Subject
Modification of wiring
Model
Multi Green (all PNCs)
Problem
_
Reason
Evolution due to use of integrated circuit
Actions in
factory
Substitution of old wiring (contactor, relay, brake system) by a
power board, one phase brake + substitution of the PSA detector
∅KJ006 by PLA detector ∅KQ281.
Actions in
field
Application date : Year 2005, Week 14 –
- This modification has not to be done on machines built
before this date
- If repair necessary, check serial number before ordering
parts and refer to the new technical guide