
RED RED, SOLID
YEL YELLOW, SOLID
GRN/YEL GREEN & YELLOW, STRIPED
C288M-I (3/20) 9
Wiring Requirements and Distances
Table B describes the recommended maximum distances for 24 VAC applications, which are calculated with a 10 percent voltage drop. (Ten
percent is generally the maximum allowable voltage drop for AC-powered devices. For example, an enclosure that requires 80 VA and is installed
35 feet (10 m) from the transformer would require a minimum wire gauge of 20 AWG.
NOTE: Wire gauges are standard AWG or metric sizes. Distances are calculated in feet; values in parentheses are meters.
Table A. Video Coaxial Cable Requirements
Cable Type* Maximum Distance
RG59/U
RG6/U
RG11/U
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
*Minimum cable requirements:
75-ohms impedance
All-copper center conductor
All-copper braided shield with 95% braid
coverage
Table B. 24 VAC Wiring Distances
Total
VA
Wire Gauge
Maximum distance from transformer to load
20
(0.5 mm
2
)
18
(1.0 mm
2
)
16
(1.5 mm
2
)
14
(2.5 mm
2
)
12
(4.0 mm
2
)
10
(6.0 mm
2
)
10
283
(86)
451
(137)
716
(218)
1142
(348)
1811
(551)
2880
(877)
20
141
(42)
225
(68)
358
(109)
571
(174)
905
(275)
1440
(438)
30
94
(28)
150
(45)
238
(72)
380
(115)
603
(183)
960
(292)
40
70
(21)
112
(34)
179
(54)
285
(86)
452
(137)
720
(219)
50
56
(17)
90
(27)
143
(43)
228
(69)
362
(110)
576
(175)
60
47
(14)
75
(22)
119
(36)
190
(57)
301
(91)
480
(146)
70
40
(12)
64
(19)
102
(31)
163
(49)
258
(78)
411
(125)
80
35
(10)
56
(17)
89
(27)
142
(43)
226
(6
8)
360
(109)
90
31
(9)
50
(15)
79
(24)
126
(38)
201
(61)
320
(97)
100
28
(8)
45
(13)
71
(21)
114
(34)
181
(55)
288
(87)
10 C288M-I (3/20)
Specifications
MECHANICAL
Construction
Finish
I
WM-BK, IWM24-BK
IWM-GY, IWM24-GY
IWM-SR, IWM24-SR
IWM-SW, IWM24-SW
Cable Entry
IWM Series Mount
IWM24 Series Mount
Mount Method
L
ocking Me
thod
Dome Mounting
Maximum Load
ELECTRICAL
IWM24 Series
Input Power
Output Power
Fuse
GENERAL
Environment
Operating Range
Unit Weight
IWM Series
IWM24 Series
Ratings (IWM24
Series only)
Cast aluminum
Black polyester powder coat
Gray polyester powder coat
Light gray polyester powder coat
White finish (RAL9003) polyester powder coat
One 0.75-inch (1.91 cm) NPT opening on the bottom of the mount
Two cable feedthrough holes on the mounting plate accommodate 0.50-inch (1.27 cm) fittings or PG13.5
liquid-tight gland fittings; one 0.75-inch (1.91 cm) NPT opening on the bottom of the mount for conduit
connector
Secure to wall with 4 fasteners of appropriate length (fasteners not supplied); use fasteners up to
3/8-inch (0.95 cm) diameter
6-32 Allen-head setscrew to tighten pipe
Dome screws directly into mount
75 lb (34 kg)
Switchable 120/240 VAC, 50/60 Hz through an internal slide switch
24 VAC, 100 VA transformer
One 1.6 A, 120 VAC fast-acting fuse
One 500 mA, 240 VAC fast-acting fuse
Indoor/outdoor
–50° to 120°F (–46° to 49°C)
2.46 lb (1.12 kg)
6.58 lb (2.98 kg)
Meets NEMA 4 and IP 56 standards
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
14.629 (37.15)
8.0
(20.32)
7.5
(19.05)
6.5
(16.51)
4.5 (11.43)
5.50 (13.97)
13.50 (34.30)
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in
material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
Five years:
Fiber optic products
Unshielded Twisted Pair (UTP) transmission products
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models
Three years:
Pelco-designed fixed network cameras and network dome cameras with
Sarix
technology.
Pelco-branded fixed camera models (CCC1390H Series, C10DN Series,
C10CH Series, and IP3701H Series)
EH1500 Series enclosures
Spectra
®
IV products (including Spectra IV IP)
Camclosure
®
Series (IS, ICS, IP) integrated camera systems
DX Series digital video recorders (except DX9000 Series which is covered
for a period of one year), DVR5100 Series digital video recorders, Digital
Sentry
®
Series hardware products, DVX Series digital video recorders, and
NVR300 Series network video recorders
Endura
®
Series distributed network-based video products
Genex
®
Series products (multiplexers, server, and keyboard)
PMCL200/300/400 Series LCD monitors
PMCL5xx Series FHD monitors
Two years:
Standard varifocal, fixed focal, and motorized zoom lenses
DF5/DF8 Series fixed dome products
Legacy
®
Series integrated positioning systems
Spectra III
, Spectra Mini, Spectra Mini IP, Esprit
®
, ExSite
®
, and PS20
scanners, including when used in continuous motion applications.
Esprit Ti and TI2500 Series thermal imaging products
Esprit and WW5700 Series window wiper (excluding wiper blades).
CM6700/CM6800/CM9700 Series matrix
Digital Light Processing (DLP
®
) displays (except lamp and color wheel). The
lamp and color wheel will be covered for a period of 90 days. The air filter is
not covered under warranty.
Intelli-M
®
eIDC controllers
One year:
Video cassette recorders (VCRs), except video heads. Video heads will be
covered for a period of six months.
•Six months:
All pan and tilts, scanners, or preset lenses used in continuous motion
applications (preset scan, tour, and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid
to a Pelco designated location. Repairs made necessary by reason of misuse,
alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss
resulting from the specific use or application made of the Products. Pelco’s liability
for any claim, whether based on breach of contract, negligence, infringement of
any rights of any party or product liability, relating to the Products shall not exceed
the price paid by the Dealer to Pelco for such Products. In no event will Pelco be
liable for any special, incidental, or consequential damages (including loss of use,
loss of profit, and claims of third parties) however caused, whether by the
negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may
also have additional rights, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559
) 292-1981 to obtain a Repair Authorization number (RA), and provide the
following information:
1. Model and serial number
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product that does not fall under
the warranty conditions stated above, please include a written explanation with
the product when returned.
Method of return shipment shall be the same or equal to the method by which the
item was received by Pelco.
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100
or (559) 292-1981 to obtain an authorization number (CA number if returned for
credit, and RA number if returned for repair) and designated return location.
All merchandise returned for credit may be subject to a 20 percent restocking and
refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned
CA or RA number and freight should be prepaid.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
2-10-10
REVISION HISTORY
Manual # Date Comments
C288M
C288M-A 9/97
C288M-B 3/98
C288M-C 5/99
C288M-D 12/01
C288M-E 10/03
C288M-F 7/04
C288M-G 8/05
C288M-H
C288M-I
10/10
3/20
Original version.
Completely revised. Includes IWM24 Series mounts.
Included wiring diagram. Modified Section 3.2, step 3f. Changed manual pagination.
Removed template. Revised Description and Installation instructions. Updated Dimension Drawing. Added certifications. Changed to new format.
Modified manual to reflect changes per ECO 01-7388. Changed to new format. R
emoved IWM-WT model.
Modified manual to incorporate power wiring changes per ECO 03-8870.
Modified manual to incorporate design changes per ECO 04-9902.
Revised manual per ECO 05-11280 to change input power and a fuse value from 230 VAC to 240 VAC.
Added the IWM-SR and IWM24-SR models, added a parts list, revised the installation sections, and updated the warranty.
Added -SW models.
© Copyright 2020,
Pelco, Inc.
All rights reserved.
Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates.
All other product names and services are the property of their respective companies.
Product specifications and availability are subject to change without notice.
Pelco, Inc. 625 W. Alluvial Fresno, California 93711 USA USA & Canada
Tel (800) 289-9100 Fax (800) 289-9150
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
www.pelco.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Pelco IWM-IWM24 Series Wall Mount Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI